In the print window, choose “Save as PDF” to keep a copy on your device.
1Formulas and methods
Stability: Routh–Hurwitz & root locus
Stability
all roots of the characteristic polynomial in the left half-plane
Routh array, s¹ entry of a cubic
b1 = (a2a1 − a3a0)/a2
Right half-plane roots
number of sign changes in the first column
Cubic s³ + a₂s² + a₁s + a₀
stable when all a > 0 and a₂·a₁ > a₀
K/(s(s + a)(s + b))
Kmax = ab(a + b), ω = √(ab)
Characteristic equation
1 + K·G(s) = 0
Asymptotes
σa = (Σp − Σz)/(n − m), θ = (2q + 1)·180°/(n − m)
Break-away and break-in points
dK/ds = 0
Magnitude condition
K = 1/|G(s)|
Angle of departure
θd = 180° − Σ∠(from other poles) + Σ∠(from zeros)
Method
Write the closed-loop characteristic polynomial: the denominator of 1 + K·G(s) = 0, multiplied out.
Put the coefficients alternately into the first two rows of the Routh array and build the remaining rows.
Count the sign changes in the first column: each one is a pole in the right half-plane. With K in the array, demand that every first-column entry stays positive.
For a root locus, mark the poles and zeros, the real-axis segments, the asymptotes from the centroid and the break points where dK/ds = 0. Use K = 1/|G(s)| for the gain at a point.
Steady-state error & PID control
System type
number of poles of G(s) at s = 0
Error constants
Kp = lim G(s), Kv = lim s·G(s), Ka = lim s²·G(s) (s → 0)
Step A
ess = A/(1 + Kp)
Ramp A·t
ess = A/Kv
Parabola A·t²/2
ess = A/Ka
PID controller
C(s) = Kp + Ki/s + Kd·s
Second-order target
s² + 2ζωns + ωn²
Overshoot and timing
%OS = 100·e−ζπ/√(1−ζ²), tp = π/ωd, ts ≈ 4/(ζωn)
Method
Count the poles of the open loop C(s)·G(s) at s = 0: that is the system type.
Work out the error constant that matches the input: Kp for a step, Kv for a ramp, Ka for a parabola.
Apply ess = A/(1 + Kp), A/Kv or A/Ka, or solve it for the gain you need.
For a damping or speed specification, write the closed-loop characteristic polynomial and match it with s² + 2ζω_n·s + ω_n².
2Practice problems
1.Laplace transformsMedium
Find f(t) for F(s) = (4s + 37)/(s² + 4s + 13) by completing the square, and evaluate f(0.1).
F(s) = (4s + 37)/(s² + 4s + 13)t = 0.1 s
f(0.1) =
2.Laplace transformsHard
A system obeys y″ + 3y′ + 2y = 6·u(t). It starts at rest (y(0) = 0, y′(0) = 0) and the input is a step u(t) = 1 for t ≥ 0. Use the Laplace transform to find the output y(0.75).
A unity negative feedback loop has G(s) = 1(s + 3)/((s + 1)(s + 2)). A step of size 10 is applied at the reference. Find the steady-state error ess.
G(s) = 1(s + 3)/((s + 1)(s + 2))R = 10
ess =
4.Block diagramsHard
Reduce the block diagram with G₁ = 6/(s + 3), G₂ = 4/(s + 4), an inner negative feedback H₁ = 2 around G₂ and an outer negative feedback H₂ = 1. Find the DC gain T(0) of C(s)/R(s).
G₁ = 6/(s + 3)G₂ = 4/(s + 4)H₁ = 2H₂ = 1
T(0) =
5.Step responseMedium
A system has the transfer function G(s) = 25/(s² + 3s + 50) and receives a unit step input. Find the 2 % settling time ts of the step response, using ts ≈ 4/(ζωₙ).
