In the print window, choose “Save as PDF” to keep a copy on your device.
1Formulas and methods
Stability: Routh–Hurwitz & root locus
Stability
all roots of the characteristic polynomial in the left half-plane
Routh array, s¹ entry of a cubic
b1 = (a2a1 − a3a0)/a2
Right half-plane roots
number of sign changes in the first column
Cubic s³ + a₂s² + a₁s + a₀
stable when all a > 0 and a₂·a₁ > a₀
K/(s(s + a)(s + b))
Kmax = ab(a + b), ω = √(ab)
Characteristic equation
1 + K·G(s) = 0
Asymptotes
σa = (Σp − Σz)/(n − m), θ = (2q + 1)·180°/(n − m)
Break-away and break-in points
dK/ds = 0
Magnitude condition
K = 1/|G(s)|
Angle of departure
θd = 180° − Σ∠(from other poles) + Σ∠(from zeros)
Method
Write the closed-loop characteristic polynomial: the denominator of 1 + K·G(s) = 0, multiplied out.
Put the coefficients alternately into the first two rows of the Routh array and build the remaining rows.
Count the sign changes in the first column: each one is a pole in the right half-plane. With K in the array, demand that every first-column entry stays positive.
For a root locus, mark the poles and zeros, the real-axis segments, the asymptotes from the centroid and the break points where dK/ds = 0. Use K = 1/|G(s)| for the gain at a point.
Steady-state error & PID control
System type
number of poles of G(s) at s = 0
Error constants
Kp = lim G(s), Kv = lim s·G(s), Ka = lim s²·G(s) (s → 0)
Step A
ess = A/(1 + Kp)
Ramp A·t
ess = A/Kv
Parabola A·t²/2
ess = A/Ka
PID controller
C(s) = Kp + Ki/s + Kd·s
Second-order target
s² + 2ζωns + ωn²
Overshoot and timing
%OS = 100·e−ζπ/√(1−ζ²), tp = π/ωd, ts ≈ 4/(ζωn)
Method
Count the poles of the open loop C(s)·G(s) at s = 0: that is the system type.
Work out the error constant that matches the input: Kp for a step, Kv for a ramp, Ka for a parabola.
Apply ess = A/(1 + Kp), A/Kv or A/Ka, or solve it for the gain you need.
For a damping or speed specification, write the closed-loop characteristic polynomial and match it with s² + 2ζω_n·s + ω_n².
2Practice problems
1.Laplace transformsMedium
Find f(t) for F(s) = (3s + 10)/(s² + 10s + 25) and evaluate f(0.3).
F(s) = (3s + 10)/(s² + 10s + 25)t = 0.3 s
f(0.3) =
2.Laplace transformsHard
A system obeys y″ + 5y′ + 6y = 24·u(t). It starts at rest (y(0) = 0, y′(0) = 0) and the input is a step u(t) = 10 for t ≥ 0. Use the Laplace transform to find the output y(0.5).
A unity negative feedback loop has G(s) = 5(s + 7)/((s + 4)(s + 9)). A step of size 5 is applied at the reference. Find the steady-state error ess.
G(s) = 5(s + 7)/((s + 4)(s + 9))R = 5
ess =
4.Block diagramsHard
A proportional controller K drives the plant G(s) = 2/(s + 2) in a unity negative feedback loop. A disturbance step of size 2 enters at the plant input while R = 0. Find the smallest gain K that keeps the steady-state output at or below 0.2.
G(s) = 2/(s + 2)D = 2css ≤ 0.2
K =
5.Step responseMedium
A system has the transfer function G(s) = 41/(s² + 6s + 41) and receives a unit step input. Find the 2 % settling time ts of the step response, using ts ≈ 4/(ζωₙ).
G(s) = 41/(s² + 6s + 41)
ts = s
6.Step responseHard
A series RLC circuit with R = 39 Ω, L = 20 mH and C = 4.7 µF is connected to a 24 V step at t = 0. The capacitor is uncharged and no current flows before the step. Find the percent overshoot %OS of the capacitor voltage.
