1Formulas and methods
Stability: Routh–Hurwitz & root locus
Stability
all roots of the characteristic polynomial in the left half-plane
Routh array, s¹ entry of a cubic
b1 = (a2a1 − a3a0)/a2
Right half-plane roots
number of sign changes in the first column
Cubic s³ + a₂s² + a₁s + a₀
stable when all a > 0 and a₂·a₁ > a₀
K/(s(s + a)(s + b))
Kmax = ab(a + b), ω = √(ab)
Characteristic equation
1 + K·G(s) = 0
Asymptotes
σa = (Σp − Σz)/(n − m), θ = (2q + 1)·180°/(n − m)
Break-away and break-in points
dK/ds = 0
Magnitude condition
K = 1/|G(s)|
Angle of departure
θd = 180° − Σ∠(from other poles) + Σ∠(from zeros)
Method
Write the closed-loop characteristic polynomial: the denominator of 1 + K·G(s) = 0, multiplied out.
Put the coefficients alternately into the first two rows of the Routh array and build the remaining rows.
Count the sign changes in the first column: each one is a pole in the right half-plane. With K in the array, demand that every first-column entry stays positive.
For a root locus, mark the poles and zeros, the real-axis segments, the asymptotes from the centroid and the break points where dK/ds = 0. Use K = 1/|G(s)| for the gain at a point.
Steady-state error & PID control
System type
number of poles of G(s) at s = 0
Error constants
Kp = lim G(s), Kv = lim s·G(s), Ka = lim s²·G(s) (s → 0)
Step A
ess = A/(1 + Kp)
Ramp A·t
ess = A/Kv
Parabola A·t²/2
ess = A/Ka
PID controller
C(s) = Kp + Ki/s + Kd·s
Second-order target
s² + 2ζωns + ωn²
Overshoot and timing
%OS = 100·e−ζπ/√(1−ζ²), tp = π/ωd, ts ≈ 4/(ζωn)
Method
Count the poles of the open loop C(s)·G(s) at s = 0: that is the system type.
Work out the error constant that matches the input: Kp for a step, Kv for a ramp, Ka for a parabola.
Apply ess = A/(1 + Kp), A/Kv or A/Ka, or solve it for the gain you need.
For a damping or speed specification, write the closed-loop characteristic polynomial and match it with s² + 2ζω_n·s + ω_n².
2Practice problems
1.Step responseMedium
A system has the transfer function G(s) = 66/(s² + 13s + 66) and receives a unit step input. The poles are s = σ ± jωd. Find the real part σ.
G(s) = 66/(s² + 13s + 66)
σ =
2.Step responseHard
A unity negative feedback loop has G(s) = K/(s(s + 16)). Find the gain K that gives a step response with 2 % overshoot.
G(s) = K/(s(s + 16))%OS = 2 %
K =
3.Bode plots & marginsMedium
In the series RLC band-pass filter shown the output is taken across R = 5 Ω, with L = 1 mH and C = 0.1 µF. Find the quality factor Q.
R = 5 ΩL = 1 mHC = 0.1 µF
Q =
4.Bode plots & marginsHard
A unity-feedback loop has the open-loop transfer function L(s) = 720/(s(s + 20)). Find the phase margin PM in degrees.
L(s) = 720/(s(s + 20))
PM = °
5.Stability: Routh–Hurwitz & root locusMedium
The loop in the diagram has the open-loop transfer function L(s) = K/(s(s + 6)(s + 10)). Find the largest gain Kmax for which the closed loop is stable.
L(s) = K/(s(s + 6)(s + 10))
Kmax =
6.Stability: Routh–Hurwitz & root locusHard
For the loop L(s) = K/(s(s + 4)(s + 8)), find the gain K that puts a closed-loop pole at s = −1.5.
L(s) = K/(s(s + 4)(s + 8))s = −1.5
K =
7.Steady-state error & PID controlMedium
A ramp r(t) = 3t is applied to a unity-feedback loop with G(s) = 2(s + 3)/(s(s + 4)(s + 5)). Find the steady-state error ess.
G(s) = 2(s + 3)/(s(s + 4)(s + 5))r(t) = 3t
ess =
8.Steady-state error & PID controlHard
A proportional controller K drives the plant G(s) = 10/(s(s + 8)) in a unity-feedback loop. Find the gain K that gives the closed loop a damping ratio ζ = 0.707.
G(s) = 10/(s(s + 8))ζ = 0.707
K =
9.Block diagramsMedium
The plant G(s) = 1/(s + 3) has an inner (minor) negative feedback loop with gain H₁ = 5. A controller gain K = 15 and an outer unity negative feedback loop close the system. Find the closed-loop DC gain T(0).