G(s) = 25/(s² + 3s + 50)
ts = s
6.Step responseHard
A mass m = 10 kg hangs on a spring k = 100 N/m with a viscous damper c = 19 N·s/m (m·x″ + c·x′ + k·x = F). At rest in equilibrium, a constant force F = 10 N is suddenly applied. Find the damping ratio ζ.
m = 10 kgk = 100 N/mc = 19 N·s/mF = 10 N
ζ =
7.Stability: Routh–Hurwitz & root locusMedium
A unity-feedback loop has L(s) = K/((s + 2)(s + 3)(s + 4)), with K > 0. Find the largest gain Kmax for which the closed loop is stable.
L(s) = K/((s + 2)(s + 3)(s + 4))
Kmax =
8.Stability: Routh–Hurwitz & root locusHard
The root locus of L(s) = K/(s(s + 10)) is shown. Find the gain K for which the closed-loop poles have the damping ratio ζ = 0.6.
L(s) = K/(s(s + 10))ζ = 0.6
K =
9.Steady-state error & PID controlMedium
The parabolic input r(t) = 0.5·t²/2 is applied to a unity-feedback loop with G(s) = 5(s + 4)/(s²(s + 10)). Find the steady-state error ess.
G(s) = 5(s + 4)/(s²(s + 10))r(t) = 0.5·t²/2
ess =
10.Steady-state error & PID controlHard
A PI controller C(s) = 5 + 10/s drives the plant G(s) = 10/((s + 1)(s + 4)) in a unity-feedback loop. Find the steady-state error ess for the ramp input r(t) = 1t.
In the series RLC band-pass filter shown the output is taken across R = 5 Ω, with L = 100 mH and C = 2.2 µF. Find the centre (resonant) frequency f0 in Hz.
R = 5 ΩL = 100 mHC = 2.2 µF
f0 = Hz
12.Bode plots & marginsHard
A unity-feedback loop has the open-loop transfer function L(s) = 7/(s(s + 1)). Find the gain crossover frequency ωc, where |L(jω)| = 1.
L(s) = 7/(s(s + 1))
ωc = rad/s
3Solutions
1.Laplace transforms
Answer: f(0.1) = 5.468
Laplace transform: F(s) = ∫₀∞ f(t)·e−st dt turns derivatives into multiplications by s: ℒ{f′} = sF(s) − f(0), ℒ{f″} = s²F(s) − s·f(0) − f′(0). Standard pairs: 1 ↔ 1/s, e−at ↔ 1/(s + a), t·e−at ↔ 1/(s + a)², sin ωt ↔ ω/(s² + ω²), cos ωt ↔ s/(s² + ω²), and a shift s → s + σ multiplies the time function by e−σt. To invert a rational F(s), split it into partial fractions: the residue of a simple pole p is A = [(s − p)·F(s)] at s = p. Final value theorem: f(∞) = lims→0 s·F(s), valid only when all poles of s·F(s) lie in the left half-plane. Initial value theorem: f(0⁺) = lims→∞ s·F(s).
Laplace transform: F(s) = ∫₀∞ f(t)·e−st dt turns derivatives into multiplications by s: ℒ{f′} = sF(s) − f(0), ℒ{f″} = s²F(s) − s·f(0) − f′(0). Standard pairs: 1 ↔ 1/s, e−at ↔ 1/(s + a), t·e−at ↔ 1/(s + a)², sin ωt ↔ ω/(s² + ω²), cos ωt ↔ s/(s² + ω²), and a shift s → s + σ multiplies the time function by e−σt. To invert a rational F(s), split it into partial fractions: the residue of a simple pole p is A = [(s − p)·F(s)] at s = p. Final value theorem: f(∞) = lims→0 s·F(s), valid only when all poles of s·F(s) lie in the left half-plane. Initial value theorem: f(0⁺) = lims→∞ s·F(s).
