In the print window, choose “Save as PDF” to keep a copy on your device.
1Formulas and methods
Stability: Routh–Hurwitz & root locus
Stability
all roots of the characteristic polynomial in the left half-plane
Routh array, s¹ entry of a cubic
b1 = (a2a1 − a3a0)/a2
Right half-plane roots
number of sign changes in the first column
Cubic s³ + a₂s² + a₁s + a₀
stable when all a > 0 and a₂·a₁ > a₀
K/(s(s + a)(s + b))
Kmax = ab(a + b), ω = √(ab)
Characteristic equation
1 + K·G(s) = 0
Asymptotes
σa = (Σp − Σz)/(n − m), θ = (2q + 1)·180°/(n − m)
Break-away and break-in points
dK/ds = 0
Magnitude condition
K = 1/|G(s)|
Angle of departure
θd = 180° − Σ∠(from other poles) + Σ∠(from zeros)
Method
Write the closed-loop characteristic polynomial: the denominator of 1 + K·G(s) = 0, multiplied out.
Put the coefficients alternately into the first two rows of the Routh array and build the remaining rows.
Count the sign changes in the first column: each one is a pole in the right half-plane. With K in the array, demand that every first-column entry stays positive.
For a root locus, mark the poles and zeros, the real-axis segments, the asymptotes from the centroid and the break points where dK/ds = 0. Use K = 1/|G(s)| for the gain at a point.
Steady-state error & PID control
System type
number of poles of G(s) at s = 0
Error constants
Kp = lim G(s), Kv = lim s·G(s), Ka = lim s²·G(s) (s → 0)
Step A
ess = A/(1 + Kp)
Ramp A·t
ess = A/Kv
Parabola A·t²/2
ess = A/Ka
PID controller
C(s) = Kp + Ki/s + Kd·s
Second-order target
s² + 2ζωns + ωn²
Overshoot and timing
%OS = 100·e−ζπ/√(1−ζ²), tp = π/ωd, ts ≈ 4/(ζωn)
Method
Count the poles of the open loop C(s)·G(s) at s = 0: that is the system type.
Work out the error constant that matches the input: Kp for a step, Kv for a ramp, Ka for a parabola.
Apply ess = A/(1 + Kp), A/Kv or A/Ka, or solve it for the gain you need.
For a damping or speed specification, write the closed-loop characteristic polynomial and match it with s² + 2ζω_n·s + ω_n².
2Practice problems
1.Laplace transformsMedium
Find f(t) for F(s) = (5s + 8)/(s² + 6s + 10) by completing the square, and evaluate f(0.3).
F(s) = (5s + 8)/(s² + 6s + 10)t = 0.3 s
f(0.3) =
2.Laplace transformsHard
A system obeys y″ + 4y′ + 3y = 3·u(t), with y(0) = 3 and y′(0) = 0. At t = 0 a step input u(t) = 5 is applied. Use the Laplace transform to find y(0.5).
A plant G(s) = 39/(s + 8) is controlled in a negative feedback loop whose sensor has the gain H = 0.5. Find the time constant τ of the closed loop.
G(s) = 39/(s + 8)H = 0.5
τ = s
4.Block diagramsHard
The plant G(s) = K/(s(s + 2)(s + 5)) is in a unity negative feedback loop. At the largest stable gain the loop oscillates. Find the frequency of oscillation ω in rad/s.
G(s) = K/(s(s + 2)(s + 5))unity negative feedback
ω = rad/s
5.Step responseMedium
A system has the transfer function G(s) = 94/(s² + 14s + 94) and receives a unit step input. Find the percent overshoot %OS of the step response.
G(s) = 94/(s² + 14s + 94)
%OS = %
6.Step responseHard
The step response of a second-order system without zeros shows 20 % overshoot, and the first peak occurs at t = 0.5 s. Find the natural frequency ωn.
