In the print window, choose “Save as PDF” to keep a copy on your device.
1Formulas and methods
Stability: Routh–Hurwitz & root locus
Stability
all roots of the characteristic polynomial in the left half-plane
Routh array, s¹ entry of a cubic
b1 = (a2a1 − a3a0)/a2
Right half-plane roots
number of sign changes in the first column
Cubic s³ + a₂s² + a₁s + a₀
stable when all a > 0 and a₂·a₁ > a₀
K/(s(s + a)(s + b))
Kmax = ab(a + b), ω = √(ab)
Characteristic equation
1 + K·G(s) = 0
Asymptotes
σa = (Σp − Σz)/(n − m), θ = (2q + 1)·180°/(n − m)
Break-away and break-in points
dK/ds = 0
Magnitude condition
K = 1/|G(s)|
Angle of departure
θd = 180° − Σ∠(from other poles) + Σ∠(from zeros)
Method
Write the closed-loop characteristic polynomial: the denominator of 1 + K·G(s) = 0, multiplied out.
Put the coefficients alternately into the first two rows of the Routh array and build the remaining rows.
Count the sign changes in the first column: each one is a pole in the right half-plane. With K in the array, demand that every first-column entry stays positive.
For a root locus, mark the poles and zeros, the real-axis segments, the asymptotes from the centroid and the break points where dK/ds = 0. Use K = 1/|G(s)| for the gain at a point.
Steady-state error & PID control
System type
number of poles of G(s) at s = 0
Error constants
Kp = lim G(s), Kv = lim s·G(s), Ka = lim s²·G(s) (s → 0)
Step A
ess = A/(1 + Kp)
Ramp A·t
ess = A/Kv
Parabola A·t²/2
ess = A/Ka
PID controller
C(s) = Kp + Ki/s + Kd·s
Second-order target
s² + 2ζωns + ωn²
Overshoot and timing
%OS = 100·e−ζπ/√(1−ζ²), tp = π/ωd, ts ≈ 4/(ζωn)
Method
Count the poles of the open loop C(s)·G(s) at s = 0: that is the system type.
Work out the error constant that matches the input: Kp for a step, Kv for a ramp, Ka for a parabola.
Apply ess = A/(1 + Kp), A/Kv or A/Ka, or solve it for the gain you need.
For a damping or speed specification, write the closed-loop characteristic polynomial and match it with s² + 2ζω_n·s + ω_n².
2Practice problems
1.Laplace transformsMedium
F(s) = (6s + 37)/(s² + 12s + 32). Its inverse transform has the form f(t) = A·e−4t + B·e−8t. Find the coefficient A by partial fractions.
F(s) = (6s + 37)/(s² + 12s + 32)
A =
2.Laplace transformsHard
A system obeys y″ + 8y′ + 12y = 12·u(t), with y(0) = 1 and y′(0) = 0. At t = 0 a step input u(t) = 10 is applied. Use the Laplace transform to find y(0.4).
A plant G(s) = 12/(s + 5) is controlled in a negative feedback loop whose sensor has the gain H = 0.2. A step of size 24 is applied at R. Find the steady-state output css.
G(s) = 12/(s + 5)H = 0.2R = 24
css =
4.Block diagramsHard
A proportional controller K = 27 drives the plant G(s) = 5/(s + 7) in a unity negative feedback loop. A disturbance D enters at the plant input (it is added to the controller output). A reference step of size 2 and a disturbance step of size 0.5 are applied together. Find the steady-state output css.
K = 27G(s) = 5/(s + 7)D = 0.5R = 2
css =
5.Step responseMedium
A system has the transfer function G(s) = 31/(s² + 3s + 31) and receives a unit step input. Find the peak time tp of the step response.
G(s) = 31/(s² + 3s + 31)
tp = s
6.Step responseHard
A unity negative feedback loop has G(s) = 115/(s(s + 5)). Find the 2 % settling time ts of the closed-loop step response, using ts ≈ 4/(ζωₙ).
G(s) = 115/(s(s + 5))
ts = s
7.Stability: Routh–Hurwitz & root locusMedium
The loop in the diagram runs with K = 112 and L(s) = K/(s(s + 6)(s + 8)). By what factor m can the gain be raised before the closed loop becomes unstable?
