In the print window, choose “Save as PDF” to keep a copy on your device.
1Formulas and methods
Stability: Routh–Hurwitz & root locus
Stability
all roots of the characteristic polynomial in the left half-plane
Routh array, s¹ entry of a cubic
b1 = (a2a1 − a3a0)/a2
Right half-plane roots
number of sign changes in the first column
Cubic s³ + a₂s² + a₁s + a₀
stable when all a > 0 and a₂·a₁ > a₀
K/(s(s + a)(s + b))
Kmax = ab(a + b), ω = √(ab)
Characteristic equation
1 + K·G(s) = 0
Asymptotes
σa = (Σp − Σz)/(n − m), θ = (2q + 1)·180°/(n − m)
Break-away and break-in points
dK/ds = 0
Magnitude condition
K = 1/|G(s)|
Angle of departure
θd = 180° − Σ∠(from other poles) + Σ∠(from zeros)
Method
Write the closed-loop characteristic polynomial: the denominator of 1 + K·G(s) = 0, multiplied out.
Put the coefficients alternately into the first two rows of the Routh array and build the remaining rows.
Count the sign changes in the first column: each one is a pole in the right half-plane. With K in the array, demand that every first-column entry stays positive.
For a root locus, mark the poles and zeros, the real-axis segments, the asymptotes from the centroid and the break points where dK/ds = 0. Use K = 1/|G(s)| for the gain at a point.
Steady-state error & PID control
System type
number of poles of G(s) at s = 0
Error constants
Kp = lim G(s), Kv = lim s·G(s), Ka = lim s²·G(s) (s → 0)
Step A
ess = A/(1 + Kp)
Ramp A·t
ess = A/Kv
Parabola A·t²/2
ess = A/Ka
PID controller
C(s) = Kp + Ki/s + Kd·s
Second-order target
s² + 2ζωns + ωn²
Overshoot and timing
%OS = 100·e−ζπ/√(1−ζ²), tp = π/ωd, ts ≈ 4/(ζωn)
Method
Count the poles of the open loop C(s)·G(s) at s = 0: that is the system type.
Work out the error constant that matches the input: Kp for a step, Kv for a ramp, Ka for a parabola.
Apply ess = A/(1 + Kp), A/Kv or A/Ka, or solve it for the gain you need.
For a damping or speed specification, write the closed-loop characteristic polynomial and match it with s² + 2ζω_n·s + ω_n².
2Practice problems
1.Laplace transformsMedium
Find f(t) for F(s) = 40/(s(s + 1)(s + 3)) by partial fractions, and evaluate f(1.5).
F(s) = 40/(s(s + 1)(s + 3))t = 1.5 s
f(1.5) =
2.Laplace transformsHard
Solve y″ + 9y′ + 20y = 0 with y(0) = −3 and y′(0) = 5 using the Laplace transform, and find y(0.2).
y″ + 9y′ + 20y = 0y(0) = −3y′(0) = 5t = 0.2 s
y(0.2) =
3.Block diagramsMedium
The plant G(s) = 5/(s + 7) has an inner (minor) negative feedback loop with gain H₁ = 1. A controller gain K = 11 and an outer unity negative feedback loop close the system. Find the closed-loop DC gain T(0).
G(s) = 5/(s + 7)H₁ = 1K = 11
T(0) =
4.Block diagramsHard
The plant G(s) = 38/(s(s + 3)) is in a negative feedback loop with sensor gain H = 0.5. The closed-loop poles are complex. Find their real part σ.
G(s) = 38/(s(s + 3))H = 0.5
σ =
5.Step responseMedium
A system has the transfer function G(s) = 225/(s² + 13s + 75) and receives a unit step input. Find the natural frequency ωn in rad/s.
G(s) = 225/(s² + 13s + 75)
ωn = rad/s
6.Step responseHard
A series RLC circuit with R = 179 Ω, L = 500 mH and C = 10 µF is connected to a 12 V step at t = 0. The capacitor is uncharged and no current flows before the step. Find the time tp of the first voltage peak, in ms.
