1Formulas and methods

Complex numbers

Rectangular form
z = a + jb, j² = −1, z̄ = a − jb
Modulus and argument
|z| = √(a² + b²), tan θ = b/a (check the quadrant)
Polar and exponential form
z = r∠θ = r(cos θ + j sin θ) = r·ejθ
Division
z₁/z₂ = z₁z̄₂/|z₂|²
Product and quotient
r₁∠θ₁ · r₂∠θ₂ = r₁r₂∠(θ₁ + θ₂), r₁∠θ₁ / r₂∠θ₂ = (r₁/r₂)∠(θ₁ − θ₂)
De Moivre
(r∠θ)ⁿ = rⁿ∠nθ
n-th roots
zk = R1/n∠((φ + 360°·k)/n), k = 0 … n − 1
Quadratic with p² < 4q
z = −p/2 ± j√(q − p²/4)

Method

  1. Decide which form suits the operation: rectangular a + jb for adding and subtracting, polar r∠θ for multiplying, dividing, powers and roots.
  2. Multiply out with j² = −1; divide by multiplying the top and bottom by the conjugate of the denominator.
  3. Convert with r = √(a² + b²) and θ from a sketch of the point (check the quadrant), and back with a = r cos θ, b = r sin θ.
  4. For powers use De Moivre, (r∠θ)ⁿ = rⁿ∠nθ; for zⁿ = R∠φ list all n roots R1/n∠((φ + 360°k)/n).

AC impedance & phasors

Impedances
ZR = R, ZL = jωL, ZC = 1/(jωC)
Angular frequency
ω = 2πf
Magnitude and angle
|Z| = √(R² + X²), φ = atan(X/R)
Phasor Ohm’s law
V = I·Z

Method

  1. Convert the frequency: ω = 2πf.
  2. Find each reactance: XL = ωL and XC = 1/(ωC).
  3. Add impedances like resistors, with Z = R + jX.
  4. Find the magnitude |Z| = √(R² + X²) and the angle φ = atan(X/R), then use Ohm’s law with phasors.

AC power & power factor

Real power
P = V·I·cos φ
Reactive power
Q = V·I·sin φ
Apparent power
S = V·I = √(P² + Q²)
Power factor
pf = cos φ = P/S
Correction capacitor
QC = P(tan φ1 − tan φ2), C = QC/(ωV²)

LC resonance, Q factor & bandwidth

Natural frequency
ω0 = 1/√(LC), f0 = 1/(2π√(LC))
Energy
W = ½CV0² = ½Cv² + ½Li²
Peak current
Imax = V0√(C/L)
Quality factor
Q = 2π·(energy stored)/(energy lost per cycle)
Series RLC
Q = (1/R)√(L/C), BW = R/(2πL)
Parallel RLC
Q = R√(C/L), BW = 1/(2πRC)
Bandwidth
BW = f2 − f1 = f0/Q, f0 = √(f1f2)
Half-power frequencies
f1,2 = f0(√(1 + 1/(4Q²)) ∓ 1/(2Q))
Tank with coil resistance r
RD = L/(C·r) = Q²·r
Decay of the amplitude
e−Rt/(2L)

Method

  1. Find the resonance frequency first: ω₀ = 1/√(LC) and f₀ = ω₀/(2π).
  2. Decide whether the circuit is series or parallel: series Q = (1/R)√(L/C), parallel Q = R√(C/L).
  3. Use BW = f₀/Q for the bandwidth, or the shortcuts R/(2πL) (series) and 1/(2πRC) (parallel).
  4. For energy questions, use that the total energy ½CV₀² stays constant in an ideal LC circuit and swings between C and L every quarter period.

