In the print window, choose “Save as PDF” to keep a copy on your device.
1Formulas and methods
Stability: Routh–Hurwitz & root locus
Stability
all roots of the characteristic polynomial in the left half-plane
Routh array, s¹ entry of a cubic
b1 = (a2a1 − a3a0)/a2
Right half-plane roots
number of sign changes in the first column
Cubic s³ + a₂s² + a₁s + a₀
stable when all a > 0 and a₂·a₁ > a₀
K/(s(s + a)(s + b))
Kmax = ab(a + b), ω = √(ab)
Characteristic equation
1 + K·G(s) = 0
Asymptotes
σa = (Σp − Σz)/(n − m), θ = (2q + 1)·180°/(n − m)
Break-away and break-in points
dK/ds = 0
Magnitude condition
K = 1/|G(s)|
Angle of departure
θd = 180° − Σ∠(from other poles) + Σ∠(from zeros)
Method
Write the closed-loop characteristic polynomial: the denominator of 1 + K·G(s) = 0, multiplied out.
Put the coefficients alternately into the first two rows of the Routh array and build the remaining rows.
Count the sign changes in the first column: each one is a pole in the right half-plane. With K in the array, demand that every first-column entry stays positive.
For a root locus, mark the poles and zeros, the real-axis segments, the asymptotes from the centroid and the break points where dK/ds = 0. Use K = 1/|G(s)| for the gain at a point.
Steady-state error & PID control
System type
number of poles of G(s) at s = 0
Error constants
Kp = lim G(s), Kv = lim s·G(s), Ka = lim s²·G(s) (s → 0)
Step A
ess = A/(1 + Kp)
Ramp A·t
ess = A/Kv
Parabola A·t²/2
ess = A/Ka
PID controller
C(s) = Kp + Ki/s + Kd·s
Second-order target
s² + 2ζωns + ωn²
Overshoot and timing
%OS = 100·e−ζπ/√(1−ζ²), tp = π/ωd, ts ≈ 4/(ζωn)
Method
Count the poles of the open loop C(s)·G(s) at s = 0: that is the system type.
Work out the error constant that matches the input: Kp for a step, Kv for a ramp, Ka for a parabola.
Apply ess = A/(1 + Kp), A/Kv or A/Ka, or solve it for the gain you need.
For a damping or speed specification, write the closed-loop characteristic polynomial and match it with s² + 2ζω_n·s + ω_n².
2Practice problems
1.Laplace transformsMedium
Find f(t) for F(s) = (4s + 19)/(s² + 6s + 45) by completing the square, and evaluate f(0.1).
F(s) = (4s + 19)/(s² + 6s + 45)t = 0.1 s
f(0.1) =
2.Laplace transformsHard
A system obeys y″ + 10y′ + 24y = 144·u(t). It starts at rest (y(0) = 0, y′(0) = 0) and the input is a step u(t) = 10 for t ≥ 0. Use the Laplace transform to find the output y(0.25).
A unity negative feedback loop has G(s) = 52/(s(s + 7)). The reference is a ramp r(t) = 10·t. Find the steady-state error ess.
G(s) = 52/(s(s + 7))r(t) = 10·t
ess =
4.Block diagramsHard
The plant G(s) = 42/(s(s + 11)) is in a negative feedback loop with sensor gain H = 1. The closed-loop poles are complex. Find their real part σ.
G(s) = 42/(s(s + 11))H = 1
σ =
5.Step responseMedium
A system has the transfer function G(s) = 25.5/(s² + 4s + 51) and receives a unit step input. Find the natural frequency ωn in rad/s.
G(s) = 25.5/(s² + 4s + 51)
ωn = rad/s
6.Step responseHard
A unity negative feedback loop has G(s) = 190/(s(s + 4)). Find the 2 % settling time ts of the closed-loop step response, using ts ≈ 4/(ζωₙ).
G(s) = 190/(s(s + 4))
ts = s
7.Stability: Routh–Hurwitz & root locusMedium
A unity-feedback loop has L(s) = K(s + 6)/(s(s + 1)(s + 2)), with K > 0. Find the largest gain Kmax for which the closed loop is stable.
