Control Engineering 1: cram pack

Formula sheets, the key method steps for every topic and 12 practice problems, with full solutions at the back.

New problemsBack to the course

In the print window, choose “Save as PDF” to keep a copy on your device.

1Formulas and methods

Stability: Routh–Hurwitz & root locus

Stability
all roots of the characteristic polynomial in the left half-plane
Routh array, s¹ entry of a cubic
b1 = (a2a1 − a3a0)/a2
Right half-plane roots
number of sign changes in the first column
Cubic s³ + a₂s² + a₁s + a₀
stable when all a > 0 and a₂·a₁ > a₀
K/(s(s + a)(s + b))
Kmax = ab(a + b), ω = √(ab)
Characteristic equation
1 + K·G(s) = 0
Asymptotes
σa = (Σp − Σz)/(n − m), θ = (2q + 1)·180°/(n − m)
Break-away and break-in points
dK/ds = 0
Magnitude condition
K = 1/|G(s)|
Angle of departure
θd = 180° − Σ∠(from other poles) + Σ∠(from zeros)

Method

  1. Write the closed-loop characteristic polynomial: the denominator of 1 + K·G(s) = 0, multiplied out.
  2. Put the coefficients alternately into the first two rows of the Routh array and build the remaining rows.
  3. Count the sign changes in the first column: each one is a pole in the right half-plane. With K in the array, demand that every first-column entry stays positive.
  4. For a root locus, mark the poles and zeros, the real-axis segments, the asymptotes from the centroid and the break points where dK/ds = 0. Use K = 1/|G(s)| for the gain at a point.

Steady-state error & PID control

System type
number of poles of G(s) at s = 0
Error constants
Kp = lim G(s), Kv = lim s·G(s), Ka = lim s²·G(s) (s → 0)
Step A
ess = A/(1 + Kp)
Ramp A·t
ess = A/Kv
Parabola A·t²/2
ess = A/Ka
PID controller
C(s) = Kp + Ki/s + Kd·s
Second-order target
s² + 2ζωns + ωn²
Overshoot and timing
%OS = 100·e−ζπ/√(1−ζ²), tp = π/ωd, ts ≈ 4/(ζωn)

Method

  1. Count the poles of the open loop C(s)·G(s) at s = 0: that is the system type.
  2. Work out the error constant that matches the input: Kp for a step, Kv for a ramp, Ka for a parabola.
  3. Apply ess = A/(1 + Kp), A/Kv or A/Ka, or solve it for the gain you need.
  4. For a damping or speed specification, write the closed-loop characteristic polynomial and match it with s² + 2ζω_n·s + ω_n².

2Practice problems

1.Laplace transformsMedium
t (s)f(t)t = 0.8f(0.8) = ?

Find f(t) for F(s) = (5s + 1)/(s² + 4s + 4) and evaluate f(0.8).

F(s) = (5s + 1)/(s² + 4s + 4)t = 0.8 s
f(0.8) =
2.Laplace transformsHard
t (s)y(t)t = 0.1y(0.1) = ?

A system obeys y″ + 11y′ + 30y = 150·u(t). It starts at rest (y(0) = 0, y′(0) = 0) and the input is a step u(t) = 10 for t ≥ 0. Use the Laplace transform to find the output y(0.1).

y″ + 11y′ + 30y = 150·u(t)u(t) = 10y(0) = 0, y′(0) = 0t = 0.1 s
y(0.1) =
3.Block diagramsMedium
R(s)+26s(s + 6)G(s)C(s)−

A unity negative feedback loop has G(s) = 26/(s(s + 6)). The reference is a ramp r(t) = 10·t. Find the steady-state error ess.

G(s) = 26/(s(s + 6))r(t) = 10·t
ess =
4.Block diagramsHard
R(s)+60s(s + 9)G(s)C(s)0.5H−

The plant G(s) = 60/(s(s + 9)) is in a negative feedback loop with sensor gain H = 0.5. The closed-loop poles are complex. Find their imaginary part ωd (the positive value), in rad/s.

G(s) = 60/(s(s + 9))H = 0.5
ωd = rad/s
5.Step responseMedium
t (s)y(t)3

A system has the transfer function G(s) = 180/(s² + 7s + 60) and receives a unit step input. Find the natural frequency ωn in rad/s.

G(s) = 180/(s² + 7s + 60)
ωn = rad/s
6.Step responseHard
+−12 VR = 21 ΩL = 20 mHC = 47 µFvC​

A series RLC circuit with R = 21 Ω, L = 20 mH and C = 47 µF is connected to a 12 V step at t = 0. The capacitor is uncharged and no current flows before the step. Find the percent overshoot %OS of the capacitor voltage.