Three-phase power

Y connection
VL = √3·Vph, IL = Iph
Δ connection
VL = Vph, IL = √3·Iph
Total real power
P = √3·VL·IL·cos φ = 3·Iph²·R
Apparent and reactive power
S = √3·VL·IL, Q = P·tan φ
Correction capacitors
QC = P(tan φ1 − tan φ2), C = QC/(3ωV²)
Voltage across each capacitor
Δ: VL Y: VL/√3
Motor input
Pin = Pout/η

RC & RL transients

Time constant
τ = RC | τ = L/R
Response
x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ
Capacitor at DC
open circuit; vC cannot jump
Inductor at DC
short circuit; iL cannot jump
Settled
t ≈ 5τ

Method

  1. Find the initial value just after switching: a capacitor voltage and an inductor current cannot jump.
  2. Find the final value long after switching: a capacitor acts as an open circuit, an inductor as a short circuit.
  3. Find the time constant: τ = RC or τ = L/R, using the resistance seen by the capacitor or inductor.
  4. Use x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ.

Thévenin & Norton

Thévenin voltage
Vth = Vopen circuit
Thévenin resistance
Rth: all sources off, seen from a–b
Norton current
IN = Vth/Rth
Load current
IL = Vth/(Rth + RL)
Maximum power transfer
RL = Rth, Pmax = Vth²/(4Rth)

Method

  1. Remove the load and mark the two terminals a and b.
  2. Find the open-circuit voltage between a and b: this is Vth.
  3. Switch off all independent sources and find the resistance seen from a–b: this is Rth.
  4. Put the load back on the equivalent circuit: Vth in series with Rth.
  5. For the Norton equivalent, convert: IN = Vth/Rth, with RN = Rth in parallel.

2Practice problems

1.Complex numbersMedium
ReIm22−2−244−4−466−6−6θz

Write z = 6∠−75° in rectangular form a + jb and give the real part a.

r = 6θ = −75°
a =
2.Complex numbersHard
ReIm11−1−122−2−2z₀z₁z₂

The roots of zⁿ = w with n = 3 and w = 8∠120° are zk = R1/n∠((φ + 360°·k)/n), k = 0, 1, 2. Find the imaginary part of z₀.

w = 8∠120°n = 3k = 0
Im(z₀) =
3.AC impedance & phasorsMedium
120 V200 HzR = 15 ΩL = 50 mHC = 100 µFI

A series RLC circuit is connected to a 120 V (rms), 200 Hz supply. Find the rms current I.

V = 120 V (rms)f = 200 HzR = 15 ΩL = 50 mHC = 100 µF
I = A
4.AC impedance & phasorsHard
12 V60 HzR = 60 ΩL = 250 mHC = 47 µF+−VC​

A series RLC circuit is connected to a 12 V (rms), 60 Hz supply. Find the rms voltage VC across the capacitor.

V = 12 V (rms)f = 60 HzR = 60 ΩL = 250 mHC = 47 µF
VC = V
5.AC power & power factorMedium
230 V127 kW, 0.75210 kW, 1I = ?

Two loads are connected in parallel to a 230 V single-phase supply: a 27 kW load at a power factor of 0.75 lagging and a 10 kW heater (unity power factor). Find the total current I drawn from the supply.

V = 230 VP1 = 27 kW, pf1 = 0.75 laggingP2 = 10 kW, pf2 = 1
I = A
6.AC power & power factorHard
P1​ = 49 kWQ1​S1​φ

A 150 kVA single-phase transformer supplies a load of 49 kW at a power factor of 0.65 lagging. How much extra real power ΔP can be added as a resistive (unity power factor) load before the transformer reaches its kVA rating?

Smax = 150 kVAP1 = 49 kWpf1 = 0.65
ΔP = kW
7.LC resonance, Q factor & bandwidthMedium
V2 Ω22 µH220 nF

A series RLC circuit has R = 2 Ω, L = 22 µH and C = 220 nF. Find its quality factor Q.

R = 2 ΩL = 22 µHC = 220 nF
Q =
8.LC resonance, Q factor & bandwidthHard
f|I|0.7071f0​ = ?50 kHz52.5 kHzBW

The half-power frequencies of a resonance curve are 50 kHz and 52.5 kHz. Find the resonance frequency as their geometric mean, and then the quality factor Q.

f1 = 50 kHzf2 = 52.5 kHz
Q =
9.Three-phase powerMedium
ABCVL​ = 480 VIL​ = 75 Acos φ = 0.75lagging

A balanced three-phase load draws a line current of 75 A from a supply with a line-to-line voltage of 480 V. The power factor is 0.75 lagging. Find the total real power P drawn by the load in kW.