L(s) = K/(s(s + 6)(s + 8))K = 112
m =
8.Stability: Routh–Hurwitz & root locusHard
For L(s) = K/((s + 6)(s² + 8s + 32)), find the angle of departure θd of the root locus from the complex pole in the upper half-plane, measured from the positive real axis.
L(s) = K/((s + 6)(s² + 8s + 32))
θd = °
9.Steady-state error & PID controlMedium
A ramp r(t) = 5t is applied to a unity-feedback loop with G(s) = 2/(s(s + 2)). Find the steady-state error ess.
G(s) = 2/(s(s + 2))r(t) = 5t
ess =
10.Steady-state error & PID controlHard
A PI controller C(s) = Kp + Ki/s drives the plant G(s) = 5/(s + 1) in a unity-feedback loop. The closed loop must have ωₙ = 6 rad/s and ζ = 0.7. Find the proportional gain Kp.
G(s) = 5/(s + 1)ωₙ = 6 rad/sζ = 0.7
Kp =
11.Bode plots & marginsMedium
In the series RLC band-pass filter shown the output is taken across R = 2 Ω, with L = 5 mH and C = 10 µF. Find the centre (resonant) frequency f0 in Hz.
R = 2 ΩL = 5 mHC = 10 µF
f0 = Hz
12.Bode plots & marginsHard
A unity-feedback loop has the open-loop transfer function L(s) = 10/(s(s + 4)). Find the gain crossover frequency ωc, where |L(jω)| = 1.
L(s) = 10/(s(s + 4))
ωc = rad/s
3Solutions
1.Laplace transforms
Answer: A = 3.25
Laplace transform: F(s) = ∫₀∞ f(t)·e−st dt turns derivatives into multiplications by s: ℒ{f′} = sF(s) − f(0), ℒ{f″} = s²F(s) − s·f(0) − f′(0). Standard pairs: 1 ↔ 1/s, e−at ↔ 1/(s + a), t·e−at ↔ 1/(s + a)², sin ωt ↔ ω/(s² + ω²), cos ωt ↔ s/(s² + ω²), and a shift s → s + σ multiplies the time function by e−σt. To invert a rational F(s), split it into partial fractions: the residue of a simple pole p is A = [(s − p)·F(s)] at s = p. Final value theorem: f(∞) = lims→0 s·F(s), valid only when all poles of s·F(s) lie in the left half-plane. Initial value theorem: f(0⁺) = lims→∞ s·F(s).
Factor the denominator
s² + 12s + 32 = (s + 4)(s + 8)
F(s) = A/(s + 4) + B/(s + 8)
Cover-up rule
Multiply by (s + 4) and set s = −4: the B-term vanishes.
A = (6s + 37)/(s + 8) |s = −4 = 13/4 = 3.25
Answer
A = 3.25
(B = 2.75, so f(t) = 3.25·e−4t + 2.75·e−8t)
2.Laplace transforms
Answer: y(0.4) = 4.342
Laplace transform: F(s) = ∫₀∞ f(t)·e−st dt turns derivatives into multiplications by s: ℒ{f′} = sF(s) − f(0), ℒ{f″} = s²F(s) − s·f(0) − f′(0). Standard pairs: 1 ↔ 1/s, e−at ↔ 1/(s + a), t·e−at ↔ 1/(s + a)², sin ωt ↔ ω/(s² + ω²), cos ωt ↔ s/(s² + ω²), and a shift s → s + σ multiplies the time function by e−σt. To invert a rational F(s), split it into partial fractions: the residue of a simple pole p is A = [(s − p)·F(s)] at s = p. Final value theorem: f(∞) = lims→0 s·F(s), valid only when all poles of s·F(s) lie in the left half-plane. Initial value theorem: f(0⁺) = lims→∞ s·F(s).
