1Formulas and methods
Stability: Routh–Hurwitz & root locus
Stability
all roots of the characteristic polynomial in the left half-plane
Routh array, s¹ entry of a cubic
b1 = (a2a1 − a3a0)/a2
Right half-plane roots
number of sign changes in the first column
Cubic s³ + a₂s² + a₁s + a₀
stable when all a > 0 and a₂·a₁ > a₀
K/(s(s + a)(s + b))
Kmax = ab(a + b), ω = √(ab)
Characteristic equation
1 + K·G(s) = 0
Asymptotes
σa = (Σp − Σz)/(n − m), θ = (2q + 1)·180°/(n − m)
Break-away and break-in points
dK/ds = 0
Magnitude condition
K = 1/|G(s)|
Angle of departure
θd = 180° − Σ∠(from other poles) + Σ∠(from zeros)
Method
Write the closed-loop characteristic polynomial: the denominator of 1 + K·G(s) = 0, multiplied out.
Put the coefficients alternately into the first two rows of the Routh array and build the remaining rows.
Count the sign changes in the first column: each one is a pole in the right half-plane. With K in the array, demand that every first-column entry stays positive.
For a root locus, mark the poles and zeros, the real-axis segments, the asymptotes from the centroid and the break points where dK/ds = 0. Use K = 1/|G(s)| for the gain at a point.
Steady-state error & PID control
System type
number of poles of G(s) at s = 0
Error constants
Kp = lim G(s), Kv = lim s·G(s), Ka = lim s²·G(s) (s → 0)
Step A
ess = A/(1 + Kp)
Ramp A·t
ess = A/Kv
Parabola A·t²/2
ess = A/Ka
PID controller
C(s) = Kp + Ki/s + Kd·s
Second-order target
s² + 2ζωns + ωn²
Overshoot and timing
%OS = 100·e−ζπ/√(1−ζ²), tp = π/ωd, ts ≈ 4/(ζωn)
Method
Count the poles of the open loop C(s)·G(s) at s = 0: that is the system type.
Work out the error constant that matches the input: Kp for a step, Kv for a ramp, Ka for a parabola.
Apply ess = A/(1 + Kp), A/Kv or A/Ka, or solve it for the gain you need.
For a damping or speed specification, write the closed-loop characteristic polynomial and match it with s² + 2ζω_n·s + ω_n².
2Practice problems
1.Laplace transformsMedium
F(s) = (5s + 10)/(s² + 4s + 3). Its inverse transform has the form f(t) = A·e−t + B·e−3t. Find the coefficient A by partial fractions.
F(s) = (5s + 10)/(s² + 4s + 3)
A =
2.Laplace transformsHard
A system is described by the differential equation y″ + 6y′ + 5y = 2u′ + 19u, with input u(t) and output y(t). Find its transfer function G(s) = Y(s)/U(s) (zero initial conditions) and evaluate the impulse response g(t) at t = 1.5 s. Find g(1.5).
y″ + 6y′ + 5y = 2u′ + 19ut = 1.5 s
g(1.5) =
3.Block diagramsMedium
The plant G(s) = 6/(s + 3) has an inner (minor) negative feedback loop with gain H₁ = 1. A controller gain K = 20 and an outer unity negative feedback loop close the system. Find the closed-loop pole p.
G(s) = 6/(s + 3)H₁ = 1K = 20
p =
4.Block diagramsHard
Reduce the block diagram with G₁ = 14/(s + 1), G₂ = 3/(s + 7), an inner negative feedback H₁ = 1 around G₂ and an outer negative feedback H₂ = 0.5. Find the DC gain T(0) of C(s)/R(s).
G₁ = 14/(s + 1)G₂ = 3/(s + 7)H₁ = 1H₂ = 0.5
T(0) =
5.Step responseMedium
A system has the transfer function G(s) = 31.5/(s² + 4s + 63) and receives a unit step input. Find the peak time tp of the step response.
