Control Engineering 2: Feedback Control Design: cram pack

Formula sheets, the key method steps for every topic and 10 practice problems, with full solutions at the back.

New problemsBack to the course

In the print window, choose “Save as PDF” to keep a copy on your device.

1Formulas and methods

Stability: Routh–Hurwitz & root locus

Stability
all roots of the characteristic polynomial in the left half-plane
Routh array, s¹ entry of a cubic
b1 = (a2a1 − a3a0)/a2
Right half-plane roots
number of sign changes in the first column
Cubic s³ + a₂s² + a₁s + a₀
stable when all a > 0 and a₂·a₁ > a₀
K/(s(s + a)(s + b))
Kmax = ab(a + b), ω = √(ab)
Characteristic equation
1 + K·G(s) = 0
Asymptotes
σa = (Σp − Σz)/(n − m), θ = (2q + 1)·180°/(n − m)
Break-away and break-in points
dK/ds = 0
Magnitude condition
K = 1/|G(s)|
Angle of departure
θd = 180° − Σ∠(from other poles) + Σ∠(from zeros)

Method

  1. Write the closed-loop characteristic polynomial: the denominator of 1 + K·G(s) = 0, multiplied out.
  2. Put the coefficients alternately into the first two rows of the Routh array and build the remaining rows.
  3. Count the sign changes in the first column: each one is a pole in the right half-plane. With K in the array, demand that every first-column entry stays positive.
  4. For a root locus, mark the poles and zeros, the real-axis segments, the asymptotes from the centroid and the break points where dK/ds = 0. Use K = 1/|G(s)| for the gain at a point.

Steady-state error & PID control

System type
number of poles of G(s) at s = 0
Error constants
Kp = lim G(s), Kv = lim s·G(s), Ka = lim s²·G(s) (s → 0)
Step A
ess = A/(1 + Kp)
Ramp A·t
ess = A/Kv
Parabola A·t²/2
ess = A/Ka
PID controller
C(s) = Kp + Ki/s + Kd·s
Second-order target
s² + 2ζωns + ωn²
Overshoot and timing
%OS = 100·e−ζπ/√(1−ζ²), tp = π/ωd, ts ≈ 4/(ζωn)

Method

  1. Count the poles of the open loop C(s)·G(s) at s = 0: that is the system type.
  2. Work out the error constant that matches the input: Kp for a step, Kv for a ramp, Ka for a parabola.
  3. Apply ess = A/(1 + Kp), A/Kv or A/Ka, or solve it for the gain you need.
  4. For a damping or speed specification, write the closed-loop characteristic polynomial and match it with s² + 2ζω_n·s + ω_n².

2Practice problems

1.Step responseMedium
t (s)y(t)1tp​ = ?

A system has the transfer function G(s) = 9/(s² + 2s + 9) and receives a unit step input. Find the peak time tp of the step response.

G(s) = 9/(s² + 2s + 9)
tp = s
2.Step responseHard
t (s)y(t)1tp​ = 2 s12 %

The step response of a second-order system without zeros shows 12 % overshoot, and the first peak occurs at t = 2 s. Find the natural frequency ωn.

%OS = 12 %tp = 2 s
ωn = rad/s
3.Bode plots & marginsMedium
|H| (dB)11101010010010001000−40−2002040ω (rad/s)φ (°)ω (rad/s)−135−90−450ω = 15

Find the phase ∠G(jω) of G(s) = 23(s + 17)/(s(s + 10)) at ω = 15 rad/s, in degrees.

G(s) = 23(s + 17)/(s(s + 10))ω = 15 rad/s
∠G(jω) = °
4.Bode plots & marginsHard
|H| (dB)0.10.1111010100100−80−60−40−2002040ω (rad/s)φ (°)ω (rad/s)−270−180−900ω180​

A unity-feedback loop has the open-loop transfer function L(s) = K/(s(s + 1)(s + 7)). Find the gain K that gives a gain margin of 8 dB.

L(s) = K/(s(s + 1)(s + 7))GM = 8 dB
K =
5.Stability: Routh–Hurwitz & root locusMedium
R(s)+K1s(s + 1)(s + 10)C(s)−

The loop in the diagram has the open-loop transfer function L(s) = K/(s(s + 1)(s + 10)). The gain is raised until the closed loop is on the edge of stability. Find the frequency ω of the sustained oscillation.

L(s) = K/(s(s + 1)(s + 10))
ω = rad/s
6.Stability: Routh–Hurwitz & root locusHard
ReIm−1−2−3−4−5−6−7−8−9−101j1j2sb​

The root locus of L(s) = K/((s + 4)(s + 8)) is shown. Find the gain K at the break-away point sb, where the two closed-loop poles meet on the real axis.

L(s) = K/((s + 4)(s + 8))
K =
7.Steady-state error & PID controlMedium
R(s)+K(s + 4)(s + 5)C(s)−

A unity-feedback loop has G(s) = K/((s + 4)(s + 5)). Find the gain K that gives a steady-state error of 5 % for a step input.

