In the print window, choose “Save as PDF” to keep a copy on your device.
1Formulas and methods
Stability: Routh–Hurwitz & root locus
Stability
all roots of the characteristic polynomial in the left half-plane
Routh array, s¹ entry of a cubic
b1 = (a2a1 − a3a0)/a2
Right half-plane roots
number of sign changes in the first column
Cubic s³ + a₂s² + a₁s + a₀
stable when all a > 0 and a₂·a₁ > a₀
K/(s(s + a)(s + b))
Kmax = ab(a + b), ω = √(ab)
Characteristic equation
1 + K·G(s) = 0
Asymptotes
σa = (Σp − Σz)/(n − m), θ = (2q + 1)·180°/(n − m)
Break-away and break-in points
dK/ds = 0
Magnitude condition
K = 1/|G(s)|
Angle of departure
θd = 180° − Σ∠(from other poles) + Σ∠(from zeros)
Method
Write the closed-loop characteristic polynomial: the denominator of 1 + K·G(s) = 0, multiplied out.
Put the coefficients alternately into the first two rows of the Routh array and build the remaining rows.
Count the sign changes in the first column: each one is a pole in the right half-plane. With K in the array, demand that every first-column entry stays positive.
For a root locus, mark the poles and zeros, the real-axis segments, the asymptotes from the centroid and the break points where dK/ds = 0. Use K = 1/|G(s)| for the gain at a point.
Steady-state error & PID control
System type
number of poles of G(s) at s = 0
Error constants
Kp = lim G(s), Kv = lim s·G(s), Ka = lim s²·G(s) (s → 0)
Step A
ess = A/(1 + Kp)
Ramp A·t
ess = A/Kv
Parabola A·t²/2
ess = A/Ka
PID controller
C(s) = Kp + Ki/s + Kd·s
Second-order target
s² + 2ζωns + ωn²
Overshoot and timing
%OS = 100·e−ζπ/√(1−ζ²), tp = π/ωd, ts ≈ 4/(ζωn)
Method
Count the poles of the open loop C(s)·G(s) at s = 0: that is the system type.
Work out the error constant that matches the input: Kp for a step, Kv for a ramp, Ka for a parabola.
Apply ess = A/(1 + Kp), A/Kv or A/Ka, or solve it for the gain you need.
For a damping or speed specification, write the closed-loop characteristic polynomial and match it with s² + 2ζω_n·s + ω_n².
2Practice problems
1.Laplace transformsMedium
Find f(t) for F(s) = 45/(s(s + 3)(s + 6)) by partial fractions, and evaluate f(0.5).
F(s) = 45/(s(s + 3)(s + 6))t = 0.5 s
f(0.5) =
2.Laplace transformsHard
A system obeys y″ + 6y′ + 5y = 5·u(t), with y(0) = 5 and y′(0) = 0. At t = 0 a step input u(t) = 2 is applied. Use the Laplace transform to find y(1.2).
A unity negative feedback loop has G(s) = 2(s + 2)/((s + 3)(s + 9)). A step of size 10 is applied at the reference. Find the steady-state error ess.
G(s) = 2(s + 2)/((s + 3)(s + 9))R = 10
ess =
4.Block diagramsHard
The plant G(s) = K/(s(s + 5)(s + 8)) is in a unity negative feedback loop. At the largest stable gain the loop oscillates. Find the frequency of oscillation ω in rad/s.
G(s) = K/(s(s + 5)(s + 8))unity negative feedback
ω = rad/s
5.Step responseMedium
A system has the transfer function G(s) = 66/(s² + 5s + 22) and receives a unit step input. Find the natural frequency ωn in rad/s.
G(s) = 66/(s² + 5s + 22)
ωn = rad/s
6.Step responseHard
A unity negative feedback loop has G(s) = K/(s(s + 10)). Find the gain K that gives a step response with 30 % overshoot.
G(s) = K/(s(s + 10))%OS = 30 %
K =
7.Stability: Routh–Hurwitz & root locusMedium
The loop in the diagram has the open-loop transfer function L(s) = K/(s(s + 2)(s + 4)). Find the largest gain Kmax for which the closed loop is stable.
L(s) = K/(s(s + 2)(s + 4))
Kmax =
8.Stability: Routh–Hurwitz & root locusHard
The root locus of L(s) = K/(s(s + 10)) is shown. Find the gain K for which the closed-loop poles have the damping ratio ζ = 0.4.
