Circuit Analysis 2: AC circuits: cram pack

Formula sheets, the key method steps for every topic and 16 practice problems, with full solutions at the back.

New problemsBack to the course

In the print window, choose “Save as PDF” to keep a copy on your device.

1Formulas and methods

Complex numbers

Rectangular form
z = a + jb, j² = −1, z̄ = a − jb
Modulus and argument
|z| = √(a² + b²), tan θ = b/a (check the quadrant)
Polar and exponential form
z = r∠θ = r(cos θ + j sin θ) = r·ejθ
Division
z₁/z₂ = z₁z̄₂/|z₂|²
Product and quotient
r₁∠θ₁ · r₂∠θ₂ = r₁r₂∠(θ₁ + θ₂), r₁∠θ₁ / r₂∠θ₂ = (r₁/r₂)∠(θ₁ − θ₂)
De Moivre
(r∠θ)ⁿ = rⁿ∠nθ
n-th roots
zk = R1/n∠((φ + 360°·k)/n), k = 0 … n − 1
Quadratic with p² < 4q
z = −p/2 ± j√(q − p²/4)

Method

  1. Decide which form suits the operation: rectangular a + jb for adding and subtracting, polar r∠θ for multiplying, dividing, powers and roots.
  2. Multiply out with j² = −1; divide by multiplying the top and bottom by the conjugate of the denominator.
  3. Convert with r = √(a² + b²) and θ from a sketch of the point (check the quadrant), and back with a = r cos θ, b = r sin θ.
  4. For powers use De Moivre, (r∠θ)ⁿ = rⁿ∠nθ; for zⁿ = R∠φ list all n roots R1/n∠((φ + 360°k)/n).

AC impedance & phasors

Impedances
ZR = R, ZL = jωL, ZC = 1/(jωC)
Angular frequency
ω = 2πf
Magnitude and angle
|Z| = √(R² + X²), φ = atan(X/R)
Phasor Ohm’s law
V = I·Z

Method

  1. Convert the frequency: ω = 2πf.
  2. Find each reactance: XL = ωL and XC = 1/(ωC).
  3. Add impedances like resistors, with Z = R + jX.
  4. Find the magnitude |Z| = √(R² + X²) and the angle φ = atan(X/R), then use Ohm’s law with phasors.

AC power & power factor

Real power
P = V·I·cos φ
Reactive power
Q = V·I·sin φ
Apparent power
S = V·I = √(P² + Q²)
Power factor
pf = cos φ = P/S
Correction capacitor
QC = P(tan φ1 − tan φ2), C = QC/(ωV²)

LC resonance, Q factor & bandwidth

Natural frequency
ω0 = 1/√(LC), f0 = 1/(2π√(LC))
Energy
W = ½CV0² = ½Cv² + ½Li²
Peak current
Imax = V0√(C/L)
Quality factor
Q = 2π·(energy stored)/(energy lost per cycle)
Series RLC
Q = (1/R)√(L/C), BW = R/(2πL)
Parallel RLC
Q = R√(C/L), BW = 1/(2πRC)
Bandwidth
BW = f2 − f1 = f0/Q, f0 = √(f1f2)
Half-power frequencies
f1,2 = f0(√(1 + 1/(4Q²)) ∓ 1/(2Q))
Tank with coil resistance r
RD = L/(C·r) = Q²·r
Decay of the amplitude
e−Rt/(2L)

Method

  1. Find the resonance frequency first: ω₀ = 1/√(LC) and f₀ = ω₀/(2π).
  2. Decide whether the circuit is series or parallel: series Q = (1/R)√(L/C), parallel Q = R√(C/L).
  3. Use BW = f₀/Q for the bandwidth, or the shortcuts R/(2πL) (series) and 1/(2πRC) (parallel).
  4. For energy questions, use that the total energy ½CV₀² stays constant in an ideal LC circuit and swings between C and L every quarter period.

Three-phase power

Y connection
VL = √3·Vph, IL = Iph
Δ connection
VL = Vph, IL = √3·Iph
Total real power
P = √3·VL·IL·cos φ = 3·Iph²·R
Apparent and reactive power
S = √3·VL·IL, Q = P·tan φ
Correction capacitors
QC = P(tan φ1 − tan φ2), C = QC/(3ωV²)
Voltage across each capacitor
Δ: VL Y: VL/√3
Motor input
Pin = Pout/η

RC & RL transients

Time constant
τ = RC | τ = L/R
Response
x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ
Capacitor at DC
open circuit; vC cannot jump
Inductor at DC
short circuit; iL cannot jump
Settled
t ≈ 5τ

Method

  1. Find the initial value just after switching: a capacitor voltage and an inductor current cannot jump.
  2. Find the final value long after switching: a capacitor acts as an open circuit, an inductor as a short circuit.
  3. Find the time constant: τ = RC or τ = L/R, using the resistance seen by the capacitor or inductor.
  4. Use x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ.