G(s) = K/((s + 4)(s + 5))ess = 5 %
K =
8.Steady-state error & PID controlHard
R(s)+K5s(s + 2)C(s)−

A proportional controller K drives the plant G(s) = 5/(s(s + 2)) in a unity-feedback loop. Find the gain K that gives the closed loop a damping ratio ζ = 0.6.

G(s) = 5/(s(s + 2))ζ = 0.6
K =
9.Block diagramsMedium
R(s)+36s + 2G(s)C(s)0.25H−

A plant G(s) = 36/(s + 2) is controlled in a negative feedback loop whose sensor has the gain H = 0.25. A step of size 10 is applied at R. Find the steady-state output css.

G(s) = 36/(s + 2)H = 0.25R = 10
css =
10.Block diagramsHard
R(s)+Kcontroller+D(s)+4s + 6plantC(s)−

A proportional controller K drives the plant G(s) = 4/(s + 6) in a unity negative feedback loop. A disturbance step of size 2 enters at the plant input while R = 0. Find the smallest gain K that keeps the steady-state output at or below 0.06667.

G(s) = 4/(s + 6)D = 2css ≤ 0.06667
K =

3Solutions

1.Step response

Answer: tp = 1.111 s

Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).

Compare with the standard form

The denominator must match s² + 2ζωₙs + ωₙ².

ωₙ² = 9 → ωₙ = 3 rad/s
2ζωₙ = 2 → ζ = 2/(2·3) = 0.3333

Result

ωd = 3·√(1 − 0.3333²) = 2.828 rad/s → tp = π/ωd = 1.111 s

Answer

tp = 1.111 s
2.Step response

Answer: ωn = 1.895 rad/s

Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).

Damping ratio

ζ = −ln(0.12)/√(π² + ln²(0.12)) = 2.12/√(9.87 + 4.496) = 0.5594

Natural frequency

ωd = π/tp = π/2 = 1.571 rad/s
ωₙ = ωd/√(1 − ζ²) = 1.571/0.8289 = 1.895 rad/s

Answer

ωn = 1.895 rad/s
3.Bode plots & margins

Answer: ∠G(jω) = −104.9 °

Frequency response: substitute s = jω in the transfer function. The magnitude in decibels is 20·log₁₀|H(jω)| and the phase is the sum of the angles of the numerator factors minus those of the denominator factors. A first-order RC or RL filter has its corner (−3 dB) frequency at ωc = 1/(RC) or R/L, and fc = ωc/(2π); a low-pass filter gives |H| = 1/√(1 + (ω/ωc)²) and φ = −atan(ω/ωc). In the asymptotic (straight-line) Bode plot each pole bends the magnitude down by 20 dB/decade at its corner frequency, each zero bends it up by 20 dB/decade, and an integrator 1/s gives −20 dB/decade at all frequencies. Gain crossover ωc: |L(jω)| = 1 (0 dB); phase margin PM = 180° + ∠L(jωc). Phase crossover ω180: ∠L(jω) = −180°; gain margin GM = −20·log₁₀|L(jω180)| dB. The closed loop is stable when both margins are positive.

Add the angles

∠G = atan(15/17) − 90° − atan(15/10) = 41.42° − 90° − 56.31°

Result

∠G(j15) = −104.9°

Answer

∠G(jω) = −104.9°
4.Bode plots & margins

Answer: K = 22.29

Frequency response: substitute s = jω in the transfer function. The magnitude in decibels is 20·log₁₀|H(jω)| and the phase is the sum of the angles of the numerator factors minus those of the denominator factors. A first-order RC or RL filter has its corner (−3 dB) frequency at ωc = 1/(RC) or R/L, and fc = ωc/(2π); a low-pass filter gives |H| = 1/√(1 + (ω/ωc)²) and φ = −atan(ω/ωc). In the asymptotic (straight-line) Bode plot each pole bends the magnitude down by 20 dB/decade at its corner frequency, each zero bends it up by 20 dB/decade, and an integrator 1/s gives −20 dB/decade at all frequencies. Gain crossover ωc: |L(jω)| = 1 (0 dB); phase margin PM = 180° + ∠L(jωc). Phase crossover ω180: ∠L(jω) = −180°; gain margin GM = −20·log₁₀|L(jω180)| dB. The closed loop is stable when both margins are positive.

Phase crossover

(ω/1)·(ω/7) = 1 → ω180 = √(1·7) = 2.646 rad/s

Magnitude at phase crossover

|L(jω180)| = K/(ω·√(ω² + 1)·√(ω² + 49)) = K/(1·7·(1 + 7)) = K/56

Required gain

56/K = 108/20 = 2.512
K = 56/2.512 = 22.29

Answer

K = 22.29
5.Stability: Routh–Hurwitz & root locus

Answer: ω = 3.162 rad/s

Routh–Hurwitz criterion: a linear system is stable when every root of its characteristic polynomial lies in the left half of the s-plane. Write the coefficients alternately into the first two rows of the Routh array. Each entry of a new row comes from the two rows above it; for a cubic a₃s³ + a₂s² + a₁s + a₀ the s¹ entry is b₁ = (a₂·a₁ − a₃·a₀)/a₂. The number of sign changes in the first column equals the number of roots in the right half-plane. With a gain K in the coefficients, every first-column entry must stay positive: the gain that makes the s¹ entry zero is the stability limit, and the s² row then gives the frequency of the sustained oscillation.

