In the print window, choose “Save as PDF” to keep a copy on your device.
1Formulas and methods
Stability: Routh–Hurwitz & root locus
Stability
all roots of the characteristic polynomial in the left half-plane
Routh array, s¹ entry of a cubic
b1 = (a2a1 − a3a0)/a2
Right half-plane roots
number of sign changes in the first column
Cubic s³ + a₂s² + a₁s + a₀
stable when all a > 0 and a₂·a₁ > a₀
K/(s(s + a)(s + b))
Kmax = ab(a + b), ω = √(ab)
Characteristic equation
1 + K·G(s) = 0
Asymptotes
σa = (Σp − Σz)/(n − m), θ = (2q + 1)·180°/(n − m)
Break-away and break-in points
dK/ds = 0
Magnitude condition
K = 1/|G(s)|
Angle of departure
θd = 180° − Σ∠(from other poles) + Σ∠(from zeros)
Method
Write the closed-loop characteristic polynomial: the denominator of 1 + K·G(s) = 0, multiplied out.
Put the coefficients alternately into the first two rows of the Routh array and build the remaining rows.
Count the sign changes in the first column: each one is a pole in the right half-plane. With K in the array, demand that every first-column entry stays positive.
For a root locus, mark the poles and zeros, the real-axis segments, the asymptotes from the centroid and the break points where dK/ds = 0. Use K = 1/|G(s)| for the gain at a point.
Steady-state error & PID control
System type
number of poles of G(s) at s = 0
Error constants
Kp = lim G(s), Kv = lim s·G(s), Ka = lim s²·G(s) (s → 0)
Step A
ess = A/(1 + Kp)
Ramp A·t
ess = A/Kv
Parabola A·t²/2
ess = A/Ka
PID controller
C(s) = Kp + Ki/s + Kd·s
Second-order target
s² + 2ζωns + ωn²
Overshoot and timing
%OS = 100·e−ζπ/√(1−ζ²), tp = π/ωd, ts ≈ 4/(ζωn)
Method
Count the poles of the open loop C(s)·G(s) at s = 0: that is the system type.
Work out the error constant that matches the input: Kp for a step, Kv for a ramp, Ka for a parabola.
Apply ess = A/(1 + Kp), A/Kv or A/Ka, or solve it for the gain you need.
For a damping or speed specification, write the closed-loop characteristic polynomial and match it with s² + 2ζω_n·s + ω_n².
2Practice problems
1.Laplace transformsMedium
F(s) = (3s + 28)/(s² + 7s + 12). Its inverse transform has the form f(t) = A·e−3t + B·e−4t. Find the coefficient A by partial fractions.
F(s) = (3s + 28)/(s² + 7s + 12)
A =
2.Laplace transformsHard
A system obeys y″ + 9y′ + 20y = 40·u(t). It starts at rest (y(0) = 0, y′(0) = 0) and the input is a step u(t) = 10 for t ≥ 0. Use the Laplace transform to find the output y(0.3).
A unity negative feedback loop has G(s) = 12(s + 4)/((s + 2)(s + 5)). A step of size 1 is applied at the reference. Find the steady-state error ess.
G(s) = 12(s + 4)/((s + 2)(s + 5))R = 1
ess =
4.Block diagramsHard
The plant G(s) = K/(s(s + 4)(s + 8)) is in a unity negative feedback loop. Use the Routh–Hurwitz criterion to find the largest gain Kmax for which the closed loop is stable.
G(s) = K/(s(s + 4)(s + 8))unity negative feedback
Kmax =
5.Step responseMedium
A system has the transfer function G(s) = 52/(s² + 3s + 52) and receives a unit step input. Find the 2 % settling time ts of the step response, using ts ≈ 4/(ζωₙ).
G(s) = 52/(s² + 3s + 52)
ts = s
6.Step responseHard
A unity negative feedback loop has G(s) = 295/(s(s + 20)). Find the 2 % settling time ts of the closed-loop step response, using ts ≈ 4/(ζωₙ).
G(s) = 295/(s(s + 20))
ts = s
7.Stability: Routh–Hurwitz & root locusMedium
The loop in the diagram has the open-loop transfer function L(s) = K/(s(s + 2)(s + 5)). The gain is raised until the closed loop is on the edge of stability. Find the frequency ω of the sustained oscillation.
