In the print window, choose “Save as PDF” to keep a copy on your device.
1Formulas and methods
Stability: Routh–Hurwitz & root locus
Stability
all roots of the characteristic polynomial in the left half-plane
Routh array, s¹ entry of a cubic
b1 = (a2a1 − a3a0)/a2
Right half-plane roots
number of sign changes in the first column
Cubic s³ + a₂s² + a₁s + a₀
stable when all a > 0 and a₂·a₁ > a₀
K/(s(s + a)(s + b))
Kmax = ab(a + b), ω = √(ab)
Characteristic equation
1 + K·G(s) = 0
Asymptotes
σa = (Σp − Σz)/(n − m), θ = (2q + 1)·180°/(n − m)
Break-away and break-in points
dK/ds = 0
Magnitude condition
K = 1/|G(s)|
Angle of departure
θd = 180° − Σ∠(from other poles) + Σ∠(from zeros)
Method
Write the closed-loop characteristic polynomial: the denominator of 1 + K·G(s) = 0, multiplied out.
Put the coefficients alternately into the first two rows of the Routh array and build the remaining rows.
Count the sign changes in the first column: each one is a pole in the right half-plane. With K in the array, demand that every first-column entry stays positive.
For a root locus, mark the poles and zeros, the real-axis segments, the asymptotes from the centroid and the break points where dK/ds = 0. Use K = 1/|G(s)| for the gain at a point.
Steady-state error & PID control
System type
number of poles of G(s) at s = 0
Error constants
Kp = lim G(s), Kv = lim s·G(s), Ka = lim s²·G(s) (s → 0)
Step A
ess = A/(1 + Kp)
Ramp A·t
ess = A/Kv
Parabola A·t²/2
ess = A/Ka
PID controller
C(s) = Kp + Ki/s + Kd·s
Second-order target
s² + 2ζωns + ωn²
Overshoot and timing
%OS = 100·e−ζπ/√(1−ζ²), tp = π/ωd, ts ≈ 4/(ζωn)
Method
Count the poles of the open loop C(s)·G(s) at s = 0: that is the system type.
Work out the error constant that matches the input: Kp for a step, Kv for a ramp, Ka for a parabola.
Apply ess = A/(1 + Kp), A/Kv or A/Ka, or solve it for the gain you need.
For a damping or speed specification, write the closed-loop characteristic polynomial and match it with s² + 2ζω_n·s + ω_n².
2Practice problems
1.Laplace transformsMedium
F(s) = (4s + 18)/(s² + 13s + 42). Its inverse transform has the form f(t) = A·e−6t + B·e−7t. Find the coefficient A by partial fractions.
F(s) = (4s + 18)/(s² + 13s + 42)
A =
2.Laplace transformsHard
A system is described by the differential equation y″ + 5y′ + 6y = 14u, with input u(t) and output y(t). Find its transfer function G(s) = Y(s)/U(s) (zero initial conditions) and evaluate the impulse response g(t) at t = 0.6 s. Find g(0.6).
y″ + 5y′ + 6y = 14ut = 0.6 s
g(0.6) =
3.Block diagramsMedium
The plant G(s) = 6/(s + 5) has an inner (minor) negative feedback loop with gain H₁ = 3. A controller gain K = 17 and an outer unity negative feedback loop close the system. Find the closed-loop pole p.
G(s) = 6/(s + 5)H₁ = 3K = 17
p =
4.Block diagramsHard
A proportional controller K drives the plant G(s) = 7/(s + 1) in a unity negative feedback loop. A disturbance step of size 5 enters at the plant input while R = 0. Find the smallest gain K that keeps the steady-state output at or below 7.
G(s) = 7/(s + 1)D = 5css ≤ 7
K =
5.Step responseMedium
A system has the transfer function G(s) = 12/(s² + s + 12) and receives a unit step input. Find the damping ratio ζ.
G(s) = 12/(s² + s + 12)
ζ =
6.Step responseHard
A series RLC circuit with R = 124 Ω, L = 50 mH and C = 4.7 µF is connected to a 24 V step at t = 0. The capacitor is uncharged and no current flows before the step. Find the percent overshoot %OS of the capacitor voltage.