Thévenin & Norton

Thévenin voltage
Vth = Vopen circuit
Thévenin resistance
Rth: all sources off, seen from a–b
Norton current
IN = Vth/Rth
Load current
IL = Vth/(Rth + RL)
Maximum power transfer
RL = Rth, Pmax = Vth²/(4Rth)

Method

  1. Remove the load and mark the two terminals a and b.
  2. Find the open-circuit voltage between a and b: this is Vth.
  3. Switch off all independent sources and find the resistance seen from a–b: this is Rth.
  4. Put the load back on the equivalent circuit: Vth in series with Rth.
  5. For the Norton equivalent, convert: IN = Vth/Rth, with RN = Rth in parallel.

2Practice problems

1.Complex numbersMedium
ReIm55−5−5θz

Find the argument θ of z = −4 + j7 in degrees, as the principal value between −180° and 180°.

z = −4 + j7
θ = °
2.Complex numbersHard
ReIm11−1−122−2−2z₁z₂

Solve z² + 5z + 7.25 = 0. The roots are a ± jb; find the real part a.

p = 5q = 7.25
a =
3.AC impedance & phasorsMedium
50 V60 HzR = 20 ΩL = 50 mHC = 47 µFI

A series RLC circuit is connected to a 50 V (rms), 60 Hz supply. Find the power factor cos φ of the circuit.

V = 50 V (rms)f = 60 HzR = 20 ΩL = 50 mHC = 47 µF
cos φ =
4.AC impedance & phasorsHard
5 Vf0​R = 10 ΩL = 10 mHC = 10 µF

A series RLC circuit is driven by a 5 V (rms) source whose frequency is set to the resonant frequency of the circuit. Find the rms voltage VL across the inductor.

V = 5 V (rms)R = 10 ΩL = 10 mHC = 10 µF
VL = V
5.AC power & power factorMedium
230 VR + jXP = 949 W5.5 A

An inductive load takes 5.5 A and 949 W from a 230 V (rms) single-phase supply. Model it as a resistance R in series with a reactance X. Find R.

V = 230 VI = 5.5 AP = 949 W
R = Ω
6.AC power & power factorHard
P = 10 kWQ1​S1​φ1​QC​

A single-phase load takes 10 kW at a power factor of 0.7 lagging from a 400 V, 50 Hz supply. A capacitor connected in parallel raises the power factor to 0.95. Find the new line current Inew.

P = 10 kWpf1 = 0.7pf2 = 0.95V = 400 Vf = 50 Hz
Inew = A
7.LC resonance, Q factor & bandwidthMedium
V10 Ω100 mH47 nF

A series RLC circuit has R = 10 Ω, L = 100 mH and C = 47 nF. Find its bandwidth BW in Hz.

R = 10 ΩL = 100 mHC = 47 nF
BW = Hz
8.LC resonance, Q factor & bandwidthHard
C = 220 nFR = 2 ΩL = 10 mH

A charged 220 nF capacitor discharges through a 10 mH coil with a total series resistance of 2 Ω, so the oscillation slowly dies out. Its amplitude decays as e−Rt/(2L). How many oscillation cycles n pass before the amplitude has halved? (The losses are small, so the frequency is f₀.)

L = 10 mHC = 220 nFR = 2 Ω
n =
9.Three-phase powerMedium
ABCVL​ = 690 VIL​ = 75 Acos φ = 0.82lagging

A balanced three-phase load draws a line current of 75 A from a supply with a line-to-line voltage of 690 V. The power factor is 0.82 lagging. Find the total real power P drawn by the load in kW.

VL = 690 VIL = 75 Acos φ = 0.82
P = kW
10.Three-phase powerHard
P = 200 kWφ1​S1​Q2​QC​ = ?

A balanced three-phase load takes 200 kW at a power factor of 0.75 lagging from a 400 V (line-to-line), 60 Hz supply. A three-phase capacitor bank in parallel with the load must raise the overall power factor to 0.98 lagging. The real power stays the same. Find the total reactive power QC the capacitor bank must supply, in kvar.

P = 200 kWpf1 = 0.75pf2 = 0.98VL = 400 Vf = 60 Hz
QC = kvar
11.RC & RL transientsMedium
+−Vs​12 Vt = 0R = 50 ΩL22 mHi(t)

The inductor carries no current before the switch closes at t = 0. How long after the switch closes does the current reach 80% of its final value? Find t.

