In the print window, choose “Save as PDF” to keep a copy on your device.
1Formulas and methods
Stability: Routh–Hurwitz & root locus
Stability
all roots of the characteristic polynomial in the left half-plane
Routh array, s¹ entry of a cubic
b1 = (a2a1 − a3a0)/a2
Right half-plane roots
number of sign changes in the first column
Cubic s³ + a₂s² + a₁s + a₀
stable when all a > 0 and a₂·a₁ > a₀
K/(s(s + a)(s + b))
Kmax = ab(a + b), ω = √(ab)
Characteristic equation
1 + K·G(s) = 0
Asymptotes
σa = (Σp − Σz)/(n − m), θ = (2q + 1)·180°/(n − m)
Break-away and break-in points
dK/ds = 0
Magnitude condition
K = 1/|G(s)|
Angle of departure
θd = 180° − Σ∠(from other poles) + Σ∠(from zeros)
Method
Write the closed-loop characteristic polynomial: the denominator of 1 + K·G(s) = 0, multiplied out.
Put the coefficients alternately into the first two rows of the Routh array and build the remaining rows.
Count the sign changes in the first column: each one is a pole in the right half-plane. With K in the array, demand that every first-column entry stays positive.
For a root locus, mark the poles and zeros, the real-axis segments, the asymptotes from the centroid and the break points where dK/ds = 0. Use K = 1/|G(s)| for the gain at a point.
Steady-state error & PID control
System type
number of poles of G(s) at s = 0
Error constants
Kp = lim G(s), Kv = lim s·G(s), Ka = lim s²·G(s) (s → 0)
Step A
ess = A/(1 + Kp)
Ramp A·t
ess = A/Kv
Parabola A·t²/2
ess = A/Ka
PID controller
C(s) = Kp + Ki/s + Kd·s
Second-order target
s² + 2ζωns + ωn²
Overshoot and timing
%OS = 100·e−ζπ/√(1−ζ²), tp = π/ωd, ts ≈ 4/(ζωn)
Method
Count the poles of the open loop C(s)·G(s) at s = 0: that is the system type.
Work out the error constant that matches the input: Kp for a step, Kv for a ramp, Ka for a parabola.
Apply ess = A/(1 + Kp), A/Kv or A/Ka, or solve it for the gain you need.
For a damping or speed specification, write the closed-loop characteristic polynomial and match it with s² + 2ζω_n·s + ω_n².
2Practice problems
1.Laplace transformsMedium
Find f(t) for F(s) = 4/(s² + 6s + 34) by completing the square, and evaluate f(0.2).
F(s) = 4/(s² + 6s + 34)t = 0.2 s
f(0.2) =
2.Laplace transformsHard
A system is described by the differential equation y″ + 11y′ + 30y = 3u′ + 20u, with input u(t) and output y(t). Find its transfer function G(s) = Y(s)/U(s) (zero initial conditions) and evaluate the impulse response g(t) at t = 0.3 s. Find g(0.3).
y″ + 11y′ + 30y = 3u′ + 20ut = 0.3 s
g(0.3) =
3.Block diagramsMedium
A plant G(s) = 35/(s + 8) is controlled in a negative feedback loop whose sensor has the gain H = 0.2. A step of size 12 is applied at R. Find the steady-state output css.
G(s) = 35/(s + 8)H = 0.2R = 12
css =
4.Block diagramsHard
A proportional controller K drives the plant G(s) = 10/(s + 4) in a unity negative feedback loop. A disturbance step of size 2 enters at the plant input while R = 0. Find the smallest gain K that keeps the steady-state output at or below 0.5.
G(s) = 10/(s + 4)D = 2css ≤ 0.5
K =
5.Step responseMedium
A system has the transfer function G(s) = 14/(s² + 6s + 14) and receives a unit step input. Find the 2 % settling time ts of the step response, using ts ≈ 4/(ζωₙ).
G(s) = 14/(s² + 6s + 14)
ts = s
6.Step responseHard
A mass m = 4 kg hangs on a spring k = 5000 N/m with a viscous damper c = 85 N·s/m (m·x″ + c·x′ + k·x = F). At rest in equilibrium, a constant force F = 20 N is suddenly applied. Find the largest displacement xmax in mm.
m = 4 kgk = 5000 N/mc = 85 N·s/mF = 20 N
xmax = mm
7.Stability: Routh–Hurwitz & root locusMedium
A unity-feedback loop has L(s) = K(s + 13)/(s(s + 3)(s + 4)), with K > 0. Find the largest gain Kmax for which the closed loop is stable.
