In the print window, choose “Save as PDF” to keep a copy on your device.
1Formulas and methods
Stability: Routh–Hurwitz & root locus
Stability
all roots of the characteristic polynomial in the left half-plane
Routh array, s¹ entry of a cubic
b1 = (a2a1 − a3a0)/a2
Right half-plane roots
number of sign changes in the first column
Cubic s³ + a₂s² + a₁s + a₀
stable when all a > 0 and a₂·a₁ > a₀
K/(s(s + a)(s + b))
Kmax = ab(a + b), ω = √(ab)
Characteristic equation
1 + K·G(s) = 0
Asymptotes
σa = (Σp − Σz)/(n − m), θ = (2q + 1)·180°/(n − m)
Break-away and break-in points
dK/ds = 0
Magnitude condition
K = 1/|G(s)|
Angle of departure
θd = 180° − Σ∠(from other poles) + Σ∠(from zeros)
Method
Write the closed-loop characteristic polynomial: the denominator of 1 + K·G(s) = 0, multiplied out.
Put the coefficients alternately into the first two rows of the Routh array and build the remaining rows.
Count the sign changes in the first column: each one is a pole in the right half-plane. With K in the array, demand that every first-column entry stays positive.
For a root locus, mark the poles and zeros, the real-axis segments, the asymptotes from the centroid and the break points where dK/ds = 0. Use K = 1/|G(s)| for the gain at a point.
Steady-state error & PID control
System type
number of poles of G(s) at s = 0
Error constants
Kp = lim G(s), Kv = lim s·G(s), Ka = lim s²·G(s) (s → 0)
Step A
ess = A/(1 + Kp)
Ramp A·t
ess = A/Kv
Parabola A·t²/2
ess = A/Ka
PID controller
C(s) = Kp + Ki/s + Kd·s
Second-order target
s² + 2ζωns + ωn²
Overshoot and timing
%OS = 100·e−ζπ/√(1−ζ²), tp = π/ωd, ts ≈ 4/(ζωn)
Method
Count the poles of the open loop C(s)·G(s) at s = 0: that is the system type.
Work out the error constant that matches the input: Kp for a step, Kv for a ramp, Ka for a parabola.
Apply ess = A/(1 + Kp), A/Kv or A/Ka, or solve it for the gain you need.
For a damping or speed specification, write the closed-loop characteristic polynomial and match it with s² + 2ζω_n·s + ω_n².
2Practice problems
1.Laplace transformsMedium
Find f(t) for F(s) = 55/(s(s + 4)(s + 6)) by partial fractions, and evaluate f(0.25).
F(s) = 55/(s(s + 4)(s + 6))t = 0.25 s
f(0.25) =
2.Laplace transformsHard
A system obeys y″ + 6y′ + 5y = 5·u(t). It starts at rest (y(0) = 0, y′(0) = 0) and the input is a step u(t) = 5 for t ≥ 0. Use the Laplace transform to find the output y(0.4).
The plant G(s) = K/((s + 8)(s + 10)) is in a unity negative feedback loop. Find the gain K for which the closed loop is critically damped (two equal real poles).
G(s) = K/((s + 8)(s + 10))unity negative feedback
K =
4.Block diagramsHard
A proportional controller K = 28 drives the plant G(s) = 4/(s + 7) in a unity negative feedback loop. A disturbance D enters at the plant input (it is added to the controller output). A reference step of size 2 and a disturbance step of size 2 are applied together. Find the steady-state output css.
K = 28G(s) = 4/(s + 7)D = 2R = 2
css =
5.Step responseMedium
A system has the transfer function G(s) = 297/(s² + 12s + 99) and receives a unit step input. Find the peak time tp of the step response.
G(s) = 297/(s² + 12s + 99)
tp = s
6.Step responseHard
A series RLC circuit with R = 27 Ω, L = 50 mH and C = 100 µF is connected to a 10 V step at t = 0. The capacitor is uncharged and no current flows before the step. Find the undamped natural frequency ωn in rad/s.