L(s) = K(s + 6)/(s(s + 1)(s + 2))
Kmax =
8.Stability: Routh–Hurwitz & root locusHard
The root locus of L(s) = K(s + 11)/(s(s + 7)) leaves the real axis between s = 0 and s = −7, circles round and joins the real axis again to the left of the zero. Find the break-away point sb.
L(s) = K(s + 11)/(s(s + 7))
sb =
9.Steady-state error & PID controlMedium
The input r(t) = 10 + 3t (a step plus a ramp) is applied to a unity-feedback loop with G(s) = 50(s + 3)/(s(s + 1)(s + 4)). Find the steady-state error ess.
G(s) = 50(s + 3)/(s(s + 1)(s + 4))r(t) = 10 + 3t
ess =
10.Steady-state error & PID controlHard
A proportional controller K = 4 drives the plant G(s) = 5/(s(s + 4)) in a unity-feedback loop. Find the percent overshoot %OS of the step response.
G(s) = 5/(s(s + 4))K = 4
%OS = %
11.Bode plots & marginsMedium
In the series RLC band-pass filter shown the output is taken across R = 10 Ω, with L = 5 mH and C = 0.1 µF. Find the quality factor Q.
R = 10 ΩL = 5 mHC = 0.1 µF
Q =
12.Bode plots & marginsHard
A unity-feedback loop has the open-loop transfer function L(s) = 80/(s(s + 8)). Find the phase margin PM in degrees.
L(s) = 80/(s(s + 8))
PM = °
3Solutions
1.Laplace transforms
Answer: f(0.1) = 2.934
Laplace transform: F(s) = ∫₀∞ f(t)·e−st dt turns derivatives into multiplications by s: ℒ{f′} = sF(s) − f(0), ℒ{f″} = s²F(s) − s·f(0) − f′(0). Standard pairs: 1 ↔ 1/s, e−at ↔ 1/(s + a), t·e−at ↔ 1/(s + a)², sin ωt ↔ ω/(s² + ω²), cos ωt ↔ s/(s² + ω²), and a shift s → s + σ multiplies the time function by e−σt. To invert a rational F(s), split it into partial fractions: the residue of a simple pole p is A = [(s − p)·F(s)] at s = p. Final value theorem: f(∞) = lims→0 s·F(s), valid only when all poles of s·F(s) lie in the left half-plane. Initial value theorem: f(0⁺) = lims→∞ s·F(s).
Laplace transform: F(s) = ∫₀∞ f(t)·e−st dt turns derivatives into multiplications by s: ℒ{f′} = sF(s) − f(0), ℒ{f″} = s²F(s) − s·f(0) − f′(0). Standard pairs: 1 ↔ 1/s, e−at ↔ 1/(s + a), t·e−at ↔ 1/(s + a)², sin ωt ↔ ω/(s² + ω²), cos ωt ↔ s/(s² + ω²), and a shift s → s + σ multiplies the time function by e−σt. To invert a rational F(s), split it into partial fractions: the residue of a simple pole p is A = [(s − p)·F(s)] at s = p. Final value theorem: f(∞) = lims→0 s·F(s), valid only when all poles of s·F(s) lie in the left half-plane. Initial value theorem: f(0⁺) = lims→∞ s·F(s).
Transform the equation
Y(s) = 1440/(s(s + 4)(s + 6))
Partial fractions
A = 1440/(4·6) = 60
B = 1440/((−4)·2) = −180
C = 1440/((−6)·(−2)) = 120
Output
y(t) = 60 − 180·e−4t + 120·e−6t
y(0.25) = 20.56
Answer
y(0.25) = 20.56
3.Block diagrams
Answer: ess = 1.346
Block-diagram algebra: blocks in series multiply (G₁·G₂), blocks in parallel add (G₁ + G₂), and a loop with forward path G and feedback path H reduces to T = G/(1 + G·H) for negative feedback and G/(1 − G·H) for positive feedback. Reduce inner loops first, then work outwards. The closed-loop poles are the roots of the characteristic equation 1 + G(s)H(s) = 0. For a stable loop, a step input of size A gives the steady-state output A·T(0); with unity feedback the steady-state error to a step is A/(1 + Kp) with Kp = G(0).