Vs = 12 VR = 50 ΩL = 22 mH
t = ms
12.RC & RL transientsHard
+−Vs​20 Vopens at t = 0R1​ = 10 kΩR2​ = 1 kΩC100 µF+−vC​

The switch has been closed for a long time, so the circuit is in steady state. At t = 0 the switch opens. Find the capacitor voltage vC at t = 30 ms.

Vs = 20 VR1 = 10 kΩR2 = 1 kΩC = 100 µFt = 30 ms
vC = V
13.Thévenin & NortonMedium
R1​ = 2 ΩR3​ = 4 Ω+−V1​9 VR2​4 ΩAab

Find the Thévenin voltage Vth seen from terminals a–b.

V1 = 9 VR1 = 2 ΩR2 = 4 ΩR3 = 4 Ω
Vth = V
14.Thévenin & NortonHard
R1​ = 4 ΩR3​ = 15 Ω+−V1​9 VR2​10 ΩAIs​4 ABab

Find the Thévenin voltage Vth seen from terminals a–b.

V1 = 9 VIs = 4 AR1 = 4 ΩR2 = 10 ΩR3 = 15 Ω
Vth = V
15.Bode plots & marginsMedium
|H| (dB)0.010.1110100−40−20020ω (rad/s)ω = 0.5

Find the exact magnitude |G(jω)| of G(s) = 270/((s + 5)(s + 6)) at ω = 0.5 rad/s, in dB.

G(s) = 270/((s + 5)(s + 6))ω = 0.5 rad/s
|G(jω)| = dB
16.Bode plots & marginsHard
|H| (dB)0.10.1111010100100−60−40−200204060ω (rad/s)φ (°)ω (rad/s)−270−180−900ω180​

A unity-feedback loop has the open-loop transfer function L(s) = 842/(s(s + 7)(s + 10)). Find the gain margin GM in dB.

L(s) = 842/(s(s + 7)(s + 10))
GM = dB

3Solutions

1.Complex numbers

Answer: θ = 119.7 °

Polar form: z = r∠θ = r(cos θ + j sin θ) = r·ejθ, with r = |z| and θ = arg z. Back to rectangular form: a = r cos θ, b = r sin θ. The argument needs the quadrant: θ = atan(b/a) only when a > 0; for a < 0 add or subtract 180°. In polar form multiplication is easy: multiply the moduli and add the arguments; for division divide the moduli and subtract the arguments.

Quadrant

a = −4, b = 7 → II

Reference angle

α = atan(7/4) = 60.26°

Argument

θ = 180° − α = 119.7°

Answer

θ = 119.7°

In polar form z = 8.062∠119.7°.

2.Complex numbers

Answer: a = −2.5

De Moivre and roots: (r∠θ)ⁿ = rⁿ∠nθ. The equation zⁿ = R∠φ has exactly n roots, all with modulus R1/n, at the arguments (φ + 360°·k)/n for k = 0, 1, …, n − 1: they lie evenly spaced on a circle, 360°/n apart. A quadratic z² + pz + q = 0 with p² < 4q has the complex roots z = −p/2 ± j√(q − p²/4); a polynomial with real coefficients always has its complex roots in conjugate pairs a ± jb.

Discriminant

p² − 4q = 25 − 29 = −4 < 0

Quadratic formula

z = (−5 ± j√4)/2 = −2.5 + j, −2.5 − j

Answer

a = −2.5

Answer

a = −2.5
3.AC impedance & phasors

Answer: cos φ = 0.4697

AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.

Reactances

XL = 18.85 Ω, XC = 56.44 Ω

Impedance

|Z| = √(20² + (−37.59)²) = 42.58 Ω

Power factor

cos φ = R/|Z| = 20/42.58 = 0.4697
The circuit is capacitive, so the power factor is leading.

Answer

cos φ = 0.4697
4.AC impedance & phasors

Answer: VL = 15.81 V

AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.

Resonance

At resonance the reactances cancel, so the impedance is just R.

ω₀ = 1/√(LC) = 1/√(0.01·10·10⁻⁶) = 3162 rad/s
I = V/R = 5/10 = 0.5 A

Voltage across the inductor

XL = ω₀L = 3162·0.01 = 31.62 Ω
VL = I·XL = 0.5·31.62 = 15.81 V

Answer

VL = 15.81 V

This is Q = 3.162 times the supply voltage.

5.AC power & power factor

Answer: R = 31.37 Ω

AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.