L(s) = K/(s(s + 2)(s + 5))
ω = rad/s
8.Stability: Routh–Hurwitz & root locusHard
For L(s) = K/((s + 2)(s² + 8s + 17)), find the angle of departure θd of the root locus from the complex pole in the upper half-plane, measured from the positive real axis.
L(s) = K/((s + 2)(s² + 8s + 17))
θd = °
9.Steady-state error & PID controlMedium
A unity-feedback loop with G(s) = K/(s(s + 2)) must follow the ramp r(t) = 1t with a steady-state error of 0.02. Find the gain K.
G(s) = K/(s(s + 2))r(t) = 1tess = 0.02
K =
10.Steady-state error & PID controlHard
A PI controller C(s) = 5 + 4/s drives the plant G(s) = 5/((s + 4)(s + 5)) in a unity-feedback loop. Find the steady-state error ess for the ramp input r(t) = 5t.
C(s) = 5 + 4/sG(s) = 5/((s + 4)(s + 5))r(t) = 5t
ess =
11.Bode plots & marginsMedium
The RC low-pass filter shown has R = 22 kΩ, C = 4.7 nF. A sinusoidal input of 4.6 kHz is applied. Find the phase shift φ of vout relative to vin, in degrees.
R = 22 kΩC = 4.7 nFf = 4.6 kHz
φ = °
12.Bode plots & marginsHard
A unity-feedback loop has the open-loop transfer function L(s) = K/(s(s + 5)(s + 10)). Find the gain K that gives a gain margin of 4 dB.
L(s) = K/(s(s + 5)(s + 10))GM = 4 dB
K =
3Solutions
1.Laplace transforms
Answer: A = 19
Laplace transform: F(s) = ∫₀∞ f(t)·e−st dt turns derivatives into multiplications by s: ℒ{f′} = sF(s) − f(0), ℒ{f″} = s²F(s) − s·f(0) − f′(0). Standard pairs: 1 ↔ 1/s, e−at ↔ 1/(s + a), t·e−at ↔ 1/(s + a)², sin ωt ↔ ω/(s² + ω²), cos ωt ↔ s/(s² + ω²), and a shift s → s + σ multiplies the time function by e−σt. To invert a rational F(s), split it into partial fractions: the residue of a simple pole p is A = [(s − p)·F(s)] at s = p. Final value theorem: f(∞) = lims→0 s·F(s), valid only when all poles of s·F(s) lie in the left half-plane. Initial value theorem: f(0⁺) = lims→∞ s·F(s).
Factor the denominator
s² + 7s + 12 = (s + 3)(s + 4)
F(s) = A/(s + 3) + B/(s + 4)
Cover-up rule
Multiply by (s + 3) and set s = −3: the B-term vanishes.
A = (3s + 28)/(s + 4) |s = −3 = 19/1 = 19
Answer
A = 19
(B = −16, so f(t) = 19·e−3t − 16·e−4t)
2.Laplace transforms
Answer: y(0.3) = 7.731
Laplace transform: F(s) = ∫₀∞ f(t)·e−st dt turns derivatives into multiplications by s: ℒ{f′} = sF(s) − f(0), ℒ{f″} = s²F(s) − s·f(0) − f′(0). Standard pairs: 1 ↔ 1/s, e−at ↔ 1/(s + a), t·e−at ↔ 1/(s + a)², sin ωt ↔ ω/(s² + ω²), cos ωt ↔ s/(s² + ω²), and a shift s → s + σ multiplies the time function by e−σt. To invert a rational F(s), split it into partial fractions: the residue of a simple pole p is A = [(s − p)·F(s)] at s = p. Final value theorem: f(∞) = lims→0 s·F(s), valid only when all poles of s·F(s) lie in the left half-plane. Initial value theorem: f(0⁺) = lims→∞ s·F(s).