%OS = 20 %tp = 0.5 s
ωn = rad/s
7.Stability: Routh–Hurwitz & root locusMedium
A unity-feedback loop has L(s) = K(s + 11)/(s(s + 2)(s + 3)), with K > 0. Find the largest gain Kmax for which the closed loop is stable.
L(s) = K(s + 11)/(s(s + 2)(s + 3))
Kmax =
8.Stability: Routh–Hurwitz & root locusHard
The root locus of L(s) = K/((s + 1)(s + 2)(s + 3)) is sketched. Find the frequency ω at which the locus crosses the imaginary axis.
L(s) = K/((s + 1)(s + 2)(s + 3))
ω = rad/s
9.Steady-state error & PID controlMedium
A unity-feedback loop with G(s) = K/(s(s + 10)) must follow the ramp r(t) = 10t with a steady-state error of 0.2. Find the gain K.
G(s) = K/(s(s + 10))r(t) = 10tess = 0.2
K =
10.Steady-state error & PID controlHard
A proportional controller K = 10 drives the plant G(s) = 1/(s(s + 2)) in a unity-feedback loop. Find the peak time tp of the step response.
G(s) = 1/(s(s + 2))K = 10
tp = s
11.Bode plots & marginsMedium
In the series RLC band-pass filter shown the output is taken across R = 5 Ω, with L = 1 mH and C = 0.1 µF. Find the quality factor Q.
R = 5 ΩL = 1 mHC = 0.1 µF
Q =
12.Bode plots & marginsHard
A unity-feedback loop has the open-loop transfer function L(s) = K/(s(s + 1)(s + 4)). Find the gain K that gives a gain margin of 2 dB.
L(s) = K/(s(s + 1)(s + 4))GM = 2 dB
K =
3Solutions
1.Laplace transforms
Answer: f(0.3) = 1.101
Laplace transform: F(s) = ∫₀∞ f(t)·e−st dt turns derivatives into multiplications by s: ℒ{f′} = sF(s) − f(0), ℒ{f″} = s²F(s) − s·f(0) − f′(0). Standard pairs: 1 ↔ 1/s, e−at ↔ 1/(s + a), t·e−at ↔ 1/(s + a)², sin ωt ↔ ω/(s² + ω²), cos ωt ↔ s/(s² + ω²), and a shift s → s + σ multiplies the time function by e−σt. To invert a rational F(s), split it into partial fractions: the residue of a simple pole p is A = [(s − p)·F(s)] at s = p. Final value theorem: f(∞) = lims→0 s·F(s), valid only when all poles of s·F(s) lie in the left half-plane. Initial value theorem: f(0⁺) = lims→∞ s·F(s).
Laplace transform: F(s) = ∫₀∞ f(t)·e−st dt turns derivatives into multiplications by s: ℒ{f′} = sF(s) − f(0), ℒ{f″} = s²F(s) − s·f(0) − f′(0). Standard pairs: 1 ↔ 1/s, e−at ↔ 1/(s + a), t·e−at ↔ 1/(s + a)², sin ωt ↔ ω/(s² + ω²), cos ωt ↔ s/(s² + ω²), and a shift s → s + σ multiplies the time function by e−σt. To invert a rational F(s), split it into partial fractions: the residue of a simple pole p is A = [(s − p)·F(s)] at s = p. Final value theorem: f(∞) = lims→0 s·F(s), valid only when all poles of s·F(s) lie in the left half-plane. Initial value theorem: f(0⁺) = lims→∞ s·F(s).
Transform the equation
(s² + 4s + 3)·Y(s) = 3s + 12 + 15/s
Y(s) = (3s² + 12s + 15)/(s(s + 1)(s + 3))
Partial fractions
A = 15/(1·3) = 5
B = 6/((−1)·2) = −3
C = 6/((−3)·(−2)) = 1
Result
y(t) = 5 − 3·e−t + e−3t
y(0.5) = 3.404
Answer
y(0.5) = 3.404
Check: y(0) = A + B + C = 3.
