In the print window, choose “Save as PDF” to keep a copy on your device.
1Formulas and methods
Stability: Routh–Hurwitz & root locus
Stability
all roots of the characteristic polynomial in the left half-plane
Routh array, s¹ entry of a cubic
b1 = (a2a1 − a3a0)/a2
Right half-plane roots
number of sign changes in the first column
Cubic s³ + a₂s² + a₁s + a₀
stable when all a > 0 and a₂·a₁ > a₀
K/(s(s + a)(s + b))
Kmax = ab(a + b), ω = √(ab)
Characteristic equation
1 + K·G(s) = 0
Asymptotes
σa = (Σp − Σz)/(n − m), θ = (2q + 1)·180°/(n − m)
Break-away and break-in points
dK/ds = 0
Magnitude condition
K = 1/|G(s)|
Angle of departure
θd = 180° − Σ∠(from other poles) + Σ∠(from zeros)
Method
Write the closed-loop characteristic polynomial: the denominator of 1 + K·G(s) = 0, multiplied out.
Put the coefficients alternately into the first two rows of the Routh array and build the remaining rows.
Count the sign changes in the first column: each one is a pole in the right half-plane. With K in the array, demand that every first-column entry stays positive.
For a root locus, mark the poles and zeros, the real-axis segments, the asymptotes from the centroid and the break points where dK/ds = 0. Use K = 1/|G(s)| for the gain at a point.
Steady-state error & PID control
System type
number of poles of G(s) at s = 0
Error constants
Kp = lim G(s), Kv = lim s·G(s), Ka = lim s²·G(s) (s → 0)
Step A
ess = A/(1 + Kp)
Ramp A·t
ess = A/Kv
Parabola A·t²/2
ess = A/Ka
PID controller
C(s) = Kp + Ki/s + Kd·s
Second-order target
s² + 2ζωns + ωn²
Overshoot and timing
%OS = 100·e−ζπ/√(1−ζ²), tp = π/ωd, ts ≈ 4/(ζωn)
Method
Count the poles of the open loop C(s)·G(s) at s = 0: that is the system type.
Work out the error constant that matches the input: Kp for a step, Kv for a ramp, Ka for a parabola.
Apply ess = A/(1 + Kp), A/Kv or A/Ka, or solve it for the gain you need.
For a damping or speed specification, write the closed-loop characteristic polynomial and match it with s² + 2ζω_n·s + ω_n².
2Practice problems
1.Laplace transformsMedium
Find f(t) for F(s) = (3s + 3)/(s² + 4s + 29) by completing the square, and evaluate f(0.75).
F(s) = (3s + 3)/(s² + 4s + 29)t = 0.75 s
f(0.75) =
2.Laplace transformsHard
A system is described by the differential equation y″ + 8y′ + 12y = 2u′ + 6u, with input u(t) and output y(t). Find its transfer function G(s) = Y(s)/U(s) (zero initial conditions) and evaluate the impulse response g(t) at t = 0.1 s. Find g(0.1).
y″ + 8y′ + 12y = 2u′ + 6ut = 0.1 s
g(0.1) =
3.Block diagramsMedium
A plant G(s) = 34/(s + 9) is controlled in a negative feedback loop whose sensor has the gain H = 0.5. Find the time constant τ of the closed loop.
G(s) = 34/(s + 9)H = 0.5
τ = s
4.Block diagramsHard
A proportional controller K = 28 drives the plant G(s) = 3/(s + 5) in a unity negative feedback loop. A disturbance D enters at the plant input (it is added to the controller output). With R = 0, a disturbance step of size 10 is applied. Find the steady-state output css.
K = 28G(s) = 3/(s + 5)D = 10R = 0
css =
5.Step responseMedium
A system has the transfer function G(s) = 11/(s² + 4s + 11) and receives a unit step input. Find the damping ratio ζ.