VL = 480 VIL = 75 Acos φ = 0.75
P = kW
10.Three-phase powerHard
P = 60 kWφ1​S1​Q2​QC​

A balanced three-phase load takes 60 kW at a power factor of 0.65 lagging from a 415 V (line-to-line), 60 Hz supply. A three-phase capacitor bank in parallel with the load must raise the overall power factor to 0.92 lagging. The real power stays the same. The capacitors are connected in Y. Find the capacitance Cph of each capacitor in µF.

P = 60 kWpf1 = 0.65pf2 = 0.92VL = 415 Vf = 60 Hz
Cph = µF
11.RC & RL transientsMedium
+−Vs​6 Vt = 0R = 22 ΩL220 mHi(t)

The inductor carries no current before the switch closes at t = 0. Find the energy W stored in the inductor at t = 25 ms, in mJ.

Vs = 6 VR = 22 ΩL = 220 mHt = 25 ms
W = mJ
12.RC & RL transientsHard
+−Vs​9 Vopens at t = 0R1​ = 4.7 kΩR2​ = 4.7 kΩC220 µF+−vC​

The switch has been closed for a long time, so the circuit is in steady state. At t = 0 the switch opens. Find the capacitor voltage vC at t = 500 ms.

Vs = 9 VR1 = 4.7 kΩR2 = 4.7 kΩC = 220 µFt = 500 ms
vC = V
13.Thévenin & NortonMedium
R1​ = 8 ΩR3​ = 8 Ω+−V1​15 VR2​4 ΩAab

Find the Thévenin voltage Vth seen from terminals a–b.

V1 = 15 VR1 = 8 ΩR2 = 4 ΩR3 = 8 Ω
Vth = V
14.Thévenin & NortonHard
R1​ = 4 ΩR3​ = 6 Ω+−V1​18 VR2​8 ΩAIs​0.5 ABRL​2 ΩIL​

A load RL = 2 Ω is connected across a–b. Use a Thévenin equivalent to find the power PL delivered to the load.

V1 = 18 VIs = 0.5 AR1 = 4 ΩR2 = 8 ΩR3 = 6 ΩRL = 2 Ω
PL = W
15.Bode plots & marginsMedium
vin​R = 100 ΩL = 22 mHvout​

The RL high-pass filter shown has R = 100 Ω, L = 22 mH. A sinusoidal input of 180 Hz is applied. Find the phase shift φ of vout relative to vin, in degrees.

R = 100 ΩL = 22 mHf = 180 Hz
φ = °
16.Bode plots & marginsHard
|H| (dB)0.10.1111010100100−80−60−40−2002040ω (rad/s)φ (°)ω (rad/s)−270−180−900ω180​

A unity-feedback loop has the open-loop transfer function L(s) = 26/(s(s + 3)(s + 8)). Find the gain margin GM in dB.

L(s) = 26/(s(s + 3)(s + 8))
GM = dB

3Solutions

1.Complex numbers

Answer: a = 1.553

Polar form: z = r∠θ = r(cos θ + j sin θ) = r·ejθ, with r = |z| and θ = arg z. Back to rectangular form: a = r cos θ, b = r sin θ. The argument needs the quadrant: θ = atan(b/a) only when a > 0; for a < 0 add or subtract 180°. In polar form multiplication is easy: multiply the moduli and add the arguments; for division divide the moduli and subtract the arguments.

Components

a = 6·cos(−75°) = 1.553
b = 6·sin(−75°) = −5.796

Rectangular form

z = 1.553 − j5.796
a = 1.553

Answer

a = 1.553
2.Complex numbers

Answer: Im(z₀) = 1.286

De Moivre and roots: (r∠θ)ⁿ = rⁿ∠nθ. The equation zⁿ = R∠φ has exactly n roots, all with modulus R1/n, at the arguments (φ + 360°·k)/n for k = 0, 1, …, n − 1: they lie evenly spaced on a circle, 360°/n apart. A quadratic z² + pz + q = 0 with p² < 4q has the complex roots z = −p/2 ± j√(q − p²/4); a polynomial with real coefficients always has its complex roots in conjugate pairs a ± jb.

