In the print window, choose “Save as PDF” to keep a copy on your device.
1Formulas and methods
Stability: Routh–Hurwitz & root locus
Stability
all roots of the characteristic polynomial in the left half-plane
Routh array, s¹ entry of a cubic
b1 = (a2a1 − a3a0)/a2
Right half-plane roots
number of sign changes in the first column
Cubic s³ + a₂s² + a₁s + a₀
stable when all a > 0 and a₂·a₁ > a₀
K/(s(s + a)(s + b))
Kmax = ab(a + b), ω = √(ab)
Characteristic equation
1 + K·G(s) = 0
Asymptotes
σa = (Σp − Σz)/(n − m), θ = (2q + 1)·180°/(n − m)
Break-away and break-in points
dK/ds = 0
Magnitude condition
K = 1/|G(s)|
Angle of departure
θd = 180° − Σ∠(from other poles) + Σ∠(from zeros)
Method
Write the closed-loop characteristic polynomial: the denominator of 1 + K·G(s) = 0, multiplied out.
Put the coefficients alternately into the first two rows of the Routh array and build the remaining rows.
Count the sign changes in the first column: each one is a pole in the right half-plane. With K in the array, demand that every first-column entry stays positive.
For a root locus, mark the poles and zeros, the real-axis segments, the asymptotes from the centroid and the break points where dK/ds = 0. Use K = 1/|G(s)| for the gain at a point.
Steady-state error & PID control
System type
number of poles of G(s) at s = 0
Error constants
Kp = lim G(s), Kv = lim s·G(s), Ka = lim s²·G(s) (s → 0)
Step A
ess = A/(1 + Kp)
Ramp A·t
ess = A/Kv
Parabola A·t²/2
ess = A/Ka
PID controller
C(s) = Kp + Ki/s + Kd·s
Second-order target
s² + 2ζωns + ωn²
Overshoot and timing
%OS = 100·e−ζπ/√(1−ζ²), tp = π/ωd, ts ≈ 4/(ζωn)
Method
Count the poles of the open loop C(s)·G(s) at s = 0: that is the system type.
Work out the error constant that matches the input: Kp for a step, Kv for a ramp, Ka for a parabola.
Apply ess = A/(1 + Kp), A/Kv or A/Ka, or solve it for the gain you need.
For a damping or speed specification, write the closed-loop characteristic polynomial and match it with s² + 2ζω_n·s + ω_n².
2Practice problems
1.Laplace transformsMedium
Find f(t) for F(s) = (s + 28)/(s² + 8s + 52) by completing the square, and evaluate f(0.3).
F(s) = (s + 28)/(s² + 8s + 52)t = 0.3 s
f(0.3) =
2.Laplace transformsHard
A system obeys y″ + 5y′ + 6y = 15·u(t). It starts at rest (y(0) = 0, y′(0) = 0) and the input is a step u(t) = 10 for t ≥ 0. Use the Laplace transform to find the output y(0.6).
A unity negative feedback loop has G(s) = 8(s + 8)/((s + 3)(s + 4)). A step of size 5 is applied at the reference. Find the steady-state error ess.
G(s) = 8(s + 8)/((s + 3)(s + 4))R = 5
ess =
4.Block diagramsHard
A proportional controller K = 7 drives the plant G(s) = 2/(s + 5) in a unity negative feedback loop. A disturbance D enters at the plant input (it is added to the controller output). A reference step of size 5 and a disturbance step of size 1 are applied together. Find the steady-state output css.
K = 7G(s) = 2/(s + 5)D = 1R = 5
css =
5.Step responseMedium
A system has the transfer function G(s) = 21/(s² + 6s + 21) and receives a unit step input. Find the percent overshoot %OS of the step response.
G(s) = 21/(s² + 6s + 21)
%OS = %
6.Step responseHard
A series RLC circuit with R = 65 Ω, L = 20 mH and C = 4.7 µF is connected to a 10 V step at t = 0. The capacitor is uncharged and no current flows before the step. Find the percent overshoot %OS of the capacitor voltage.