Resistance from the real power

R = P/I² = 949/5.5² = 31.37 Ω

Answer

R = 31.37 Ω
6.AC power & power factor

Answer: Inew = 26.32 A

AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.

Reactive power before and after

The real power P does not change; only the reactive power drawn from the supply does.

Q1 = P·tan φ1 = 10·tan(45.57°) = 10.2 kvar
Q2 = P·tan φ2 = 10·tan(18.19°) = 3.287 kvar
QC = Q1 − Q2 = 6.915 kvar

New line current

Inew = P/(V·cos φ2) = 10000/(400·0.95) = 26.32 A

Answer

Inew = 26.32 A
7.LC resonance, Q factor & bandwidth

Answer: BW = 15.92 Hz

Q factor and bandwidth: in a resonant circuit Q = 2π·(energy stored)/(energy lost per cycle). For series RLC Q = ω0L/R = (1/R)√(L/C); for parallel RLC Q = R/(ω0L) = R√(C/L). The bandwidth between the half-power frequencies f1 and f2 (where the power is half and the current or voltage 1/√2 of its peak) is BW = f2 − f1 = f0/Q, which is R/(2πL) in series and 1/(2πRC) in parallel. The resonance frequency is the geometric mean f0 = √(f1f2), and f1,2 = f0(√(1 + 1/(4Q²)) ∓ 1/(2Q)). Losses also make the oscillation decay: in series RLC the amplitude falls as e−Rt/(2L).

Bandwidth in rad/s

R/L = 10/0.1 = 100 rad/s

Bandwidth in Hz

BW = 100/(2π) = 15.92 Hz = 15.92 Hz

Answer

BW = 15.92 Hz

With f₀ = 2.322 kHz this gives Q = 145.9.

8.LC resonance, Q factor & bandwidth

Answer: n = 23.52

Q factor and bandwidth: in a resonant circuit Q = 2π·(energy stored)/(energy lost per cycle). For series RLC Q = ω0L/R = (1/R)√(L/C); for parallel RLC Q = R/(ω0L) = R√(C/L). The bandwidth between the half-power frequencies f1 and f2 (where the power is half and the current or voltage 1/√2 of its peak) is BW = f2 − f1 = f0/Q, which is R/(2πL) in series and 1/(2πRC) in parallel. The resonance frequency is the geometric mean f0 = √(f1f2), and f1,2 = f0(√(1 + 1/(4Q²)) ∓ 1/(2Q)). Losses also make the oscillation decay: in series RLC the amplitude falls as e−Rt/(2L).

Half-life of the amplitude

t = 2·0.01·ln 2/2 = 0.006931 s

Number of cycles

n = t·f0 = 0.006931·3393 = 23.52

Answer

n = 23.52

Shortcut: n = Q·ln 2/π with Q = 106.6.

9.Three-phase power

Answer: P = 73.5 kW

Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ.

Apparent power

S = √3·VL·IL = √3·690·75 = 89.63 kVA

Real power

P = S·cos φ = 89.63·0.82 = 73.5 kW

Answer

P = 73.5 kW
10.Three-phase power

Answer: QC = 135.8 kvar

Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ. Power factor correction: capacitors supply reactive power locally, QC = P·(tan φ1 − tan φ2). Each of the three capacitors supplies QC/3 = V²·ω·C, where V is the voltage across that capacitor: VL in a Δ bank, VL/√3 in a Y bank.

Reactive power before and after

The real power is unchanged, so each power factor fixes the reactive power: Q = P·tan φ.

Q1 = 200·tan(acos 0.75) = 200·0.8819 = 176.4 kvar
Q2 = 200·tan(acos 0.98) = 200·0.2031 = 40.61 kvar

Reactive power from the capacitors

QC = Q1 − Q2 = 135.8 kvar

Answer

QC = 135.8 kvar
11.RC & RL transients

Answer: t = 0.7082 ms

First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.

Time constant and final current

Long after the switch closes the inductor behaves like a short circuit, so the final current is set by R alone.

τ = L/R = 22 mH / 50 Ω = 0.44 ms
i(∞) = Vs/R = 12/50 = 0.24 A

Solve for the time

0.8 = 1 − e−t/τ → t = −τ·ln(1 − 0.8)
t = −0.44·ln(0.2) = 0.7082 ms

Answer

t = 0.7082 ms
12.RC & RL transients

Answer: vC = 1.347 V

First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.

Initial capacitor voltage

In steady state the capacitor is an open circuit, so R₁ and R₂ form a voltage divider. The capacitor voltage cannot jump when the switch opens.

vC(0) = 20·1/(10 + 1) = 1.818 V

Time constant after the switch opens

τ = R2·C = 1·100 = 100 ms

Discharge

vC(t) = 1.818·e−30/100 = 1.347 V

Answer

vC = 1.347 V
13.Thévenin & Norton

Answer: Vth = 6 V

Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.