Modulus of the roots

81/3 = 2

Argument of the root

θ₀ = (120° + 360°·0)/3 = 40°

Rectangular form

z₀ = 2·(cos 40° + j sin 40°) = 1.532 + j1.286
Im(z₀) = 1.286

Answer

Im(z₀) = 1.286

The 3 roots lie on the circle of radius 2, 120° apart.

3.AC impedance & phasors

Answer: I = 2.109 A

AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.

Reactances

ω = 2πf = 2π·200 = 1257 rad/s
XL = ωL = 1257·0.05 = 62.83 Ω
XC = 1/(ωC) = 1/(1257·100·10⁻⁶) = 7.958 Ω

Impedance

In series the impedances add as complex numbers: Z = R + j(XL − XC).

|Z| = √(R² + (XL − XC)²) = √(15² + (54.87)²) = 56.89 Ω

Current

The same current flows through every element of a series circuit.

I = V/|Z| = 120/56.89 = 2.109 A

Answer

I = 2.109 A
4.AC impedance & phasors

Answer: VC = 9.55 V

AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.

Reactances

ω = 2πf = 2π·60 = 377 rad/s
XL = ωL = 377·0.25 = 94.25 Ω
XC = 1/(ωC) = 1/(377·47·10⁻⁶) = 56.44 Ω

Impedance

In series the impedances add as complex numbers: Z = R + j(XL − XC).

|Z| = √(R² + (XL − XC)²) = √(60² + (37.81)²) = 70.92 Ω

Current

The same current flows through every element of a series circuit.

I = V/|Z| = 12/70.92 = 0.1692 A

Voltage across the capacitor

VC = I·XC = 0.1692·56.44 = 9.55 V

Answer

VC = 9.55 V
5.AC power & power factor

Answer: I = 191.3 A

AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.

Reactive power of each load

A lagging load takes reactive power (Q > 0); a leading load supplies it (Q < 0).

Q1 = 27·tan(arccos 0.75) = 23.81 kvar
Q2 = 0 = 0 kvar

Totals

P = 27 + 10 = 37 kW
Q = 23.81 + 0 = 23.81 kvar
S = √(37² + 23.81²) = 44 kVA

Total current

I = S/V = 44000/230 = 191.3 A

Answer

I = 191.3 A
6.AC power & power factor

Answer: ΔP = 89.63 kW

AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.

Reactive power of the existing load

Q1 = 49·tan(arccos 0.65) = 57.29 kvar

Largest total real power

At full rating S = Smax, and Q is unchanged by the resistive load.

P = √(Smax² − Q1²) = √(150² − 57.29²) = 138.6 kW

Extra real power

ΔP = 138.6 − 49 = 89.63 kW

Answer

ΔP = 89.63 kW
7.LC resonance, Q factor & bandwidth

Answer: Q = 5

Q factor and bandwidth: in a resonant circuit Q = 2π·(energy stored)/(energy lost per cycle). For series RLC Q = ω0L/R = (1/R)√(L/C); for parallel RLC Q = R/(ω0L) = R√(C/L). The bandwidth between the half-power frequencies f1 and f2 (where the power is half and the current or voltage 1/√2 of its peak) is BW = f2 − f1 = f0/Q, which is R/(2πL) in series and 1/(2πRC) in parallel. The resonance frequency is the geometric mean f0 = √(f1f2), and f1,2 = f0(√(1 + 1/(4Q²)) ∓ 1/(2Q)). Losses also make the oscillation decay: in series RLC the amplitude falls as e−Rt/(2L).

Characteristic impedance

√(L/C) = √(2.2 × 10⁻⁵/2.2 × 10⁻⁷) = 10 Ω

Quality factor

Q = 10/2 = 5

Answer

Q = 5

The resonance frequency is 72.34 kHz, so BW = f₀/Q = 14.47 kHz.