L(s) = K/(s(s + 10))ζ = 0.4
K =
9.Steady-state error & PID controlMedium
A process G(s) = 1/(5s + 1) is controlled by a proportional gain K = 2 in a unity-feedback loop. Find the steady-state error ess for a step, as a percentage of the step size.
G(s) = 1/(5s + 1)K = 2
ess = %
10.Steady-state error & PID controlHard
A proportional controller K = 50 drives the plant G(s) = 10/(s(s + 6)) in a unity-feedback loop. Find the peak time tp of the step response.
G(s) = 10/(s(s + 6))K = 50
tp = s
11.Bode plots & marginsMedium
In the series RLC band-pass filter shown the output is taken across R = 100 Ω, with L = 50 mH and C = 0.47 µF. Find the centre (resonant) frequency f0 in Hz.
R = 100 ΩL = 50 mHC = 0.47 µF
f0 = Hz
12.Bode plots & marginsHard
A unity-feedback loop has the open-loop transfer function L(s) = 16/(s(s + 2)). Find the gain crossover frequency ωc, where |L(jω)| = 1.
L(s) = 16/(s(s + 2))
ωc = rad/s
3Solutions
1.Laplace transforms
Answer: f(0.5) = 1.509
Laplace transform: F(s) = ∫₀∞ f(t)·e−st dt turns derivatives into multiplications by s: ℒ{f′} = sF(s) − f(0), ℒ{f″} = s²F(s) − s·f(0) − f′(0). Standard pairs: 1 ↔ 1/s, e−at ↔ 1/(s + a), t·e−at ↔ 1/(s + a)², sin ωt ↔ ω/(s² + ω²), cos ωt ↔ s/(s² + ω²), and a shift s → s + σ multiplies the time function by e−σt. To invert a rational F(s), split it into partial fractions: the residue of a simple pole p is A = [(s − p)·F(s)] at s = p. Final value theorem: f(∞) = lims→0 s·F(s), valid only when all poles of s·F(s) lie in the left half-plane. Initial value theorem: f(0⁺) = lims→∞ s·F(s).
Partial fractions
F(s) = A/s + B/(s + 3) + C/(s + 6)
A = 45/(3·6) = 2.5
B = 45/((−3)·3) = −5
C = 45/((−6)·(−3)) = 2.5
Inverse transform
f(t) = 2.5 − 5·e−3t + 2.5·e−6t
Evaluate
f(0.5) = 2.5 − 5·e−3·0.5 + 2.5·e−6·0.5 = 1.509
Answer
f(0.5) = 1.509
2.Laplace transforms
Answer: y(1.2) = 3.128
Laplace transform: F(s) = ∫₀∞ f(t)·e−st dt turns derivatives into multiplications by s: ℒ{f′} = sF(s) − f(0), ℒ{f″} = s²F(s) − s·f(0) − f′(0). Standard pairs: 1 ↔ 1/s, e−at ↔ 1/(s + a), t·e−at ↔ 1/(s + a)², sin ωt ↔ ω/(s² + ω²), cos ωt ↔ s/(s² + ω²), and a shift s → s + σ multiplies the time function by e−σt. To invert a rational F(s), split it into partial fractions: the residue of a simple pole p is A = [(s − p)·F(s)] at s = p. Final value theorem: f(∞) = lims→0 s·F(s), valid only when all poles of s·F(s) lie in the left half-plane. Initial value theorem: f(0⁺) = lims→∞ s·F(s).
Transform the equation
(s² + 6s + 5)·Y(s) = 5s + 30 + 10/s
Y(s) = (5s² + 30s + 10)/(s(s + 1)(s + 5))
Partial fractions
A = 10/(1·5) = 2
B = −15/((−1)·4) = 3.75
C = −15/((−5)·(−4)) = −0.75
Result
y(t) = 2 + 3.75·e−t − 0.75·e−5t
y(1.2) = 3.128
Answer
y(1.2) = 3.128
Check: y(0) = A + B + C = 5.