R = 179 ΩL = 500 mHC = 10 µFV = 12 V
tp = ms
7.Stability: Routh–Hurwitz & root locusMedium
The loop in the diagram uses positive feedback, with L(s) = 5/(s(s + 4)(s + 5)). How many closed-loop poles N lie in the right half-plane?
L(s) = 5/(s(s + 4)(s + 5))
N =
8.Stability: Routh–Hurwitz & root locusHard
The root locus of L(s) = K(s + 6)/(s(s + 4)) leaves the real axis between s = 0 and s = −4, circles round and joins the real axis again to the left of the zero. Find the break-away point sb.
L(s) = K(s + 6)/(s(s + 4))
sb =
9.Steady-state error & PID controlMedium
The input r(t) = 1 + 4t (a step plus a ramp) is applied to a unity-feedback loop with G(s) = 2/(s(s + 10)). Find the steady-state error ess.
G(s) = 2/(s(s + 10))r(t) = 1 + 4t
ess =
10.Steady-state error & PID controlHard
A proportional controller K drives the plant G(s) = 4/(s(s + 10)) in a unity-feedback loop. Find the gain K that gives the closed loop a damping ratio ζ = 0.6.
G(s) = 4/(s(s + 10))ζ = 0.6
K =
11.Bode plots & marginsMedium
The RL high-pass filter shown has R = 47 Ω, L = 100 mH. A sinusoidal input of 150 Hz is applied. Find the phase shift φ of vout relative to vin, in degrees.
R = 47 ΩL = 100 mHf = 150 Hz
φ = °
12.Bode plots & marginsHard
A unity-feedback loop has the open-loop transfer function L(s) = 46/(s(s + 1)(s + 9)). Find the gain margin GM in dB.
L(s) = 46/(s(s + 1)(s + 9))
GM = dB
3Solutions
1.Laplace transforms
Answer: f(1.5) = 8.945
Laplace transform: F(s) = ∫₀∞ f(t)·e−st dt turns derivatives into multiplications by s: ℒ{f′} = sF(s) − f(0), ℒ{f″} = s²F(s) − s·f(0) − f′(0). Standard pairs: 1 ↔ 1/s, e−at ↔ 1/(s + a), t·e−at ↔ 1/(s + a)², sin ωt ↔ ω/(s² + ω²), cos ωt ↔ s/(s² + ω²), and a shift s → s + σ multiplies the time function by e−σt. To invert a rational F(s), split it into partial fractions: the residue of a simple pole p is A = [(s − p)·F(s)] at s = p. Final value theorem: f(∞) = lims→0 s·F(s), valid only when all poles of s·F(s) lie in the left half-plane. Initial value theorem: f(0⁺) = lims→∞ s·F(s).
Partial fractions
F(s) = A/s + B/(s + 1) + C/(s + 3)
A = 40/(1·3) = 13.33
B = 40/((−1)·2) = −20
C = 40/((−3)·(−2)) = 6.667
Inverse transform
f(t) = 13.33 − 20·e−t + 6.667·e−3t
Evaluate
f(1.5) = 13.33 − 20·e−1.5 + 6.667·e−3·1.5 = 8.945
Answer
f(1.5) = 8.945
2.Laplace transforms
Answer: y(0.2) = −1.918
Laplace transform: F(s) = ∫₀∞ f(t)·e−st dt turns derivatives into multiplications by s: ℒ{f′} = sF(s) − f(0), ℒ{f″} = s²F(s) − s·f(0) − f′(0). Standard pairs: 1 ↔ 1/s, e−at ↔ 1/(s + a), t·e−at ↔ 1/(s + a)², sin ωt ↔ ω/(s² + ω²), cos ωt ↔ s/(s² + ω²), and a shift s → s + σ multiplies the time function by e−σt. To invert a rational F(s), split it into partial fractions: the residue of a simple pole p is A = [(s − p)·F(s)] at s = p. Final value theorem: f(∞) = lims→0 s·F(s), valid only when all poles of s·F(s) lie in the left half-plane. Initial value theorem: f(0⁺) = lims→∞ s·F(s).