R = 21 ΩL = 20 mHC = 47 µFV = 12 V
%OS = %
7.Stability: Routh–Hurwitz & root locusMedium
R(s)+K1(s + 2)(s + 4)(s + 5)C(s)−

A unity-feedback loop has L(s) = K/((s + 2)(s + 4)(s + 5)), with K > 0. Find the largest gain Kmax for which the closed loop is stable.

L(s) = K/((s + 2)(s + 4)(s + 5))
Kmax =
8.Stability: Routh–Hurwitz & root locusHard
ReIm−1−2−3−4−5−6−7−81j1j2sb​

The root locus of L(s) = K/((s + 1)(s + 7)) is shown. Find the gain K at the break-away point sb, where the two closed-loop poles meet on the real axis.

L(s) = K/((s + 1)(s + 7))
K =
9.Steady-state error & PID controlMedium
R(s)+K(s + 2)(s + 5)C(s)−

A unity-feedback loop has G(s) = K/((s + 2)(s + 5)). Find the gain K that gives a steady-state error of 25 % for a step input.

G(s) = K/((s + 2)(s + 5))ess = 25 %
K =
10.Steady-state error & PID controlHard
R(s)+K = 54s(s + 5)C(s)−

A proportional controller K = 5 drives the plant G(s) = 4/(s(s + 5)) in a unity-feedback loop. Find the peak time tp of the step response.

G(s) = 4/(s(s + 5))K = 5
tp = s
11.Bode plots & marginsMedium
vin​R = 1 kΩC = 10 nFvout​

The RC low-pass filter shown has R = 1 kΩ, C = 10 nF. A sinusoidal input of 3.2 kHz is applied. Find the phase shift φ of vout relative to vin, in degrees.

R = 1 kΩC = 10 nFf = 3.2 kHz
φ = °
12.Bode plots & marginsHard
|H| (dB)0.10.1111010100100−80−60−40−2002040ω (rad/s)φ (°)ω (rad/s)−180−135−90−450ωc​ = ?

A unity-feedback loop has the open-loop transfer function L(s) = 2.5/(s(s + 1)). Find the gain crossover frequency ωc, where |L(jω)| = 1.

L(s) = 2.5/(s(s + 1))
ωc = rad/s

3Solutions

1.Laplace transforms

Answer: f(0.8) = −0.4442

Laplace transform: F(s) = ∫₀∞ f(t)·e−st dt turns derivatives into multiplications by s: ℒ{f′} = sF(s) − f(0), ℒ{f″} = s²F(s) − s·f(0) − f′(0). Standard pairs: 1 ↔ 1/s, e−at ↔ 1/(s + a), t·e−at ↔ 1/(s + a)², sin ωt ↔ ω/(s² + ω²), cos ωt ↔ s/(s² + ω²), and a shift s → s + σ multiplies the time function by e−σt. To invert a rational F(s), split it into partial fractions: the residue of a simple pole p is A = [(s − p)·F(s)] at s = p. Final value theorem: f(∞) = lims→0 s·F(s), valid only when all poles of s·F(s) lie in the left half-plane. Initial value theorem: f(0⁺) = lims→∞ s·F(s).

Factor the denominator

s² + 4s + 4 = (s + 2)²

Partial fractions

5s + 1 = 5(s + 2) + −9
F(s) = 5/(s + 2) − 9/(s + 2)²

Inverse transform

f(t) = 5·e−2t − 9·t·e−2t
f(0.8) = (5 − 9·0.8)·e−2·0.8 = −0.4442

Answer

f(0.8) = −0.4442
2.Laplace transforms

Answer: y(0.1) = 5.244

Laplace transform: F(s) = ∫₀∞ f(t)·e−st dt turns derivatives into multiplications by s: ℒ{f′} = sF(s) − f(0), ℒ{f″} = s²F(s) − s·f(0) − f′(0). Standard pairs: 1 ↔ 1/s, e−at ↔ 1/(s + a), t·e−at ↔ 1/(s + a)², sin ωt ↔ ω/(s² + ω²), cos ωt ↔ s/(s² + ω²), and a shift s → s + σ multiplies the time function by e−σt. To invert a rational F(s), split it into partial fractions: the residue of a simple pole p is A = [(s − p)·F(s)] at s = p. Final value theorem: f(∞) = lims→0 s·F(s), valid only when all poles of s·F(s) lie in the left half-plane. Initial value theorem: f(0⁺) = lims→∞ s·F(s).

