1Formulas and methods
Stability: Routh–Hurwitz & root locus
Stability
all roots of the characteristic polynomial in the left half-plane
Routh array, s¹ entry of a cubic
b1 = (a2a1 − a3a0)/a2
Right half-plane roots
number of sign changes in the first column
Cubic s³ + a₂s² + a₁s + a₀
stable when all a > 0 and a₂·a₁ > a₀
K/(s(s + a)(s + b))
Kmax = ab(a + b), ω = √(ab)
Characteristic equation
1 + K·G(s) = 0
Asymptotes
σa = (Σp − Σz)/(n − m), θ = (2q + 1)·180°/(n − m)
Break-away and break-in points
dK/ds = 0
Magnitude condition
K = 1/|G(s)|
Angle of departure
θd = 180° − Σ∠(from other poles) + Σ∠(from zeros)
Method
Write the closed-loop characteristic polynomial: the denominator of 1 + K·G(s) = 0, multiplied out.
Put the coefficients alternately into the first two rows of the Routh array and build the remaining rows.
Count the sign changes in the first column: each one is a pole in the right half-plane. With K in the array, demand that every first-column entry stays positive.
For a root locus, mark the poles and zeros, the real-axis segments, the asymptotes from the centroid and the break points where dK/ds = 0. Use K = 1/|G(s)| for the gain at a point.
Steady-state error & PID control
System type
number of poles of G(s) at s = 0
Error constants
Kp = lim G(s), Kv = lim s·G(s), Ka = lim s²·G(s) (s → 0)
Step A
ess = A/(1 + Kp)
Ramp A·t
ess = A/Kv
Parabola A·t²/2
ess = A/Ka
PID controller
C(s) = Kp + Ki/s + Kd·s
Second-order target
s² + 2ζωns + ωn²
Overshoot and timing
%OS = 100·e−ζπ/√(1−ζ²), tp = π/ωd, ts ≈ 4/(ζωn)
Method
Count the poles of the open loop C(s)·G(s) at s = 0: that is the system type.
Work out the error constant that matches the input: Kp for a step, Kv for a ramp, Ka for a parabola.
Apply ess = A/(1 + Kp), A/Kv or A/Ka, or solve it for the gain you need.
For a damping or speed specification, write the closed-loop characteristic polynomial and match it with s² + 2ζω_n·s + ω_n².
2Practice problems
1.Laplace transformsMedium
Find f(t) for F(s) = 10/(s(s + 4)(s + 6)) by partial fractions, and evaluate f(0.25).
F(s) = 10/(s(s + 4)(s + 6))t = 0.25 s
f(0.25) =
2.Laplace transformsHard
Solve y″ + 8y′ + 12y = 0 with y(0) = −6 and y′(0) = 6 using the Laplace transform, and find y(0.25).
y″ + 8y′ + 12y = 0y(0) = −6y′(0) = 6t = 0.25 s
y(0.25) =
3.Block diagramsMedium
A unity negative feedback loop has G(s) = 7(s + 7)/((s + 5)(s + 6)). A step of size 1 is applied at the reference. Find the steady-state error ess.
G(s) = 7(s + 7)/((s + 5)(s + 6))R = 1
ess =
4.Block diagramsHard
The plant G(s) = 8/(s(s + 4)) is in a negative feedback loop with sensor gain H = 2. The closed-loop poles are complex. Find their real part σ.
G(s) = 8/(s(s + 4))H = 2
σ =
5.Step responseMedium
A system has the transfer function G(s) = 19.5/(s² + 4s + 39) and receives a unit step input. Find the peak time tp of the step response.
G(s) = 19.5/(s² + 4s + 39)
tp = s
6.Step responseHard
A mass m = 2.5 kg hangs on a spring k = 100 N/m with a viscous damper c = 13 N·s/m (m·x″ + c·x′ + k·x = F). At rest in equilibrium, a constant force F = 5 N is suddenly applied. Find the time tp at which the displacement is largest.
m = 2.5 kgk = 100 N/mc = 13 N·s/mF = 5 N
tp = s
7.Stability: Routh–Hurwitz & root locusMedium
The loop in the diagram runs with K = 96 and L(s) = K/(s(s + 4)(s + 6)). By what factor m can the gain be raised before the closed loop becomes unstable?