G(s) = 11/(s² + 4s + 11)
ζ =
6.Step responseHard
A mass m = 20 kg hangs on a spring k = 400 N/m with a viscous damper c = 107 N·s/m (m·x″ + c·x′ + k·x = F). At rest in equilibrium, a constant force F = 100 N is suddenly applied. Find the percent overshoot %OS of the displacement.
m = 20 kgk = 400 N/mc = 107 N·s/mF = 100 N
%OS = %
7.Stability: Routh–Hurwitz & root locusMedium
The loop in the diagram has the open-loop transfer function L(s) = K/(s(s + 3)(s + 5)). Find the largest gain Kmax for which the closed loop is stable.
L(s) = K/(s(s + 3)(s + 5))
Kmax =
8.Stability: Routh–Hurwitz & root locusHard
The root locus of L(s) = K(s + 10)/(s(s + 4)) leaves the real axis between s = 0 and s = −4, circles round and joins the real axis again to the left of the zero. Find the break-in point si.
L(s) = K(s + 10)/(s(s + 4))
si =
9.Steady-state error & PID controlMedium
The input r(t) = 10 + 1t (a step plus a ramp) is applied to a unity-feedback loop with G(s) = 50/(s(s + 5)). Find the steady-state error ess.
G(s) = 50/(s(s + 5))r(t) = 10 + 1t
ess =
10.Steady-state error & PID controlHard
A PI controller C(s) = 5 + 4/s drives the plant G(s) = 10/((s + 1)(s + 4)) in a unity-feedback loop. Find the steady-state error ess for the ramp input r(t) = 5t.
C(s) = 5 + 4/sG(s) = 10/((s + 1)(s + 4))r(t) = 5t
ess =
11.Bode plots & marginsMedium
In the series RLC band-pass filter shown the output is taken across R = 10 Ω, with L = 5 mH and C = 1 µF. Find the −3 dB bandwidth BW in Hz.
R = 10 ΩL = 5 mHC = 1 µF
BW = Hz
12.Bode plots & marginsHard
A unity-feedback loop has the open-loop transfer function L(s) = 25/(s(s + 5)). Find the phase margin PM in degrees.
L(s) = 25/(s(s + 5))
PM = °
3Solutions
1.Laplace transforms
Answer: f(0.75) = −0.4728
Laplace transform: F(s) = ∫₀∞ f(t)·e−st dt turns derivatives into multiplications by s: ℒ{f′} = sF(s) − f(0), ℒ{f″} = s²F(s) − s·f(0) − f′(0). Standard pairs: 1 ↔ 1/s, e−at ↔ 1/(s + a), t·e−at ↔ 1/(s + a)², sin ωt ↔ ω/(s² + ω²), cos ωt ↔ s/(s² + ω²), and a shift s → s + σ multiplies the time function by e−σt. To invert a rational F(s), split it into partial fractions: the residue of a simple pole p is A = [(s − p)·F(s)] at s = p. Final value theorem: f(∞) = lims→0 s·F(s), valid only when all poles of s·F(s) lie in the left half-plane. Initial value theorem: f(0⁺) = lims→∞ s·F(s).
Laplace transform: F(s) = ∫₀∞ f(t)·e−st dt turns derivatives into multiplications by s: ℒ{f′} = sF(s) − f(0), ℒ{f″} = s²F(s) − s·f(0) − f′(0). Standard pairs: 1 ↔ 1/s, e−at ↔ 1/(s + a), t·e−at ↔ 1/(s + a)², sin ωt ↔ ω/(s² + ω²), cos ωt ↔ s/(s² + ω²), and a shift s → s + σ multiplies the time function by e−σt. To invert a rational F(s), split it into partial fractions: the residue of a simple pole p is A = [(s − p)·F(s)] at s = p. Final value theorem: f(∞) = lims→0 s·F(s), valid only when all poles of s·F(s) lie in the left half-plane. Initial value theorem: f(0⁺) = lims→∞ s·F(s).
Transfer function
G(s) = Y(s)/U(s) = (2s + 6)/(s² + 8s + 12)
Partial fractions
s² + 8s + 12 = (s + 2)(s + 6)
A = 0.5, B = 1.5
Impulse response
g(t) = 0.5·e−2t + 1.5·e−6t
g(0.1) = 1.233
Answer
g(0.1) = 1.233
3.Block diagrams
Answer: τ = 0.03846 s
Block-diagram algebra: blocks in series multiply (G₁·G₂), blocks in parallel add (G₁ + G₂), and a loop with forward path G and feedback path H reduces to T = G/(1 + G·H) for negative feedback and G/(1 − G·H) for positive feedback. Reduce inner loops first, then work outwards. The closed-loop poles are the roots of the characteristic equation 1 + G(s)H(s) = 0. For a stable loop, a step input of size A gives the steady-state output A·T(0); with unity feedback the steady-state error to a step is A/(1 + Kp) with Kp = G(0).
