In the print window, choose “Save as PDF” to keep a copy on your device.
1Formulas and methods
Stability: Routh–Hurwitz & root locus
Stability
all roots of the characteristic polynomial in the left half-plane
Routh array, s¹ entry of a cubic
b1 = (a2a1 − a3a0)/a2
Right half-plane roots
number of sign changes in the first column
Cubic s³ + a₂s² + a₁s + a₀
stable when all a > 0 and a₂·a₁ > a₀
K/(s(s + a)(s + b))
Kmax = ab(a + b), ω = √(ab)
Characteristic equation
1 + K·G(s) = 0
Asymptotes
σa = (Σp − Σz)/(n − m), θ = (2q + 1)·180°/(n − m)
Break-away and break-in points
dK/ds = 0
Magnitude condition
K = 1/|G(s)|
Angle of departure
θd = 180° − Σ∠(from other poles) + Σ∠(from zeros)
Method
Write the closed-loop characteristic polynomial: the denominator of 1 + K·G(s) = 0, multiplied out.
Put the coefficients alternately into the first two rows of the Routh array and build the remaining rows.
Count the sign changes in the first column: each one is a pole in the right half-plane. With K in the array, demand that every first-column entry stays positive.
For a root locus, mark the poles and zeros, the real-axis segments, the asymptotes from the centroid and the break points where dK/ds = 0. Use K = 1/|G(s)| for the gain at a point.
Steady-state error & PID control
System type
number of poles of G(s) at s = 0
Error constants
Kp = lim G(s), Kv = lim s·G(s), Ka = lim s²·G(s) (s → 0)
Step A
ess = A/(1 + Kp)
Ramp A·t
ess = A/Kv
Parabola A·t²/2
ess = A/Ka
PID controller
C(s) = Kp + Ki/s + Kd·s
Second-order target
s² + 2ζωns + ωn²
Overshoot and timing
%OS = 100·e−ζπ/√(1−ζ²), tp = π/ωd, ts ≈ 4/(ζωn)
Method
Count the poles of the open loop C(s)·G(s) at s = 0: that is the system type.
Work out the error constant that matches the input: Kp for a step, Kv for a ramp, Ka for a parabola.
Apply ess = A/(1 + Kp), A/Kv or A/Ka, or solve it for the gain you need.
For a damping or speed specification, write the closed-loop characteristic polynomial and match it with s² + 2ζω_n·s + ω_n².
2Practice problems
1.Step responseMedium
A system has the transfer function G(s) = 80/(s² + 5s + 40) and receives a unit step input. Find the percent overshoot %OS of the step response.
G(s) = 80/(s² + 5s + 40)
%OS = %
2.Step responseHard
A mass m = 1 kg hangs on a spring k = 400 N/m with a viscous damper c = 6 N·s/m (m·x″ + c·x′ + k·x = F). At rest in equilibrium, a constant force F = 20 N is suddenly applied. Find the damping ratio ζ.
m = 1 kgk = 400 N/mc = 6 N·s/mF = 20 N
ζ =
3.Bode plots & marginsMedium
Find the phase ∠G(jω) of G(s) = 34(s + 1)/(s(s + 10)) at ω = 0.5 rad/s, in degrees.
G(s) = 34(s + 1)/(s(s + 10))ω = 0.5 rad/s
∠G(jω) = °
4.Bode plots & marginsHard
A unity-feedback loop has the open-loop transfer function L(s) = 262/(s(s + 5)(s + 6)). Find the gain margin GM in dB.
L(s) = 262/(s(s + 5)(s + 6))
GM = dB
5.Stability: Routh–Hurwitz & root locusMedium
The plant G(s) = (s + 5)/((s − 3)(s + 1)) has an unstable pole at s = 3. A proportional gain K closes a unity-feedback loop around it. Find the smallest gain Kmin that makes the closed loop stable.
G(s) = (s + 5)/((s − 3)(s + 1))
Kmin =
6.Stability: Routh–Hurwitz & root locusHard
For L(s) = K/((s + 3)(s² + 8s + 32)), find the angle of departure θd of the root locus from the complex pole in the upper half-plane, measured from the positive real axis.
