In the print window, choose “Save as PDF” to keep a copy on your device.
1Formulas and methods
Stability: Routh–Hurwitz & root locus
Stability
all roots of the characteristic polynomial in the left half-plane
Routh array, s¹ entry of a cubic
b1 = (a2a1 − a3a0)/a2
Right half-plane roots
number of sign changes in the first column
Cubic s³ + a₂s² + a₁s + a₀
stable when all a > 0 and a₂·a₁ > a₀
K/(s(s + a)(s + b))
Kmax = ab(a + b), ω = √(ab)
Characteristic equation
1 + K·G(s) = 0
Asymptotes
σa = (Σp − Σz)/(n − m), θ = (2q + 1)·180°/(n − m)
Break-away and break-in points
dK/ds = 0
Magnitude condition
K = 1/|G(s)|
Angle of departure
θd = 180° − Σ∠(from other poles) + Σ∠(from zeros)
Method
Write the closed-loop characteristic polynomial: the denominator of 1 + K·G(s) = 0, multiplied out.
Put the coefficients alternately into the first two rows of the Routh array and build the remaining rows.
Count the sign changes in the first column: each one is a pole in the right half-plane. With K in the array, demand that every first-column entry stays positive.
For a root locus, mark the poles and zeros, the real-axis segments, the asymptotes from the centroid and the break points where dK/ds = 0. Use K = 1/|G(s)| for the gain at a point.
Steady-state error & PID control
System type
number of poles of G(s) at s = 0
Error constants
Kp = lim G(s), Kv = lim s·G(s), Ka = lim s²·G(s) (s → 0)
Step A
ess = A/(1 + Kp)
Ramp A·t
ess = A/Kv
Parabola A·t²/2
ess = A/Ka
PID controller
C(s) = Kp + Ki/s + Kd·s
Second-order target
s² + 2ζωns + ωn²
Overshoot and timing
%OS = 100·e−ζπ/√(1−ζ²), tp = π/ωd, ts ≈ 4/(ζωn)
Method
Count the poles of the open loop C(s)·G(s) at s = 0: that is the system type.
Work out the error constant that matches the input: Kp for a step, Kv for a ramp, Ka for a parabola.
Apply ess = A/(1 + Kp), A/Kv or A/Ka, or solve it for the gain you need.
For a damping or speed specification, write the closed-loop characteristic polynomial and match it with s² + 2ζω_n·s + ω_n².
2Practice problems
1.Laplace transformsMedium
Find f(t) for F(s) = (3s + 16)/(s² + 4s + 5) by completing the square, and evaluate f(0.4).
F(s) = (3s + 16)/(s² + 4s + 5)t = 0.4 s
f(0.4) =
2.Laplace transformsHard
A system obeys y″ + 9y′ + 18y = 9·u(t). It starts at rest (y(0) = 0, y′(0) = 0) and the input is a step u(t) = 1 for t ≥ 0. Use the Laplace transform to find the output y(0.3).
A plant G(s) = 30/(s + 1) is controlled in a negative feedback loop whose sensor has the gain H = 0.1. A step of size 5 is applied at R. Find the steady-state output css.
G(s) = 30/(s + 1)H = 0.1R = 5
css =
4.Block diagramsHard
The plant G(s) = K/(s(s + 2)(s + 5)) is in a unity negative feedback loop. At the largest stable gain the loop oscillates. Find the frequency of oscillation ω in rad/s.
G(s) = K/(s(s + 2)(s + 5))unity negative feedback
ω = rad/s
5.Step responseMedium
A system has the transfer function G(s) = 20.5/(s² + 7s + 41) and receives a unit step input. Find the natural frequency ωn in rad/s.
G(s) = 20.5/(s² + 7s + 41)
ωn = rad/s
6.Step responseHard
A unity negative feedback loop has G(s) = K/(s(s + 8)). Find the gain K that gives a step response with 25 % overshoot.
G(s) = K/(s(s + 8))%OS = 25 %
K =
7.Stability: Routh–Hurwitz & root locusMedium
A unity-feedback loop has L(s) = K/((s + 1)(s + 3)(s + 5)), with K > 0. Find the largest gain Kmax for which the closed loop is stable.