Routh array

s³ + 11s² + 10s + K = 0
s³: 1, 10
s²: 11, K
s¹: (11·10 − K)/11
s⁰: K

Critical gain

K = 11·10 = 110

Auxiliary equation

At the critical gain the s¹ row is zero; the s² row gives the poles on the imaginary axis.

11s² + 110 = 0 → s = ±j√10
ω = 3.162 rad/s

Answer

ω = 3.162 rad/s
6.Stability: Routh–Hurwitz & root locus

Answer: K = 4

Root locus: as the gain K goes from 0 to ∞, the closed-loop poles, the roots of 1 + K·G(s) = 0, move from the open-loop poles to the open-loop zeros or to infinity. A point on the real axis belongs to the locus when the number of real poles and zeros to its right is odd. The n − m branches that go to infinity follow asymptotes at the angles (2q + 1)·180°/(n − m), which start from the centroid σₐ = (Σ poles − Σ zeros)/(n − m). Branches leave or join the real axis where dK/ds = 0. The angle condition ∠G(s) = 180° fixes the shape, and the magnitude condition K = 1/|G(s)| gives the gain at any point of the locus.

Break-away point

dK/ds = 0 for K = −(s + 4)(s + 8) gives 2s + 12 = 0.

sb = −6

Magnitude condition

K = |−6 + 4|·|−6 + 8| = 2·2 = 4

Answer

K = 4

For this gain the closed loop is critically damped (ζ = 1).

7.Steady-state error & PID control

Answer: K = 380

Steady-state error: in a unity-feedback loop with open-loop transfer function G(s) the error is E(s) = R(s)/(1 + G(s)), and by the final value theorem ess = lims→0 s·E(s). The system type is the number of poles of G(s) at s = 0. The error constants are Kp = lim G(s), Kv = lim s·G(s) and Ka = lim s²·G(s), all for s → 0. A step of size A gives ess = A/(1 + Kp), a ramp A·t gives A/Kv and a parabola A·t²/2 gives A/Ka. A type-0 loop follows a step with a finite error, a type-1 loop follows it exactly and a ramp with a finite error.

Required error constant

1/(1 + Kp) = 0.05 → Kp = 19

Gain

K/20 = 19 → K = 380

Answer

K = 380

Check the closed-loop stability as well: for this second-order loop any K > 0 is stable.

8.Steady-state error & PID control

Answer: K = 0.5556

P, PI and PID control: the controller C(s) = Kp + Ki/s + Kd·s acts on the error. A proportional gain makes the loop faster and reduces the error of a type-0 plant, but never removes it. The integral term adds a pole at s = 0: the system type rises by one, and a step is followed without error. The derivative term adds damping. To choose gains, write the closed-loop characteristic polynomial and compare it with s² + 2ζωns + ωn². Then %OS = 100·e−ζπ/√(1−ζ²), tp = π/ωd with ωd = ωn√(1 − ζ²), and ts ≈ 4/(ζωn).

Characteristic polynomial

s(s + 2) + 5K = s² + 2s + 5K

Natural frequency

2·0.6·ωₙ = 2 → ωₙ = 1.667 rad/s

Gain

5K = ωₙ² = 2.778 → K = 0.5556

Answer

K = 0.5556
9.Block diagrams

Answer: css = 32.73

Block-diagram algebra: blocks in series multiply (G₁·G₂), blocks in parallel add (G₁ + G₂), and a loop with forward path G and feedback path H reduces to T = G/(1 + G·H) for negative feedback and G/(1 − G·H) for positive feedback. Reduce inner loops first, then work outwards. The closed-loop poles are the roots of the characteristic equation 1 + G(s)H(s) = 0. For a stable loop, a step input of size A gives the steady-state output A·T(0); with unity feedback the steady-state error to a step is A/(1 + Kp) with Kp = G(0).

Closed-loop transfer function

T(s) = G/(1 + G·H) = 36/(s + 2 + 9) = 36/(s + 11)

Result

css = R·T(0) = 10·36/11 = 32.73

Answer

css = 32.73
10.Block diagrams

Answer: K = 28.5

Block-diagram algebra: blocks in series multiply (G₁·G₂), blocks in parallel add (G₁ + G₂), and a loop with forward path G and feedback path H reduces to T = G/(1 + G·H) for negative feedback and G/(1 − G·H) for positive feedback. Reduce inner loops first, then work outwards. The closed-loop poles are the roots of the characteristic equation 1 + G(s)H(s) = 0. For a stable loop, a step input of size A gives the steady-state output A·T(0); with unity feedback the steady-state error to a step is A/(1 + Kp) with Kp = G(0).

Disturbance response

css = D·G(0)/(1 + K·G(0)) = 2·4/(6 + 4K)

Solve for K

6 + 4K = 2·4/0.06667 = 120
K = (120 − 6)/4 = 28.5

Answer

K = 28.5

ExamProblems · examproblems.com/courses/control-engineering-2