G(s) = 31.5/(s² + 4s + 63)
tp = s
6.Step responseHard
The step response of a second-order system without zeros shows 30 % overshoot, and the first peak occurs at t = 1 s. Find the natural frequency ωn.
%OS = 30 %tp = 1 s
ωn = rad/s
7.Stability: Routh–Hurwitz & root locusMedium
The loop in the diagram runs with K = 7.5 and L(s) = K/(s(s + 2)(s + 3)). By what factor m can the gain be raised before the closed loop becomes unstable?
L(s) = K/(s(s + 2)(s + 3))K = 7.5
m =
8.Stability: Routh–Hurwitz & root locusHard
For the loop L(s) = K/(s(s + 2)(s + 5)), find the gain K that puts a closed-loop pole at s = −1.
L(s) = K/(s(s + 2)(s + 5))s = −1
K =
9.Steady-state error & PID controlMedium
A process G(s) = 0.5/(10s + 1) is controlled by a proportional gain K = 10 in a unity-feedback loop. Find the steady-state error ess for a step, as a percentage of the step size.
G(s) = 0.5/(10s + 1)K = 10
ess = %
10.Steady-state error & PID controlHard
A proportional controller K = 40 drives the plant G(s) = 10/(s(s + 8)) in a unity-feedback loop. Find the peak time tp of the step response.
G(s) = 10/(s(s + 8))K = 40
tp = s
11.Bode plots & marginsMedium
The RC low-pass filter shown has R = 3.3 kΩ, C = 4.7 nF. A sinusoidal input of 31 kHz is applied. Find the phase shift φ of vout relative to vin, in degrees.
R = 3.3 kΩC = 4.7 nFf = 31 kHz
φ = °
12.Bode plots & marginsHard
A unity-feedback loop has the open-loop transfer function L(s) = K/(s(s + 1)(s + 7)). Find the gain K that gives a gain margin of 15 dB.
L(s) = K/(s(s + 1)(s + 7))GM = 15 dB
K =
3Solutions
1.Laplace transforms
Answer: A = 2.5
Laplace transform: F(s) = ∫₀∞ f(t)·e−st dt turns derivatives into multiplications by s: ℒ{f′} = sF(s) − f(0), ℒ{f″} = s²F(s) − s·f(0) − f′(0). Standard pairs: 1 ↔ 1/s, e−at ↔ 1/(s + a), t·e−at ↔ 1/(s + a)², sin ωt ↔ ω/(s² + ω²), cos ωt ↔ s/(s² + ω²), and a shift s → s + σ multiplies the time function by e−σt. To invert a rational F(s), split it into partial fractions: the residue of a simple pole p is A = [(s − p)·F(s)] at s = p. Final value theorem: f(∞) = lims→0 s·F(s), valid only when all poles of s·F(s) lie in the left half-plane. Initial value theorem: f(0⁺) = lims→∞ s·F(s).
Factor the denominator
s² + 4s + 3 = (s + 1)(s + 3)
F(s) = A/(s + 1) + B/(s + 3)
Cover-up rule
Multiply by (s + 1) and set s = −1: the B-term vanishes.
A = (5s + 10)/(s + 3) |s = −1 = 5/2 = 2.5
Answer
A = 2.5
(B = 2.5, so f(t) = 2.5·e−t + 2.5·e−3t)
2.Laplace transforms
Answer: g(1.5) = 0.9471
Laplace transform: F(s) = ∫₀∞ f(t)·e−st dt turns derivatives into multiplications by s: ℒ{f′} = sF(s) − f(0), ℒ{f″} = s²F(s) − s·f(0) − f′(0). Standard pairs: 1 ↔ 1/s, e−at ↔ 1/(s + a), t·e−at ↔ 1/(s + a)², sin ωt ↔ ω/(s² + ω²), cos ωt ↔ s/(s² + ω²), and a shift s → s + σ multiplies the time function by e−σt. To invert a rational F(s), split it into partial fractions: the residue of a simple pole p is A = [(s − p)·F(s)] at s = p. Final value theorem: f(∞) = lims→0 s·F(s), valid only when all poles of s·F(s) lie in the left half-plane. Initial value theorem: f(0⁺) = lims→∞ s·F(s).