L(s) = K/((s + 1)(s + 3)(s + 5))
Kmax =
8.Stability: Routh–Hurwitz & root locusHard
The root locus of L(s) = K/(s(s + 4)) is shown. Find the gain K for which the closed-loop poles have the damping ratio ζ = 0.3.
L(s) = K/(s(s + 4))ζ = 0.3
K =
9.Steady-state error & PID controlMedium
A process G(s) = 2.5/(2s + 1) is controlled by a proportional gain K = 2 in a unity-feedback loop. Find the steady-state error ess for a step, as a percentage of the step size.
G(s) = 2.5/(2s + 1)K = 2
ess = %
10.Steady-state error & PID controlHard
A proportional controller K = 4 drives the plant G(s) = 5/(s(s + 5)) in a unity-feedback loop. Find the peak time tp of the step response.
G(s) = 5/(s(s + 5))K = 4
tp = s
11.Bode plots & marginsMedium
Find the phase ∠G(jω) of G(s) = 19(s + 19)/(s(s + 12)) at ω = 0.5 rad/s, in degrees.
G(s) = 19(s + 19)/(s(s + 12))ω = 0.5 rad/s
∠G(jω) = °
12.Bode plots & marginsHard
A unity-feedback loop has the open-loop transfer function L(s) = 13.2/(s(s + 4)). Find the gain crossover frequency ωc, where |L(jω)| = 1.
L(s) = 13.2/(s(s + 4))
ωc = rad/s
3Solutions
1.Laplace transforms
Answer: f(0.4) = 2.991
Laplace transform: F(s) = ∫₀∞ f(t)·e−st dt turns derivatives into multiplications by s: ℒ{f′} = sF(s) − f(0), ℒ{f″} = s²F(s) − s·f(0) − f′(0). Standard pairs: 1 ↔ 1/s, e−at ↔ 1/(s + a), t·e−at ↔ 1/(s + a)², sin ωt ↔ ω/(s² + ω²), cos ωt ↔ s/(s² + ω²), and a shift s → s + σ multiplies the time function by e−σt. To invert a rational F(s), split it into partial fractions: the residue of a simple pole p is A = [(s − p)·F(s)] at s = p. Final value theorem: f(∞) = lims→0 s·F(s), valid only when all poles of s·F(s) lie in the left half-plane. Initial value theorem: f(0⁺) = lims→∞ s·F(s).
Laplace transform: F(s) = ∫₀∞ f(t)·e−st dt turns derivatives into multiplications by s: ℒ{f′} = sF(s) − f(0), ℒ{f″} = s²F(s) − s·f(0) − f′(0). Standard pairs: 1 ↔ 1/s, e−at ↔ 1/(s + a), t·e−at ↔ 1/(s + a)², sin ωt ↔ ω/(s² + ω²), cos ωt ↔ s/(s² + ω²), and a shift s → s + σ multiplies the time function by e−σt. To invert a rational F(s), split it into partial fractions: the residue of a simple pole p is A = [(s − p)·F(s)] at s = p. Final value theorem: f(∞) = lims→0 s·F(s), valid only when all poles of s·F(s) lie in the left half-plane. Initial value theorem: f(0⁺) = lims→∞ s·F(s).
Transform the equation
Y(s) = 9/(s(s + 3)(s + 6))
Partial fractions
A = 9/(3·6) = 0.5
B = 9/((−3)·3) = −1
C = 9/((−6)·(−3)) = 0.5
Output
y(t) = 0.5 − e−3t + 0.5·e−6t
y(0.3) = 0.1761
Answer
y(0.3) = 0.1761
3.Block diagrams
Answer: css = 37.5
Block-diagram algebra: blocks in series multiply (G₁·G₂), blocks in parallel add (G₁ + G₂), and a loop with forward path G and feedback path H reduces to T = G/(1 + G·H) for negative feedback and G/(1 − G·H) for positive feedback. Reduce inner loops first, then work outwards. The closed-loop poles are the roots of the characteristic equation 1 + G(s)H(s) = 0. For a stable loop, a step input of size A gives the steady-state output A·T(0); with unity feedback the steady-state error to a step is A/(1 + Kp) with Kp = G(0).