8.LC resonance, Q factor & bandwidth

Answer: Q = 20.49

Q factor and bandwidth: in a resonant circuit Q = 2π·(energy stored)/(energy lost per cycle). For series RLC Q = ω0L/R = (1/R)√(L/C); for parallel RLC Q = R/(ω0L) = R√(C/L). The bandwidth between the half-power frequencies f1 and f2 (where the power is half and the current or voltage 1/√2 of its peak) is BW = f2 − f1 = f0/Q, which is R/(2πL) in series and 1/(2πRC) in parallel. The resonance frequency is the geometric mean f0 = √(f1f2), and f1,2 = f0(√(1 + 1/(4Q²)) ∓ 1/(2Q)). Losses also make the oscillation decay: in series RLC the amplitude falls as e−Rt/(2L).

Resonance frequency

f0 = √(50000·52500) = 51235 Hz

Bandwidth

BW = 52500 − 50000 = 2500 Hz

Quality factor

Q = 51235/2500 = 20.49

Answer

Q = 20.49
9.Three-phase power

Answer: P = 46.77 kW

Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ.

Apparent power

S = √3·VL·IL = √3·480·75 = 62.35 kVA

Real power

P = S·cos φ = 62.35·0.75 = 46.77 kW

Answer

P = 46.77 kW
10.Three-phase power

Answer: Cph = 686.7 µF

Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ. Power factor correction: capacitors supply reactive power locally, QC = P·(tan φ1 − tan φ2). Each of the three capacitors supplies QC/3 = V²·ω·C, where V is the voltage across that capacitor: VL in a Δ bank, VL/√3 in a Y bank.

Reactive power before and after

The real power is unchanged, so each power factor fixes the reactive power: Q = P·tan φ.

Q1 = 60·tan(acos 0.65) = 60·1.169 = 70.15 kvar
Q2 = 60·tan(acos 0.92) = 60·0.426 = 25.56 kvar

Reactive power from the capacitors

QC = Q1 − Q2 = 44.59 kvar

Capacitance per phase

In a Y bank each capacitor is connected between a line and the star point.

V = 415/√3 = 239.6 V, ω = 2π·60 = 377 rad/s
Cph = (QC/3)/(ω·V²) = 14863/(377·239.6²) = 686.7 µF

Answer

Cph = 686.7 µF
11.RC & RL transients

Answer: W = 6.894 mJ

First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.

Time constant and final current

Long after the switch closes the inductor behaves like a short circuit, so the final current is set by R alone.

τ = L/R = 220 mH / 22 Ω = 10 ms
i(∞) = Vs/R = 6/22 = 0.2727 A

Current at the given time

i(t) = 0.2727·(1 − e−25/10) = 0.2503 A

Stored energy

W = ½·L·i² = ½·220·0.2503² = 6.894 mJ

Answer

W = 6.894 mJ
12.RC & RL transients

Answer: vC = 2.775 V

First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.

Initial capacitor voltage

In steady state the capacitor is an open circuit, so R₁ and R₂ form a voltage divider. The capacitor voltage cannot jump when the switch opens.

vC(0) = 9·4.7/(4.7 + 4.7) = 4.5 V

Time constant after the switch opens

τ = R2·C = 4.7·220 = 1034 ms

Discharge

vC(t) = 4.5·e−500/1034 = 2.775 V

Answer

vC = 2.775 V
13.Thévenin & Norton

Answer: Vth = 5 V

Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.

R1​ = 8 ΩR3​ = 8 ΩSHORTR2​4 ΩAabRth​

Find Rth with every source switched off

Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.

R1 ∥ R2 = 8·4/(8+4) = 2.667 Ω
Rth = (R1 ∥ R2) + R3 = 2.667 + 8 = 10.67 Ω
R1​ = 8 ΩR3​ = 8 Ω+−V1​15 VR2​4 ΩAab+−Vth​

Find Vth, the open-circuit voltage

With a–b open, no current flows through R₃, so there is no drop across it and V_b = V_A. R₁ and R₂ form a voltage divider.

Vth = V1·R2/(R1+R2) = 15·4/(8+4) = 5 V
14.Thévenin & Norton

Answer: PL = 1.033 W

Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.