Transform the equation
Y(s) = 400/(s(s + 4)(s + 5))
Partial fractions
A = 400/(4·5) = 20
B = 400/((−4)·1) = −100
C = 400/((−5)·(−1)) = 80
Output
y(t) = 20 − 100·e−4t + 80·e−5t
y(0.3) = 7.731
Answer
y(0.3) = 7.731
3.Block diagrams
Answer: ess = 0.1724
Block-diagram algebra: blocks in series multiply (G₁·G₂), blocks in parallel add (G₁ + G₂), and a loop with forward path G and feedback path H reduces to T = G/(1 + G·H) for negative feedback and G/(1 − G·H) for positive feedback. Reduce inner loops first, then work outwards. The closed-loop poles are the roots of the characteristic equation 1 + G(s)H(s) = 0. For a stable loop, a step input of size A gives the steady-state output A·T(0); with unity feedback the steady-state error to a step is A/(1 + Kp) with Kp = G(0).
Position error constant
Kₚ = G(0) = 12·4/(2·5) = 4.8
Steady-state error
ess = A/(1 + Kₚ) = 1/(1 + 4.8) = 0.1724
Answer
ess = 0.1724
4.Block diagrams
Answer: Kmax = 384
Block-diagram algebra: blocks in series multiply (G₁·G₂), blocks in parallel add (G₁ + G₂), and a loop with forward path G and feedback path H reduces to T = G/(1 + G·H) for negative feedback and G/(1 − G·H) for positive feedback. Reduce inner loops first, then work outwards. The closed-loop poles are the roots of the characteristic equation 1 + G(s)H(s) = 0. For a stable loop, a step input of size A gives the steady-state output A·T(0); with unity feedback the steady-state error to a step is A/(1 + Kp) with Kp = G(0).
Characteristic equation
s³ + 12s² + 32s + K = 0
Routh array
s³ | 1 32
s² | 12 K
s¹ | (12·32 − K)/12
s⁰ | K
Stability limit
All entries of the first column must be positive.
Kmax = 12·32 = 384
Answer
Kmax = 384
5.Step response
Answer: ts = 2.667 s
Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).
Compare with the standard form
The denominator must match s² + 2ζωₙs + ωₙ².
ωₙ² = 52 → ωₙ = 7.211 rad/s
2ζωₙ = 3 → ζ = 3/(2·7.211) = 0.208
Result
ζωₙ = 1.5 → ts ≈ 4/1.5 = 2.667 s
Answer
ts = 2.667 s
6.Step response
Answer: ts = 0.4 s
Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).
For this loop ζωₙ = a/2 whatever K is: raising K adds overshoot but does not shorten the settling time.
7.Stability: Routh–Hurwitz & root locus
Answer: ω = 3.162 rad/s
Routh–Hurwitz criterion: a linear system is stable when every root of its characteristic polynomial lies in the left half of the s-plane. Write the coefficients alternately into the first two rows of the Routh array. Each entry of a new row comes from the two rows above it; for a cubic a₃s³ + a₂s² + a₁s + a₀ the s¹ entry is b₁ = (a₂·a₁ − a₃·a₀)/a₂. The number of sign changes in the first column equals the number of roots in the right half-plane. With a gain K in the coefficients, every first-column entry must stay positive: the gain that makes the s¹ entry zero is the stability limit, and the s² row then gives the frequency of the sustained oscillation.
Routh array
s³ + 7s² + 10s + K = 0
s³: 1, 10
s²: 7, K
s¹: (7·10 − K)/7
s⁰: K
Critical gain
K = 7·10 = 70
Auxiliary equation
At the critical gain the s¹ row is zero; the s² row gives the poles on the imaginary axis.
7s² + 70 = 0 → s = ±j√10
ω = 3.162 rad/s
Answer
ω = 3.162 rad/s
8.Stability: Routh–Hurwitz & root locus
Answer: θd = −63.43 °
Root locus: as the gain K goes from 0 to ∞, the closed-loop poles, the roots of 1 + K·G(s) = 0, move from the open-loop poles to the open-loop zeros or to infinity. A point on the real axis belongs to the locus when the number of real poles and zeros to its right is odd. The n − m branches that go to infinity follow asymptotes at the angles (2q + 1)·180°/(n − m), which start from the centroid σₐ = (Σ poles − Σ zeros)/(n − m). Branches leave or join the real axis where dK/ds = 0. The angle condition ∠G(s) = 180° fixes the shape, and the magnitude condition K = 1/|G(s)| gives the gain at any point of the locus.