Closed-loop transfer function
T(s) = G/(1 + G·H) = 30/(s + 1 + 3) = 30/(s + 4)
Result
css = R·T(0) = 5·30/4 = 37.5
Answer
css = 37.5
4.Block diagrams
Answer: ω = 3.162 rad/s
Block-diagram algebra: blocks in series multiply (G₁·G₂), blocks in parallel add (G₁ + G₂), and a loop with forward path G and feedback path H reduces to T = G/(1 + G·H) for negative feedback and G/(1 − G·H) for positive feedback. Reduce inner loops first, then work outwards. The closed-loop poles are the roots of the characteristic equation 1 + G(s)H(s) = 0. For a stable loop, a step input of size A gives the steady-state output A·T(0); with unity feedback the steady-state error to a step is A/(1 + Kp) with Kp = G(0).
Characteristic equation
s³ + 7s² + 10s + K = 0
Routh array
s³ | 1 10
s² | 7 K
s¹ | (7·10 − K)/7
s⁰ | K
Stability limit
All entries of the first column must be positive.
Kmax = 7·10 = 70
Frequency of oscillation
7·(jω)² + 70 = 0 → ω² = 70/7 = 10
ω = 3.162 rad/s
Answer
ω = 3.162 rad/s
5.Step response
Answer: ωn = 6.403 rad/s
Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).
Compare with the standard form
The denominator must match s² + 2ζωₙs + ωₙ².
ωₙ² = 41 → ωₙ = 6.403 rad/s
2ζωₙ = 7 → ζ = 7/(2·6.403) = 0.5466
Result
ωₙ = 6.403 rad/s
Answer
ωn = 6.403 rad/s
6.Step response
Answer: K = 98.17
Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).
Closed-loop transfer function
T(s) = K/(s² + 8s + K)
Damping ratio from the overshoot
ζ = −ln(0.25)/√(π² + ln²(0.25)) = 0.4037
Gain
ωₙ = 8/(2ζ) = 9.908 rad/s
K = ωₙ² = 98.17
Answer
K = 98.17
7.Stability: Routh–Hurwitz & root locus
Answer: Kmax = 192
Routh–Hurwitz criterion: a linear system is stable when every root of its characteristic polynomial lies in the left half of the s-plane. Write the coefficients alternately into the first two rows of the Routh array. Each entry of a new row comes from the two rows above it; for a cubic a₃s³ + a₂s² + a₁s + a₀ the s¹ entry is b₁ = (a₂·a₁ − a₃·a₀)/a₂. The number of sign changes in the first column equals the number of roots in the right half-plane. With a gain K in the coefficients, every first-column entry must stay positive: the gain that makes the s¹ entry zero is the stability limit, and the s² row then gives the frequency of the sustained oscillation.
Characteristic polynomial
s³ + 9s² + 23s + 15 + K = 0
Routh array
s³: 1, 23
s²: 9, 15 + K
s¹: (9·23 − 15 − K)/9
s⁰: 15 + K
Condition
The s¹ entry must stay positive.
K < 9·23 − 15 = 192
Answer
Kmax = 192
At the limit the loop oscillates at ω = √23 = 4.796 rad/s.
8.Stability: Routh–Hurwitz & root locus
Answer: K = 44.44
Root locus: as the gain K goes from 0 to ∞, the closed-loop poles, the roots of 1 + K·G(s) = 0, move from the open-loop poles to the open-loop zeros or to infinity. A point on the real axis belongs to the locus when the number of real poles and zeros to its right is odd. The n − m branches that go to infinity follow asymptotes at the angles (2q + 1)·180°/(n − m), which start from the centroid σₐ = (Σ poles − Σ zeros)/(n − m). Branches leave or join the real axis where dK/ds = 0. The angle condition ∠G(s) = 180° fixes the shape, and the magnitude condition K = 1/|G(s)| gives the gain at any point of the locus.