L(s) = K/(s(s + 4)(s + 6))K = 96
m =
8.Stability: Routh–Hurwitz & root locusHard
For L(s) = K/((s + 8)(s² + 8s + 32)), find the angle of departure θd of the root locus from the complex pole in the upper half-plane, measured from the positive real axis.
L(s) = K/((s + 8)(s² + 8s + 32))
θd = °
9.Steady-state error & PID controlMedium
The parabolic input r(t) = 5·t²/2 is applied to a unity-feedback loop with G(s) = 4(s + 1)/(s²(s + 4)). Find the steady-state error ess.
G(s) = 4(s + 1)/(s²(s + 4))r(t) = 5·t²/2
ess =
10.Steady-state error & PID controlHard
A proportional controller K = 50 drives the plant G(s) = 1/(s(s + 10)) in a unity-feedback loop. Find the peak time tp of the step response.
G(s) = 1/(s(s + 10))K = 50
tp = s
11.Bode plots & marginsMedium
The RC high-pass filter shown has R = 22 kΩ, C = 2.2 nF. A sinusoidal input of 820 Hz is applied. Find the gain |H| = |vout/vin| in dB.
R = 22 kΩC = 2.2 nFf = 820 Hz
|H| = dB
12.Bode plots & marginsHard
A unity-feedback loop has the open-loop transfer function L(s) = 78/(s(s + 1)(s + 10)). Find the phase crossover frequency ω180, where ∠L(jω) = −180°.
L(s) = 78/(s(s + 1)(s + 10))
ω180 = rad/s
3Solutions
1.Laplace transforms
Answer: f(0.25) = 0.1428
Laplace transform: F(s) = ∫₀∞ f(t)·e−st dt turns derivatives into multiplications by s: ℒ{f′} = sF(s) − f(0), ℒ{f″} = s²F(s) − s·f(0) − f′(0). Standard pairs: 1 ↔ 1/s, e−at ↔ 1/(s + a), t·e−at ↔ 1/(s + a)², sin ωt ↔ ω/(s² + ω²), cos ωt ↔ s/(s² + ω²), and a shift s → s + σ multiplies the time function by e−σt. To invert a rational F(s), split it into partial fractions: the residue of a simple pole p is A = [(s − p)·F(s)] at s = p. Final value theorem: f(∞) = lims→0 s·F(s), valid only when all poles of s·F(s) lie in the left half-plane. Initial value theorem: f(0⁺) = lims→∞ s·F(s).
Laplace transform: F(s) = ∫₀∞ f(t)·e−st dt turns derivatives into multiplications by s: ℒ{f′} = sF(s) − f(0), ℒ{f″} = s²F(s) − s·f(0) − f′(0). Standard pairs: 1 ↔ 1/s, e−at ↔ 1/(s + a), t·e−at ↔ 1/(s + a)², sin ωt ↔ ω/(s² + ω²), cos ωt ↔ s/(s² + ω²), and a shift s → s + σ multiplies the time function by e−σt. To invert a rational F(s), split it into partial fractions: the residue of a simple pole p is A = [(s − p)·F(s)] at s = p. Final value theorem: f(∞) = lims→0 s·F(s), valid only when all poles of s·F(s) lie in the left half-plane. Initial value theorem: f(0⁺) = lims→∞ s·F(s).
Transform the equation
s²Y − (−6)s − 6 + 8(sY − (−6)) + 12Y = 0
Y(s) = (−6s − 42)/((s + 2)(s + 6))
Partial fractions
A = −30/4 = −7.5
B = −6/(−4) = 1.5
Result
y(t) = −7.5·e−2t + 1.5·e−6t
y(0.25) = −4.214
Answer
y(0.25) = −4.214
Check: y(0) = A + B = −6.