R1​ = 2 ΩR3​ = 4 ΩSHORTR2​4 ΩAabRth​

Find Rth with every source switched off

Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.

R1 ∥ R2 = 2·4/(2+4) = 1.333 Ω
Rth = (R1 ∥ R2) + R3 = 1.333 + 4 = 5.333 Ω
R1​ = 2 ΩR3​ = 4 Ω+−V1​9 VR2​4 ΩAab+−Vth​

Find Vth, the open-circuit voltage

With a–b open, no current flows through R₃, so there is no drop across it and V_b = V_A. R₁ and R₂ form a voltage divider.

Vth = V1·R2/(R1+R2) = 9·4/(2+4) = 6 V
14.Thévenin & Norton

Answer: Vth = 77.86 V

Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.

R1​ = 4 ΩR3​ = 15 ΩSHORTR2​10 ΩAOPENBabRth​

Find Rth with every source switched off

Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.

R1 ∥ R2 = 4·10/(4+10) = 2.857 Ω
Rth = (R1 ∥ R2) + R3 = 2.857 + 15 = 17.86 Ω
R1​ = 4 ΩR3​ = 15 Ω+−V1​9 VR2​10 ΩAIs​4 ABab+−Vth​

Find Vth, the open-circuit voltage

With a–b open, the only path for Iₛ is through R₃ into node A. Find V_A by superposition of V₁ and Iₛ, then add the drop across R₃.

VA = V1·R2/(R1+R2) + Is·(R1∥R2) = 6.429 + 4·2.857 = 17.86 V
Vth = VB = VA + Is·R3 = 17.86 + 4·15 = 77.86 V
15.Bode plots & margins

Answer: |G(jω)| = 19.01 dB

Frequency response: substitute s = jω in the transfer function. The magnitude in decibels is 20·log₁₀|H(jω)| and the phase is the sum of the angles of the numerator factors minus those of the denominator factors. A first-order RC or RL filter has its corner (−3 dB) frequency at ωc = 1/(RC) or R/L, and fc = ωc/(2π); a low-pass filter gives |H| = 1/√(1 + (ω/ωc)²) and φ = −atan(ω/ωc). In the asymptotic (straight-line) Bode plot each pole bends the magnitude down by 20 dB/decade at its corner frequency, each zero bends it up by 20 dB/decade, and an integrator 1/s gives −20 dB/decade at all frequencies. Gain crossover ωc: |L(jω)| = 1 (0 dB); phase margin PM = 180° + ∠L(jωc). Phase crossover ω180: ∠L(jω) = −180°; gain margin GM = −20·log₁₀|L(jω180)| dB. The closed loop is stable when both margins are positive.

Multiply the magnitudes

|G(j0.5)| = 270/(√(0.5² + 5²)·√(0.5² + 6²)) = 270/(5.025·6.021) = 8.924

Result

20·log₁₀(8.924) = 19.01 dB

Answer

|G(jω)| = 19.01 dB
16.Bode plots & margins

Answer: GM = 3.005 dB

Frequency response: substitute s = jω in the transfer function. The magnitude in decibels is 20·log₁₀|H(jω)| and the phase is the sum of the angles of the numerator factors minus those of the denominator factors. A first-order RC or RL filter has its corner (−3 dB) frequency at ωc = 1/(RC) or R/L, and fc = ωc/(2π); a low-pass filter gives |H| = 1/√(1 + (ω/ωc)²) and φ = −atan(ω/ωc). In the asymptotic (straight-line) Bode plot each pole bends the magnitude down by 20 dB/decade at its corner frequency, each zero bends it up by 20 dB/decade, and an integrator 1/s gives −20 dB/decade at all frequencies. Gain crossover ωc: |L(jω)| = 1 (0 dB); phase margin PM = 180° + ∠L(jωc). Phase crossover ω180: ∠L(jω) = −180°; gain margin GM = −20·log₁₀|L(jω180)| dB. The closed loop is stable when both margins are positive.

Phase crossover

(ω/7)·(ω/10) = 1 → ω180 = √(7·10) = 8.367 rad/s

Magnitude at phase crossover

|L(jω180)| = K/(ω·√(ω² + 49)·√(ω² + 100)) = K/(7·10·(7 + 10)) = K/1190

Gain margin

GM = 20·log₁₀(1190/842) = 3.005 dB

Answer

GM = 3.005 dB

ExamProblems · examproblems.com/courses/circuit-analysis-2