Velocity error constant
Kᵥ = lims→0 s·G(s) = 52/7 = 7.429
Steady-state error
ess = A/Kᵥ = 10/7.429 = 1.346
Answer
ess = 1.346
4.Block diagrams
Answer: σ = −5.5
Block-diagram algebra: blocks in series multiply (G₁·G₂), blocks in parallel add (G₁ + G₂), and a loop with forward path G and feedback path H reduces to T = G/(1 + G·H) for negative feedback and G/(1 − G·H) for positive feedback. Reduce inner loops first, then work outwards. The closed-loop poles are the roots of the characteristic equation 1 + G(s)H(s) = 0. For a stable loop, a step input of size A gives the steady-state output A·T(0); with unity feedback the steady-state error to a step is A/(1 + Kp) with Kp = G(0).
Characteristic equation
s(s + 11) + 42·1 = 0 → s² + 11s + 42 = 0
Roots
s = −5.5 ± j·√(42 − 30.25) = −5.5 ± j3.428
σ = −5.5
Answer
σ = −5.5
5.Step response
Answer: ωn = 7.141 rad/s
Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).
Compare with the standard form
The denominator must match s² + 2ζωₙs + ωₙ².
ωₙ² = 51 → ωₙ = 7.141 rad/s
2ζωₙ = 4 → ζ = 4/(2·7.141) = 0.2801
Result
ωₙ = 7.141 rad/s
Answer
ωn = 7.141 rad/s
6.Step response
Answer: ts = 2 s
Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).
For this loop ζωₙ = a/2 whatever K is: raising K adds overshoot but does not shorten the settling time.
7.Stability: Routh–Hurwitz & root locus
Answer: Kmax = 2
Routh–Hurwitz criterion: a linear system is stable when every root of its characteristic polynomial lies in the left half of the s-plane. Write the coefficients alternately into the first two rows of the Routh array. Each entry of a new row comes from the two rows above it; for a cubic a₃s³ + a₂s² + a₁s + a₀ the s¹ entry is b₁ = (a₂·a₁ − a₃·a₀)/a₂. The number of sign changes in the first column equals the number of roots in the right half-plane. With a gain K in the coefficients, every first-column entry must stay positive: the gain that makes the s¹ entry zero is the stability limit, and the s² row then gives the frequency of the sustained oscillation.
With the zero to the right of s = −3 the loop would stay stable for every K > 0.
8.Stability: Routh–Hurwitz & root locus
Answer: sb = −4.367
Root locus: as the gain K goes from 0 to ∞, the closed-loop poles, the roots of 1 + K·G(s) = 0, move from the open-loop poles to the open-loop zeros or to infinity. A point on the real axis belongs to the locus when the number of real poles and zeros to its right is odd. The n − m branches that go to infinity follow asymptotes at the angles (2q + 1)·180°/(n − m), which start from the centroid σₐ = (Σ poles − Σ zeros)/(n − m). Branches leave or join the real axis where dK/ds = 0. The angle condition ∠G(s) = 180° fixes the shape, and the magnitude condition K = 1/|G(s)| gives the gain at any point of the locus.
Gain along the real axis
K(s) = −(s² + 7s)/(s + 11)
Stationary points
Differentiate with the quotient rule and set the numerator to zero.
(2s + 7)(s + 11) − (s² + 7s) = s² + 22s + 77 = 0
s = −11 ± √44 = −4.367, −17.63
Break-away point
sb = −4.367
Answer
sb = −4.367
Between the two break points the locus is a circle centred on the zero, with radius √44 = 6.633.
