1Formulas and methods

Stability: Routh–Hurwitz & root locus

Stability
all roots of the characteristic polynomial in the left half-plane
Routh array, s¹ entry of a cubic
b1 = (a2a1 − a3a0)/a2
Right half-plane roots
number of sign changes in the first column
Cubic s³ + a₂s² + a₁s + a₀
stable when all a > 0 and a₂·a₁ > a₀
K/(s(s + a)(s + b))
Kmax = ab(a + b), ω = √(ab)
Characteristic equation
1 + K·G(s) = 0
Asymptotes
σa = (Σp − Σz)/(n − m), θ = (2q + 1)·180°/(n − m)
Break-away and break-in points
dK/ds = 0
Magnitude condition
K = 1/|G(s)|
Angle of departure
θd = 180° − Σ∠(from other poles) + Σ∠(from zeros)

Method

  1. Write the closed-loop characteristic polynomial: the denominator of 1 + K·G(s) = 0, multiplied out.
  2. Put the coefficients alternately into the first two rows of the Routh array and build the remaining rows.
  3. Count the sign changes in the first column: each one is a pole in the right half-plane. With K in the array, demand that every first-column entry stays positive.
  4. For a root locus, mark the poles and zeros, the real-axis segments, the asymptotes from the centroid and the break points where dK/ds = 0. Use K = 1/|G(s)| for the gain at a point.

Steady-state error & PID control

System type
number of poles of G(s) at s = 0
Error constants
Kp = lim G(s), Kv = lim s·G(s), Ka = lim s²·G(s) (s → 0)
Step A
ess = A/(1 + Kp)
Ramp A·t
ess = A/Kv
Parabola A·t²/2
ess = A/Ka
PID controller
C(s) = Kp + Ki/s + Kd·s
Second-order target
s² + 2ζωns + ωn²
Overshoot and timing
%OS = 100·e−ζπ/√(1−ζ²), tp = π/ωd, ts ≈ 4/(ζωn)

Method

  1. Count the poles of the open loop C(s)·G(s) at s = 0: that is the system type.
  2. Work out the error constant that matches the input: Kp for a step, Kv for a ramp, Ka for a parabola.
  3. Apply ess = A/(1 + Kp), A/Kv or A/Ka, or solve it for the gain you need.
  4. For a damping or speed specification, write the closed-loop characteristic polynomial and match it with s² + 2ζω_n·s + ω_n².

2Practice problems

1.Step responseMedium
t (s)y(t)3

A system has the transfer function G(s) = 123/(s² + 4s + 41) and receives a unit step input. Find the damping ratio ζ.

G(s) = 123/(s² + 4s + 41)
ζ =
2.Step responseHard
k = 2000 N/mc = 170 N·s/mm = 10 kgF = 100 Nx(t)

A mass m = 10 kg hangs on a spring k = 2000 N/m with a viscous damper c = 170 N·s/m (m·x″ + c·x′ + k·x = F). At rest in equilibrium, a constant force F = 100 N is suddenly applied. Find the largest displacement xmax in mm.

m = 10 kgk = 2000 N/mc = 170 N·s/mF = 100 N
xmax = mm
3.Bode plots & marginsMedium
|H| (dB)0.11101001000−60−40−2002040ω (rad/s)ω = 1

Find the exact magnitude |G(jω)| of G(s) = 1950/((s + 10)(s + 13)) at ω = 1 rad/s, in dB.

G(s) = 1950/((s + 10)(s + 13))ω = 1 rad/s
|G(jω)| = dB
4.Bode plots & marginsHard
|H| (dB)0.10.1111010100100−80−60−40−2002040ω (rad/s)φ (°)ω (rad/s)−270−180−900ω180​ = ?

A unity-feedback loop has the open-loop transfer function L(s) = 34/(s(s + 3)(s + 4)). Find the phase crossover frequency ω180, where ∠L(jω) = −180°.

L(s) = 34/(s(s + 3)(s + 4))
ω180 = rad/s
5.Stability: Routh–Hurwitz & root locusMedium
R(s)+K1(s + 2)(s + 4)(s + 6)C(s)−

A unity-feedback loop has L(s) = K/((s + 2)(s + 4)(s + 6)), with K > 0. Find the largest gain Kmax for which the closed loop is stable.

L(s) = K/((s + 2)(s + 4)(s + 6))
Kmax =
6.Stability: Routh–Hurwitz & root locusHard
ReIm−2−4−6j2j4

The root locus of L(s) = K/((s + 1)(s + 3)(s + 6)) is sketched. Find the frequency ω at which the locus crosses the imaginary axis.

L(s) = K/((s + 1)(s + 3)(s + 6))
ω = rad/s
7.Steady-state error & PID controlMedium
r(t) = 0.5·t²/2+2(s + 1)s²(s + 2)C(s)−

The parabolic input r(t) = 0.5·t²/2 is applied to a unity-feedback loop with G(s) = 2(s + 1)/(s²(s + 2)). Find the steady-state error ess.