Transform the equation

Y(s) = 1500/(s(s + 5)(s + 6))

Partial fractions

A = 1500/(5·6) = 50
B = 1500/((−5)·1) = −300
C = 1500/((−6)·(−1)) = 250

Output

y(t) = 50 − 300·e−5t + 250·e−6t
y(0.1) = 5.244

Answer

y(0.1) = 5.244
3.Block diagrams

Answer: ess = 2.308

Block-diagram algebra: blocks in series multiply (G₁·G₂), blocks in parallel add (G₁ + G₂), and a loop with forward path G and feedback path H reduces to T = G/(1 + G·H) for negative feedback and G/(1 − G·H) for positive feedback. Reduce inner loops first, then work outwards. The closed-loop poles are the roots of the characteristic equation 1 + G(s)H(s) = 0. For a stable loop, a step input of size A gives the steady-state output A·T(0); with unity feedback the steady-state error to a step is A/(1 + Kp) with Kp = G(0).

Velocity error constant

Kᵥ = lims→0 s·G(s) = 26/6 = 4.333

Steady-state error

ess = A/Kᵥ = 10/4.333 = 2.308

Answer

ess = 2.308
4.Block diagrams

Answer: ωd = 3.122 rad/s

Block-diagram algebra: blocks in series multiply (G₁·G₂), blocks in parallel add (G₁ + G₂), and a loop with forward path G and feedback path H reduces to T = G/(1 + G·H) for negative feedback and G/(1 − G·H) for positive feedback. Reduce inner loops first, then work outwards. The closed-loop poles are the roots of the characteristic equation 1 + G(s)H(s) = 0. For a stable loop, a step input of size A gives the steady-state output A·T(0); with unity feedback the steady-state error to a step is A/(1 + Kp) with Kp = G(0).

Characteristic equation

s(s + 9) + 60·0.5 = 0 → s² + 9s + 30 = 0

Roots

s = −4.5 ± j·√(30 − 20.25) = −4.5 ± j3.122
ωd = 3.122 rad/s

Answer

ωd = 3.122 rad/s
5.Step response

Answer: ωn = 7.746 rad/s

Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).

Compare with the standard form

The denominator must match s² + 2ζωₙs + ωₙ².

ωₙ² = 60 → ωₙ = 7.746 rad/s
2ζωₙ = 7 → ζ = 7/(2·7.746) = 0.4518

Result

ωₙ = 7.746 rad/s

Answer

ωn = 7.746 rad/s
6.Step response

Answer: %OS = 15.6 %

Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).

Natural frequency and damping ratio

ωₙ = 1/√(LC) = 1/√(0.02·4.7 × 10⁻⁵) = 1031 rad/s
ζ = (R/2)·√(C/L) = (21/2)·√(4.7 × 10⁻⁵/0.02) = 0.509

Result

%OS = 100·e−ζπ/√(1−ζ²) = 15.6 %

Answer

%OS = 15.6 %
7.Stability: Routh–Hurwitz & root locus

Answer: Kmax = 378

Routh–Hurwitz criterion: a linear system is stable when every root of its characteristic polynomial lies in the left half of the s-plane. Write the coefficients alternately into the first two rows of the Routh array. Each entry of a new row comes from the two rows above it; for a cubic a₃s³ + a₂s² + a₁s + a₀ the s¹ entry is b₁ = (a₂·a₁ − a₃·a₀)/a₂. The number of sign changes in the first column equals the number of roots in the right half-plane. With a gain K in the coefficients, every first-column entry must stay positive: the gain that makes the s¹ entry zero is the stability limit, and the s² row then gives the frequency of the sustained oscillation.

Characteristic polynomial

s³ + 11s² + 38s + 40 + K = 0

Routh array

s³: 1, 38
s²: 11, 40 + K
s¹: (11·38 − 40 − K)/11
s⁰: 40 + K

Condition

The s¹ entry must stay positive.

K < 11·38 − 40 = 378

Answer

Kmax = 378

At the limit the loop oscillates at ω = √38 = 6.164 rad/s.

8.Stability: Routh–Hurwitz & root locus

Answer: K = 9

Root locus: as the gain K goes from 0 to ∞, the closed-loop poles, the roots of 1 + K·G(s) = 0, move from the open-loop poles to the open-loop zeros or to infinity. A point on the real axis belongs to the locus when the number of real poles and zeros to its right is odd. The n − m branches that go to infinity follow asymptotes at the angles (2q + 1)·180°/(n − m), which start from the centroid σₐ = (Σ poles − Σ zeros)/(n − m). Branches leave or join the real axis where dK/ds = 0. The angle condition ∠G(s) = 180° fixes the shape, and the magnitude condition K = 1/|G(s)| gives the gain at any point of the locus.