Transfer function
G(s) = Y(s)/U(s) = (2s + 19)/(s² + 6s + 5)
Partial fractions
s² + 6s + 5 = (s + 1)(s + 5)
A = 4.25, B = −2.25
Impulse response
g(t) = 4.25·e−t − 2.25·e−5t
g(1.5) = 0.9471
Answer
g(1.5) = 0.9471
3.Block diagrams
Answer: p = −129
Block-diagram algebra: blocks in series multiply (G₁·G₂), blocks in parallel add (G₁ + G₂), and a loop with forward path G and feedback path H reduces to T = G/(1 + G·H) for negative feedback and G/(1 − G·H) for positive feedback. Reduce inner loops first, then work outwards. The closed-loop poles are the roots of the characteristic equation 1 + G(s)H(s) = 0. For a stable loop, a step input of size A gives the steady-state output A·T(0); with unity feedback the steady-state error to a step is A/(1 + Kp) with Kp = G(0).
Block-diagram algebra: blocks in series multiply (G₁·G₂), blocks in parallel add (G₁ + G₂), and a loop with forward path G and feedback path H reduces to T = G/(1 + G·H) for negative feedback and G/(1 − G·H) for positive feedback. Reduce inner loops first, then work outwards. The closed-loop poles are the roots of the characteristic equation 1 + G(s)H(s) = 0. For a stable loop, a step input of size A gives the steady-state output A·T(0); with unity feedback the steady-state error to a step is A/(1 + Kp) with Kp = G(0).
Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).
Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).
Routh–Hurwitz criterion: a linear system is stable when every root of its characteristic polynomial lies in the left half of the s-plane. Write the coefficients alternately into the first two rows of the Routh array. Each entry of a new row comes from the two rows above it; for a cubic a₃s³ + a₂s² + a₁s + a₀ the s¹ entry is b₁ = (a₂·a₁ − a₃·a₀)/a₂. The number of sign changes in the first column equals the number of roots in the right half-plane. With a gain K in the coefficients, every first-column entry must stay positive: the gain that makes the s¹ entry zero is the stability limit, and the s² row then gives the frequency of the sustained oscillation.
Routh array
s³ + 5s² + 6s + K = 0
s³: 1, 6
s²: 5, K
s¹: (5·6 − K)/5
s⁰: K
Largest stable gain
Kmax = 5·6 = 30
Factor
m = 30/7.5 = 4
Answer
m = 4
This factor is the gain margin as a ratio: 12.04 dB.
8.Stability: Routh–Hurwitz & root locus
Answer: K = 4
Root locus: as the gain K goes from 0 to ∞, the closed-loop poles, the roots of 1 + K·G(s) = 0, move from the open-loop poles to the open-loop zeros or to infinity. A point on the real axis belongs to the locus when the number of real poles and zeros to its right is odd. The n − m branches that go to infinity follow asymptotes at the angles (2q + 1)·180°/(n − m), which start from the centroid σₐ = (Σ poles − Σ zeros)/(n − m). Branches leave or join the real axis where dK/ds = 0. The angle condition ∠G(s) = 180° fixes the shape, and the magnitude condition K = 1/|G(s)| gives the gain at any point of the locus.
Magnitude condition
K = |s|·|s + 2|·|s + 5|
Evaluate at the point
K = 1·1·4 = 4
Answer
K = 4
Check: s(s + 2)(s + 5) + K is zero at s = −1.