G(s) = 2(s + 1)/(s²(s + 2))r(t) = 0.5·t²/2
ess =
8.Steady-state error & PID controlHard
R(s)+2 + Kd​s5s(s + 2)C(s)−

A PD controller C(s) = 2 + Kd·s drives the plant G(s) = 5/(s(s + 2)) in a unity-feedback loop. Find the derivative gain Kd that gives the closed loop a damping ratio ζ = 0.8.

G(s) = 5/(s(s + 2))Kp = 2ζ = 0.8
Kd = s
9.Block diagramsMedium
R(s)+27s + 8G(s)C(s)0.5H−

A plant G(s) = 27/(s + 8) is controlled in a negative feedback loop whose sensor has the gain H = 0.5. A step of size 1 is applied at R. Find the steady-state output css.

G(s) = 27/(s + 8)H = 0.5R = 1
css =
10.Block diagramsHard
R(s)+Kcontroller+D(s)+10s + 4plantC(s)−

A proportional controller K drives the plant G(s) = 10/(s + 4) in a unity negative feedback loop. A disturbance step of size 2 enters at the plant input while R = 0. Find the smallest gain K that keeps the steady-state output at or below 0.25.

G(s) = 10/(s + 4)D = 2css ≤ 0.25
K =

3Solutions

1.Step response

Answer: ζ = 0.3123

Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).

Compare with the standard form

The denominator must match s² + 2ζωₙs + ωₙ².

ωₙ² = 41 → ωₙ = 6.403 rad/s
2ζωₙ = 4 → ζ = 4/(2·6.403) = 0.3123

Result

ζ = 0.3123

Answer

ζ = 0.3123
2.Step response

Answer: xmax = 54.71 mm

Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).

Natural frequency and damping ratio

ωₙ = √(k/m) = √(2000/10) = 14.14 rad/s
ζ = c/(2√(km)) = 170/(2·√(2000·10)) = 0.601

Result

xst = F/k = 100/2000 m = 50 mm
%OS = 9.418 %
xmax = 50·(1 + 0.09418) = 54.71 mm

Answer

xmax = 54.71 mm
3.Bode plots & margins

Answer: |G(jω)| = 23.45 dB

Frequency response: substitute s = jω in the transfer function. The magnitude in decibels is 20·log₁₀|H(jω)| and the phase is the sum of the angles of the numerator factors minus those of the denominator factors. A first-order RC or RL filter has its corner (−3 dB) frequency at ωc = 1/(RC) or R/L, and fc = ωc/(2π); a low-pass filter gives |H| = 1/√(1 + (ω/ωc)²) and φ = −atan(ω/ωc). In the asymptotic (straight-line) Bode plot each pole bends the magnitude down by 20 dB/decade at its corner frequency, each zero bends it up by 20 dB/decade, and an integrator 1/s gives −20 dB/decade at all frequencies. Gain crossover ωc: |L(jω)| = 1 (0 dB); phase margin PM = 180° + ∠L(jωc). Phase crossover ω180: ∠L(jω) = −180°; gain margin GM = −20·log₁₀|L(jω180)| dB. The closed loop is stable when both margins are positive.

Multiply the magnitudes

|G(j1)| = 1950/(√(1² + 10²)·√(1² + 13²)) = 1950/(10.05·13.04) = 14.88

Result

20·log₁₀(14.88) = 23.45 dB

Answer

|G(jω)| = 23.45 dB
4.Bode plots & margins

Answer: ω180 = 3.464 rad/s

Frequency response: substitute s = jω in the transfer function. The magnitude in decibels is 20·log₁₀|H(jω)| and the phase is the sum of the angles of the numerator factors minus those of the denominator factors. A first-order RC or RL filter has its corner (−3 dB) frequency at ωc = 1/(RC) or R/L, and fc = ωc/(2π); a low-pass filter gives |H| = 1/√(1 + (ω/ωc)²) and φ = −atan(ω/ωc). In the asymptotic (straight-line) Bode plot each pole bends the magnitude down by 20 dB/decade at its corner frequency, each zero bends it up by 20 dB/decade, and an integrator 1/s gives −20 dB/decade at all frequencies. Gain crossover ωc: |L(jω)| = 1 (0 dB); phase margin PM = 180° + ∠L(jωc). Phase crossover ω180: ∠L(jω) = −180°; gain margin GM = −20·log₁₀|L(jω180)| dB. The closed loop is stable when both margins are positive.

Phase crossover

(ω/3)·(ω/4) = 1 → ω180 = √(3·4) = 3.464 rad/s

Answer

ω180 = 3.464 rad/s
5.Stability: Routh–Hurwitz & root locus

Answer: Kmax = 480

Routh–Hurwitz criterion: a linear system is stable when every root of its characteristic polynomial lies in the left half of the s-plane. Write the coefficients alternately into the first two rows of the Routh array. Each entry of a new row comes from the two rows above it; for a cubic a₃s³ + a₂s² + a₁s + a₀ the s¹ entry is b₁ = (a₂·a₁ − a₃·a₀)/a₂. The number of sign changes in the first column equals the number of roots in the right half-plane. With a gain K in the coefficients, every first-column entry must stay positive: the gain that makes the s¹ entry zero is the stability limit, and the s² row then gives the frequency of the sustained oscillation.