3.Block diagrams
Answer: ess = 0.3797
Block-diagram algebra: blocks in series multiply (G₁·G₂), blocks in parallel add (G₁ + G₂), and a loop with forward path G and feedback path H reduces to T = G/(1 + G·H) for negative feedback and G/(1 − G·H) for positive feedback. Reduce inner loops first, then work outwards. The closed-loop poles are the roots of the characteristic equation 1 + G(s)H(s) = 0. For a stable loop, a step input of size A gives the steady-state output A·T(0); with unity feedback the steady-state error to a step is A/(1 + Kp) with Kp = G(0).
Position error constant
Kₚ = G(0) = 7·7/(5·6) = 1.633
Steady-state error
ess = A/(1 + Kₚ) = 1/(1 + 1.633) = 0.3797
Answer
ess = 0.3797
4.Block diagrams
Answer: σ = −2
Block-diagram algebra: blocks in series multiply (G₁·G₂), blocks in parallel add (G₁ + G₂), and a loop with forward path G and feedback path H reduces to T = G/(1 + G·H) for negative feedback and G/(1 − G·H) for positive feedback. Reduce inner loops first, then work outwards. The closed-loop poles are the roots of the characteristic equation 1 + G(s)H(s) = 0. For a stable loop, a step input of size A gives the steady-state output A·T(0); with unity feedback the steady-state error to a step is A/(1 + Kp) with Kp = G(0).
Characteristic equation
s(s + 4) + 8·2 = 0 → s² + 4s + 16 = 0
Roots
s = −2 ± j·√(16 − 4) = −2 ± j3.464
σ = −2
Answer
σ = −2
5.Step response
Answer: tp = 0.531 s
Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).
Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).
Natural frequency and damping ratio
ωₙ = √(k/m) = √(100/2.5) = 6.325 rad/s
ζ = c/(2√(km)) = 13/(2·√(100·2.5)) = 0.4111
Result
ωd = 5.765 rad/s
tp = π/ωd = 0.5449 s
Answer
tp = 0.5449 s
7.Stability: Routh–Hurwitz & root locus
Answer: m = 2.5
Routh–Hurwitz criterion: a linear system is stable when every root of its characteristic polynomial lies in the left half of the s-plane. Write the coefficients alternately into the first two rows of the Routh array. Each entry of a new row comes from the two rows above it; for a cubic a₃s³ + a₂s² + a₁s + a₀ the s¹ entry is b₁ = (a₂·a₁ − a₃·a₀)/a₂. The number of sign changes in the first column equals the number of roots in the right half-plane. With a gain K in the coefficients, every first-column entry must stay positive: the gain that makes the s¹ entry zero is the stability limit, and the s² row then gives the frequency of the sustained oscillation.
Routh array
s³ + 10s² + 24s + K = 0
s³: 1, 24
s²: 10, K
s¹: (10·24 − K)/10
s⁰: K
Largest stable gain
Kmax = 10·24 = 240
Factor
m = 240/96 = 2.5
Answer
m = 2.5
This factor is the gain margin as a ratio: 7.959 dB.
8.Stability: Routh–Hurwitz & root locus
Answer: θd = 45 °
Root locus: as the gain K goes from 0 to ∞, the closed-loop poles, the roots of 1 + K·G(s) = 0, move from the open-loop poles to the open-loop zeros or to infinity. A point on the real axis belongs to the locus when the number of real poles and zeros to its right is odd. The n − m branches that go to infinity follow asymptotes at the angles (2q + 1)·180°/(n − m), which start from the centroid σₐ = (Σ poles − Σ zeros)/(n − m). Branches leave or join the real axis where dK/ds = 0. The angle condition ∠G(s) = 180° fixes the shape, and the magnitude condition K = 1/|G(s)| gives the gain at any point of the locus.