Compare with the standard form
s² + 4s + K = s² + 2ζωₙs + ωₙ²
2·0.3·ωₙ = 4 → ωₙ = 6.667 rad/s
Gain
K = ωₙ² = 6.667² = 44.44
Answer
K = 44.44
The closed-loop poles sit where the ζ line crosses the vertical branch at s = −2.
9.Steady-state error & PID control
Answer: ess = 16.67 %
Steady-state error: in a unity-feedback loop with open-loop transfer function G(s) the error is E(s) = R(s)/(1 + G(s)), and by the final value theorem ess = lims→0 s·E(s). The system type is the number of poles of G(s) at s = 0. The error constants are Kp = lim G(s), Kv = lim s·G(s) and Ka = lim s²·G(s), all for s → 0. A step of size A gives ess = A/(1 + Kp), a ramp A·t gives A/Kv and a parabola A·t²/2 gives A/Ka. A type-0 loop follows a step with a finite error, a type-1 loop follows it exactly and a ramp with a finite error.
Position constant
Kp = 2·2.5 = 5
Step error
ess = 100/(1 + 5) = 16.67 %
Answer
ess = 16.67 %
10.Steady-state error & PID control
Answer: tp = 0.8472 s
P, PI and PID control: the controller C(s) = Kp + Ki/s + Kd·s acts on the error. A proportional gain makes the loop faster and reduces the error of a type-0 plant, but never removes it. The integral term adds a pole at s = 0: the system type rises by one, and a step is followed without error. The derivative term adds damping. To choose gains, write the closed-loop characteristic polynomial and compare it with s² + 2ζωns + ωn². Then %OS = 100·e−ζπ/√(1−ζ²), tp = π/ωd with ωd = ωn√(1 − ζ²), and ts ≈ 4/(ζωn).
Characteristic polynomial
s(s + 5) + 4·5 = s² + 5s + 20
ωₙ and ζ
ωₙ = √20 = 4.472 rad/s
ζ = 5/(2·4.472) = 0.559
Peak time
ωd = 4.472·√(1 − 0.559²) = 3.708 rad/s
tp = π/3.708 = 0.8472 s
Answer
tp = 0.8472 s
11.Bode plots & margins
Answer: ∠G(jω) = −90.88 °
Frequency response: substitute s = jω in the transfer function. The magnitude in decibels is 20·log₁₀|H(jω)| and the phase is the sum of the angles of the numerator factors minus those of the denominator factors. A first-order RC or RL filter has its corner (−3 dB) frequency at ωc = 1/(RC) or R/L, and fc = ωc/(2π); a low-pass filter gives |H| = 1/√(1 + (ω/ωc)²) and φ = −atan(ω/ωc). In the asymptotic (straight-line) Bode plot each pole bends the magnitude down by 20 dB/decade at its corner frequency, each zero bends it up by 20 dB/decade, and an integrator 1/s gives −20 dB/decade at all frequencies. Gain crossover ωc: |L(jω)| = 1 (0 dB); phase margin PM = 180° + ∠L(jωc). Phase crossover ω180: ∠L(jω) = −180°; gain margin GM = −20·log₁₀|L(jω180)| dB. The closed loop is stable when both margins are positive.
Frequency response: substitute s = jω in the transfer function. The magnitude in decibels is 20·log₁₀|H(jω)| and the phase is the sum of the angles of the numerator factors minus those of the denominator factors. A first-order RC or RL filter has its corner (−3 dB) frequency at ωc = 1/(RC) or R/L, and fc = ωc/(2π); a low-pass filter gives |H| = 1/√(1 + (ω/ωc)²) and φ = −atan(ω/ωc). In the asymptotic (straight-line) Bode plot each pole bends the magnitude down by 20 dB/decade at its corner frequency, each zero bends it up by 20 dB/decade, and an integrator 1/s gives −20 dB/decade at all frequencies. Gain crossover ωc: |L(jω)| = 1 (0 dB); phase margin PM = 180° + ∠L(jωc). Phase crossover ω180: ∠L(jω) = −180°; gain margin GM = −20·log₁₀|L(jω180)| dB. The closed loop is stable when both margins are positive.