R = 39 ΩL = 20 mHC = 4.7 µFV = 24 V
%OS = %
7.Stability: Routh–Hurwitz & root locusMedium
The loop in the diagram runs with K = 76.8 and L(s) = K/(s(s + 4)(s + 8)). By what factor m can the gain be raised before the closed loop becomes unstable?
L(s) = K/(s(s + 4)(s + 8))K = 76.8
m =
8.Stability: Routh–Hurwitz & root locusHard
The root locus of L(s) = K/(s(s + 8)) is shown. Find the gain K for which the closed-loop poles have the damping ratio ζ = 0.707.
L(s) = K/(s(s + 8))ζ = 0.707
K =
9.Steady-state error & PID controlMedium
A unity-feedback loop has G(s) = K/((s + 4)(s + 10)). Find the gain K that gives a steady-state error of 2 % for a step input.
G(s) = K/((s + 4)(s + 10))ess = 2 %
K =
10.Steady-state error & PID controlHard
A proportional controller K = 5 drives the plant G(s) = 10/(s(s + 4)) in a unity-feedback loop. Find the percent overshoot %OS of the step response.
G(s) = 10/(s(s + 4))K = 5
%OS = %
11.Bode plots & marginsMedium
The RL low-pass filter shown has R = 47 Ω, L = 4.7 mH. A sinusoidal input of 800 Hz is applied. Find the phase shift φ of vout relative to vin, in degrees.
R = 47 ΩL = 4.7 mHf = 800 Hz
φ = °
12.Bode plots & marginsHard
A unity-feedback loop has the open-loop transfer function L(s) = K/(s(s + 3)(s + 6)). Find the gain K that gives a gain margin of 8 dB.
L(s) = K/(s(s + 3)(s + 6))GM = 8 dB
K =
3Solutions
1.Laplace transforms
Answer: f(0.3) = 0.3347
Laplace transform: F(s) = ∫₀∞ f(t)·e−st dt turns derivatives into multiplications by s: ℒ{f′} = sF(s) − f(0), ℒ{f″} = s²F(s) − s·f(0) − f′(0). Standard pairs: 1 ↔ 1/s, e−at ↔ 1/(s + a), t·e−at ↔ 1/(s + a)², sin ωt ↔ ω/(s² + ω²), cos ωt ↔ s/(s² + ω²), and a shift s → s + σ multiplies the time function by e−σt. To invert a rational F(s), split it into partial fractions: the residue of a simple pole p is A = [(s − p)·F(s)] at s = p. Final value theorem: f(∞) = lims→0 s·F(s), valid only when all poles of s·F(s) lie in the left half-plane. Initial value theorem: f(0⁺) = lims→∞ s·F(s).
Factor the denominator
s² + 10s + 25 = (s + 5)²
Partial fractions
3s + 10 = 3(s + 5) + −5
F(s) = 3/(s + 5) − 5/(s + 5)²
Inverse transform
f(t) = 3·e−5t − 5·t·e−5t
f(0.3) = (3 − 5·0.3)·e−5·0.3 = 0.3347
Answer
f(0.3) = 0.3347
2.Laplace transforms
Answer: y(0.5) = 13.7
Laplace transform: F(s) = ∫₀∞ f(t)·e−st dt turns derivatives into multiplications by s: ℒ{f′} = sF(s) − f(0), ℒ{f″} = s²F(s) − s·f(0) − f′(0). Standard pairs: 1 ↔ 1/s, e−at ↔ 1/(s + a), t·e−at ↔ 1/(s + a)², sin ωt ↔ ω/(s² + ω²), cos ωt ↔ s/(s² + ω²), and a shift s → s + σ multiplies the time function by e−σt. To invert a rational F(s), split it into partial fractions: the residue of a simple pole p is A = [(s − p)·F(s)] at s = p. Final value theorem: f(∞) = lims→0 s·F(s), valid only when all poles of s·F(s) lie in the left half-plane. Initial value theorem: f(0⁺) = lims→∞ s·F(s).