G(s) = 1/(s + 3)H₁ = 5K = 15
T(0) =
10.Block diagramsHard
A proportional controller K = 6 drives the plant G(s) = 9/(s + 3) in a unity negative feedback loop. A disturbance D enters at the plant input (it is added to the controller output). A reference step of size 1 and a disturbance step of size 10 are applied together. Find the steady-state output css.
K = 6G(s) = 9/(s + 3)D = 10R = 1
css =
3Solutions
1.Step response
Answer: σ = −6.5
Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).
Compare with the standard form
The denominator must match s² + 2ζωₙs + ωₙ².
ωₙ² = 66 → ωₙ = 8.124 rad/s
2ζωₙ = 13 → ζ = 13/(2·8.124) = 0.8001
Result
σ = −ζωₙ = −13/2 = −6.5
Answer
σ = −6.5
2.Step response
Answer: K = 105.3
Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).
Closed-loop transfer function
T(s) = K/(s² + 16s + K)
Damping ratio from the overshoot
ζ = −ln(0.02)/√(π² + ln²(0.02)) = 0.7797
Gain
ωₙ = 16/(2ζ) = 10.26 rad/s
K = ωₙ² = 105.3
Answer
K = 105.3
3.Bode plots & margins
Answer: Q = 20
Frequency response: substitute s = jω in the transfer function. The magnitude in decibels is 20·log₁₀|H(jω)| and the phase is the sum of the angles of the numerator factors minus those of the denominator factors. A first-order RC or RL filter has its corner (−3 dB) frequency at ωc = 1/(RC) or R/L, and fc = ωc/(2π); a low-pass filter gives |H| = 1/√(1 + (ω/ωc)²) and φ = −atan(ω/ωc). In the asymptotic (straight-line) Bode plot each pole bends the magnitude down by 20 dB/decade at its corner frequency, each zero bends it up by 20 dB/decade, and an integrator 1/s gives −20 dB/decade at all frequencies. Gain crossover ωc: |L(jω)| = 1 (0 dB); phase margin PM = 180° + ∠L(jωc). Phase crossover ω180: ∠L(jω) = −180°; gain margin GM = −20·log₁₀|L(jω180)| dB. The closed loop is stable when both margins are positive.
Resonant frequency
ω₀ = 1/√(LC) = 1/√(0.001·1 × 10⁻⁷) = 100000 rad/s
f₀ = ω₀/(2π) = 15915 Hz
Quality factor
BW = R/L = 5/0.001 = 5000 rad/s = 795.8 Hz
Q = ω₀/BW = 100000/5000 = 20
Answer
Q = 20
4.Bode plots & margins
Answer: PM = 40.53 °
Frequency response: substitute s = jω in the transfer function. The magnitude in decibels is 20·log₁₀|H(jω)| and the phase is the sum of the angles of the numerator factors minus those of the denominator factors. A first-order RC or RL filter has its corner (−3 dB) frequency at ωc = 1/(RC) or R/L, and fc = ωc/(2π); a low-pass filter gives |H| = 1/√(1 + (ω/ωc)²) and φ = −atan(ω/ωc). In the asymptotic (straight-line) Bode plot each pole bends the magnitude down by 20 dB/decade at its corner frequency, each zero bends it up by 20 dB/decade, and an integrator 1/s gives −20 dB/decade at all frequencies. Gain crossover ωc: |L(jω)| = 1 (0 dB); phase margin PM = 180° + ∠L(jωc). Phase crossover ω180: ∠L(jω) = −180°; gain margin GM = −20·log₁₀|L(jω180)| dB. The closed loop is stable when both margins are positive.
Gain crossover
ω⁴ + 400ω² − 518400 = 0
ω² = (−400 + √(160000 + 4·518400))/2 = 547.3
ωc = 23.39 rad/s
Phase margin
∠L(jωc) = −90° − atan(23.39/20) = −139.5°
PM = 180° + ∠L = 40.53°
Answer
PM = 40.53°
5.Stability: Routh–Hurwitz & root locus
Answer: Kmax = 960
Routh–Hurwitz criterion: a linear system is stable when every root of its characteristic polynomial lies in the left half of the s-plane. Write the coefficients alternately into the first two rows of the Routh array. Each entry of a new row comes from the two rows above it; for a cubic a₃s³ + a₂s² + a₁s + a₀ the s¹ entry is b₁ = (a₂·a₁ − a₃·a₀)/a₂. The number of sign changes in the first column equals the number of roots in the right half-plane. With a gain K in the coefficients, every first-column entry must stay positive: the gain that makes the s¹ entry zero is the stability limit, and the s² row then gives the frequency of the sustained oscillation.