Pole locations
s² + 8s + 32 = 0 → s = −4 ± j4
s = −8
Angles from the other poles
∠(−4 + j4 + 8) = atan2(4, 4) = 45°
∠(−4 + j4 − (−4 − j4)) = ∠(j8) = 90°
Angle of departure
θd = 180° − 45° − 90° = 45°
Answer
θd = 45°
9.Steady-state error & PID control
Answer: ess = 5
Steady-state error: in a unity-feedback loop with open-loop transfer function G(s) the error is E(s) = R(s)/(1 + G(s)), and by the final value theorem ess = lims→0 s·E(s). The system type is the number of poles of G(s) at s = 0. The error constants are Kp = lim G(s), Kv = lim s·G(s) and Ka = lim s²·G(s), all for s → 0. A step of size A gives ess = A/(1 + Kp), a ramp A·t gives A/Kv and a parabola A·t²/2 gives A/Ka. A type-0 loop follows a step with a finite error, a type-1 loop follows it exactly and a ramp with a finite error.
Acceleration constant
Ka = 4·1/4 = 1
Parabola error
ess = 5/1 = 5
Answer
ess = 5
10.Steady-state error & PID control
Answer: tp = 0.6283 s
P, PI and PID control: the controller C(s) = Kp + Ki/s + Kd·s acts on the error. A proportional gain makes the loop faster and reduces the error of a type-0 plant, but never removes it. The integral term adds a pole at s = 0: the system type rises by one, and a step is followed without error. The derivative term adds damping. To choose gains, write the closed-loop characteristic polynomial and compare it with s² + 2ζωns + ωn². Then %OS = 100·e−ζπ/√(1−ζ²), tp = π/ωd with ωd = ωn√(1 − ζ²), and ts ≈ 4/(ζωn).
Characteristic polynomial
s(s + 10) + 50·1 = s² + 10s + 50
ωₙ and ζ
ωₙ = √50 = 7.071 rad/s
ζ = 10/(2·7.071) = 0.7071
Peak time
ωd = 7.071·√(1 − 0.7071²) = 5 rad/s
tp = π/5 = 0.6283 s
Answer
tp = 0.6283 s
11.Bode plots & margins
Answer: |H| = −12.33 dB
Frequency response: substitute s = jω in the transfer function. The magnitude in decibels is 20·log₁₀|H(jω)| and the phase is the sum of the angles of the numerator factors minus those of the denominator factors. A first-order RC or RL filter has its corner (−3 dB) frequency at ωc = 1/(RC) or R/L, and fc = ωc/(2π); a low-pass filter gives |H| = 1/√(1 + (ω/ωc)²) and φ = −atan(ω/ωc). In the asymptotic (straight-line) Bode plot each pole bends the magnitude down by 20 dB/decade at its corner frequency, each zero bends it up by 20 dB/decade, and an integrator 1/s gives −20 dB/decade at all frequencies. Gain crossover ωc: |L(jω)| = 1 (0 dB); phase margin PM = 180° + ∠L(jωc). Phase crossover ω180: ∠L(jω) = −180°; gain margin GM = −20·log₁₀|L(jω180)| dB. The closed loop is stable when both margins are positive.
Corner frequency
ωc = 1/(RC) = 1/(22000·2.2 × 10⁻⁹) = 20661 rad/s
fc = 3288 Hz → f/fc = 820/3288 = 0.2494
Gain
|H| = 0.2494/√(1 + 0.2494²) = 0.242
20·log₁₀(0.242) = −12.33 dB
Answer
|H| = −12.33 dB
12.Bode plots & margins
Answer: ω180 = 3.162 rad/s
Frequency response: substitute s = jω in the transfer function. The magnitude in decibels is 20·log₁₀|H(jω)| and the phase is the sum of the angles of the numerator factors minus those of the denominator factors. A first-order RC or RL filter has its corner (−3 dB) frequency at ωc = 1/(RC) or R/L, and fc = ωc/(2π); a low-pass filter gives |H| = 1/√(1 + (ω/ωc)²) and φ = −atan(ω/ωc). In the asymptotic (straight-line) Bode plot each pole bends the magnitude down by 20 dB/decade at its corner frequency, each zero bends it up by 20 dB/decade, and an integrator 1/s gives −20 dB/decade at all frequencies. Gain crossover ωc: |L(jω)| = 1 (0 dB); phase margin PM = 180° + ∠L(jωc). Phase crossover ω180: ∠L(jω) = −180°; gain margin GM = −20·log₁₀|L(jω180)| dB. The closed loop is stable when both margins are positive.