R = 124 ΩL = 50 mHC = 4.7 µFV = 24 V
%OS = %
7.Stability: Routh–Hurwitz & root locusMedium
A unity-feedback loop has L(s) = K/((s + 2)(s + 4)(s + 5)), with K > 0. Find the largest gain Kmax for which the closed loop is stable.
L(s) = K/((s + 2)(s + 4)(s + 5))
Kmax =
8.Stability: Routh–Hurwitz & root locusHard
The root locus of L(s) = K/(s(s + 5)) is shown. Find the gain K for which the closed-loop poles have the damping ratio ζ = 0.707.
L(s) = K/(s(s + 5))ζ = 0.707
K =
9.Steady-state error & PID controlMedium
A unity-feedback loop with G(s) = K/(s(s + 5)) must follow the ramp r(t) = 5t with a steady-state error of 0.2. Find the gain K.
G(s) = K/(s(s + 5))r(t) = 5tess = 0.2
K =
10.Steady-state error & PID controlHard
A proportional controller K drives the plant G(s) = 1/(s(s + 4)) in a unity-feedback loop. Find the gain K that gives the closed loop a damping ratio ζ = 0.707.
G(s) = 1/(s(s + 4))ζ = 0.707
K =
11.Bode plots & marginsMedium
Find the exact magnitude |G(jω)| of G(s) = 54/((s + 1)(s + 9)) at ω = 30 rad/s, in dB.
G(s) = 54/((s + 1)(s + 9))ω = 30 rad/s
|G(jω)| = dB
12.Bode plots & marginsHard
A unity-feedback loop has the open-loop transfer function L(s) = 4/(s(s + 4)). Find the phase margin PM in degrees.
L(s) = 4/(s(s + 4))
PM = °
3Solutions
1.Laplace transforms
Answer: A = −6
Laplace transform: F(s) = ∫₀∞ f(t)·e−st dt turns derivatives into multiplications by s: ℒ{f′} = sF(s) − f(0), ℒ{f″} = s²F(s) − s·f(0) − f′(0). Standard pairs: 1 ↔ 1/s, e−at ↔ 1/(s + a), t·e−at ↔ 1/(s + a)², sin ωt ↔ ω/(s² + ω²), cos ωt ↔ s/(s² + ω²), and a shift s → s + σ multiplies the time function by e−σt. To invert a rational F(s), split it into partial fractions: the residue of a simple pole p is A = [(s − p)·F(s)] at s = p. Final value theorem: f(∞) = lims→0 s·F(s), valid only when all poles of s·F(s) lie in the left half-plane. Initial value theorem: f(0⁺) = lims→∞ s·F(s).
Factor the denominator
s² + 13s + 42 = (s + 6)(s + 7)
F(s) = A/(s + 6) + B/(s + 7)
Cover-up rule
Multiply by (s + 6) and set s = −6: the B-term vanishes.
A = (4s + 18)/(s + 7) |s = −6 = −6/1 = −6
Answer
A = −6
(B = 10, so f(t) = −6·e−6t + 10·e−7t)
2.Laplace transforms
Answer: g(0.6) = 1.903
Laplace transform: F(s) = ∫₀∞ f(t)·e−st dt turns derivatives into multiplications by s: ℒ{f′} = sF(s) − f(0), ℒ{f″} = s²F(s) − s·f(0) − f′(0). Standard pairs: 1 ↔ 1/s, e−at ↔ 1/(s + a), t·e−at ↔ 1/(s + a)², sin ωt ↔ ω/(s² + ω²), cos ωt ↔ s/(s² + ω²), and a shift s → s + σ multiplies the time function by e−σt. To invert a rational F(s), split it into partial fractions: the residue of a simple pole p is A = [(s − p)·F(s)] at s = p. Final value theorem: f(∞) = lims→0 s·F(s), valid only when all poles of s·F(s) lie in the left half-plane. Initial value theorem: f(0⁺) = lims→∞ s·F(s).