Transform the equation
s²Y − (−3)s − 5 + 9(sY − (−3)) + 20Y = 0
Y(s) = (−3s − 22)/((s + 4)(s + 5))
Partial fractions
A = −10/1 = −10
B = −7/(−1) = 7
Result
y(t) = −10·e−4t + 7·e−5t
y(0.2) = −1.918
Answer
y(0.2) = −1.918
Check: y(0) = A + B = −3.
3.Block diagrams
Answer: T(0) = 0.8209
Block-diagram algebra: blocks in series multiply (G₁·G₂), blocks in parallel add (G₁ + G₂), and a loop with forward path G and feedback path H reduces to T = G/(1 + G·H) for negative feedback and G/(1 − G·H) for positive feedback. Reduce inner loops first, then work outwards. The closed-loop poles are the roots of the characteristic equation 1 + G(s)H(s) = 0. For a stable loop, a step input of size A gives the steady-state output A·T(0); with unity feedback the steady-state error to a step is A/(1 + Kp) with Kp = G(0).
Block-diagram algebra: blocks in series multiply (G₁·G₂), blocks in parallel add (G₁ + G₂), and a loop with forward path G and feedback path H reduces to T = G/(1 + G·H) for negative feedback and G/(1 − G·H) for positive feedback. Reduce inner loops first, then work outwards. The closed-loop poles are the roots of the characteristic equation 1 + G(s)H(s) = 0. For a stable loop, a step input of size A gives the steady-state output A·T(0); with unity feedback the steady-state error to a step is A/(1 + Kp) with Kp = G(0).
Characteristic equation
s(s + 3) + 38·0.5 = 0 → s² + 3s + 19 = 0
Roots
s = −1.5 ± j·√(19 − 2.25) = −1.5 ± j4.093
σ = −1.5
Answer
σ = −1.5
5.Step response
Answer: ωn = 8.66 rad/s
Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).
Compare with the standard form
The denominator must match s² + 2ζωₙs + ωₙ².
ωₙ² = 75 → ωₙ = 8.66 rad/s
2ζωₙ = 13 → ζ = 13/(2·8.66) = 0.7506
Result
ωₙ = 8.66 rad/s
Answer
ωn = 8.66 rad/s
6.Step response
Answer: tp = 7.666 ms
Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).
Routh–Hurwitz criterion: a linear system is stable when every root of its characteristic polynomial lies in the left half of the s-plane. Write the coefficients alternately into the first two rows of the Routh array. Each entry of a new row comes from the two rows above it; for a cubic a₃s³ + a₂s² + a₁s + a₀ the s¹ entry is b₁ = (a₂·a₁ − a₃·a₀)/a₂. The number of sign changes in the first column equals the number of roots in the right half-plane. With a gain K in the coefficients, every first-column entry must stay positive: the gain that makes the s¹ entry zero is the stability limit, and the s² row then gives the frequency of the sustained oscillation.
Characteristic polynomial
s³ + 9s² + 20s − 5 = 0
Routh array
s³: 1, 20
s²: 9, −5
s¹: 20.56
s⁰: −5
Sign changes in the first column
1 → 9 → 20.56 → −5
N = 1
Answer
N = 1
Positive feedback makes the constant coefficient negative: one real pole always moves into the right half-plane.
8.Stability: Routh–Hurwitz & root locus
Answer: sb = −2.536
Root locus: as the gain K goes from 0 to ∞, the closed-loop poles, the roots of 1 + K·G(s) = 0, move from the open-loop poles to the open-loop zeros or to infinity. A point on the real axis belongs to the locus when the number of real poles and zeros to its right is odd. The n − m branches that go to infinity follow asymptotes at the angles (2q + 1)·180°/(n − m), which start from the centroid σₐ = (Σ poles − Σ zeros)/(n − m). Branches leave or join the real axis where dK/ds = 0. The angle condition ∠G(s) = 180° fixes the shape, and the magnitude condition K = 1/|G(s)| gives the gain at any point of the locus.
Gain along the real axis
K(s) = −(s² + 4s)/(s + 6)
Stationary points
Differentiate with the quotient rule and set the numerator to zero.
(2s + 4)(s + 6) − (s² + 4s) = s² + 12s + 24 = 0
s = −6 ± √12 = −2.536, −9.464
Break-away point
sb = −2.536
Answer
sb = −2.536
Between the two break points the locus is a circle centred on the zero, with radius √12 = 3.464.