R = 27 ΩL = 50 mHC = 100 µFV = 10 V
ωn = rad/s
7.Stability: Routh–Hurwitz & root locusMedium
The plant G(s) = (s + 5)/((s − 4)(s + 2)) has an unstable pole at s = 4. A proportional gain K closes a unity-feedback loop around it. Find the smallest gain Kmin that makes the closed loop stable.
G(s) = (s + 5)/((s − 4)(s + 2))
Kmin =
8.Stability: Routh–Hurwitz & root locusHard
For L(s) = K/((s + 2)(s² + 2s + 10)), find the angle of departure θd of the root locus from the complex pole in the upper half-plane, measured from the positive real axis.
L(s) = K/((s + 2)(s² + 2s + 10))
θd = °
9.Steady-state error & PID controlMedium
A unity-feedback loop with G(s) = K/(s(s + 1)) must follow the ramp r(t) = 2t with a steady-state error of 0.1. Find the gain K.
G(s) = K/(s(s + 1))r(t) = 2tess = 0.1
K =
10.Steady-state error & PID controlHard
A proportional controller K = 16 drives the plant G(s) = 4/(s(s + 10)) in a unity-feedback loop. Find the percent overshoot %OS of the step response.
G(s) = 4/(s(s + 10))K = 16
%OS = %
11.Bode plots & marginsMedium
In the series RLC band-pass filter shown the output is taken across R = 50 Ω, with L = 50 mH and C = 0.22 µF. Find the centre (resonant) frequency f0 in Hz.
R = 50 ΩL = 50 mHC = 0.22 µF
f0 = Hz
12.Bode plots & marginsHard
A unity-feedback loop has the open-loop transfer function L(s) = 10/(s(s + 1)(s + 5)). Find the gain margin GM in dB.
L(s) = 10/(s(s + 1)(s + 5))
GM = dB
3Solutions
1.Laplace transforms
Answer: f(0.25) = 0.7852
Laplace transform: F(s) = ∫₀∞ f(t)·e−st dt turns derivatives into multiplications by s: ℒ{f′} = sF(s) − f(0), ℒ{f″} = s²F(s) − s·f(0) − f′(0). Standard pairs: 1 ↔ 1/s, e−at ↔ 1/(s + a), t·e−at ↔ 1/(s + a)², sin ωt ↔ ω/(s² + ω²), cos ωt ↔ s/(s² + ω²), and a shift s → s + σ multiplies the time function by e−σt. To invert a rational F(s), split it into partial fractions: the residue of a simple pole p is A = [(s − p)·F(s)] at s = p. Final value theorem: f(∞) = lims→0 s·F(s), valid only when all poles of s·F(s) lie in the left half-plane. Initial value theorem: f(0⁺) = lims→∞ s·F(s).
Laplace transform: F(s) = ∫₀∞ f(t)·e−st dt turns derivatives into multiplications by s: ℒ{f′} = sF(s) − f(0), ℒ{f″} = s²F(s) − s·f(0) − f′(0). Standard pairs: 1 ↔ 1/s, e−at ↔ 1/(s + a), t·e−at ↔ 1/(s + a)², sin ωt ↔ ω/(s² + ω²), cos ωt ↔ s/(s² + ω²), and a shift s → s + σ multiplies the time function by e−σt. To invert a rational F(s), split it into partial fractions: the residue of a simple pole p is A = [(s − p)·F(s)] at s = p. Final value theorem: f(∞) = lims→0 s·F(s), valid only when all poles of s·F(s) lie in the left half-plane. Initial value theorem: f(0⁺) = lims→∞ s·F(s).
