In the print window, choose “Save as PDF” to keep a copy on your device.
1Formulas and methods
Stability: Routh–Hurwitz & root locus
Stability
all roots of the characteristic polynomial in the left half-plane
Routh array, s¹ entry of a cubic
b1 = (a2a1 − a3a0)/a2
Right half-plane roots
number of sign changes in the first column
Cubic s³ + a₂s² + a₁s + a₀
stable when all a > 0 and a₂·a₁ > a₀
K/(s(s + a)(s + b))
Kmax = ab(a + b), ω = √(ab)
Characteristic equation
1 + K·G(s) = 0
Asymptotes
σa = (Σp − Σz)/(n − m), θ = (2q + 1)·180°/(n − m)
Break-away and break-in points
dK/ds = 0
Magnitude condition
K = 1/|G(s)|
Angle of departure
θd = 180° − Σ∠(from other poles) + Σ∠(from zeros)
Method
Write the closed-loop characteristic polynomial: the denominator of 1 + K·G(s) = 0, multiplied out.
Put the coefficients alternately into the first two rows of the Routh array and build the remaining rows.
Count the sign changes in the first column: each one is a pole in the right half-plane. With K in the array, demand that every first-column entry stays positive.
For a root locus, mark the poles and zeros, the real-axis segments, the asymptotes from the centroid and the break points where dK/ds = 0. Use K = 1/|G(s)| for the gain at a point.
Steady-state error & PID control
System type
number of poles of G(s) at s = 0
Error constants
Kp = lim G(s), Kv = lim s·G(s), Ka = lim s²·G(s) (s → 0)
Step A
ess = A/(1 + Kp)
Ramp A·t
ess = A/Kv
Parabola A·t²/2
ess = A/Ka
PID controller
C(s) = Kp + Ki/s + Kd·s
Second-order target
s² + 2ζωns + ωn²
Overshoot and timing
%OS = 100·e−ζπ/√(1−ζ²), tp = π/ωd, ts ≈ 4/(ζωn)
Method
Count the poles of the open loop C(s)·G(s) at s = 0: that is the system type.
Work out the error constant that matches the input: Kp for a step, Kv for a ramp, Ka for a parabola.
Apply ess = A/(1 + Kp), A/Kv or A/Ka, or solve it for the gain you need.
For a damping or speed specification, write the closed-loop characteristic polynomial and match it with s² + 2ζω_n·s + ω_n².
2Practice problems
1.Laplace transformsMedium
Find f(t) for F(s) = 20/(s(s + 1)(s + 4)) by partial fractions, and evaluate f(1.2).
F(s) = 20/(s(s + 1)(s + 4))t = 1.2 s
f(1.2) =
2.Laplace transformsHard
A system obeys y″ + 8y′ + 12y = 36·u(t), with y(0) = 6 and y′(0) = 0. At t = 0 a step input u(t) = 1 is applied. Use the Laplace transform to find y(0.6).
A plant G(s) = 2/(s + 2) is controlled in a negative feedback loop whose sensor has the gain H = 0.2. Find the time constant τ of the closed loop.
G(s) = 2/(s + 2)H = 0.2
τ = s
4.Block diagramsHard
Reduce the block diagram with G₁ = 11/(s + 4), G₂ = 5/(s + 2), an inner negative feedback H₁ = 4 around G₂ and an outer negative feedback H₂ = 0.25. Find the DC gain T(0) of C(s)/R(s).
G₁ = 11/(s + 4)G₂ = 5/(s + 2)H₁ = 4H₂ = 0.25
T(0) =
5.Step responseMedium
A system has the transfer function G(s) = 92/(s² + 9s + 92) and receives a unit step input. Find the percent overshoot %OS of the step response.
G(s) = 92/(s² + 9s + 92)
%OS = %
6.Step responseHard
A unity negative feedback loop has G(s) = K/(s(s + 16)). Find the gain K that gives a step response with 5 % overshoot.
G(s) = K/(s(s + 16))%OS = 5 %
K =
7.Stability: Routh–Hurwitz & root locusMedium
The loop in the diagram runs with K = 187.5 and L(s) = K/(s(s + 5)(s + 10)). By what factor m can the gain be raised before the closed loop becomes unstable?
