In the print window, choose “Save as PDF” to keep a copy on your device.
1Formulas and methods
Stability: Routh–Hurwitz & root locus
Stability
all roots of the characteristic polynomial in the left half-plane
Routh array, s¹ entry of a cubic
b1 = (a2a1 − a3a0)/a2
Right half-plane roots
number of sign changes in the first column
Cubic s³ + a₂s² + a₁s + a₀
stable when all a > 0 and a₂·a₁ > a₀
K/(s(s + a)(s + b))
Kmax = ab(a + b), ω = √(ab)
Characteristic equation
1 + K·G(s) = 0
Asymptotes
σa = (Σp − Σz)/(n − m), θ = (2q + 1)·180°/(n − m)
Break-away and break-in points
dK/ds = 0
Magnitude condition
K = 1/|G(s)|
Angle of departure
θd = 180° − Σ∠(from other poles) + Σ∠(from zeros)
Method
Write the closed-loop characteristic polynomial: the denominator of 1 + K·G(s) = 0, multiplied out.
Put the coefficients alternately into the first two rows of the Routh array and build the remaining rows.
Count the sign changes in the first column: each one is a pole in the right half-plane. With K in the array, demand that every first-column entry stays positive.
For a root locus, mark the poles and zeros, the real-axis segments, the asymptotes from the centroid and the break points where dK/ds = 0. Use K = 1/|G(s)| for the gain at a point.
Steady-state error & PID control
System type
number of poles of G(s) at s = 0
Error constants
Kp = lim G(s), Kv = lim s·G(s), Ka = lim s²·G(s) (s → 0)
Step A
ess = A/(1 + Kp)
Ramp A·t
ess = A/Kv
Parabola A·t²/2
ess = A/Ka
PID controller
C(s) = Kp + Ki/s + Kd·s
Second-order target
s² + 2ζωns + ωn²
Overshoot and timing
%OS = 100·e−ζπ/√(1−ζ²), tp = π/ωd, ts ≈ 4/(ζωn)
Method
Count the poles of the open loop C(s)·G(s) at s = 0: that is the system type.
Work out the error constant that matches the input: Kp for a step, Kv for a ramp, Ka for a parabola.
Apply ess = A/(1 + Kp), A/Kv or A/Ka, or solve it for the gain you need.
For a damping or speed specification, write the closed-loop characteristic polynomial and match it with s² + 2ζω_n·s + ω_n².
2Practice problems
1.Laplace transformsMedium
F(s) = (6s + 29)/(s² + 8s + 7). Its inverse transform has the form f(t) = A·e−t + B·e−7t. Find the coefficient A by partial fractions.
F(s) = (6s + 29)/(s² + 8s + 7)
A =
2.Laplace transformsHard
A system obeys y″ + 4y′ + 3y = 9·u(t). It starts at rest (y(0) = 0, y′(0) = 0) and the input is a step u(t) = 2 for t ≥ 0. Use the Laplace transform to find the output y(0.75).
The plant G(s) = K/(s(s + 20)) is in a unity negative feedback loop. Find the gain K for which the closed loop is critically damped (two equal real poles).
G(s) = K/(s(s + 20))unity negative feedback
K =
4.Block diagramsHard
A proportional controller K drives the plant G(s) = 1/(s + 2) in a unity negative feedback loop. A disturbance step of size 1 enters at the plant input while R = 0. Find the smallest gain K that keeps the steady-state output at or below 0.01.
G(s) = 1/(s + 2)D = 1css ≤ 0.01
K =
5.Step responseMedium
A system has the transfer function G(s) = 3.5/(s² + 3s + 7) and receives a unit step input. Find the 2 % settling time ts of the step response, using ts ≈ 4/(ζωₙ).
G(s) = 3.5/(s² + 3s + 7)
ts = s
6.Step responseHard
A unity negative feedback loop has G(s) = K/(s(s + 6)). Find the gain K that gives a step response with 5 % overshoot.
G(s) = K/(s(s + 6))%OS = 5 %
K =
7.Stability: Routh–Hurwitz & root locusMedium
A unity-feedback loop has L(s) = K/((s + 1)(s + 4)(s + 5)), with K > 0. Find the largest gain Kmax for which the closed loop is stable.