R = 65 ΩL = 20 mHC = 4.7 µFV = 10 V
%OS = %
7.Stability: Routh–Hurwitz & root locusMedium
The loop in the diagram has the open-loop transfer function L(s) = K/(s(s + 6)(s + 8)). The gain is raised until the closed loop is on the edge of stability. Find the frequency ω of the sustained oscillation.
L(s) = K/(s(s + 6)(s + 8))
ω = rad/s
8.Stability: Routh–Hurwitz & root locusHard
For the loop L(s) = K/(s(s + 3)(s + 4)), find the gain K that puts a closed-loop pole at s = −1.5.
L(s) = K/(s(s + 3)(s + 4))s = −1.5
K =
9.Steady-state error & PID controlMedium
A process G(s) = 0.5/(5s + 1) is controlled by a proportional gain K = 1 in a unity-feedback loop. Find the steady-state error ess for a step, as a percentage of the step size.
G(s) = 0.5/(5s + 1)K = 1
ess = %
10.Steady-state error & PID controlHard
A proportional controller K = 10 drives the plant G(s) = 10/(s(s + 6)) in a unity-feedback loop. Find the 2 % settling time ts of the step response, using ts ≈ 4/(ζωₙ).
G(s) = 10/(s(s + 6))K = 10
ts = s
11.Bode plots & marginsMedium
Find the phase ∠G(jω) of G(s) = 41(s + 2)/(s(s + 8)) at ω = 5 rad/s, in degrees.
G(s) = 41(s + 2)/(s(s + 8))ω = 5 rad/s
∠G(jω) = °
12.Bode plots & marginsHard
A unity-feedback loop has the open-loop transfer function L(s) = 68/(s(s + 4)). Find the phase margin PM in degrees.
L(s) = 68/(s(s + 4))
PM = °
3Solutions
1.Laplace transforms
Answer: f(0.3) = 1.105
Laplace transform: F(s) = ∫₀∞ f(t)·e−st dt turns derivatives into multiplications by s: ℒ{f′} = sF(s) − f(0), ℒ{f″} = s²F(s) − s·f(0) − f′(0). Standard pairs: 1 ↔ 1/s, e−at ↔ 1/(s + a), t·e−at ↔ 1/(s + a)², sin ωt ↔ ω/(s² + ω²), cos ωt ↔ s/(s² + ω²), and a shift s → s + σ multiplies the time function by e−σt. To invert a rational F(s), split it into partial fractions: the residue of a simple pole p is A = [(s − p)·F(s)] at s = p. Final value theorem: f(∞) = lims→0 s·F(s), valid only when all poles of s·F(s) lie in the left half-plane. Initial value theorem: f(0⁺) = lims→∞ s·F(s).
Laplace transform: F(s) = ∫₀∞ f(t)·e−st dt turns derivatives into multiplications by s: ℒ{f′} = sF(s) − f(0), ℒ{f″} = s²F(s) − s·f(0) − f′(0). Standard pairs: 1 ↔ 1/s, e−at ↔ 1/(s + a), t·e−at ↔ 1/(s + a)², sin ωt ↔ ω/(s² + ω²), cos ωt ↔ s/(s² + ω²), and a shift s → s + σ multiplies the time function by e−σt. To invert a rational F(s), split it into partial fractions: the residue of a simple pole p is A = [(s − p)·F(s)] at s = p. Final value theorem: f(∞) = lims→0 s·F(s), valid only when all poles of s·F(s) lie in the left half-plane. Initial value theorem: f(0⁺) = lims→∞ s·F(s).