Transform the equation
Y(s) = 240/(s(s + 2)(s + 3))
Partial fractions
A = 240/(2·3) = 40
B = 240/((−2)·1) = −120
C = 240/((−3)·(−1)) = 80
Output
y(t) = 40 − 120·e−2t + 80·e−3t
y(0.5) = 13.7
Answer
y(0.5) = 13.7
3.Block diagrams
Answer: ess = 2.535
Block-diagram algebra: blocks in series multiply (G₁·G₂), blocks in parallel add (G₁ + G₂), and a loop with forward path G and feedback path H reduces to T = G/(1 + G·H) for negative feedback and G/(1 − G·H) for positive feedback. Reduce inner loops first, then work outwards. The closed-loop poles are the roots of the characteristic equation 1 + G(s)H(s) = 0. For a stable loop, a step input of size A gives the steady-state output A·T(0); with unity feedback the steady-state error to a step is A/(1 + Kp) with Kp = G(0).
Position error constant
Kₚ = G(0) = 5·7/(4·9) = 0.9722
Steady-state error
ess = A/(1 + Kₚ) = 5/(1 + 0.9722) = 2.535
Answer
ess = 2.535
4.Block diagrams
Answer: K = 9
Block-diagram algebra: blocks in series multiply (G₁·G₂), blocks in parallel add (G₁ + G₂), and a loop with forward path G and feedback path H reduces to T = G/(1 + G·H) for negative feedback and G/(1 − G·H) for positive feedback. Reduce inner loops first, then work outwards. The closed-loop poles are the roots of the characteristic equation 1 + G(s)H(s) = 0. For a stable loop, a step input of size A gives the steady-state output A·T(0); with unity feedback the steady-state error to a step is A/(1 + Kp) with Kp = G(0).
Disturbance response
css = D·G(0)/(1 + K·G(0)) = 2·2/(2 + 2K)
Solve for K
2 + 2K = 2·2/0.2 = 20
K = (20 − 2)/2 = 9
Answer
K = 9
5.Step response
Answer: ts = 1.333 s
Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).
Compare with the standard form
The denominator must match s² + 2ζωₙs + ωₙ².
ωₙ² = 41 → ωₙ = 6.403 rad/s
2ζωₙ = 6 → ζ = 6/(2·6.403) = 0.4685
Result
ζωₙ = 3 → ts ≈ 4/3 = 1.333 s
Answer
ts = 1.333 s
6.Step response
Answer: %OS = 37.38 %
Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).
Routh–Hurwitz criterion: a linear system is stable when every root of its characteristic polynomial lies in the left half of the s-plane. Write the coefficients alternately into the first two rows of the Routh array. Each entry of a new row comes from the two rows above it; for a cubic a₃s³ + a₂s² + a₁s + a₀ the s¹ entry is b₁ = (a₂·a₁ − a₃·a₀)/a₂. The number of sign changes in the first column equals the number of roots in the right half-plane. With a gain K in the coefficients, every first-column entry must stay positive: the gain that makes the s¹ entry zero is the stability limit, and the s² row then gives the frequency of the sustained oscillation.
Routh array
s³ + 12s² + 32s + K = 0
s³: 1, 32
s²: 12, K
s¹: (12·32 − K)/12
s⁰: K
Largest stable gain
Kmax = 12·32 = 384
Factor
m = 384/76.8 = 5
Answer
m = 5
This factor is the gain margin as a ratio: 13.98 dB.
8.Stability: Routh–Hurwitz & root locus
Answer: K = 32.01
Root locus: as the gain K goes from 0 to ∞, the closed-loop poles, the roots of 1 + K·G(s) = 0, move from the open-loop poles to the open-loop zeros or to infinity. A point on the real axis belongs to the locus when the number of real poles and zeros to its right is odd. The n − m branches that go to infinity follow asymptotes at the angles (2q + 1)·180°/(n − m), which start from the centroid σₐ = (Σ poles − Σ zeros)/(n − m). Branches leave or join the real axis where dK/ds = 0. The angle condition ∠G(s) = 180° fixes the shape, and the magnitude condition K = 1/|G(s)| gives the gain at any point of the locus.
Compare with the standard form
s² + 8s + K = s² + 2ζωₙs + ωₙ²
2·0.707·ωₙ = 8 → ωₙ = 5.658 rad/s
Gain
K = ωₙ² = 5.658² = 32.01
Answer
K = 32.01
The closed-loop poles sit where the ζ line crosses the vertical branch at s = −4.