3.Block diagrams
Answer: τ = 0.03636 s
Block-diagram algebra: blocks in series multiply (G₁·G₂), blocks in parallel add (G₁ + G₂), and a loop with forward path G and feedback path H reduces to T = G/(1 + G·H) for negative feedback and G/(1 − G·H) for positive feedback. Reduce inner loops first, then work outwards. The closed-loop poles are the roots of the characteristic equation 1 + G(s)H(s) = 0. For a stable loop, a step input of size A gives the steady-state output A·T(0); with unity feedback the steady-state error to a step is A/(1 + Kp) with Kp = G(0).
Block-diagram algebra: blocks in series multiply (G₁·G₂), blocks in parallel add (G₁ + G₂), and a loop with forward path G and feedback path H reduces to T = G/(1 + G·H) for negative feedback and G/(1 − G·H) for positive feedback. Reduce inner loops first, then work outwards. The closed-loop poles are the roots of the characteristic equation 1 + G(s)H(s) = 0. For a stable loop, a step input of size A gives the steady-state output A·T(0); with unity feedback the steady-state error to a step is A/(1 + Kp) with Kp = G(0).
Characteristic equation
s³ + 7s² + 10s + K = 0
Routh array
s³ | 1 10
s² | 7 K
s¹ | (7·10 − K)/7
s⁰ | K
Stability limit
All entries of the first column must be positive.
Kmax = 7·10 = 70
Frequency of oscillation
7·(jω)² + 70 = 0 → ω² = 70/7 = 10
ω = 3.162 rad/s
Answer
ω = 3.162 rad/s
5.Step response
Answer: %OS = 3.769 %
Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).
Compare with the standard form
The denominator must match s² + 2ζωₙs + ωₙ².
ωₙ² = 94 → ωₙ = 9.695 rad/s
2ζωₙ = 14 → ζ = 14/(2·9.695) = 0.722
Result
%OS = 100·e−ζπ/√(1−ζ²) = 100·e−3.278 = 3.769 %
Answer
%OS = 3.769 %
6.Step response
Answer: ωn = 7.06 rad/s
Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).
Routh–Hurwitz criterion: a linear system is stable when every root of its characteristic polynomial lies in the left half of the s-plane. Write the coefficients alternately into the first two rows of the Routh array. Each entry of a new row comes from the two rows above it; for a cubic a₃s³ + a₂s² + a₁s + a₀ the s¹ entry is b₁ = (a₂·a₁ − a₃·a₀)/a₂. The number of sign changes in the first column equals the number of roots in the right half-plane. With a gain K in the coefficients, every first-column entry must stay positive: the gain that makes the s¹ entry zero is the stability limit, and the s² row then gives the frequency of the sustained oscillation.
With the zero to the right of s = −5 the loop would stay stable for every K > 0.
8.Stability: Routh–Hurwitz & root locus
Answer: ω = 3.317 rad/s
Root locus: as the gain K goes from 0 to ∞, the closed-loop poles, the roots of 1 + K·G(s) = 0, move from the open-loop poles to the open-loop zeros or to infinity. A point on the real axis belongs to the locus when the number of real poles and zeros to its right is odd. The n − m branches that go to infinity follow asymptotes at the angles (2q + 1)·180°/(n − m), which start from the centroid σₐ = (Σ poles − Σ zeros)/(n − m). Branches leave or join the real axis where dK/ds = 0. The angle condition ∠G(s) = 180° fixes the shape, and the magnitude condition K = 1/|G(s)| gives the gain at any point of the locus.
Critical gain
s³ + 6s² + 11s + 6 + K = 0
s¹: (6·11 − 6 − K)/6 = 0 → K = 60
Crossing frequency
6s² + 6 + 60 = 6s² + 66 = 0 → s² = −11
ω = √11 = 3.317 rad/s
Answer
ω = 3.317 rad/s
9.Steady-state error & PID control
Answer: K = 500
Steady-state error: in a unity-feedback loop with open-loop transfer function G(s) the error is E(s) = R(s)/(1 + G(s)), and by the final value theorem ess = lims→0 s·E(s). The system type is the number of poles of G(s) at s = 0. The error constants are Kp = lim G(s), Kv = lim s·G(s) and Ka = lim s²·G(s), all for s → 0. A step of size A gives ess = A/(1 + Kp), a ramp A·t gives A/Kv and a parabola A·t²/2 gives A/Ka. A type-0 loop follows a step with a finite error, a type-1 loop follows it exactly and a ramp with a finite error.