Transform the equation
Y(s) = 150/(s(s + 2)(s + 3))
Partial fractions
A = 150/(2·3) = 25
B = 150/((−2)·1) = −75
C = 150/((−3)·(−1)) = 50
Output
y(t) = 25 − 75·e−2t + 50·e−3t
y(0.6) = 10.68
Answer
y(0.6) = 10.68
3.Block diagrams
Answer: ess = 0.7895
Block-diagram algebra: blocks in series multiply (G₁·G₂), blocks in parallel add (G₁ + G₂), and a loop with forward path G and feedback path H reduces to T = G/(1 + G·H) for negative feedback and G/(1 − G·H) for positive feedback. Reduce inner loops first, then work outwards. The closed-loop poles are the roots of the characteristic equation 1 + G(s)H(s) = 0. For a stable loop, a step input of size A gives the steady-state output A·T(0); with unity feedback the steady-state error to a step is A/(1 + Kp) with Kp = G(0).
Position error constant
Kₚ = G(0) = 8·8/(3·4) = 5.333
Steady-state error
ess = A/(1 + Kₚ) = 5/(1 + 5.333) = 0.7895
Answer
ess = 0.7895
4.Block diagrams
Answer: css = 3.789
Block-diagram algebra: blocks in series multiply (G₁·G₂), blocks in parallel add (G₁ + G₂), and a loop with forward path G and feedback path H reduces to T = G/(1 + G·H) for negative feedback and G/(1 − G·H) for positive feedback. Reduce inner loops first, then work outwards. The closed-loop poles are the roots of the characteristic equation 1 + G(s)H(s) = 0. For a stable loop, a step input of size A gives the steady-state output A·T(0); with unity feedback the steady-state error to a step is A/(1 + Kp) with Kp = G(0).
Transfer functions
C/D = G/(1 + K·G) = 2/(s + 5 + 14)
C/R = K·G/(1 + K·G) = 14/(s + 5 + 14)
Steady state
css = 5·14/19 + 1·2/19 = 3.789
Answer
css = 3.789
A larger K reduces the effect of the disturbance, but never to zero with a proportional controller.
5.Step response
Answer: %OS = 6.583 %
Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).
Compare with the standard form
The denominator must match s² + 2ζωₙs + ωₙ².
ωₙ² = 21 → ωₙ = 4.583 rad/s
2ζωₙ = 6 → ζ = 6/(2·4.583) = 0.6547
Result
%OS = 100·e−ζπ/√(1−ζ²) = 100·e−2.721 = 6.583 %
Answer
%OS = 6.583 %
6.Step response
Answer: %OS = 16.44 %
Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).
Routh–Hurwitz criterion: a linear system is stable when every root of its characteristic polynomial lies in the left half of the s-plane. Write the coefficients alternately into the first two rows of the Routh array. Each entry of a new row comes from the two rows above it; for a cubic a₃s³ + a₂s² + a₁s + a₀ the s¹ entry is b₁ = (a₂·a₁ − a₃·a₀)/a₂. The number of sign changes in the first column equals the number of roots in the right half-plane. With a gain K in the coefficients, every first-column entry must stay positive: the gain that makes the s¹ entry zero is the stability limit, and the s² row then gives the frequency of the sustained oscillation.
Routh array
s³ + 14s² + 48s + K = 0
s³: 1, 48
s²: 14, K
s¹: (14·48 − K)/14
s⁰: K
Critical gain
K = 14·48 = 672
Auxiliary equation
At the critical gain the s¹ row is zero; the s² row gives the poles on the imaginary axis.
14s² + 672 = 0 → s = ±j√48
ω = 6.928 rad/s
Answer
ω = 6.928 rad/s
8.Stability: Routh–Hurwitz & root locus
Answer: K = 5.625
Root locus: as the gain K goes from 0 to ∞, the closed-loop poles, the roots of 1 + K·G(s) = 0, move from the open-loop poles to the open-loop zeros or to infinity. A point on the real axis belongs to the locus when the number of real poles and zeros to its right is odd. The n − m branches that go to infinity follow asymptotes at the angles (2q + 1)·180°/(n − m), which start from the centroid σₐ = (Σ poles − Σ zeros)/(n − m). Branches leave or join the real axis where dK/ds = 0. The angle condition ∠G(s) = 180° fixes the shape, and the magnitude condition K = 1/|G(s)| gives the gain at any point of the locus.