L(s) = K/((s + 1)(s + 4)(s + 5))
Kmax =
8.Stability: Routh–Hurwitz & root locusHard
For L(s) = K/((s + 6)(s² + 2s + 2)), find the angle of departure θd of the root locus from the complex pole in the upper half-plane, measured from the positive real axis.
L(s) = K/((s + 6)(s² + 2s + 2))
θd = °
9.Steady-state error & PID controlMedium
A unity-feedback loop with G(s) = K/(s(s + 5)) must follow the ramp r(t) = 5t with a steady-state error of 0.2. Find the gain K.
G(s) = K/(s(s + 5))r(t) = 5tess = 0.2
K =
10.Steady-state error & PID controlHard
A proportional controller K drives the plant G(s) = 1/(s(s + 5)) in a unity-feedback loop. Find the gain K that gives the closed loop a damping ratio ζ = 0.8.
G(s) = 1/(s(s + 5))ζ = 0.8
K =
11.Bode plots & marginsMedium
In the series RLC band-pass filter shown the output is taken across R = 20 Ω, with L = 2 mH and C = 1 µF. Find the centre (resonant) frequency f0 in Hz.
R = 20 ΩL = 2 mHC = 1 µF
f0 = Hz
12.Bode plots & marginsHard
A unity-feedback loop has the open-loop transfer function L(s) = 1.3/(s(s + 1)). Find the gain crossover frequency ωc, where |L(jω)| = 1.
L(s) = 1.3/(s(s + 1))
ωc = rad/s
3Solutions
1.Laplace transforms
Answer: A = 3.833
Laplace transform: F(s) = ∫₀∞ f(t)·e−st dt turns derivatives into multiplications by s: ℒ{f′} = sF(s) − f(0), ℒ{f″} = s²F(s) − s·f(0) − f′(0). Standard pairs: 1 ↔ 1/s, e−at ↔ 1/(s + a), t·e−at ↔ 1/(s + a)², sin ωt ↔ ω/(s² + ω²), cos ωt ↔ s/(s² + ω²), and a shift s → s + σ multiplies the time function by e−σt. To invert a rational F(s), split it into partial fractions: the residue of a simple pole p is A = [(s − p)·F(s)] at s = p. Final value theorem: f(∞) = lims→0 s·F(s), valid only when all poles of s·F(s) lie in the left half-plane. Initial value theorem: f(0⁺) = lims→∞ s·F(s).
Factor the denominator
s² + 8s + 7 = (s + 1)(s + 7)
F(s) = A/(s + 1) + B/(s + 7)
Cover-up rule
Multiply by (s + 1) and set s = −1: the B-term vanishes.
A = (6s + 29)/(s + 7) |s = −1 = 23/6 = 3.833
Answer
A = 3.833
(B = 2.167, so f(t) = 3.833·e−t + 2.167·e−7t)
2.Laplace transforms
Answer: y(0.75) = 2.065
Laplace transform: F(s) = ∫₀∞ f(t)·e−st dt turns derivatives into multiplications by s: ℒ{f′} = sF(s) − f(0), ℒ{f″} = s²F(s) − s·f(0) − f′(0). Standard pairs: 1 ↔ 1/s, e−at ↔ 1/(s + a), t·e−at ↔ 1/(s + a)², sin ωt ↔ ω/(s² + ω²), cos ωt ↔ s/(s² + ω²), and a shift s → s + σ multiplies the time function by e−σt. To invert a rational F(s), split it into partial fractions: the residue of a simple pole p is A = [(s − p)·F(s)] at s = p. Final value theorem: f(∞) = lims→0 s·F(s), valid only when all poles of s·F(s) lie in the left half-plane. Initial value theorem: f(0⁺) = lims→∞ s·F(s).
Transform the equation
Y(s) = 18/(s(s + 1)(s + 3))
Partial fractions
A = 18/(1·3) = 6
B = 18/((−1)·2) = −9
C = 18/((−3)·(−2)) = 3
Output
y(t) = 6 − 9·e−t + 3·e−3t
y(0.75) = 2.065
Answer
y(0.75) = 2.065
3.Block diagrams
Answer: K = 100
Block-diagram algebra: blocks in series multiply (G₁·G₂), blocks in parallel add (G₁ + G₂), and a loop with forward path G and feedback path H reduces to T = G/(1 + G·H) for negative feedback and G/(1 − G·H) for positive feedback. Reduce inner loops first, then work outwards. The closed-loop poles are the roots of the characteristic equation 1 + G(s)H(s) = 0. For a stable loop, a step input of size A gives the steady-state output A·T(0); with unity feedback the steady-state error to a step is A/(1 + Kp) with Kp = G(0).