3.Block diagrams
Answer: ess = 8.71
Block-diagram algebra: blocks in series multiply (G₁·G₂), blocks in parallel add (G₁ + G₂), and a loop with forward path G and feedback path H reduces to T = G/(1 + G·H) for negative feedback and G/(1 − G·H) for positive feedback. Reduce inner loops first, then work outwards. The closed-loop poles are the roots of the characteristic equation 1 + G(s)H(s) = 0. For a stable loop, a step input of size A gives the steady-state output A·T(0); with unity feedback the steady-state error to a step is A/(1 + Kp) with Kp = G(0).
Position error constant
Kₚ = G(0) = 2·2/(3·9) = 0.1481
Steady-state error
ess = A/(1 + Kₚ) = 10/(1 + 0.1481) = 8.71
Answer
ess = 8.71
4.Block diagrams
Answer: ω = 6.325 rad/s
Block-diagram algebra: blocks in series multiply (G₁·G₂), blocks in parallel add (G₁ + G₂), and a loop with forward path G and feedback path H reduces to T = G/(1 + G·H) for negative feedback and G/(1 − G·H) for positive feedback. Reduce inner loops first, then work outwards. The closed-loop poles are the roots of the characteristic equation 1 + G(s)H(s) = 0. For a stable loop, a step input of size A gives the steady-state output A·T(0); with unity feedback the steady-state error to a step is A/(1 + Kp) with Kp = G(0).
Characteristic equation
s³ + 13s² + 40s + K = 0
Routh array
s³ | 1 40
s² | 13 K
s¹ | (13·40 − K)/13
s⁰ | K
Stability limit
All entries of the first column must be positive.
Kmax = 13·40 = 520
Frequency of oscillation
13·(jω)² + 520 = 0 → ω² = 520/13 = 40
ω = 6.325 rad/s
Answer
ω = 6.325 rad/s
5.Step response
Answer: ωn = 4.69 rad/s
Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).
Compare with the standard form
The denominator must match s² + 2ζωₙs + ωₙ².
ωₙ² = 22 → ωₙ = 4.69 rad/s
2ζωₙ = 5 → ζ = 5/(2·4.69) = 0.533
Result
ωₙ = 4.69 rad/s
Answer
ωn = 4.69 rad/s
6.Step response
Answer: K = 195.2
Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).
Closed-loop transfer function
T(s) = K/(s² + 10s + K)
Damping ratio from the overshoot
ζ = −ln(0.3)/√(π² + ln²(0.3)) = 0.3579
Gain
ωₙ = 10/(2ζ) = 13.97 rad/s
K = ωₙ² = 195.2
Answer
K = 195.2
7.Stability: Routh–Hurwitz & root locus
Answer: Kmax = 48
Routh–Hurwitz criterion: a linear system is stable when every root of its characteristic polynomial lies in the left half of the s-plane. Write the coefficients alternately into the first two rows of the Routh array. Each entry of a new row comes from the two rows above it; for a cubic a₃s³ + a₂s² + a₁s + a₀ the s¹ entry is b₁ = (a₂·a₁ − a₃·a₀)/a₂. The number of sign changes in the first column equals the number of roots in the right half-plane. With a gain K in the coefficients, every first-column entry must stay positive: the gain that makes the s¹ entry zero is the stability limit, and the s² row then gives the frequency of the sustained oscillation.
Characteristic equation
s³ + 6s² + 8s + K = 0
Routh array
s³: 1, 8
s²: 6, K
s¹: (6·8 − K)/6
s⁰: K
Conditions
Every entry of the first column must be positive.
K > 0
6·8 − K > 0 → K < 48
Answer
Kmax = 48
At K = 48 the closed loop oscillates at ω = √8 = 2.828 rad/s.
8.Stability: Routh–Hurwitz & root locus
Answer: K = 156.2
Root locus: as the gain K goes from 0 to ∞, the closed-loop poles, the roots of 1 + K·G(s) = 0, move from the open-loop poles to the open-loop zeros or to infinity. A point on the real axis belongs to the locus when the number of real poles and zeros to its right is odd. The n − m branches that go to infinity follow asymptotes at the angles (2q + 1)·180°/(n − m), which start from the centroid σₐ = (Σ poles − Σ zeros)/(n − m). Branches leave or join the real axis where dK/ds = 0. The angle condition ∠G(s) = 180° fixes the shape, and the magnitude condition K = 1/|G(s)| gives the gain at any point of the locus.