Break-away point

dK/ds = 0 for K = −(s + 1)(s + 7) gives 2s + 8 = 0.

sb = −4

Magnitude condition

K = |−4 + 1|·|−4 + 7| = 3·3 = 9

Answer

K = 9

For this gain the closed loop is critically damped (ζ = 1).

9.Steady-state error & PID control

Answer: K = 30

Steady-state error: in a unity-feedback loop with open-loop transfer function G(s) the error is E(s) = R(s)/(1 + G(s)), and by the final value theorem ess = lims→0 s·E(s). The system type is the number of poles of G(s) at s = 0. The error constants are Kp = lim G(s), Kv = lim s·G(s) and Ka = lim s²·G(s), all for s → 0. A step of size A gives ess = A/(1 + Kp), a ramp A·t gives A/Kv and a parabola A·t²/2 gives A/Ka. A type-0 loop follows a step with a finite error, a type-1 loop follows it exactly and a ramp with a finite error.

Required error constant

1/(1 + Kp) = 0.25 → Kp = 3

Gain

K/10 = 3 → K = 30

Answer

K = 30

Check the closed-loop stability as well: for this second-order loop any K > 0 is stable.

10.Steady-state error & PID control

Answer: tp = 0.8472 s

P, PI and PID control: the controller C(s) = Kp + Ki/s + Kd·s acts on the error. A proportional gain makes the loop faster and reduces the error of a type-0 plant, but never removes it. The integral term adds a pole at s = 0: the system type rises by one, and a step is followed without error. The derivative term adds damping. To choose gains, write the closed-loop characteristic polynomial and compare it with s² + 2ζωns + ωn². Then %OS = 100·e−ζπ/√(1−ζ²), tp = π/ωd with ωd = ωn√(1 − ζ²), and ts ≈ 4/(ζωn).

Characteristic polynomial

s(s + 5) + 5·4 = s² + 5s + 20

ωₙ and ζ

ωₙ = √20 = 4.472 rad/s
ζ = 5/(2·4.472) = 0.559

Peak time

ωd = 4.472·√(1 − 0.559²) = 3.708 rad/s
tp = π/3.708 = 0.8472 s

Answer

tp = 0.8472 s
11.Bode plots & margins

Answer: φ = −11.37 °

Frequency response: substitute s = jω in the transfer function. The magnitude in decibels is 20·log₁₀|H(jω)| and the phase is the sum of the angles of the numerator factors minus those of the denominator factors. A first-order RC or RL filter has its corner (−3 dB) frequency at ωc = 1/(RC) or R/L, and fc = ωc/(2π); a low-pass filter gives |H| = 1/√(1 + (ω/ωc)²) and φ = −atan(ω/ωc). In the asymptotic (straight-line) Bode plot each pole bends the magnitude down by 20 dB/decade at its corner frequency, each zero bends it up by 20 dB/decade, and an integrator 1/s gives −20 dB/decade at all frequencies. Gain crossover ωc: |L(jω)| = 1 (0 dB); phase margin PM = 180° + ∠L(jωc). Phase crossover ω180: ∠L(jω) = −180°; gain margin GM = −20·log₁₀|L(jω180)| dB. The closed loop is stable when both margins are positive.

Corner frequency

ωc = 1/(RC) = 1/(1000·1 × 10⁻⁸) = 100000 rad/s
fc = 15915 Hz → f/fc = 3200/15915 = 0.2011

Phase

φ = − atan(0.2011) = −11.37°

Answer

φ = −11.37°
12.Bode plots & margins

Answer: ωc = 1.432 rad/s

Frequency response: substitute s = jω in the transfer function. The magnitude in decibels is 20·log₁₀|H(jω)| and the phase is the sum of the angles of the numerator factors minus those of the denominator factors. A first-order RC or RL filter has its corner (−3 dB) frequency at ωc = 1/(RC) or R/L, and fc = ωc/(2π); a low-pass filter gives |H| = 1/√(1 + (ω/ωc)²) and φ = −atan(ω/ωc). In the asymptotic (straight-line) Bode plot each pole bends the magnitude down by 20 dB/decade at its corner frequency, each zero bends it up by 20 dB/decade, and an integrator 1/s gives −20 dB/decade at all frequencies. Gain crossover ωc: |L(jω)| = 1 (0 dB); phase margin PM = 180° + ∠L(jωc). Phase crossover ω180: ∠L(jω) = −180°; gain margin GM = −20·log₁₀|L(jω180)| dB. The closed loop is stable when both margins are positive.

Gain crossover

ω⁴ + 1ω² − 6.25 = 0
ω² = (−1 + √(1 + 4·6.25))/2 = 2.05
ωc = 1.432 rad/s

Answer

ωc = 1.432 rad/s

ExamProblems · examproblems.com/courses/control-engineering-1