9.Steady-state error & PID control
Answer: ess = 0.08
Steady-state error: in a unity-feedback loop with open-loop transfer function G(s) the error is E(s) = R(s)/(1 + G(s)), and by the final value theorem ess = lims→0 s·E(s). The system type is the number of poles of G(s) at s = 0. The error constants are Kp = lim G(s), Kv = lim s·G(s) and Ka = lim s²·G(s), all for s → 0. A step of size A gives ess = A/(1 + Kp), a ramp A·t gives A/Kv and a parabola A·t²/2 gives A/Ka. A type-0 loop follows a step with a finite error, a type-1 loop follows it exactly and a ramp with a finite error.
Velocity constant
Kv = lim s·G(s) = 37.5
Step part
Kp = ∞ → estep = 0
Ramp error
ess = 3/37.5 = 0.08
Answer
ess = 0.08
10.Steady-state error & PID control
Answer: %OS = 20.79 %
P, PI and PID control: the controller C(s) = Kp + Ki/s + Kd·s acts on the error. A proportional gain makes the loop faster and reduces the error of a type-0 plant, but never removes it. The integral term adds a pole at s = 0: the system type rises by one, and a step is followed without error. The derivative term adds damping. To choose gains, write the closed-loop characteristic polynomial and compare it with s² + 2ζωns + ωn². Then %OS = 100·e−ζπ/√(1−ζ²), tp = π/ωd with ωd = ωn√(1 − ζ²), and ts ≈ 4/(ζωn).
Characteristic polynomial
s(s + 4) + 4·5 = s² + 4s + 20
ωₙ and ζ
ωₙ = √20 = 4.472 rad/s
ζ = 4/(2·4.472) = 0.4472
Overshoot
%OS = 100·e−0.4472π/√(1 − 0.4472²) = 20.79 %
Answer
%OS = 20.79 %
11.Bode plots & margins
Answer: Q = 22.36
Frequency response: substitute s = jω in the transfer function. The magnitude in decibels is 20·log₁₀|H(jω)| and the phase is the sum of the angles of the numerator factors minus those of the denominator factors. A first-order RC or RL filter has its corner (−3 dB) frequency at ωc = 1/(RC) or R/L, and fc = ωc/(2π); a low-pass filter gives |H| = 1/√(1 + (ω/ωc)²) and φ = −atan(ω/ωc). In the asymptotic (straight-line) Bode plot each pole bends the magnitude down by 20 dB/decade at its corner frequency, each zero bends it up by 20 dB/decade, and an integrator 1/s gives −20 dB/decade at all frequencies. Gain crossover ωc: |L(jω)| = 1 (0 dB); phase margin PM = 180° + ∠L(jωc). Phase crossover ω180: ∠L(jω) = −180°; gain margin GM = −20·log₁₀|L(jω180)| dB. The closed loop is stable when both margins are positive.
Resonant frequency
ω₀ = 1/√(LC) = 1/√(0.005·1 × 10⁻⁷) = 44721 rad/s
f₀ = ω₀/(2π) = 7118 Hz
Quality factor
BW = R/L = 10/0.005 = 2000 rad/s = 318.3 Hz
Q = ω₀/BW = 44721/2000 = 22.36
Answer
Q = 22.36
12.Bode plots & margins
Answer: PM = 47.39 °
Frequency response: substitute s = jω in the transfer function. The magnitude in decibels is 20·log₁₀|H(jω)| and the phase is the sum of the angles of the numerator factors minus those of the denominator factors. A first-order RC or RL filter has its corner (−3 dB) frequency at ωc = 1/(RC) or R/L, and fc = ωc/(2π); a low-pass filter gives |H| = 1/√(1 + (ω/ωc)²) and φ = −atan(ω/ωc). In the asymptotic (straight-line) Bode plot each pole bends the magnitude down by 20 dB/decade at its corner frequency, each zero bends it up by 20 dB/decade, and an integrator 1/s gives −20 dB/decade at all frequencies. Gain crossover ωc: |L(jω)| = 1 (0 dB); phase margin PM = 180° + ∠L(jωc). Phase crossover ω180: ∠L(jω) = −180°; gain margin GM = −20·log₁₀|L(jω180)| dB. The closed loop is stable when both margins are positive.