Transform the equation
Y(s) = 25/(s(s + 1)(s + 5))
Partial fractions
A = 25/(1·5) = 5
B = 25/((−1)·4) = −6.25
C = 25/((−5)·(−4)) = 1.25
Output
y(t) = 5 − 6.25·e−t + 1.25·e−5t
y(0.4) = 0.9797
Answer
y(0.4) = 0.9797
3.Block diagrams
Answer: K = 1
Block-diagram algebra: blocks in series multiply (G₁·G₂), blocks in parallel add (G₁ + G₂), and a loop with forward path G and feedback path H reduces to T = G/(1 + G·H) for negative feedback and G/(1 − G·H) for positive feedback. Reduce inner loops first, then work outwards. The closed-loop poles are the roots of the characteristic equation 1 + G(s)H(s) = 0. For a stable loop, a step input of size A gives the steady-state output A·T(0); with unity feedback the steady-state error to a step is A/(1 + Kp) with Kp = G(0).
A quadratic s² + βs + γ has a double root when β² = 4γ.
18² = 4(80 + K) → K = 324/4 − 80 = 1
Answer
K = 1
Both closed-loop poles are then at s = −9.
4.Block diagrams
Answer: css = 1.95
Block-diagram algebra: blocks in series multiply (G₁·G₂), blocks in parallel add (G₁ + G₂), and a loop with forward path G and feedback path H reduces to T = G/(1 + G·H) for negative feedback and G/(1 − G·H) for positive feedback. Reduce inner loops first, then work outwards. The closed-loop poles are the roots of the characteristic equation 1 + G(s)H(s) = 0. For a stable loop, a step input of size A gives the steady-state output A·T(0); with unity feedback the steady-state error to a step is A/(1 + Kp) with Kp = G(0).
Transfer functions
C/D = G/(1 + K·G) = 4/(s + 7 + 112)
C/R = K·G/(1 + K·G) = 112/(s + 7 + 112)
Steady state
css = 2·112/119 + 2·4/119 = 1.95
Answer
css = 1.95
A larger K reduces the effect of the disturbance, but never to zero with a proportional controller.
5.Step response
Answer: tp = 0.3958 s
Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).
Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).
Routh–Hurwitz criterion: a linear system is stable when every root of its characteristic polynomial lies in the left half of the s-plane. Write the coefficients alternately into the first two rows of the Routh array. Each entry of a new row comes from the two rows above it; for a cubic a₃s³ + a₂s² + a₁s + a₀ the s¹ entry is b₁ = (a₂·a₁ − a₃·a₀)/a₂. The number of sign changes in the first column equals the number of roots in the right half-plane. With a gain K in the coefficients, every first-column entry must stay positive: the gain that makes the s¹ entry zero is the stability limit, and the s² row then gives the frequency of the sustained oscillation.
For s² + c₁s + c₀ all roots lie in the left half-plane exactly when c₁ > 0 and c₀ > 0.
-2 + K > 0 → K > 2
5K − 8 > 0 → K > 1.6
Kmin = 2
Answer
Kmin = 2
8.Stability: Routh–Hurwitz & root locus
Answer: θd = 18.43 °
Root locus: as the gain K goes from 0 to ∞, the closed-loop poles, the roots of 1 + K·G(s) = 0, move from the open-loop poles to the open-loop zeros or to infinity. A point on the real axis belongs to the locus when the number of real poles and zeros to its right is odd. The n − m branches that go to infinity follow asymptotes at the angles (2q + 1)·180°/(n − m), which start from the centroid σₐ = (Σ poles − Σ zeros)/(n − m). Branches leave or join the real axis where dK/ds = 0. The angle condition ∠G(s) = 180° fixes the shape, and the magnitude condition K = 1/|G(s)| gives the gain at any point of the locus.
Pole locations
s² + 2s + 10 = 0 → s = −1 ± j3
s = −2
Angles from the other poles
∠(−1 + j3 + 2) = atan2(3, 1) = 71.57°
∠(−1 + j3 − (−1 − j3)) = ∠(j6) = 90°
Angle of departure
θd = 180° − 71.57° − 90° = 18.43°
Answer
θd = 18.43°
9.Steady-state error & PID control
Answer: K = 20
Steady-state error: in a unity-feedback loop with open-loop transfer function G(s) the error is E(s) = R(s)/(1 + G(s)), and by the final value theorem ess = lims→0 s·E(s). The system type is the number of poles of G(s) at s = 0. The error constants are Kp = lim G(s), Kv = lim s·G(s) and Ka = lim s²·G(s), all for s → 0. A step of size A gives ess = A/(1 + Kp), a ramp A·t gives A/Kv and a parabola A·t²/2 gives A/Ka. A type-0 loop follows a step with a finite error, a type-1 loop follows it exactly and a ramp with a finite error.