Block-diagram algebra: blocks in series multiply (G₁·G₂), blocks in parallel add (G₁ + G₂), and a loop with forward path G and feedback path H reduces to T = G/(1 + G·H) for negative feedback and G/(1 − G·H) for positive feedback. Reduce inner loops first, then work outwards. The closed-loop poles are the roots of the characteristic equation 1 + G(s)H(s) = 0. For a stable loop, a step input of size A gives the steady-state output A·T(0); with unity feedback the steady-state error to a step is A/(1 + Kp) with Kp = G(0).
Transfer functions
C/D = G/(1 + K·G) = 3/(s + 5 + 84)
Steady state
css = 10·3/89 = 0.3371
Answer
css = 0.3371
A larger K reduces the effect of the disturbance, but never to zero with a proportional controller.
5.Step response
Answer: ζ = 0.603
Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).
Compare with the standard form
The denominator must match s² + 2ζωₙs + ωₙ².
ωₙ² = 11 → ωₙ = 3.317 rad/s
2ζωₙ = 4 → ζ = 4/(2·3.317) = 0.603
Result
ζ = 0.603
Answer
ζ = 0.603
6.Step response
Answer: %OS = 9.586 %
Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).
Natural frequency and damping ratio
ωₙ = √(k/m) = √(400/20) = 4.472 rad/s
ζ = c/(2√(km)) = 107/(2·√(400·20)) = 0.5981
Result
%OS = 100·e−ζπ/√(1−ζ²) = 9.586 %
Answer
%OS = 9.586 %
7.Stability: Routh–Hurwitz & root locus
Answer: Kmax = 120
Routh–Hurwitz criterion: a linear system is stable when every root of its characteristic polynomial lies in the left half of the s-plane. Write the coefficients alternately into the first two rows of the Routh array. Each entry of a new row comes from the two rows above it; for a cubic a₃s³ + a₂s² + a₁s + a₀ the s¹ entry is b₁ = (a₂·a₁ − a₃·a₀)/a₂. The number of sign changes in the first column equals the number of roots in the right half-plane. With a gain K in the coefficients, every first-column entry must stay positive: the gain that makes the s¹ entry zero is the stability limit, and the s² row then gives the frequency of the sustained oscillation.
Characteristic equation
s³ + 8s² + 15s + K = 0
Routh array
s³: 1, 15
s²: 8, K
s¹: (8·15 − K)/8
s⁰: K
Conditions
Every entry of the first column must be positive.
K > 0
8·15 − K > 0 → K < 120
Answer
Kmax = 120
At K = 120 the closed loop oscillates at ω = √15 = 3.873 rad/s.
8.Stability: Routh–Hurwitz & root locus
Answer: si = −17.75
Root locus: as the gain K goes from 0 to ∞, the closed-loop poles, the roots of 1 + K·G(s) = 0, move from the open-loop poles to the open-loop zeros or to infinity. A point on the real axis belongs to the locus when the number of real poles and zeros to its right is odd. The n − m branches that go to infinity follow asymptotes at the angles (2q + 1)·180°/(n − m), which start from the centroid σₐ = (Σ poles − Σ zeros)/(n − m). Branches leave or join the real axis where dK/ds = 0. The angle condition ∠G(s) = 180° fixes the shape, and the magnitude condition K = 1/|G(s)| gives the gain at any point of the locus.
Gain along the real axis
K(s) = −(s² + 4s)/(s + 10)
Stationary points
Differentiate with the quotient rule and set the numerator to zero.
(2s + 4)(s + 10) − (s² + 4s) = s² + 20s + 40 = 0
s = −10 ± √60 = −2.254, −17.75
Break-in point
si = −17.75
Answer
si = −17.75
Between the two break points the locus is a circle centred on the zero, with radius √60 = 7.746.