Transfer function
G(s) = Y(s)/U(s) = 14/(s² + 5s + 6)
Partial fractions
s² + 5s + 6 = (s + 2)(s + 3)
A = 14, B = −14
Impulse response
g(t) = 14·e−2t − 14·e−3t
g(0.6) = 1.903
Answer
g(0.6) = 1.903
3.Block diagrams
Answer: p = −125
Block-diagram algebra: blocks in series multiply (G₁·G₂), blocks in parallel add (G₁ + G₂), and a loop with forward path G and feedback path H reduces to T = G/(1 + G·H) for negative feedback and G/(1 − G·H) for positive feedback. Reduce inner loops first, then work outwards. The closed-loop poles are the roots of the characteristic equation 1 + G(s)H(s) = 0. For a stable loop, a step input of size A gives the steady-state output A·T(0); with unity feedback the steady-state error to a step is A/(1 + Kp) with Kp = G(0).
Block-diagram algebra: blocks in series multiply (G₁·G₂), blocks in parallel add (G₁ + G₂), and a loop with forward path G and feedback path H reduces to T = G/(1 + G·H) for negative feedback and G/(1 − G·H) for positive feedback. Reduce inner loops first, then work outwards. The closed-loop poles are the roots of the characteristic equation 1 + G(s)H(s) = 0. For a stable loop, a step input of size A gives the steady-state output A·T(0); with unity feedback the steady-state error to a step is A/(1 + Kp) with Kp = G(0).
Disturbance response
css = D·G(0)/(1 + K·G(0)) = 5·7/(1 + 7K)
Solve for K
1 + 7K = 5·7/7 = 5
K = (5 − 1)/7 = 0.5714
Answer
K = 0.5714
5.Step response
Answer: ζ = 0.1443
Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).
Compare with the standard form
The denominator must match s² + 2ζωₙs + ωₙ².
ωₙ² = 12 → ωₙ = 3.464 rad/s
2ζωₙ = 1 → ζ = 1/(2·3.464) = 0.1443
Result
ζ = 0.1443
Answer
ζ = 0.1443
6.Step response
Answer: %OS = 9.413 %
Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).
Routh–Hurwitz criterion: a linear system is stable when every root of its characteristic polynomial lies in the left half of the s-plane. Write the coefficients alternately into the first two rows of the Routh array. Each entry of a new row comes from the two rows above it; for a cubic a₃s³ + a₂s² + a₁s + a₀ the s¹ entry is b₁ = (a₂·a₁ − a₃·a₀)/a₂. The number of sign changes in the first column equals the number of roots in the right half-plane. With a gain K in the coefficients, every first-column entry must stay positive: the gain that makes the s¹ entry zero is the stability limit, and the s² row then gives the frequency of the sustained oscillation.
Characteristic polynomial
s³ + 11s² + 38s + 40 + K = 0
Routh array
s³: 1, 38
s²: 11, 40 + K
s¹: (11·38 − 40 − K)/11
s⁰: 40 + K
Condition
The s¹ entry must stay positive.
K < 11·38 − 40 = 378
Answer
Kmax = 378
At the limit the loop oscillates at ω = √38 = 6.164 rad/s.
8.Stability: Routh–Hurwitz & root locus
Answer: K = 12.5
Root locus: as the gain K goes from 0 to ∞, the closed-loop poles, the roots of 1 + K·G(s) = 0, move from the open-loop poles to the open-loop zeros or to infinity. A point on the real axis belongs to the locus when the number of real poles and zeros to its right is odd. The n − m branches that go to infinity follow asymptotes at the angles (2q + 1)·180°/(n − m), which start from the centroid σₐ = (Σ poles − Σ zeros)/(n − m). Branches leave or join the real axis where dK/ds = 0. The angle condition ∠G(s) = 180° fixes the shape, and the magnitude condition K = 1/|G(s)| gives the gain at any point of the locus.