Required velocity constant
Kv = A/ess = 2/0.1 = 20
Gain
K = 1·Kv = 20
Answer
K = 20
A large gain makes this loop very lightly damped: ζ = 0.1118. That conflict is why compensators are used.
10.Steady-state error & PID control
Answer: %OS = 8.084 %
P, PI and PID control: the controller C(s) = Kp + Ki/s + Kd·s acts on the error. A proportional gain makes the loop faster and reduces the error of a type-0 plant, but never removes it. The integral term adds a pole at s = 0: the system type rises by one, and a step is followed without error. The derivative term adds damping. To choose gains, write the closed-loop characteristic polynomial and compare it with s² + 2ζωns + ωn². Then %OS = 100·e−ζπ/√(1−ζ²), tp = π/ωd with ωd = ωn√(1 − ζ²), and ts ≈ 4/(ζωn).
Characteristic polynomial
s(s + 10) + 16·4 = s² + 10s + 64
ωₙ and ζ
ωₙ = √64 = 8 rad/s
ζ = 10/(2·8) = 0.625
Overshoot
%OS = 100·e−0.625π/√(1 − 0.625²) = 8.084 %
Answer
%OS = 8.084 %
11.Bode plots & margins
Answer: f0 = 1517 Hz
Frequency response: substitute s = jω in the transfer function. The magnitude in decibels is 20·log₁₀|H(jω)| and the phase is the sum of the angles of the numerator factors minus those of the denominator factors. A first-order RC or RL filter has its corner (−3 dB) frequency at ωc = 1/(RC) or R/L, and fc = ωc/(2π); a low-pass filter gives |H| = 1/√(1 + (ω/ωc)²) and φ = −atan(ω/ωc). In the asymptotic (straight-line) Bode plot each pole bends the magnitude down by 20 dB/decade at its corner frequency, each zero bends it up by 20 dB/decade, and an integrator 1/s gives −20 dB/decade at all frequencies. Gain crossover ωc: |L(jω)| = 1 (0 dB); phase margin PM = 180° + ∠L(jωc). Phase crossover ω180: ∠L(jω) = −180°; gain margin GM = −20·log₁₀|L(jω180)| dB. The closed loop is stable when both margins are positive.
Resonant frequency
ω₀ = 1/√(LC) = 1/√(0.05·2.2 × 10⁻⁷) = 9535 rad/s
f₀ = ω₀/(2π) = 1517 Hz
Answer
f0 = 1517 Hz
12.Bode plots & margins
Answer: GM = 9.542 dB
Frequency response: substitute s = jω in the transfer function. The magnitude in decibels is 20·log₁₀|H(jω)| and the phase is the sum of the angles of the numerator factors minus those of the denominator factors. A first-order RC or RL filter has its corner (−3 dB) frequency at ωc = 1/(RC) or R/L, and fc = ωc/(2π); a low-pass filter gives |H| = 1/√(1 + (ω/ωc)²) and φ = −atan(ω/ωc). In the asymptotic (straight-line) Bode plot each pole bends the magnitude down by 20 dB/decade at its corner frequency, each zero bends it up by 20 dB/decade, and an integrator 1/s gives −20 dB/decade at all frequencies. Gain crossover ωc: |L(jω)| = 1 (0 dB); phase margin PM = 180° + ∠L(jωc). Phase crossover ω180: ∠L(jω) = −180°; gain margin GM = −20·log₁₀|L(jω180)| dB. The closed loop is stable when both margins are positive.