Pole locations
s² + 8s + 17 = 0 → s = −4 ± j1
s = −2
Angles from the other poles
∠(−4 + j1 + 2) = atan2(1, -2) = 153.4°
∠(−4 + j1 − (−4 − j1)) = ∠(j2) = 90°
Angle of departure
θd = 180° − 153.4° − 90° = −63.43°
Answer
θd = −63.43°
9.Steady-state error & PID control
Answer: K = 100
Steady-state error: in a unity-feedback loop with open-loop transfer function G(s) the error is E(s) = R(s)/(1 + G(s)), and by the final value theorem ess = lims→0 s·E(s). The system type is the number of poles of G(s) at s = 0. The error constants are Kp = lim G(s), Kv = lim s·G(s) and Ka = lim s²·G(s), all for s → 0. A step of size A gives ess = A/(1 + Kp), a ramp A·t gives A/Kv and a parabola A·t²/2 gives A/Ka. A type-0 loop follows a step with a finite error, a type-1 loop follows it exactly and a ramp with a finite error.
Required velocity constant
Kv = A/ess = 1/0.02 = 50
Gain
K = 2·Kv = 100
Answer
K = 100
A large gain makes this loop very lightly damped: ζ = 0.1. That conflict is why compensators are used.
10.Steady-state error & PID control
Answer: ess = 5
P, PI and PID control: the controller C(s) = Kp + Ki/s + Kd·s acts on the error. A proportional gain makes the loop faster and reduces the error of a type-0 plant, but never removes it. The integral term adds a pole at s = 0: the system type rises by one, and a step is followed without error. The derivative term adds damping. To choose gains, write the closed-loop characteristic polynomial and compare it with s² + 2ζωns + ωn². Then %OS = 100·e−ζπ/√(1−ζ²), tp = π/ωd with ωd = ωn√(1 − ζ²), and ts ≈ 4/(ζωn).
Velocity constant
s·C(s) = 5s + 4 → 4 as s → 0.
Kv = 4·5/20 = 1
Ramp error
ess = 5/1 = 5
Answer
ess = 5
The PI controller removes the step error completely; a ramp is followed with a constant lag.
11.Bode plots & margins
Answer: φ = −71.5 °
Frequency response: substitute s = jω in the transfer function. The magnitude in decibels is 20·log₁₀|H(jω)| and the phase is the sum of the angles of the numerator factors minus those of the denominator factors. A first-order RC or RL filter has its corner (−3 dB) frequency at ωc = 1/(RC) or R/L, and fc = ωc/(2π); a low-pass filter gives |H| = 1/√(1 + (ω/ωc)²) and φ = −atan(ω/ωc). In the asymptotic (straight-line) Bode plot each pole bends the magnitude down by 20 dB/decade at its corner frequency, each zero bends it up by 20 dB/decade, and an integrator 1/s gives −20 dB/decade at all frequencies. Gain crossover ωc: |L(jω)| = 1 (0 dB); phase margin PM = 180° + ∠L(jωc). Phase crossover ω180: ∠L(jω) = −180°; gain margin GM = −20·log₁₀|L(jω180)| dB. The closed loop is stable when both margins are positive.
Corner frequency
ωc = 1/(RC) = 1/(22000·4.7 × 10⁻⁹) = 9671 rad/s
fc = 1539 Hz → f/fc = 4600/1539 = 2.989
Phase
φ = − atan(2.989) = −71.5°
Answer
φ = −71.5°
12.Bode plots & margins
Answer: K = 473.2
Frequency response: substitute s = jω in the transfer function. The magnitude in decibels is 20·log₁₀|H(jω)| and the phase is the sum of the angles of the numerator factors minus those of the denominator factors. A first-order RC or RL filter has its corner (−3 dB) frequency at ωc = 1/(RC) or R/L, and fc = ωc/(2π); a low-pass filter gives |H| = 1/√(1 + (ω/ωc)²) and φ = −atan(ω/ωc). In the asymptotic (straight-line) Bode plot each pole bends the magnitude down by 20 dB/decade at its corner frequency, each zero bends it up by 20 dB/decade, and an integrator 1/s gives −20 dB/decade at all frequencies. Gain crossover ωc: |L(jω)| = 1 (0 dB); phase margin PM = 180° + ∠L(jωc). Phase crossover ω180: ∠L(jω) = −180°; gain margin GM = −20·log₁₀|L(jω180)| dB. The closed loop is stable when both margins are positive.