9.Steady-state error & PID control
Answer: ess = 20
Steady-state error: in a unity-feedback loop with open-loop transfer function G(s) the error is E(s) = R(s)/(1 + G(s)), and by the final value theorem ess = lims→0 s·E(s). The system type is the number of poles of G(s) at s = 0. The error constants are Kp = lim G(s), Kv = lim s·G(s) and Ka = lim s²·G(s), all for s → 0. A step of size A gives ess = A/(1 + Kp), a ramp A·t gives A/Kv and a parabola A·t²/2 gives A/Ka. A type-0 loop follows a step with a finite error, a type-1 loop follows it exactly and a ramp with a finite error.
Velocity constant
Kv = lim s·G(s) = 0.2
Step part
Kp = ∞ → estep = 0
Ramp error
ess = 4/0.2 = 20
Answer
ess = 20
10.Steady-state error & PID control
Answer: K = 17.36
P, PI and PID control: the controller C(s) = Kp + Ki/s + Kd·s acts on the error. A proportional gain makes the loop faster and reduces the error of a type-0 plant, but never removes it. The integral term adds a pole at s = 0: the system type rises by one, and a step is followed without error. The derivative term adds damping. To choose gains, write the closed-loop characteristic polynomial and compare it with s² + 2ζωns + ωn². Then %OS = 100·e−ζπ/√(1−ζ²), tp = π/ωd with ωd = ωn√(1 − ζ²), and ts ≈ 4/(ζωn).
Characteristic polynomial
s(s + 10) + 4K = s² + 10s + 4K
Natural frequency
2·0.6·ωₙ = 10 → ωₙ = 8.333 rad/s
Gain
4K = ωₙ² = 69.44 → K = 17.36
Answer
K = 17.36
11.Bode plots & margins
Answer: φ = 26.5 °
Frequency response: substitute s = jω in the transfer function. The magnitude in decibels is 20·log₁₀|H(jω)| and the phase is the sum of the angles of the numerator factors minus those of the denominator factors. A first-order RC or RL filter has its corner (−3 dB) frequency at ωc = 1/(RC) or R/L, and fc = ωc/(2π); a low-pass filter gives |H| = 1/√(1 + (ω/ωc)²) and φ = −atan(ω/ωc). In the asymptotic (straight-line) Bode plot each pole bends the magnitude down by 20 dB/decade at its corner frequency, each zero bends it up by 20 dB/decade, and an integrator 1/s gives −20 dB/decade at all frequencies. Gain crossover ωc: |L(jω)| = 1 (0 dB); phase margin PM = 180° + ∠L(jωc). Phase crossover ω180: ∠L(jω) = −180°; gain margin GM = −20·log₁₀|L(jω180)| dB. The closed loop is stable when both margins are positive.
Corner frequency
ωc = R/L = 47/0.1 = 470 rad/s
fc = 74.8 Hz → f/fc = 150/74.8 = 2.005
Phase
φ = 90° − atan(2.005) = 26.5°
Answer
φ = 26.5°
12.Bode plots & margins
Answer: GM = 5.83 dB
Frequency response: substitute s = jω in the transfer function. The magnitude in decibels is 20·log₁₀|H(jω)| and the phase is the sum of the angles of the numerator factors minus those of the denominator factors. A first-order RC or RL filter has its corner (−3 dB) frequency at ωc = 1/(RC) or R/L, and fc = ωc/(2π); a low-pass filter gives |H| = 1/√(1 + (ω/ωc)²) and φ = −atan(ω/ωc). In the asymptotic (straight-line) Bode plot each pole bends the magnitude down by 20 dB/decade at its corner frequency, each zero bends it up by 20 dB/decade, and an integrator 1/s gives −20 dB/decade at all frequencies. Gain crossover ωc: |L(jω)| = 1 (0 dB); phase margin PM = 180° + ∠L(jωc). Phase crossover ω180: ∠L(jω) = −180°; gain margin GM = −20·log₁₀|L(jω180)| dB. The closed loop is stable when both margins are positive.