Transform the equation
Y(s) = 6/(s(s + 1)(s + 2))
Partial fractions
A = 6/(1·2) = 3
B = 6/((−1)·1) = −6
C = 6/((−2)·(−1)) = 3
Output
y(t) = 3 − 6·e−t + 3·e−2t
y(0.75) = 0.8352
Answer
y(0.75) = 0.8352
3.Block diagrams
Answer: ess = 4
Block-diagram algebra: blocks in series multiply (G₁·G₂), blocks in parallel add (G₁ + G₂), and a loop with forward path G and feedback path H reduces to T = G/(1 + G·H) for negative feedback and G/(1 − G·H) for positive feedback. Reduce inner loops first, then work outwards. The closed-loop poles are the roots of the characteristic equation 1 + G(s)H(s) = 0. For a stable loop, a step input of size A gives the steady-state output A·T(0); with unity feedback the steady-state error to a step is A/(1 + Kp) with Kp = G(0).
Position error constant
Kₚ = G(0) = 1·3/(1·2) = 1.5
Steady-state error
ess = A/(1 + Kₚ) = 10/(1 + 1.5) = 4
Answer
ess = 4
4.Block diagrams
Answer: T(0) = 0.4
Block-diagram algebra: blocks in series multiply (G₁·G₂), blocks in parallel add (G₁ + G₂), and a loop with forward path G and feedback path H reduces to T = G/(1 + G·H) for negative feedback and G/(1 − G·H) for positive feedback. Reduce inner loops first, then work outwards. The closed-loop poles are the roots of the characteristic equation 1 + G(s)H(s) = 0. For a stable loop, a step input of size A gives the steady-state output A·T(0); with unity feedback the steady-state error to a step is A/(1 + Kp) with Kp = G(0).
Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).
Compare with the standard form
The denominator must match s² + 2ζωₙs + ωₙ².
ωₙ² = 50 → ωₙ = 7.071 rad/s
2ζωₙ = 3 → ζ = 3/(2·7.071) = 0.2121
Result
ζωₙ = 1.5 → ts ≈ 4/1.5 = 2.667 s
Answer
ts = 2.667 s
6.Step response
Answer: ζ = 0.3004
Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).
Natural frequency and damping ratio
ωₙ = √(k/m) = √(100/10) = 3.162 rad/s
ζ = c/(2√(km)) = 19/(2·√(100·10)) = 0.3004
Result
ζ = 0.3004
Answer
ζ = 0.3004
7.Stability: Routh–Hurwitz & root locus
Answer: Kmax = 210
Routh–Hurwitz criterion: a linear system is stable when every root of its characteristic polynomial lies in the left half of the s-plane. Write the coefficients alternately into the first two rows of the Routh array. Each entry of a new row comes from the two rows above it; for a cubic a₃s³ + a₂s² + a₁s + a₀ the s¹ entry is b₁ = (a₂·a₁ − a₃·a₀)/a₂. The number of sign changes in the first column equals the number of roots in the right half-plane. With a gain K in the coefficients, every first-column entry must stay positive: the gain that makes the s¹ entry zero is the stability limit, and the s² row then gives the frequency of the sustained oscillation.
Characteristic polynomial
s³ + 9s² + 26s + 24 + K = 0
Routh array
s³: 1, 26
s²: 9, 24 + K
s¹: (9·26 − 24 − K)/9
s⁰: 24 + K
Condition
The s¹ entry must stay positive.
K < 9·26 − 24 = 210
Answer
Kmax = 210
At the limit the loop oscillates at ω = √26 = 5.099 rad/s.
8.Stability: Routh–Hurwitz & root locus
Answer: K = 69.44
Root locus: as the gain K goes from 0 to ∞, the closed-loop poles, the roots of 1 + K·G(s) = 0, move from the open-loop poles to the open-loop zeros or to infinity. A point on the real axis belongs to the locus when the number of real poles and zeros to its right is odd. The n − m branches that go to infinity follow asymptotes at the angles (2q + 1)·180°/(n − m), which start from the centroid σₐ = (Σ poles − Σ zeros)/(n − m). Branches leave or join the real axis where dK/ds = 0. The angle condition ∠G(s) = 180° fixes the shape, and the magnitude condition K = 1/|G(s)| gives the gain at any point of the locus.
Compare with the standard form
s² + 10s + K = s² + 2ζωₙs + ωₙ²
2·0.6·ωₙ = 10 → ωₙ = 8.333 rad/s
Gain
K = ωₙ² = 8.333² = 69.44
Answer
K = 69.44
The closed-loop poles sit where the ζ line crosses the vertical branch at s = −5.