Compare with the standard form
s² + 5s + K = s² + 2ζωₙs + ωₙ²
2·0.707·ωₙ = 5 → ωₙ = 3.536 rad/s
Gain
K = ωₙ² = 3.536² = 12.5
Answer
K = 12.5
The closed-loop poles sit where the ζ line crosses the vertical branch at s = −2.5.
9.Steady-state error & PID control
Answer: K = 125
Steady-state error: in a unity-feedback loop with open-loop transfer function G(s) the error is E(s) = R(s)/(1 + G(s)), and by the final value theorem ess = lims→0 s·E(s). The system type is the number of poles of G(s) at s = 0. The error constants are Kp = lim G(s), Kv = lim s·G(s) and Ka = lim s²·G(s), all for s → 0. A step of size A gives ess = A/(1 + Kp), a ramp A·t gives A/Kv and a parabola A·t²/2 gives A/Ka. A type-0 loop follows a step with a finite error, a type-1 loop follows it exactly and a ramp with a finite error.
Required velocity constant
Kv = A/ess = 5/0.2 = 25
Gain
K = 5·Kv = 125
Answer
K = 125
A large gain makes this loop very lightly damped: ζ = 0.2236. That conflict is why compensators are used.
10.Steady-state error & PID control
Answer: K = 8.002
P, PI and PID control: the controller C(s) = Kp + Ki/s + Kd·s acts on the error. A proportional gain makes the loop faster and reduces the error of a type-0 plant, but never removes it. The integral term adds a pole at s = 0: the system type rises by one, and a step is followed without error. The derivative term adds damping. To choose gains, write the closed-loop characteristic polynomial and compare it with s² + 2ζωns + ωn². Then %OS = 100·e−ζπ/√(1−ζ²), tp = π/ωd with ωd = ωn√(1 − ζ²), and ts ≈ 4/(ζωn).
Characteristic polynomial
s(s + 4) + 1K = s² + 4s + 1K
Natural frequency
2·0.707·ωₙ = 4 → ωₙ = 2.829 rad/s
Gain
1K = ωₙ² = 8.002 → K = 8.002
Answer
K = 8.002
11.Bode plots & margins
Answer: |G(jω)| = −24.82 dB
Frequency response: substitute s = jω in the transfer function. The magnitude in decibels is 20·log₁₀|H(jω)| and the phase is the sum of the angles of the numerator factors minus those of the denominator factors. A first-order RC or RL filter has its corner (−3 dB) frequency at ωc = 1/(RC) or R/L, and fc = ωc/(2π); a low-pass filter gives |H| = 1/√(1 + (ω/ωc)²) and φ = −atan(ω/ωc). In the asymptotic (straight-line) Bode plot each pole bends the magnitude down by 20 dB/decade at its corner frequency, each zero bends it up by 20 dB/decade, and an integrator 1/s gives −20 dB/decade at all frequencies. Gain crossover ωc: |L(jω)| = 1 (0 dB); phase margin PM = 180° + ∠L(jωc). Phase crossover ω180: ∠L(jω) = −180°; gain margin GM = −20·log₁₀|L(jω180)| dB. The closed loop is stable when both margins are positive.
Frequency response: substitute s = jω in the transfer function. The magnitude in decibels is 20·log₁₀|H(jω)| and the phase is the sum of the angles of the numerator factors minus those of the denominator factors. A first-order RC or RL filter has its corner (−3 dB) frequency at ωc = 1/(RC) or R/L, and fc = ωc/(2π); a low-pass filter gives |H| = 1/√(1 + (ω/ωc)²) and φ = −atan(ω/ωc). In the asymptotic (straight-line) Bode plot each pole bends the magnitude down by 20 dB/decade at its corner frequency, each zero bends it up by 20 dB/decade, and an integrator 1/s gives −20 dB/decade at all frequencies. Gain crossover ωc: |L(jω)| = 1 (0 dB); phase margin PM = 180° + ∠L(jωc). Phase crossover ω180: ∠L(jω) = −180°; gain margin GM = −20·log₁₀|L(jω180)| dB. The closed loop is stable when both margins are positive.