9.Steady-state error & PID control
Answer: ess = 16.67 %
Steady-state error: in a unity-feedback loop with open-loop transfer function G(s) the error is E(s) = R(s)/(1 + G(s)), and by the final value theorem ess = lims→0 s·E(s). The system type is the number of poles of G(s) at s = 0. The error constants are Kp = lim G(s), Kv = lim s·G(s) and Ka = lim s²·G(s), all for s → 0. A step of size A gives ess = A/(1 + Kp), a ramp A·t gives A/Kv and a parabola A·t²/2 gives A/Ka. A type-0 loop follows a step with a finite error, a type-1 loop follows it exactly and a ramp with a finite error.
Position constant
Kp = 10·0.5 = 5
Step error
ess = 100/(1 + 5) = 16.67 %
Answer
ess = 16.67 %
10.Steady-state error & PID control
Answer: tp = 0.1603 s
P, PI and PID control: the controller C(s) = Kp + Ki/s + Kd·s acts on the error. A proportional gain makes the loop faster and reduces the error of a type-0 plant, but never removes it. The integral term adds a pole at s = 0: the system type rises by one, and a step is followed without error. The derivative term adds damping. To choose gains, write the closed-loop characteristic polynomial and compare it with s² + 2ζωns + ωn². Then %OS = 100·e−ζπ/√(1−ζ²), tp = π/ωd with ωd = ωn√(1 − ζ²), and ts ≈ 4/(ζωn).
Characteristic polynomial
s(s + 8) + 40·10 = s² + 8s + 400
ωₙ and ζ
ωₙ = √400 = 20 rad/s
ζ = 8/(2·20) = 0.2
Peak time
ωd = 20·√(1 − 0.2²) = 19.6 rad/s
tp = π/19.6 = 0.1603 s
Answer
tp = 0.1603 s
11.Bode plots & margins
Answer: φ = −71.68 °
Frequency response: substitute s = jω in the transfer function. The magnitude in decibels is 20·log₁₀|H(jω)| and the phase is the sum of the angles of the numerator factors minus those of the denominator factors. A first-order RC or RL filter has its corner (−3 dB) frequency at ωc = 1/(RC) or R/L, and fc = ωc/(2π); a low-pass filter gives |H| = 1/√(1 + (ω/ωc)²) and φ = −atan(ω/ωc). In the asymptotic (straight-line) Bode plot each pole bends the magnitude down by 20 dB/decade at its corner frequency, each zero bends it up by 20 dB/decade, and an integrator 1/s gives −20 dB/decade at all frequencies. Gain crossover ωc: |L(jω)| = 1 (0 dB); phase margin PM = 180° + ∠L(jωc). Phase crossover ω180: ∠L(jω) = −180°; gain margin GM = −20·log₁₀|L(jω180)| dB. The closed loop is stable when both margins are positive.
Corner frequency
ωc = 1/(RC) = 1/(3300·4.7 × 10⁻⁹) = 64475 rad/s
fc = 10261 Hz → f/fc = 31000/10261 = 3.021
Phase
φ = − atan(3.021) = −71.68°
Answer
φ = −71.68°
12.Bode plots & margins
Answer: K = 9.958
Frequency response: substitute s = jω in the transfer function. The magnitude in decibels is 20·log₁₀|H(jω)| and the phase is the sum of the angles of the numerator factors minus those of the denominator factors. A first-order RC or RL filter has its corner (−3 dB) frequency at ωc = 1/(RC) or R/L, and fc = ωc/(2π); a low-pass filter gives |H| = 1/√(1 + (ω/ωc)²) and φ = −atan(ω/ωc). In the asymptotic (straight-line) Bode plot each pole bends the magnitude down by 20 dB/decade at its corner frequency, each zero bends it up by 20 dB/decade, and an integrator 1/s gives −20 dB/decade at all frequencies. Gain crossover ωc: |L(jω)| = 1 (0 dB); phase margin PM = 180° + ∠L(jωc). Phase crossover ω180: ∠L(jω) = −180°; gain margin GM = −20·log₁₀|L(jω180)| dB. The closed loop is stable when both margins are positive.