Characteristic polynomial

s³ + 12s² + 44s + 48 + K = 0

Routh array

s³: 1, 44
s²: 12, 48 + K
s¹: (12·44 − 48 − K)/12
s⁰: 48 + K

Condition

The s¹ entry must stay positive.

K < 12·44 − 48 = 480

Answer

Kmax = 480

At the limit the loop oscillates at ω = √44 = 6.633 rad/s.

6.Stability: Routh–Hurwitz & root locus

Answer: ω = 5.196 rad/s

Root locus: as the gain K goes from 0 to ∞, the closed-loop poles, the roots of 1 + K·G(s) = 0, move from the open-loop poles to the open-loop zeros or to infinity. A point on the real axis belongs to the locus when the number of real poles and zeros to its right is odd. The n − m branches that go to infinity follow asymptotes at the angles (2q + 1)·180°/(n − m), which start from the centroid σₐ = (Σ poles − Σ zeros)/(n − m). Branches leave or join the real axis where dK/ds = 0. The angle condition ∠G(s) = 180° fixes the shape, and the magnitude condition K = 1/|G(s)| gives the gain at any point of the locus.

Critical gain

s³ + 10s² + 27s + 18 + K = 0
s¹: (10·27 − 18 − K)/10 = 0 → K = 252

Crossing frequency

10s² + 18 + 252 = 10s² + 270 = 0 → s² = −27
ω = √27 = 5.196 rad/s

Answer

ω = 5.196 rad/s
7.Steady-state error & PID control

Answer: ess = 0.5

Steady-state error: in a unity-feedback loop with open-loop transfer function G(s) the error is E(s) = R(s)/(1 + G(s)), and by the final value theorem ess = lims→0 s·E(s). The system type is the number of poles of G(s) at s = 0. The error constants are Kp = lim G(s), Kv = lim s·G(s) and Ka = lim s²·G(s), all for s → 0. A step of size A gives ess = A/(1 + Kp), a ramp A·t gives A/Kv and a parabola A·t²/2 gives A/Ka. A type-0 loop follows a step with a finite error, a type-1 loop follows it exactly and a ramp with a finite error.

Acceleration constant

Ka = 2·1/2 = 1

Parabola error

ess = 0.5/1 = 0.5

Answer

ess = 0.5
8.Steady-state error & PID control

Answer: Kd = 0.6119 s

P, PI and PID control: the controller C(s) = Kp + Ki/s + Kd·s acts on the error. A proportional gain makes the loop faster and reduces the error of a type-0 plant, but never removes it. The integral term adds a pole at s = 0: the system type rises by one, and a step is followed without error. The derivative term adds damping. To choose gains, write the closed-loop characteristic polynomial and compare it with s² + 2ζωns + ωn². Then %OS = 100·e−ζπ/√(1−ζ²), tp = π/ωd with ωd = ωn√(1 − ζ²), and ts ≈ 4/(ζωn).

Characteristic polynomial

s(s + 2) + 5(2 + Kds) = s² + (2 + 5Kd)s + 10

Natural frequency

ωₙ = √10 = 3.162 rad/s

Derivative gain

2 + 5Kd = 2·0.8·3.162 = 5.06
Kd = 0.6119 s

Answer

Kd = 0.6119 s

The derivative term adds damping without changing ωₙ.

9.Block diagrams

Answer: css = 1.256

Block-diagram algebra: blocks in series multiply (G₁·G₂), blocks in parallel add (G₁ + G₂), and a loop with forward path G and feedback path H reduces to T = G/(1 + G·H) for negative feedback and G/(1 − G·H) for positive feedback. Reduce inner loops first, then work outwards. The closed-loop poles are the roots of the characteristic equation 1 + G(s)H(s) = 0. For a stable loop, a step input of size A gives the steady-state output A·T(0); with unity feedback the steady-state error to a step is A/(1 + Kp) with Kp = G(0).

Closed-loop transfer function

T(s) = G/(1 + G·H) = 27/(s + 8 + 13.5) = 27/(s + 21.5)

Result

css = R·T(0) = 1·27/21.5 = 1.256

Answer

css = 1.256
10.Block diagrams

Answer: K = 7.6

Block-diagram algebra: blocks in series multiply (G₁·G₂), blocks in parallel add (G₁ + G₂), and a loop with forward path G and feedback path H reduces to T = G/(1 + G·H) for negative feedback and G/(1 − G·H) for positive feedback. Reduce inner loops first, then work outwards. The closed-loop poles are the roots of the characteristic equation 1 + G(s)H(s) = 0. For a stable loop, a step input of size A gives the steady-state output A·T(0); with unity feedback the steady-state error to a step is A/(1 + Kp) with Kp = G(0).

Disturbance response

css = D·G(0)/(1 + K·G(0)) = 2·10/(4 + 10K)

Solve for K

4 + 10K = 2·10/0.25 = 80
K = (80 − 4)/10 = 7.6

Answer

K = 7.6