L(s) = K(s + 13)/(s(s + 3)(s + 4))
Kmax =
8.Stability: Routh–Hurwitz & root locusHard
The root locus of L(s) = K(s + 6)/(s(s + 5)) leaves the real axis between s = 0 and s = −5, circles round and joins the real axis again to the left of the zero. Find the break-away point sb.
L(s) = K(s + 6)/(s(s + 5))
sb =
9.Steady-state error & PID controlMedium
A unity-feedback loop has G(s) = K/((s + 1)(s + 5)). Find the gain K that gives a steady-state error of 20 % for a step input.
G(s) = K/((s + 1)(s + 5))ess = 20 %
K =
10.Steady-state error & PID controlHard
A PI controller C(s) = Kp + Ki/s drives the plant G(s) = 1/(s + 1) in a unity-feedback loop. The closed loop must have ωₙ = 5 rad/s and ζ = 0.6. Find the integral gain Ki.
G(s) = 1/(s + 1)ωₙ = 5 rad/sζ = 0.6
Ki =
11.Bode plots & marginsMedium
Find the exact magnitude |G(jω)| of G(s) = 2106/((s + 9)(s + 18)) at ω = 5 rad/s, in dB.
G(s) = 2106/((s + 9)(s + 18))ω = 5 rad/s
|G(jω)| = dB
12.Bode plots & marginsHard
A unity-feedback loop has the open-loop transfer function L(s) = 1144/(s(s + 8)(s + 10)). Find the phase crossover frequency ω180, where ∠L(jω) = −180°.
L(s) = 1144/(s(s + 8)(s + 10))
ω180 = rad/s
3Solutions
1.Laplace transforms
Answer: f(0.2) = 0.3694
Laplace transform: F(s) = ∫₀∞ f(t)·e−st dt turns derivatives into multiplications by s: ℒ{f′} = sF(s) − f(0), ℒ{f″} = s²F(s) − s·f(0) − f′(0). Standard pairs: 1 ↔ 1/s, e−at ↔ 1/(s + a), t·e−at ↔ 1/(s + a)², sin ωt ↔ ω/(s² + ω²), cos ωt ↔ s/(s² + ω²), and a shift s → s + σ multiplies the time function by e−σt. To invert a rational F(s), split it into partial fractions: the residue of a simple pole p is A = [(s − p)·F(s)] at s = p. Final value theorem: f(∞) = lims→0 s·F(s), valid only when all poles of s·F(s) lie in the left half-plane. Initial value theorem: f(0⁺) = lims→∞ s·F(s).
Complete the square
s² + 6s + 34 = (s + 3)² + 25 = (s + 3)² + 5²
Match the numerator
F(s) = (4/5)·5/((s + 3)² + 5²)
Inverse transform
f(t) = e−3t·(0.8·sin 5t)
f(0.2) = e−3·0.2·(0.8·sin(5·0.2)) = 0.3694
Answer
f(0.2) = 0.3694
2.Laplace transforms
Answer: g(0.3) = 0.7851
Laplace transform: F(s) = ∫₀∞ f(t)·e−st dt turns derivatives into multiplications by s: ℒ{f′} = sF(s) − f(0), ℒ{f″} = s²F(s) − s·f(0) − f′(0). Standard pairs: 1 ↔ 1/s, e−at ↔ 1/(s + a), t·e−at ↔ 1/(s + a)², sin ωt ↔ ω/(s² + ω²), cos ωt ↔ s/(s² + ω²), and a shift s → s + σ multiplies the time function by e−σt. To invert a rational F(s), split it into partial fractions: the residue of a simple pole p is A = [(s − p)·F(s)] at s = p. Final value theorem: f(∞) = lims→0 s·F(s), valid only when all poles of s·F(s) lie in the left half-plane. Initial value theorem: f(0⁺) = lims→∞ s·F(s).