Required velocity constant
Kv = A/ess = 10/0.2 = 50
Gain
K = 10·Kv = 500
Answer
K = 500
A large gain makes this loop very lightly damped: ζ = 0.2236. That conflict is why compensators are used.
10.Steady-state error & PID control
Answer: tp = 1.047 s
P, PI and PID control: the controller C(s) = Kp + Ki/s + Kd·s acts on the error. A proportional gain makes the loop faster and reduces the error of a type-0 plant, but never removes it. The integral term adds a pole at s = 0: the system type rises by one, and a step is followed without error. The derivative term adds damping. To choose gains, write the closed-loop characteristic polynomial and compare it with s² + 2ζωns + ωn². Then %OS = 100·e−ζπ/√(1−ζ²), tp = π/ωd with ωd = ωn√(1 − ζ²), and ts ≈ 4/(ζωn).
Characteristic polynomial
s(s + 2) + 10·1 = s² + 2s + 10
ωₙ and ζ
ωₙ = √10 = 3.162 rad/s
ζ = 2/(2·3.162) = 0.3162
Peak time
ωd = 3.162·√(1 − 0.3162²) = 3 rad/s
tp = π/3 = 1.047 s
Answer
tp = 1.047 s
11.Bode plots & margins
Answer: Q = 20
Frequency response: substitute s = jω in the transfer function. The magnitude in decibels is 20·log₁₀|H(jω)| and the phase is the sum of the angles of the numerator factors minus those of the denominator factors. A first-order RC or RL filter has its corner (−3 dB) frequency at ωc = 1/(RC) or R/L, and fc = ωc/(2π); a low-pass filter gives |H| = 1/√(1 + (ω/ωc)²) and φ = −atan(ω/ωc). In the asymptotic (straight-line) Bode plot each pole bends the magnitude down by 20 dB/decade at its corner frequency, each zero bends it up by 20 dB/decade, and an integrator 1/s gives −20 dB/decade at all frequencies. Gain crossover ωc: |L(jω)| = 1 (0 dB); phase margin PM = 180° + ∠L(jωc). Phase crossover ω180: ∠L(jω) = −180°; gain margin GM = −20·log₁₀|L(jω180)| dB. The closed loop is stable when both margins are positive.
Resonant frequency
ω₀ = 1/√(LC) = 1/√(0.001·1 × 10⁻⁷) = 100000 rad/s
f₀ = ω₀/(2π) = 15915 Hz
Quality factor
BW = R/L = 5/0.001 = 5000 rad/s = 795.8 Hz
Q = ω₀/BW = 100000/5000 = 20
Answer
Q = 20
12.Bode plots & margins
Answer: K = 15.89
Frequency response: substitute s = jω in the transfer function. The magnitude in decibels is 20·log₁₀|H(jω)| and the phase is the sum of the angles of the numerator factors minus those of the denominator factors. A first-order RC or RL filter has its corner (−3 dB) frequency at ωc = 1/(RC) or R/L, and fc = ωc/(2π); a low-pass filter gives |H| = 1/√(1 + (ω/ωc)²) and φ = −atan(ω/ωc). In the asymptotic (straight-line) Bode plot each pole bends the magnitude down by 20 dB/decade at its corner frequency, each zero bends it up by 20 dB/decade, and an integrator 1/s gives −20 dB/decade at all frequencies. Gain crossover ωc: |L(jω)| = 1 (0 dB); phase margin PM = 180° + ∠L(jωc). Phase crossover ω180: ∠L(jω) = −180°; gain margin GM = −20·log₁₀|L(jω180)| dB. The closed loop is stable when both margins are positive.