R1​ = 4 ΩR3​ = 6 ΩSHORTR2​8 ΩAOPENBabRth​

Find Rth with every source switched off

Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.

R1 ∥ R2 = 4·8/(4+8) = 2.667 Ω
Rth = (R1 ∥ R2) + R3 = 2.667 + 6 = 8.667 Ω
R1​ = 4 ΩR3​ = 6 Ω+−V1​18 VR2​8 ΩAIs​0.5 ABab+−Vth​

Find Vth, the open-circuit voltage

With a–b open, the only path for Iₛ is through R₃ into node A. Find V_A by superposition of V₁ and Iₛ, then add the drop across R₃.

VA = V1·R2/(R1+R2) + Is·(R1∥R2) = 12 + (−0.5)·2.667 = 10.67 V
Vth = VB = VA + Is·R3 = 10.67 + (−0.5)·6 = 7.667 V
Rth​ = 8.667 Ω+−Vth​7.667 VRL​2 ΩIL​

Connect the load to the Thévenin equivalent

The Thévenin source and R_th in series behave exactly like the original circuit at a–b, so the load sees a simple series loop.

IL = Vth/(Rth + RL) = 7.667/(8.667 + 2) = 0.7188 A
PL = IL²·RL = 0.7188²·2 = 1.033 W
15.Bode plots & margins

Answer: φ = 76.03 °

Frequency response: substitute s = jω in the transfer function. The magnitude in decibels is 20·log₁₀|H(jω)| and the phase is the sum of the angles of the numerator factors minus those of the denominator factors. A first-order RC or RL filter has its corner (−3 dB) frequency at ωc = 1/(RC) or R/L, and fc = ωc/(2π); a low-pass filter gives |H| = 1/√(1 + (ω/ωc)²) and φ = −atan(ω/ωc). In the asymptotic (straight-line) Bode plot each pole bends the magnitude down by 20 dB/decade at its corner frequency, each zero bends it up by 20 dB/decade, and an integrator 1/s gives −20 dB/decade at all frequencies. Gain crossover ωc: |L(jω)| = 1 (0 dB); phase margin PM = 180° + ∠L(jωc). Phase crossover ω180: ∠L(jω) = −180°; gain margin GM = −20·log₁₀|L(jω180)| dB. The closed loop is stable when both margins are positive.

Corner frequency

ωc = R/L = 100/0.022 = 4545 rad/s
fc = 723.4 Hz → f/fc = 180/723.4 = 0.2488

Phase

φ = 90° − atan(0.2488) = 76.03°

Answer

φ = 76.03°
16.Bode plots & margins

Answer: GM = 20.13 dB

Frequency response: substitute s = jω in the transfer function. The magnitude in decibels is 20·log₁₀|H(jω)| and the phase is the sum of the angles of the numerator factors minus those of the denominator factors. A first-order RC or RL filter has its corner (−3 dB) frequency at ωc = 1/(RC) or R/L, and fc = ωc/(2π); a low-pass filter gives |H| = 1/√(1 + (ω/ωc)²) and φ = −atan(ω/ωc). In the asymptotic (straight-line) Bode plot each pole bends the magnitude down by 20 dB/decade at its corner frequency, each zero bends it up by 20 dB/decade, and an integrator 1/s gives −20 dB/decade at all frequencies. Gain crossover ωc: |L(jω)| = 1 (0 dB); phase margin PM = 180° + ∠L(jωc). Phase crossover ω180: ∠L(jω) = −180°; gain margin GM = −20·log₁₀|L(jω180)| dB. The closed loop is stable when both margins are positive.

Phase crossover

(ω/3)·(ω/8) = 1 → ω180 = √(3·8) = 4.899 rad/s

Magnitude at phase crossover

|L(jω180)| = K/(ω·√(ω² + 9)·√(ω² + 64)) = K/(3·8·(3 + 8)) = K/264

Gain margin

GM = 20·log₁₀(264/26) = 20.13 dB

Answer

GM = 20.13 dB

ExamProblems · examproblems.com/courses/circuit-analysis-2