9.Steady-state error & PID control
Answer: K = 1960
Steady-state error: in a unity-feedback loop with open-loop transfer function G(s) the error is E(s) = R(s)/(1 + G(s)), and by the final value theorem ess = lims→0 s·E(s). The system type is the number of poles of G(s) at s = 0. The error constants are Kp = lim G(s), Kv = lim s·G(s) and Ka = lim s²·G(s), all for s → 0. A step of size A gives ess = A/(1 + Kp), a ramp A·t gives A/Kv and a parabola A·t²/2 gives A/Ka. A type-0 loop follows a step with a finite error, a type-1 loop follows it exactly and a ramp with a finite error.
Required error constant
1/(1 + Kp) = 0.02 → Kp = 49
Gain
K/40 = 49 → K = 1960
Answer
K = 1960
Check the closed-loop stability as well: for this second-order loop any K > 0 is stable.
10.Steady-state error & PID control
Answer: %OS = 39.6 %
P, PI and PID control: the controller C(s) = Kp + Ki/s + Kd·s acts on the error. A proportional gain makes the loop faster and reduces the error of a type-0 plant, but never removes it. The integral term adds a pole at s = 0: the system type rises by one, and a step is followed without error. The derivative term adds damping. To choose gains, write the closed-loop characteristic polynomial and compare it with s² + 2ζωns + ωn². Then %OS = 100·e−ζπ/√(1−ζ²), tp = π/ωd with ωd = ωn√(1 − ζ²), and ts ≈ 4/(ζωn).
Characteristic polynomial
s(s + 4) + 5·10 = s² + 4s + 50
ωₙ and ζ
ωₙ = √50 = 7.071 rad/s
ζ = 4/(2·7.071) = 0.2828
Overshoot
%OS = 100·e−0.2828π/√(1 − 0.2828²) = 39.6 %
Answer
%OS = 39.6 %
11.Bode plots & margins
Answer: φ = −26.69 °
Frequency response: substitute s = jω in the transfer function. The magnitude in decibels is 20·log₁₀|H(jω)| and the phase is the sum of the angles of the numerator factors minus those of the denominator factors. A first-order RC or RL filter has its corner (−3 dB) frequency at ωc = 1/(RC) or R/L, and fc = ωc/(2π); a low-pass filter gives |H| = 1/√(1 + (ω/ωc)²) and φ = −atan(ω/ωc). In the asymptotic (straight-line) Bode plot each pole bends the magnitude down by 20 dB/decade at its corner frequency, each zero bends it up by 20 dB/decade, and an integrator 1/s gives −20 dB/decade at all frequencies. Gain crossover ωc: |L(jω)| = 1 (0 dB); phase margin PM = 180° + ∠L(jωc). Phase crossover ω180: ∠L(jω) = −180°; gain margin GM = −20·log₁₀|L(jω180)| dB. The closed loop is stable when both margins are positive.
Corner frequency
ωc = R/L = 47/0.0047 = 10000 rad/s
fc = 1592 Hz → f/fc = 800/1592 = 0.5027
Phase
φ = − atan(0.5027) = −26.69°
Answer
φ = −26.69°
12.Bode plots & margins
Answer: K = 64.49
Frequency response: substitute s = jω in the transfer function. The magnitude in decibels is 20·log₁₀|H(jω)| and the phase is the sum of the angles of the numerator factors minus those of the denominator factors. A first-order RC or RL filter has its corner (−3 dB) frequency at ωc = 1/(RC) or R/L, and fc = ωc/(2π); a low-pass filter gives |H| = 1/√(1 + (ω/ωc)²) and φ = −atan(ω/ωc). In the asymptotic (straight-line) Bode plot each pole bends the magnitude down by 20 dB/decade at its corner frequency, each zero bends it up by 20 dB/decade, and an integrator 1/s gives −20 dB/decade at all frequencies. Gain crossover ωc: |L(jω)| = 1 (0 dB); phase margin PM = 180° + ∠L(jωc). Phase crossover ω180: ∠L(jω) = −180°; gain margin GM = −20·log₁₀|L(jω180)| dB. The closed loop is stable when both margins are positive.