L(s) = K/((s + 3)(s² + 8s + 32))
θd = °
7.Steady-state error & PID controlMedium
The input r(t) = 10 + 3t (a step plus a ramp) is applied to a unity-feedback loop with G(s) = 2(s + 1)/(s(s + 4)). Find the steady-state error ess.
G(s) = 2(s + 1)/(s(s + 4))r(t) = 10 + 3t
ess =
8.Steady-state error & PID controlHard
A PI controller C(s) = 1 + 4/s drives the plant G(s) = 10/((s + 2)(s + 10)) in a unity-feedback loop. Find the steady-state error ess for the ramp input r(t) = 2t.
A unity negative feedback loop has G(s) = 11(s + 7)/((s + 6)(s + 9)). A step of size 2 is applied at the reference. Find the steady-state error ess.
G(s) = 11(s + 7)/((s + 6)(s + 9))R = 2
ess =
10.Block diagramsHard
The plant G(s) = K/(s(s + 8)(s + 10)) is in a unity negative feedback loop. At the largest stable gain the loop oscillates. Find the frequency of oscillation ω in rad/s.
Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).
Compare with the standard form
The denominator must match s² + 2ζωₙs + ωₙ².
ωₙ² = 40 → ωₙ = 6.325 rad/s
2ζωₙ = 5 → ζ = 5/(2·6.325) = 0.3953
Result
%OS = 100·e−ζπ/√(1−ζ²) = 100·e−1.352 = 25.87 %
Answer
%OS = 25.87 %
2.Step response
Answer: ζ = 0.15
Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).
Natural frequency and damping ratio
ωₙ = √(k/m) = √(400/1) = 20 rad/s
ζ = c/(2√(km)) = 6/(2·√(400·1)) = 0.15
Result
ζ = 0.15
Answer
ζ = 0.15
3.Bode plots & margins
Answer: ∠G(jω) = −66.3 °
Frequency response: substitute s = jω in the transfer function. The magnitude in decibels is 20·log₁₀|H(jω)| and the phase is the sum of the angles of the numerator factors minus those of the denominator factors. A first-order RC or RL filter has its corner (−3 dB) frequency at ωc = 1/(RC) or R/L, and fc = ωc/(2π); a low-pass filter gives |H| = 1/√(1 + (ω/ωc)²) and φ = −atan(ω/ωc). In the asymptotic (straight-line) Bode plot each pole bends the magnitude down by 20 dB/decade at its corner frequency, each zero bends it up by 20 dB/decade, and an integrator 1/s gives −20 dB/decade at all frequencies. Gain crossover ωc: |L(jω)| = 1 (0 dB); phase margin PM = 180° + ∠L(jωc). Phase crossover ω180: ∠L(jω) = −180°; gain margin GM = −20·log₁₀|L(jω180)| dB. The closed loop is stable when both margins are positive.
Frequency response: substitute s = jω in the transfer function. The magnitude in decibels is 20·log₁₀|H(jω)| and the phase is the sum of the angles of the numerator factors minus those of the denominator factors. A first-order RC or RL filter has its corner (−3 dB) frequency at ωc = 1/(RC) or R/L, and fc = ωc/(2π); a low-pass filter gives |H| = 1/√(1 + (ω/ωc)²) and φ = −atan(ω/ωc). In the asymptotic (straight-line) Bode plot each pole bends the magnitude down by 20 dB/decade at its corner frequency, each zero bends it up by 20 dB/decade, and an integrator 1/s gives −20 dB/decade at all frequencies. Gain crossover ωc: |L(jω)| = 1 (0 dB); phase margin PM = 180° + ∠L(jωc). Phase crossover ω180: ∠L(jω) = −180°; gain margin GM = −20·log₁₀|L(jω180)| dB. The closed loop is stable when both margins are positive.
Routh–Hurwitz criterion: a linear system is stable when every root of its characteristic polynomial lies in the left half of the s-plane. Write the coefficients alternately into the first two rows of the Routh array. Each entry of a new row comes from the two rows above it; for a cubic a₃s³ + a₂s² + a₁s + a₀ the s¹ entry is b₁ = (a₂·a₁ − a₃·a₀)/a₂. The number of sign changes in the first column equals the number of roots in the right half-plane. With a gain K in the coefficients, every first-column entry must stay positive: the gain that makes the s¹ entry zero is the stability limit, and the s² row then gives the frequency of the sustained oscillation.