Characteristic equation
1 + K/(s(s + 20)) = 0 → s² + 20s + K = 0
Repeated root
A quadratic s² + βs + γ has a double root when β² = 4γ.
20² = 4K → K = 400/4 = 100
Answer
K = 100
Both closed-loop poles are then at s = −10.
4.Block diagrams
Answer: K = 98
Block-diagram algebra: blocks in series multiply (G₁·G₂), blocks in parallel add (G₁ + G₂), and a loop with forward path G and feedback path H reduces to T = G/(1 + G·H) for negative feedback and G/(1 − G·H) for positive feedback. Reduce inner loops first, then work outwards. The closed-loop poles are the roots of the characteristic equation 1 + G(s)H(s) = 0. For a stable loop, a step input of size A gives the steady-state output A·T(0); with unity feedback the steady-state error to a step is A/(1 + Kp) with Kp = G(0).
Disturbance response
css = D·G(0)/(1 + K·G(0)) = 1·1/(2 + 1K)
Solve for K
2 + 1K = 1·1/0.01 = 100
K = (100 − 2)/1 = 98
Answer
K = 98
5.Step response
Answer: ts = 2.667 s
Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).
Compare with the standard form
The denominator must match s² + 2ζωₙs + ωₙ².
ωₙ² = 7 → ωₙ = 2.646 rad/s
2ζωₙ = 3 → ζ = 3/(2·2.646) = 0.5669
Result
ζωₙ = 1.5 → ts ≈ 4/1.5 = 2.667 s
Answer
ts = 2.667 s
6.Step response
Answer: K = 18.9
Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).
Closed-loop transfer function
T(s) = K/(s² + 6s + K)
Damping ratio from the overshoot
ζ = −ln(0.05)/√(π² + ln²(0.05)) = 0.6901
Gain
ωₙ = 6/(2ζ) = 4.347 rad/s
K = ωₙ² = 18.9
Answer
K = 18.9
7.Stability: Routh–Hurwitz & root locus
Answer: Kmax = 270
Routh–Hurwitz criterion: a linear system is stable when every root of its characteristic polynomial lies in the left half of the s-plane. Write the coefficients alternately into the first two rows of the Routh array. Each entry of a new row comes from the two rows above it; for a cubic a₃s³ + a₂s² + a₁s + a₀ the s¹ entry is b₁ = (a₂·a₁ − a₃·a₀)/a₂. The number of sign changes in the first column equals the number of roots in the right half-plane. With a gain K in the coefficients, every first-column entry must stay positive: the gain that makes the s¹ entry zero is the stability limit, and the s² row then gives the frequency of the sustained oscillation.
Characteristic polynomial
s³ + 10s² + 29s + 20 + K = 0
Routh array
s³: 1, 29
s²: 10, 20 + K
s¹: (10·29 − 20 − K)/10
s⁰: 20 + K
Condition
The s¹ entry must stay positive.
K < 10·29 − 20 = 270
Answer
Kmax = 270
At the limit the loop oscillates at ω = √29 = 5.385 rad/s.
8.Stability: Routh–Hurwitz & root locus
Answer: θd = 78.69 °
Root locus: as the gain K goes from 0 to ∞, the closed-loop poles, the roots of 1 + K·G(s) = 0, move from the open-loop poles to the open-loop zeros or to infinity. A point on the real axis belongs to the locus when the number of real poles and zeros to its right is odd. The n − m branches that go to infinity follow asymptotes at the angles (2q + 1)·180°/(n − m), which start from the centroid σₐ = (Σ poles − Σ zeros)/(n − m). Branches leave or join the real axis where dK/ds = 0. The angle condition ∠G(s) = 180° fixes the shape, and the magnitude condition K = 1/|G(s)| gives the gain at any point of the locus.