9.Steady-state error & PID control
Answer: ess = 0.25
Steady-state error: in a unity-feedback loop with open-loop transfer function G(s) the error is E(s) = R(s)/(1 + G(s)), and by the final value theorem ess = lims→0 s·E(s). The system type is the number of poles of G(s) at s = 0. The error constants are Kp = lim G(s), Kv = lim s·G(s) and Ka = lim s²·G(s), all for s → 0. A step of size A gives ess = A/(1 + Kp), a ramp A·t gives A/Kv and a parabola A·t²/2 gives A/Ka. A type-0 loop follows a step with a finite error, a type-1 loop follows it exactly and a ramp with a finite error.
Acceleration constant
Ka = 5·4/10 = 2
Parabola error
ess = 0.5/2 = 0.25
Answer
ess = 0.25
10.Steady-state error & PID control
Answer: ess = 0.04
P, PI and PID control: the controller C(s) = Kp + Ki/s + Kd·s acts on the error. A proportional gain makes the loop faster and reduces the error of a type-0 plant, but never removes it. The integral term adds a pole at s = 0: the system type rises by one, and a step is followed without error. The derivative term adds damping. To choose gains, write the closed-loop characteristic polynomial and compare it with s² + 2ζωns + ωn². Then %OS = 100·e−ζπ/√(1−ζ²), tp = π/ωd with ωd = ωn√(1 − ζ²), and ts ≈ 4/(ζωn).
Velocity constant
s·C(s) = 5s + 10 → 10 as s → 0.
Kv = 10·10/4 = 25
Ramp error
ess = 1/25 = 0.04
Answer
ess = 0.04
The PI controller removes the step error completely; a ramp is followed with a constant lag.
11.Bode plots & margins
Answer: f0 = 339.3 Hz
Frequency response: substitute s = jω in the transfer function. The magnitude in decibels is 20·log₁₀|H(jω)| and the phase is the sum of the angles of the numerator factors minus those of the denominator factors. A first-order RC or RL filter has its corner (−3 dB) frequency at ωc = 1/(RC) or R/L, and fc = ωc/(2π); a low-pass filter gives |H| = 1/√(1 + (ω/ωc)²) and φ = −atan(ω/ωc). In the asymptotic (straight-line) Bode plot each pole bends the magnitude down by 20 dB/decade at its corner frequency, each zero bends it up by 20 dB/decade, and an integrator 1/s gives −20 dB/decade at all frequencies. Gain crossover ωc: |L(jω)| = 1 (0 dB); phase margin PM = 180° + ∠L(jωc). Phase crossover ω180: ∠L(jω) = −180°; gain margin GM = −20·log₁₀|L(jω180)| dB. The closed loop is stable when both margins are positive.
Resonant frequency
ω₀ = 1/√(LC) = 1/√(0.1·2.2 × 10⁻⁶) = 2132 rad/s
f₀ = ω₀/(2π) = 339.3 Hz
Answer
f0 = 339.3 Hz
12.Bode plots & margins
Answer: ωc = 2.553 rad/s
Frequency response: substitute s = jω in the transfer function. The magnitude in decibels is 20·log₁₀|H(jω)| and the phase is the sum of the angles of the numerator factors minus those of the denominator factors. A first-order RC or RL filter has its corner (−3 dB) frequency at ωc = 1/(RC) or R/L, and fc = ωc/(2π); a low-pass filter gives |H| = 1/√(1 + (ω/ωc)²) and φ = −atan(ω/ωc). In the asymptotic (straight-line) Bode plot each pole bends the magnitude down by 20 dB/decade at its corner frequency, each zero bends it up by 20 dB/decade, and an integrator 1/s gives −20 dB/decade at all frequencies. Gain crossover ωc: |L(jω)| = 1 (0 dB); phase margin PM = 180° + ∠L(jωc). Phase crossover ω180: ∠L(jω) = −180°; gain margin GM = −20·log₁₀|L(jω180)| dB. The closed loop is stable when both margins are positive.