Characteristic equation
s³ + 16s² + 60s + K = 0
Routh array
s³: 1, 60
s²: 16, K
s¹: (16·60 − K)/16
s⁰: K
Conditions
Every entry of the first column must be positive.
K > 0
16·60 − K > 0 → K < 960
Answer
Kmax = 960
At K = 960 the closed loop oscillates at ω = √60 = 7.746 rad/s.
6.Stability: Routh–Hurwitz & root locus
Answer: K = 24.38
Root locus: as the gain K goes from 0 to ∞, the closed-loop poles, the roots of 1 + K·G(s) = 0, move from the open-loop poles to the open-loop zeros or to infinity. A point on the real axis belongs to the locus when the number of real poles and zeros to its right is odd. The n − m branches that go to infinity follow asymptotes at the angles (2q + 1)·180°/(n − m), which start from the centroid σₐ = (Σ poles − Σ zeros)/(n − m). Branches leave or join the real axis where dK/ds = 0. The angle condition ∠G(s) = 180° fixes the shape, and the magnitude condition K = 1/|G(s)| gives the gain at any point of the locus.
Magnitude condition
K = |s|·|s + 4|·|s + 8|
Evaluate at the point
K = 1.5·2.5·6.5 = 24.38
Answer
K = 24.38
Check: s(s + 4)(s + 8) + K is zero at s = −1.5.
7.Steady-state error & PID control
Answer: ess = 10
Steady-state error: in a unity-feedback loop with open-loop transfer function G(s) the error is E(s) = R(s)/(1 + G(s)), and by the final value theorem ess = lims→0 s·E(s). The system type is the number of poles of G(s) at s = 0. The error constants are Kp = lim G(s), Kv = lim s·G(s) and Ka = lim s²·G(s), all for s → 0. A step of size A gives ess = A/(1 + Kp), a ramp A·t gives A/Kv and a parabola A·t²/2 gives A/Ka. A type-0 loop follows a step with a finite error, a type-1 loop follows it exactly and a ramp with a finite error.
Velocity constant
Kv = lim s·G(s) = 0.3
Ramp error
ess = 3/0.3 = 10
Answer
ess = 10
8.Steady-state error & PID control
Answer: K = 3.201
P, PI and PID control: the controller C(s) = Kp + Ki/s + Kd·s acts on the error. A proportional gain makes the loop faster and reduces the error of a type-0 plant, but never removes it. The integral term adds a pole at s = 0: the system type rises by one, and a step is followed without error. The derivative term adds damping. To choose gains, write the closed-loop characteristic polynomial and compare it with s² + 2ζωns + ωn². Then %OS = 100·e−ζπ/√(1−ζ²), tp = π/ωd with ωd = ωn√(1 − ζ²), and ts ≈ 4/(ζωn).
Characteristic polynomial
s(s + 8) + 10K = s² + 8s + 10K
Natural frequency
2·0.707·ωₙ = 8 → ωₙ = 5.658 rad/s
Gain
10K = ωₙ² = 32.01 → K = 3.201
Answer
K = 3.201
9.Block diagrams
Answer: T(0) = 0.6522
Block-diagram algebra: blocks in series multiply (G₁·G₂), blocks in parallel add (G₁ + G₂), and a loop with forward path G and feedback path H reduces to T = G/(1 + G·H) for negative feedback and G/(1 − G·H) for positive feedback. Reduce inner loops first, then work outwards. The closed-loop poles are the roots of the characteristic equation 1 + G(s)H(s) = 0. For a stable loop, a step input of size A gives the steady-state output A·T(0); with unity feedback the steady-state error to a step is A/(1 + Kp) with Kp = G(0).
Block-diagram algebra: blocks in series multiply (G₁·G₂), blocks in parallel add (G₁ + G₂), and a loop with forward path G and feedback path H reduces to T = G/(1 + G·H) for negative feedback and G/(1 − G·H) for positive feedback. Reduce inner loops first, then work outwards. The closed-loop poles are the roots of the characteristic equation 1 + G(s)H(s) = 0. For a stable loop, a step input of size A gives the steady-state output A·T(0); with unity feedback the steady-state error to a step is A/(1 + Kp) with Kp = G(0).
Transfer functions
C/D = G/(1 + K·G) = 9/(s + 3 + 54)
C/R = K·G/(1 + K·G) = 54/(s + 3 + 54)
Steady state
css = 1·54/57 + 10·9/57 = 2.526
Answer
css = 2.526
A larger K reduces the effect of the disturbance, but never to zero with a proportional controller.