L(s) = K/(s(s + 5)(s + 10))K = 187.5
m =
8.Stability: Routh–Hurwitz & root locusHard
The root locus of L(s) = K(s + 10)/(s(s + 7)) leaves the real axis between s = 0 and s = −7, circles round and joins the real axis again to the left of the zero. Find the break-in point si.
L(s) = K(s + 10)/(s(s + 7))
si =
9.Steady-state error & PID controlMedium
The input r(t) = 1 + 5t (a step plus a ramp) is applied to a unity-feedback loop with G(s) = 5(s + 1)/(s(s + 2)(s + 10)). Find the steady-state error ess.
G(s) = 5(s + 1)/(s(s + 2)(s + 10))r(t) = 1 + 5t
ess =
10.Steady-state error & PID controlHard
A proportional controller K = 40 drives the plant G(s) = 2/(s(s + 6)) in a unity-feedback loop. Find the peak time tp of the step response.
G(s) = 2/(s(s + 6))K = 40
tp = s
11.Bode plots & marginsMedium
The RC low-pass filter shown has R = 4.7 kΩ, C = 47 nF. A sinusoidal input of 2.9 kHz is applied. Find the gain |H| = |vout/vin| in dB.
R = 4.7 kΩC = 47 nFf = 2.9 kHz
|H| = dB
12.Bode plots & marginsHard
A unity-feedback loop has the open-loop transfer function L(s) = 70/(s(s + 1)(s + 10)). Find the phase crossover frequency ω180, where ∠L(jω) = −180°.
L(s) = 70/(s(s + 1)(s + 10))
ω180 = rad/s
3Solutions
1.Laplace transforms
Answer: f(1.2) = 3.006
Laplace transform: F(s) = ∫₀∞ f(t)·e−st dt turns derivatives into multiplications by s: ℒ{f′} = sF(s) − f(0), ℒ{f″} = s²F(s) − s·f(0) − f′(0). Standard pairs: 1 ↔ 1/s, e−at ↔ 1/(s + a), t·e−at ↔ 1/(s + a)², sin ωt ↔ ω/(s² + ω²), cos ωt ↔ s/(s² + ω²), and a shift s → s + σ multiplies the time function by e−σt. To invert a rational F(s), split it into partial fractions: the residue of a simple pole p is A = [(s − p)·F(s)] at s = p. Final value theorem: f(∞) = lims→0 s·F(s), valid only when all poles of s·F(s) lie in the left half-plane. Initial value theorem: f(0⁺) = lims→∞ s·F(s).
Partial fractions
F(s) = A/s + B/(s + 1) + C/(s + 4)
A = 20/(1·4) = 5
B = 20/((−1)·3) = −6.667
C = 20/((−4)·(−3)) = 1.667
Inverse transform
f(t) = 5 − 6.667·e−t + 1.667·e−4t
Evaluate
f(1.2) = 5 − 6.667·e−1.2 + 1.667·e−4·1.2 = 3.006
Answer
f(1.2) = 3.006
2.Laplace transforms
Answer: y(0.6) = 4.314
Laplace transform: F(s) = ∫₀∞ f(t)·e−st dt turns derivatives into multiplications by s: ℒ{f′} = sF(s) − f(0), ℒ{f″} = s²F(s) − s·f(0) − f′(0). Standard pairs: 1 ↔ 1/s, e−at ↔ 1/(s + a), t·e−at ↔ 1/(s + a)², sin ωt ↔ ω/(s² + ω²), cos ωt ↔ s/(s² + ω²), and a shift s → s + σ multiplies the time function by e−σt. To invert a rational F(s), split it into partial fractions: the residue of a simple pole p is A = [(s − p)·F(s)] at s = p. Final value theorem: f(∞) = lims→0 s·F(s), valid only when all poles of s·F(s) lie in the left half-plane. Initial value theorem: f(0⁺) = lims→∞ s·F(s).
Transform the equation
(s² + 8s + 12)·Y(s) = 6s + 48 + 36/s
Y(s) = (6s² + 48s + 36)/(s(s + 2)(s + 6))
Partial fractions
A = 36/(2·6) = 3
B = −36/((−2)·4) = 4.5
C = −36/((−6)·(−4)) = −1.5
Result
y(t) = 3 + 4.5·e−2t − 1.5·e−6t
y(0.6) = 4.314
Answer
y(0.6) = 4.314
Check: y(0) = A + B + C = 6.