Compare with the standard form
s² + 10s + K = s² + 2ζωₙs + ωₙ²
2·0.4·ωₙ = 10 → ωₙ = 12.5 rad/s
Gain
K = ωₙ² = 12.5² = 156.2
Answer
K = 156.2
The closed-loop poles sit where the ζ line crosses the vertical branch at s = −5.
9.Steady-state error & PID control
Answer: ess = 33.33 %
Steady-state error: in a unity-feedback loop with open-loop transfer function G(s) the error is E(s) = R(s)/(1 + G(s)), and by the final value theorem ess = lims→0 s·E(s). The system type is the number of poles of G(s) at s = 0. The error constants are Kp = lim G(s), Kv = lim s·G(s) and Ka = lim s²·G(s), all for s → 0. A step of size A gives ess = A/(1 + Kp), a ramp A·t gives A/Kv and a parabola A·t²/2 gives A/Ka. A type-0 loop follows a step with a finite error, a type-1 loop follows it exactly and a ramp with a finite error.
Position constant
Kp = 2·1 = 2
Step error
ess = 100/(1 + 2) = 33.33 %
Answer
ess = 33.33 %
10.Steady-state error & PID control
Answer: tp = 0.1418 s
P, PI and PID control: the controller C(s) = Kp + Ki/s + Kd·s acts on the error. A proportional gain makes the loop faster and reduces the error of a type-0 plant, but never removes it. The integral term adds a pole at s = 0: the system type rises by one, and a step is followed without error. The derivative term adds damping. To choose gains, write the closed-loop characteristic polynomial and compare it with s² + 2ζωns + ωn². Then %OS = 100·e−ζπ/√(1−ζ²), tp = π/ωd with ωd = ωn√(1 − ζ²), and ts ≈ 4/(ζωn).
Characteristic polynomial
s(s + 6) + 50·10 = s² + 6s + 500
ωₙ and ζ
ωₙ = √500 = 22.36 rad/s
ζ = 6/(2·22.36) = 0.1342
Peak time
ωd = 22.36·√(1 − 0.1342²) = 22.16 rad/s
tp = π/22.16 = 0.1418 s
Answer
tp = 0.1418 s
11.Bode plots & margins
Answer: f0 = 1038 Hz
Frequency response: substitute s = jω in the transfer function. The magnitude in decibels is 20·log₁₀|H(jω)| and the phase is the sum of the angles of the numerator factors minus those of the denominator factors. A first-order RC or RL filter has its corner (−3 dB) frequency at ωc = 1/(RC) or R/L, and fc = ωc/(2π); a low-pass filter gives |H| = 1/√(1 + (ω/ωc)²) and φ = −atan(ω/ωc). In the asymptotic (straight-line) Bode plot each pole bends the magnitude down by 20 dB/decade at its corner frequency, each zero bends it up by 20 dB/decade, and an integrator 1/s gives −20 dB/decade at all frequencies. Gain crossover ωc: |L(jω)| = 1 (0 dB); phase margin PM = 180° + ∠L(jωc). Phase crossover ω180: ∠L(jω) = −180°; gain margin GM = −20·log₁₀|L(jω180)| dB. The closed loop is stable when both margins are positive.
Resonant frequency
ω₀ = 1/√(LC) = 1/√(0.05·4.7 × 10⁻⁷) = 6523 rad/s
f₀ = ω₀/(2π) = 1038 Hz
Answer
f0 = 1038 Hz
12.Bode plots & margins
Answer: ωc = 3.758 rad/s
Frequency response: substitute s = jω in the transfer function. The magnitude in decibels is 20·log₁₀|H(jω)| and the phase is the sum of the angles of the numerator factors minus those of the denominator factors. A first-order RC or RL filter has its corner (−3 dB) frequency at ωc = 1/(RC) or R/L, and fc = ωc/(2π); a low-pass filter gives |H| = 1/√(1 + (ω/ωc)²) and φ = −atan(ω/ωc). In the asymptotic (straight-line) Bode plot each pole bends the magnitude down by 20 dB/decade at its corner frequency, each zero bends it up by 20 dB/decade, and an integrator 1/s gives −20 dB/decade at all frequencies. Gain crossover ωc: |L(jω)| = 1 (0 dB); phase margin PM = 180° + ∠L(jωc). Phase crossover ω180: ∠L(jω) = −180°; gain margin GM = −20·log₁₀|L(jω180)| dB. The closed loop is stable when both margins are positive.