Transform the equation
(s² + 8s + 12)·Y(s) = 1s + 8 + 120/s
Y(s) = (s² + 8s + 120)/(s(s + 2)(s + 6))
Partial fractions
A = 120/(2·6) = 10
B = 108/((−2)·4) = −13.5
C = 108/((−6)·(−4)) = 4.5
Result
y(t) = 10 − 13.5·e−2t + 4.5·e−6t
y(0.4) = 4.342
Answer
y(0.4) = 4.342
Check: y(0) = A + B + C = 1.
3.Block diagrams
Answer: css = 38.92
Block-diagram algebra: blocks in series multiply (G₁·G₂), blocks in parallel add (G₁ + G₂), and a loop with forward path G and feedback path H reduces to T = G/(1 + G·H) for negative feedback and G/(1 − G·H) for positive feedback. Reduce inner loops first, then work outwards. The closed-loop poles are the roots of the characteristic equation 1 + G(s)H(s) = 0. For a stable loop, a step input of size A gives the steady-state output A·T(0); with unity feedback the steady-state error to a step is A/(1 + Kp) with Kp = G(0).
Block-diagram algebra: blocks in series multiply (G₁·G₂), blocks in parallel add (G₁ + G₂), and a loop with forward path G and feedback path H reduces to T = G/(1 + G·H) for negative feedback and G/(1 − G·H) for positive feedback. Reduce inner loops first, then work outwards. The closed-loop poles are the roots of the characteristic equation 1 + G(s)H(s) = 0. For a stable loop, a step input of size A gives the steady-state output A·T(0); with unity feedback the steady-state error to a step is A/(1 + Kp) with Kp = G(0).
Transfer functions
C/D = G/(1 + K·G) = 5/(s + 7 + 135)
C/R = K·G/(1 + K·G) = 135/(s + 7 + 135)
Steady state
css = 2·135/142 + 0.5·5/142 = 1.919
Answer
css = 1.919
A larger K reduces the effect of the disturbance, but never to zero with a proportional controller.
5.Step response
Answer: tp = 0.5859 s
Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).
Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).
For this loop ζωₙ = a/2 whatever K is: raising K adds overshoot but does not shorten the settling time.
7.Stability: Routh–Hurwitz & root locus
Answer: m = 6
Routh–Hurwitz criterion: a linear system is stable when every root of its characteristic polynomial lies in the left half of the s-plane. Write the coefficients alternately into the first two rows of the Routh array. Each entry of a new row comes from the two rows above it; for a cubic a₃s³ + a₂s² + a₁s + a₀ the s¹ entry is b₁ = (a₂·a₁ − a₃·a₀)/a₂. The number of sign changes in the first column equals the number of roots in the right half-plane. With a gain K in the coefficients, every first-column entry must stay positive: the gain that makes the s¹ entry zero is the stability limit, and the s² row then gives the frequency of the sustained oscillation.
Routh array
s³ + 14s² + 48s + K = 0
s³: 1, 48
s²: 14, K
s¹: (14·48 − K)/14
s⁰: K
Largest stable gain
Kmax = 14·48 = 672
Factor
m = 672/112 = 6
Answer
m = 6
This factor is the gain margin as a ratio: 15.56 dB.
8.Stability: Routh–Hurwitz & root locus
Answer: θd = 26.57 °
Root locus: as the gain K goes from 0 to ∞, the closed-loop poles, the roots of 1 + K·G(s) = 0, move from the open-loop poles to the open-loop zeros or to infinity. A point on the real axis belongs to the locus when the number of real poles and zeros to its right is odd. The n − m branches that go to infinity follow asymptotes at the angles (2q + 1)·180°/(n − m), which start from the centroid σₐ = (Σ poles − Σ zeros)/(n − m). Branches leave or join the real axis where dK/ds = 0. The angle condition ∠G(s) = 180° fixes the shape, and the magnitude condition K = 1/|G(s)| gives the gain at any point of the locus.