3.Block diagrams
Answer: τ = 0.4167 s
Block-diagram algebra: blocks in series multiply (G₁·G₂), blocks in parallel add (G₁ + G₂), and a loop with forward path G and feedback path H reduces to T = G/(1 + G·H) for negative feedback and G/(1 − G·H) for positive feedback. Reduce inner loops first, then work outwards. The closed-loop poles are the roots of the characteristic equation 1 + G(s)H(s) = 0. For a stable loop, a step input of size A gives the steady-state output A·T(0); with unity feedback the steady-state error to a step is A/(1 + Kp) with Kp = G(0).
Block-diagram algebra: blocks in series multiply (G₁·G₂), blocks in parallel add (G₁ + G₂), and a loop with forward path G and feedback path H reduces to T = G/(1 + G·H) for negative feedback and G/(1 − G·H) for positive feedback. Reduce inner loops first, then work outwards. The closed-loop poles are the roots of the characteristic equation 1 + G(s)H(s) = 0. For a stable loop, a step input of size A gives the steady-state output A·T(0); with unity feedback the steady-state error to a step is A/(1 + Kp) with Kp = G(0).
Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).
Compare with the standard form
The denominator must match s² + 2ζωₙs + ωₙ².
ωₙ² = 92 → ωₙ = 9.592 rad/s
2ζωₙ = 9 → ζ = 9/(2·9.592) = 0.4692
Result
%OS = 100·e−ζπ/√(1−ζ²) = 100·e−1.669 = 18.84 %
Answer
%OS = 18.84 %
6.Step response
Answer: K = 134.4
Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).
Closed-loop transfer function
T(s) = K/(s² + 16s + K)
Damping ratio from the overshoot
ζ = −ln(0.05)/√(π² + ln²(0.05)) = 0.6901
Gain
ωₙ = 16/(2ζ) = 11.59 rad/s
K = ωₙ² = 134.4
Answer
K = 134.4
7.Stability: Routh–Hurwitz & root locus
Answer: m = 4
Routh–Hurwitz criterion: a linear system is stable when every root of its characteristic polynomial lies in the left half of the s-plane. Write the coefficients alternately into the first two rows of the Routh array. Each entry of a new row comes from the two rows above it; for a cubic a₃s³ + a₂s² + a₁s + a₀ the s¹ entry is b₁ = (a₂·a₁ − a₃·a₀)/a₂. The number of sign changes in the first column equals the number of roots in the right half-plane. With a gain K in the coefficients, every first-column entry must stay positive: the gain that makes the s¹ entry zero is the stability limit, and the s² row then gives the frequency of the sustained oscillation.
Routh array
s³ + 15s² + 50s + K = 0
s³: 1, 50
s²: 15, K
s¹: (15·50 − K)/15
s⁰: K
Largest stable gain
Kmax = 15·50 = 750
Factor
m = 750/187.5 = 4
Answer
m = 4
This factor is the gain margin as a ratio: 12.04 dB.
8.Stability: Routh–Hurwitz & root locus
Answer: si = −15.48
Root locus: as the gain K goes from 0 to ∞, the closed-loop poles, the roots of 1 + K·G(s) = 0, move from the open-loop poles to the open-loop zeros or to infinity. A point on the real axis belongs to the locus when the number of real poles and zeros to its right is odd. The n − m branches that go to infinity follow asymptotes at the angles (2q + 1)·180°/(n − m), which start from the centroid σₐ = (Σ poles − Σ zeros)/(n − m). Branches leave or join the real axis where dK/ds = 0. The angle condition ∠G(s) = 180° fixes the shape, and the magnitude condition K = 1/|G(s)| gives the gain at any point of the locus.
Gain along the real axis
K(s) = −(s² + 7s)/(s + 10)
Stationary points
Differentiate with the quotient rule and set the numerator to zero.
(2s + 7)(s + 10) − (s² + 7s) = s² + 20s + 70 = 0
s = −10 ± √30 = −4.523, −15.48
Break-in point
si = −15.48
Answer
si = −15.48
Between the two break points the locus is a circle centred on the zero, with radius √30 = 5.477.