Transfer function
G(s) = Y(s)/U(s) = (3s + 20)/(s² + 11s + 30)
Partial fractions
s² + 11s + 30 = (s + 5)(s + 6)
A = 5, B = −2
Impulse response
g(t) = 5·e−5t − 2·e−6t
g(0.3) = 0.7851
Answer
g(0.3) = 0.7851
3.Block diagrams
Answer: css = 28
Block-diagram algebra: blocks in series multiply (G₁·G₂), blocks in parallel add (G₁ + G₂), and a loop with forward path G and feedback path H reduces to T = G/(1 + G·H) for negative feedback and G/(1 − G·H) for positive feedback. Reduce inner loops first, then work outwards. The closed-loop poles are the roots of the characteristic equation 1 + G(s)H(s) = 0. For a stable loop, a step input of size A gives the steady-state output A·T(0); with unity feedback the steady-state error to a step is A/(1 + Kp) with Kp = G(0).
Closed-loop transfer function
T(s) = G/(1 + G·H) = 35/(s + 8 + 7) = 35/(s + 15)
Result
css = R·T(0) = 12·35/15 = 28
Answer
css = 28
4.Block diagrams
Answer: K = 3.6
Block-diagram algebra: blocks in series multiply (G₁·G₂), blocks in parallel add (G₁ + G₂), and a loop with forward path G and feedback path H reduces to T = G/(1 + G·H) for negative feedback and G/(1 − G·H) for positive feedback. Reduce inner loops first, then work outwards. The closed-loop poles are the roots of the characteristic equation 1 + G(s)H(s) = 0. For a stable loop, a step input of size A gives the steady-state output A·T(0); with unity feedback the steady-state error to a step is A/(1 + Kp) with Kp = G(0).
Disturbance response
css = D·G(0)/(1 + K·G(0)) = 2·10/(4 + 10K)
Solve for K
4 + 10K = 2·10/0.5 = 40
K = (40 − 4)/10 = 3.6
Answer
K = 3.6
5.Step response
Answer: ts = 1.333 s
Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).
Compare with the standard form
The denominator must match s² + 2ζωₙs + ωₙ².
ωₙ² = 14 → ωₙ = 3.742 rad/s
2ζωₙ = 6 → ζ = 6/(2·3.742) = 0.8018
Result
ζωₙ = 3 → ts ≈ 4/3 = 1.333 s
Answer
ts = 1.333 s
6.Step response
Answer: xmax = 5.487 mm
Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).
Natural frequency and damping ratio
ωₙ = √(k/m) = √(5000/4) = 35.36 rad/s
ζ = c/(2√(km)) = 85/(2·√(5000·4)) = 0.3005
Result
xst = F/k = 20/5000 m = 4 mm
%OS = 37.16 %
xmax = 4·(1 + 0.3716) = 5.487 mm
Answer
xmax = 5.487 mm
7.Stability: Routh–Hurwitz & root locus
Answer: Kmax = 14
Routh–Hurwitz criterion: a linear system is stable when every root of its characteristic polynomial lies in the left half of the s-plane. Write the coefficients alternately into the first two rows of the Routh array. Each entry of a new row comes from the two rows above it; for a cubic a₃s³ + a₂s² + a₁s + a₀ the s¹ entry is b₁ = (a₂·a₁ − a₃·a₀)/a₂. The number of sign changes in the first column equals the number of roots in the right half-plane. With a gain K in the coefficients, every first-column entry must stay positive: the gain that makes the s¹ entry zero is the stability limit, and the s² row then gives the frequency of the sustained oscillation.
With the zero to the right of s = −7 the loop would stay stable for every K > 0.
8.Stability: Routh–Hurwitz & root locus
Answer: sb = −3.551
Root locus: as the gain K goes from 0 to ∞, the closed-loop poles, the roots of 1 + K·G(s) = 0, move from the open-loop poles to the open-loop zeros or to infinity. A point on the real axis belongs to the locus when the number of real poles and zeros to its right is odd. The n − m branches that go to infinity follow asymptotes at the angles (2q + 1)·180°/(n − m), which start from the centroid σₐ = (Σ poles − Σ zeros)/(n − m). Branches leave or join the real axis where dK/ds = 0. The angle condition ∠G(s) = 180° fixes the shape, and the magnitude condition K = 1/|G(s)| gives the gain at any point of the locus.