Magnitude condition
K = |s|·|s + 3|·|s + 4|
Evaluate at the point
K = 1.5·1.5·2.5 = 5.625
Answer
K = 5.625
Check: s(s + 3)(s + 4) + K is zero at s = −1.5.
9.Steady-state error & PID control
Answer: ess = 66.67 %
Steady-state error: in a unity-feedback loop with open-loop transfer function G(s) the error is E(s) = R(s)/(1 + G(s)), and by the final value theorem ess = lims→0 s·E(s). The system type is the number of poles of G(s) at s = 0. The error constants are Kp = lim G(s), Kv = lim s·G(s) and Ka = lim s²·G(s), all for s → 0. A step of size A gives ess = A/(1 + Kp), a ramp A·t gives A/Kv and a parabola A·t²/2 gives A/Ka. A type-0 loop follows a step with a finite error, a type-1 loop follows it exactly and a ramp with a finite error.
Position constant
Kp = 1·0.5 = 0.5
Step error
ess = 100/(1 + 0.5) = 66.67 %
Answer
ess = 66.67 %
10.Steady-state error & PID control
Answer: ts = 1.333 s
P, PI and PID control: the controller C(s) = Kp + Ki/s + Kd·s acts on the error. A proportional gain makes the loop faster and reduces the error of a type-0 plant, but never removes it. The integral term adds a pole at s = 0: the system type rises by one, and a step is followed without error. The derivative term adds damping. To choose gains, write the closed-loop characteristic polynomial and compare it with s² + 2ζωns + ωn². Then %OS = 100·e−ζπ/√(1−ζ²), tp = π/ωd with ωd = ωn√(1 − ζ²), and ts ≈ 4/(ζωn).
Characteristic polynomial
s(s + 6) + 10·10 = s² + 6s + 100
ωₙ and ζ
ωₙ = √100 = 10 rad/s
ζ = 6/(2·10) = 0.3
Settling time
ζωₙ = 6/2 = 3
ts ≈ 4/3 = 1.333 s
Answer
ts = 1.333 s
The settling time does not depend on K here: raising K only makes the response oscillate faster.
11.Bode plots & margins
Answer: ∠G(jω) = −53.81 °
Frequency response: substitute s = jω in the transfer function. The magnitude in decibels is 20·log₁₀|H(jω)| and the phase is the sum of the angles of the numerator factors minus those of the denominator factors. A first-order RC or RL filter has its corner (−3 dB) frequency at ωc = 1/(RC) or R/L, and fc = ωc/(2π); a low-pass filter gives |H| = 1/√(1 + (ω/ωc)²) and φ = −atan(ω/ωc). In the asymptotic (straight-line) Bode plot each pole bends the magnitude down by 20 dB/decade at its corner frequency, each zero bends it up by 20 dB/decade, and an integrator 1/s gives −20 dB/decade at all frequencies. Gain crossover ωc: |L(jω)| = 1 (0 dB); phase margin PM = 180° + ∠L(jωc). Phase crossover ω180: ∠L(jω) = −180°; gain margin GM = −20·log₁₀|L(jω180)| dB. The closed loop is stable when both margins are positive.
Frequency response: substitute s = jω in the transfer function. The magnitude in decibels is 20·log₁₀|H(jω)| and the phase is the sum of the angles of the numerator factors minus those of the denominator factors. A first-order RC or RL filter has its corner (−3 dB) frequency at ωc = 1/(RC) or R/L, and fc = ωc/(2π); a low-pass filter gives |H| = 1/√(1 + (ω/ωc)²) and φ = −atan(ω/ωc). In the asymptotic (straight-line) Bode plot each pole bends the magnitude down by 20 dB/decade at its corner frequency, each zero bends it up by 20 dB/decade, and an integrator 1/s gives −20 dB/decade at all frequencies. Gain crossover ωc: |L(jω)| = 1 (0 dB); phase margin PM = 180° + ∠L(jωc). Phase crossover ω180: ∠L(jω) = −180°; gain margin GM = −20·log₁₀|L(jω180)| dB. The closed loop is stable when both margins are positive.