9.Steady-state error & PID control
Answer: ess = 20
Steady-state error: in a unity-feedback loop with open-loop transfer function G(s) the error is E(s) = R(s)/(1 + G(s)), and by the final value theorem ess = lims→0 s·E(s). The system type is the number of poles of G(s) at s = 0. The error constants are Kp = lim G(s), Kv = lim s·G(s) and Ka = lim s²·G(s), all for s → 0. A step of size A gives ess = A/(1 + Kp), a ramp A·t gives A/Kv and a parabola A·t²/2 gives A/Ka. A type-0 loop follows a step with a finite error, a type-1 loop follows it exactly and a ramp with a finite error.
Velocity constant
Kv = lim s·G(s) = 0.25
Step part
Kp = ∞ → estep = 0
Ramp error
ess = 5/0.25 = 20
Answer
ess = 20
10.Steady-state error & PID control
Answer: tp = 0.3728 s
P, PI and PID control: the controller C(s) = Kp + Ki/s + Kd·s acts on the error. A proportional gain makes the loop faster and reduces the error of a type-0 plant, but never removes it. The integral term adds a pole at s = 0: the system type rises by one, and a step is followed without error. The derivative term adds damping. To choose gains, write the closed-loop characteristic polynomial and compare it with s² + 2ζωns + ωn². Then %OS = 100·e−ζπ/√(1−ζ²), tp = π/ωd with ωd = ωn√(1 − ζ²), and ts ≈ 4/(ζωn).
Characteristic polynomial
s(s + 6) + 40·2 = s² + 6s + 80
ωₙ and ζ
ωₙ = √80 = 8.944 rad/s
ζ = 6/(2·8.944) = 0.3354
Peak time
ωd = 8.944·√(1 − 0.3354²) = 8.426 rad/s
tp = π/8.426 = 0.3728 s
Answer
tp = 0.3728 s
11.Bode plots & margins
Answer: |H| = −12.36 dB
Frequency response: substitute s = jω in the transfer function. The magnitude in decibels is 20·log₁₀|H(jω)| and the phase is the sum of the angles of the numerator factors minus those of the denominator factors. A first-order RC or RL filter has its corner (−3 dB) frequency at ωc = 1/(RC) or R/L, and fc = ωc/(2π); a low-pass filter gives |H| = 1/√(1 + (ω/ωc)²) and φ = −atan(ω/ωc). In the asymptotic (straight-line) Bode plot each pole bends the magnitude down by 20 dB/decade at its corner frequency, each zero bends it up by 20 dB/decade, and an integrator 1/s gives −20 dB/decade at all frequencies. Gain crossover ωc: |L(jω)| = 1 (0 dB); phase margin PM = 180° + ∠L(jωc). Phase crossover ω180: ∠L(jω) = −180°; gain margin GM = −20·log₁₀|L(jω180)| dB. The closed loop is stable when both margins are positive.
Corner frequency
ωc = 1/(RC) = 1/(4700·4.7 × 10⁻⁸) = 4527 rad/s
fc = 720.5 Hz → f/fc = 2900/720.5 = 4.025
Gain
|H| = 1/√(1 + 4.025²) = 0.2411
20·log₁₀(0.2411) = −12.36 dB
Answer
|H| = −12.36 dB
12.Bode plots & margins
Answer: ω180 = 3.162 rad/s
Frequency response: substitute s = jω in the transfer function. The magnitude in decibels is 20·log₁₀|H(jω)| and the phase is the sum of the angles of the numerator factors minus those of the denominator factors. A first-order RC or RL filter has its corner (−3 dB) frequency at ωc = 1/(RC) or R/L, and fc = ωc/(2π); a low-pass filter gives |H| = 1/√(1 + (ω/ωc)²) and φ = −atan(ω/ωc). In the asymptotic (straight-line) Bode plot each pole bends the magnitude down by 20 dB/decade at its corner frequency, each zero bends it up by 20 dB/decade, and an integrator 1/s gives −20 dB/decade at all frequencies. Gain crossover ωc: |L(jω)| = 1 (0 dB); phase margin PM = 180° + ∠L(jωc). Phase crossover ω180: ∠L(jω) = −180°; gain margin GM = −20·log₁₀|L(jω180)| dB. The closed loop is stable when both margins are positive.