Gain along the real axis
K(s) = −(s² + 5s)/(s + 6)
Stationary points
Differentiate with the quotient rule and set the numerator to zero.
(2s + 5)(s + 6) − (s² + 5s) = s² + 12s + 30 = 0
s = −6 ± √6 = −3.551, −8.449
Break-away point
sb = −3.551
Answer
sb = −3.551
Between the two break points the locus is a circle centred on the zero, with radius √6 = 2.449.
9.Steady-state error & PID control
Answer: K = 20
Steady-state error: in a unity-feedback loop with open-loop transfer function G(s) the error is E(s) = R(s)/(1 + G(s)), and by the final value theorem ess = lims→0 s·E(s). The system type is the number of poles of G(s) at s = 0. The error constants are Kp = lim G(s), Kv = lim s·G(s) and Ka = lim s²·G(s), all for s → 0. A step of size A gives ess = A/(1 + Kp), a ramp A·t gives A/Kv and a parabola A·t²/2 gives A/Ka. A type-0 loop follows a step with a finite error, a type-1 loop follows it exactly and a ramp with a finite error.
Required error constant
1/(1 + Kp) = 0.2 → Kp = 4
Gain
K/5 = 4 → K = 20
Answer
K = 20
Check the closed-loop stability as well: for this second-order loop any K > 0 is stable.
10.Steady-state error & PID control
Answer: Ki = 25
P, PI and PID control: the controller C(s) = Kp + Ki/s + Kd·s acts on the error. A proportional gain makes the loop faster and reduces the error of a type-0 plant, but never removes it. The integral term adds a pole at s = 0: the system type rises by one, and a step is followed without error. The derivative term adds damping. To choose gains, write the closed-loop characteristic polynomial and compare it with s² + 2ζωns + ωn². Then %OS = 100·e−ζπ/√(1−ζ²), tp = π/ωd with ωd = ωn√(1 − ζ²), and ts ≈ 4/(ζωn).
Characteristic polynomial
1 + C(s)G(s) = 0, multiplied by s(s + 1).
s² + (1 + 1Kp)s + 1Ki
Target polynomial
s² + 2·0.6·5s + 5² = s² + 6s + 25
Match the coefficients
1Ki = 25 → Ki = 25
Answer
Ki = 25
The integral term makes the loop type 1, so a step is followed without steady-state error.
11.Bode plots & margins
Answer: |G(jω)| = 20.79 dB
Frequency response: substitute s = jω in the transfer function. The magnitude in decibels is 20·log₁₀|H(jω)| and the phase is the sum of the angles of the numerator factors minus those of the denominator factors. A first-order RC or RL filter has its corner (−3 dB) frequency at ωc = 1/(RC) or R/L, and fc = ωc/(2π); a low-pass filter gives |H| = 1/√(1 + (ω/ωc)²) and φ = −atan(ω/ωc). In the asymptotic (straight-line) Bode plot each pole bends the magnitude down by 20 dB/decade at its corner frequency, each zero bends it up by 20 dB/decade, and an integrator 1/s gives −20 dB/decade at all frequencies. Gain crossover ωc: |L(jω)| = 1 (0 dB); phase margin PM = 180° + ∠L(jωc). Phase crossover ω180: ∠L(jω) = −180°; gain margin GM = −20·log₁₀|L(jω180)| dB. The closed loop is stable when both margins are positive.
Frequency response: substitute s = jω in the transfer function. The magnitude in decibels is 20·log₁₀|H(jω)| and the phase is the sum of the angles of the numerator factors minus those of the denominator factors. A first-order RC or RL filter has its corner (−3 dB) frequency at ωc = 1/(RC) or R/L, and fc = ωc/(2π); a low-pass filter gives |H| = 1/√(1 + (ω/ωc)²) and φ = −atan(ω/ωc). In the asymptotic (straight-line) Bode plot each pole bends the magnitude down by 20 dB/decade at its corner frequency, each zero bends it up by 20 dB/decade, and an integrator 1/s gives −20 dB/decade at all frequencies. Gain crossover ωc: |L(jω)| = 1 (0 dB); phase margin PM = 180° + ∠L(jωc). Phase crossover ω180: ∠L(jω) = −180°; gain margin GM = −20·log₁₀|L(jω180)| dB. The closed loop is stable when both margins are positive.