Pole locations
s² + 8s + 32 = 0 → s = −4 ± j4
s = −6
Angles from the other poles
∠(−4 + j4 + 6) = atan2(4, 2) = 63.43°
∠(−4 + j4 − (−4 − j4)) = ∠(j8) = 90°
Angle of departure
θd = 180° − 63.43° − 90° = 26.57°
Answer
θd = 26.57°
9.Steady-state error & PID control
Answer: ess = 5
Steady-state error: in a unity-feedback loop with open-loop transfer function G(s) the error is E(s) = R(s)/(1 + G(s)), and by the final value theorem ess = lims→0 s·E(s). The system type is the number of poles of G(s) at s = 0. The error constants are Kp = lim G(s), Kv = lim s·G(s) and Ka = lim s²·G(s), all for s → 0. A step of size A gives ess = A/(1 + Kp), a ramp A·t gives A/Kv and a parabola A·t²/2 gives A/Ka. A type-0 loop follows a step with a finite error, a type-1 loop follows it exactly and a ramp with a finite error.
Velocity constant
Kv = lim s·G(s) = 1
Ramp error
ess = 5/1 = 5
Answer
ess = 5
10.Steady-state error & PID control
Answer: Kp = 1.48
P, PI and PID control: the controller C(s) = Kp + Ki/s + Kd·s acts on the error. A proportional gain makes the loop faster and reduces the error of a type-0 plant, but never removes it. The integral term adds a pole at s = 0: the system type rises by one, and a step is followed without error. The derivative term adds damping. To choose gains, write the closed-loop characteristic polynomial and compare it with s² + 2ζωns + ωn². Then %OS = 100·e−ζπ/√(1−ζ²), tp = π/ωd with ωd = ωn√(1 − ζ²), and ts ≈ 4/(ζωn).
Characteristic polynomial
1 + C(s)G(s) = 0, multiplied by s(s + 1).
s² + (1 + 5Kp)s + 5Ki
Target polynomial
s² + 2·0.7·6s + 6² = s² + 8.4s + 36
Match the coefficients
1 + 5Kp = 8.4 → Kp = 1.48
Answer
Kp = 1.48
The integral term makes the loop type 1, so a step is followed without steady-state error.
11.Bode plots & margins
Answer: f0 = 711.8 Hz
Frequency response: substitute s = jω in the transfer function. The magnitude in decibels is 20·log₁₀|H(jω)| and the phase is the sum of the angles of the numerator factors minus those of the denominator factors. A first-order RC or RL filter has its corner (−3 dB) frequency at ωc = 1/(RC) or R/L, and fc = ωc/(2π); a low-pass filter gives |H| = 1/√(1 + (ω/ωc)²) and φ = −atan(ω/ωc). In the asymptotic (straight-line) Bode plot each pole bends the magnitude down by 20 dB/decade at its corner frequency, each zero bends it up by 20 dB/decade, and an integrator 1/s gives −20 dB/decade at all frequencies. Gain crossover ωc: |L(jω)| = 1 (0 dB); phase margin PM = 180° + ∠L(jωc). Phase crossover ω180: ∠L(jω) = −180°; gain margin GM = −20·log₁₀|L(jω180)| dB. The closed loop is stable when both margins are positive.
Resonant frequency
ω₀ = 1/√(LC) = 1/√(0.005·1 × 10⁻⁵) = 4472 rad/s
f₀ = ω₀/(2π) = 711.8 Hz
Answer
f0 = 711.8 Hz
12.Bode plots & margins
Answer: ωc = 2.192 rad/s
Frequency response: substitute s = jω in the transfer function. The magnitude in decibels is 20·log₁₀|H(jω)| and the phase is the sum of the angles of the numerator factors minus those of the denominator factors. A first-order RC or RL filter has its corner (−3 dB) frequency at ωc = 1/(RC) or R/L, and fc = ωc/(2π); a low-pass filter gives |H| = 1/√(1 + (ω/ωc)²) and φ = −atan(ω/ωc). In the asymptotic (straight-line) Bode plot each pole bends the magnitude down by 20 dB/decade at its corner frequency, each zero bends it up by 20 dB/decade, and an integrator 1/s gives −20 dB/decade at all frequencies. Gain crossover ωc: |L(jω)| = 1 (0 dB); phase margin PM = 180° + ∠L(jωc). Phase crossover ω180: ∠L(jω) = −180°; gain margin GM = −20·log₁₀|L(jω180)| dB. The closed loop is stable when both margins are positive.