Pole locations
s² + 2s + 2 = 0 → s = −1 ± j1
s = −6
Angles from the other poles
∠(−1 + j1 + 6) = atan2(1, 5) = 11.31°
∠(−1 + j1 − (−1 − j1)) = ∠(j2) = 90°
Angle of departure
θd = 180° − 11.31° − 90° = 78.69°
Answer
θd = 78.69°
9.Steady-state error & PID control
Answer: K = 125
Steady-state error: in a unity-feedback loop with open-loop transfer function G(s) the error is E(s) = R(s)/(1 + G(s)), and by the final value theorem ess = lims→0 s·E(s). The system type is the number of poles of G(s) at s = 0. The error constants are Kp = lim G(s), Kv = lim s·G(s) and Ka = lim s²·G(s), all for s → 0. A step of size A gives ess = A/(1 + Kp), a ramp A·t gives A/Kv and a parabola A·t²/2 gives A/Ka. A type-0 loop follows a step with a finite error, a type-1 loop follows it exactly and a ramp with a finite error.
Required velocity constant
Kv = A/ess = 5/0.2 = 25
Gain
K = 5·Kv = 125
Answer
K = 125
A large gain makes this loop very lightly damped: ζ = 0.2236. That conflict is why compensators are used.
10.Steady-state error & PID control
Answer: K = 9.766
P, PI and PID control: the controller C(s) = Kp + Ki/s + Kd·s acts on the error. A proportional gain makes the loop faster and reduces the error of a type-0 plant, but never removes it. The integral term adds a pole at s = 0: the system type rises by one, and a step is followed without error. The derivative term adds damping. To choose gains, write the closed-loop characteristic polynomial and compare it with s² + 2ζωns + ωn². Then %OS = 100·e−ζπ/√(1−ζ²), tp = π/ωd with ωd = ωn√(1 − ζ²), and ts ≈ 4/(ζωn).
Characteristic polynomial
s(s + 5) + 1K = s² + 5s + 1K
Natural frequency
2·0.8·ωₙ = 5 → ωₙ = 3.125 rad/s
Gain
1K = ωₙ² = 9.766 → K = 9.766
Answer
K = 9.766
11.Bode plots & margins
Answer: f0 = 3559 Hz
Frequency response: substitute s = jω in the transfer function. The magnitude in decibels is 20·log₁₀|H(jω)| and the phase is the sum of the angles of the numerator factors minus those of the denominator factors. A first-order RC or RL filter has its corner (−3 dB) frequency at ωc = 1/(RC) or R/L, and fc = ωc/(2π); a low-pass filter gives |H| = 1/√(1 + (ω/ωc)²) and φ = −atan(ω/ωc). In the asymptotic (straight-line) Bode plot each pole bends the magnitude down by 20 dB/decade at its corner frequency, each zero bends it up by 20 dB/decade, and an integrator 1/s gives −20 dB/decade at all frequencies. Gain crossover ωc: |L(jω)| = 1 (0 dB); phase margin PM = 180° + ∠L(jωc). Phase crossover ω180: ∠L(jω) = −180°; gain margin GM = −20·log₁₀|L(jω180)| dB. The closed loop is stable when both margins are positive.
Resonant frequency
ω₀ = 1/√(LC) = 1/√(0.002·1 × 10⁻⁶) = 22361 rad/s
f₀ = ω₀/(2π) = 3559 Hz
Answer
f0 = 3559 Hz
12.Bode plots & margins
Answer: ωc = 0.9449 rad/s
Frequency response: substitute s = jω in the transfer function. The magnitude in decibels is 20·log₁₀|H(jω)| and the phase is the sum of the angles of the numerator factors minus those of the denominator factors. A first-order RC or RL filter has its corner (−3 dB) frequency at ωc = 1/(RC) or R/L, and fc = ωc/(2π); a low-pass filter gives |H| = 1/√(1 + (ω/ωc)²) and φ = −atan(ω/ωc). In the asymptotic (straight-line) Bode plot each pole bends the magnitude down by 20 dB/decade at its corner frequency, each zero bends it up by 20 dB/decade, and an integrator 1/s gives −20 dB/decade at all frequencies. Gain crossover ωc: |L(jω)| = 1 (0 dB); phase margin PM = 180° + ∠L(jωc). Phase crossover ω180: ∠L(jω) = −180°; gain margin GM = −20·log₁₀|L(jω180)| dB. The closed loop is stable when both margins are positive.