9.Steady-state error & PID control
Answer: ess = 0.1
Steady-state error: in a unity-feedback loop with open-loop transfer function G(s) the error is E(s) = R(s)/(1 + G(s)), and by the final value theorem ess = lims→0 s·E(s). The system type is the number of poles of G(s) at s = 0. The error constants are Kp = lim G(s), Kv = lim s·G(s) and Ka = lim s²·G(s), all for s → 0. A step of size A gives ess = A/(1 + Kp), a ramp A·t gives A/Kv and a parabola A·t²/2 gives A/Ka. A type-0 loop follows a step with a finite error, a type-1 loop follows it exactly and a ramp with a finite error.
Velocity constant
Kv = lim s·G(s) = 10
Step part
Kp = ∞ → estep = 0
Ramp error
ess = 1/10 = 0.1
Answer
ess = 0.1
10.Steady-state error & PID control
Answer: ess = 0.5
P, PI and PID control: the controller C(s) = Kp + Ki/s + Kd·s acts on the error. A proportional gain makes the loop faster and reduces the error of a type-0 plant, but never removes it. The integral term adds a pole at s = 0: the system type rises by one, and a step is followed without error. The derivative term adds damping. To choose gains, write the closed-loop characteristic polynomial and compare it with s² + 2ζωns + ωn². Then %OS = 100·e−ζπ/√(1−ζ²), tp = π/ωd with ωd = ωn√(1 − ζ²), and ts ≈ 4/(ζωn).
Velocity constant
s·C(s) = 5s + 4 → 4 as s → 0.
Kv = 4·10/4 = 10
Ramp error
ess = 5/10 = 0.5
Answer
ess = 0.5
The PI controller removes the step error completely; a ramp is followed with a constant lag.
11.Bode plots & margins
Answer: BW = 318.3 Hz
Frequency response: substitute s = jω in the transfer function. The magnitude in decibels is 20·log₁₀|H(jω)| and the phase is the sum of the angles of the numerator factors minus those of the denominator factors. A first-order RC or RL filter has its corner (−3 dB) frequency at ωc = 1/(RC) or R/L, and fc = ωc/(2π); a low-pass filter gives |H| = 1/√(1 + (ω/ωc)²) and φ = −atan(ω/ωc). In the asymptotic (straight-line) Bode plot each pole bends the magnitude down by 20 dB/decade at its corner frequency, each zero bends it up by 20 dB/decade, and an integrator 1/s gives −20 dB/decade at all frequencies. Gain crossover ωc: |L(jω)| = 1 (0 dB); phase margin PM = 180° + ∠L(jωc). Phase crossover ω180: ∠L(jω) = −180°; gain margin GM = −20·log₁₀|L(jω180)| dB. The closed loop is stable when both margins are positive.
Resonant frequency
ω₀ = 1/√(LC) = 1/√(0.005·1 × 10⁻⁶) = 14142 rad/s
f₀ = ω₀/(2π) = 2251 Hz
Bandwidth
BW = R/L = 10/0.005 = 2000 rad/s = 318.3 Hz
Answer
BW = 318.3 Hz
12.Bode plots & margins
Answer: PM = 51.83 °
Frequency response: substitute s = jω in the transfer function. The magnitude in decibels is 20·log₁₀|H(jω)| and the phase is the sum of the angles of the numerator factors minus those of the denominator factors. A first-order RC or RL filter has its corner (−3 dB) frequency at ωc = 1/(RC) or R/L, and fc = ωc/(2π); a low-pass filter gives |H| = 1/√(1 + (ω/ωc)²) and φ = −atan(ω/ωc). In the asymptotic (straight-line) Bode plot each pole bends the magnitude down by 20 dB/decade at its corner frequency, each zero bends it up by 20 dB/decade, and an integrator 1/s gives −20 dB/decade at all frequencies. Gain crossover ωc: |L(jω)| = 1 (0 dB); phase margin PM = 180° + ∠L(jωc). Phase crossover ω180: ∠L(jω) = −180°; gain margin GM = −20·log₁₀|L(jω180)| dB. The closed loop is stable when both margins are positive.