For s² + c₁s + c₀ all roots lie in the left half-plane exactly when c₁ > 0 and c₀ > 0.
-2 + K > 0 → K > 2
5K − 3 > 0 → K > 0.6
Kmin = 2
Answer
Kmin = 2
6.Stability: Routh–Hurwitz & root locus
Answer: θd = −14.04 °
Root locus: as the gain K goes from 0 to ∞, the closed-loop poles, the roots of 1 + K·G(s) = 0, move from the open-loop poles to the open-loop zeros or to infinity. A point on the real axis belongs to the locus when the number of real poles and zeros to its right is odd. The n − m branches that go to infinity follow asymptotes at the angles (2q + 1)·180°/(n − m), which start from the centroid σₐ = (Σ poles − Σ zeros)/(n − m). Branches leave or join the real axis where dK/ds = 0. The angle condition ∠G(s) = 180° fixes the shape, and the magnitude condition K = 1/|G(s)| gives the gain at any point of the locus.
Pole locations
s² + 8s + 32 = 0 → s = −4 ± j4
s = −3
Angles from the other poles
∠(−4 + j4 + 3) = atan2(4, -1) = 104°
∠(−4 + j4 − (−4 − j4)) = ∠(j8) = 90°
Angle of departure
θd = 180° − 104° − 90° = −14.04°
Answer
θd = −14.04°
7.Steady-state error & PID control
Answer: ess = 6
Steady-state error: in a unity-feedback loop with open-loop transfer function G(s) the error is E(s) = R(s)/(1 + G(s)), and by the final value theorem ess = lims→0 s·E(s). The system type is the number of poles of G(s) at s = 0. The error constants are Kp = lim G(s), Kv = lim s·G(s) and Ka = lim s²·G(s), all for s → 0. A step of size A gives ess = A/(1 + Kp), a ramp A·t gives A/Kv and a parabola A·t²/2 gives A/Ka. A type-0 loop follows a step with a finite error, a type-1 loop follows it exactly and a ramp with a finite error.
Velocity constant
Kv = lim s·G(s) = 0.5
Step part
Kp = ∞ → estep = 0
Ramp error
ess = 3/0.5 = 6
Answer
ess = 6
8.Steady-state error & PID control
Answer: ess = 1
P, PI and PID control: the controller C(s) = Kp + Ki/s + Kd·s acts on the error. A proportional gain makes the loop faster and reduces the error of a type-0 plant, but never removes it. The integral term adds a pole at s = 0: the system type rises by one, and a step is followed without error. The derivative term adds damping. To choose gains, write the closed-loop characteristic polynomial and compare it with s² + 2ζωns + ωn². Then %OS = 100·e−ζπ/√(1−ζ²), tp = π/ωd with ωd = ωn√(1 − ζ²), and ts ≈ 4/(ζωn).
Velocity constant
s·C(s) = 1s + 4 → 4 as s → 0.
Kv = 4·10/20 = 2
Ramp error
ess = 2/2 = 1
Answer
ess = 1
The PI controller removes the step error completely; a ramp is followed with a constant lag.
9.Block diagrams
Answer: ess = 0.8244
Block-diagram algebra: blocks in series multiply (G₁·G₂), blocks in parallel add (G₁ + G₂), and a loop with forward path G and feedback path H reduces to T = G/(1 + G·H) for negative feedback and G/(1 − G·H) for positive feedback. Reduce inner loops first, then work outwards. The closed-loop poles are the roots of the characteristic equation 1 + G(s)H(s) = 0. For a stable loop, a step input of size A gives the steady-state output A·T(0); with unity feedback the steady-state error to a step is A/(1 + Kp) with Kp = G(0).
Position error constant
Kₚ = G(0) = 11·7/(6·9) = 1.426
Steady-state error
ess = A/(1 + Kₚ) = 2/(1 + 1.426) = 0.8244
Answer
ess = 0.8244
10.Block diagrams
Answer: ω = 8.944 rad/s
Block-diagram algebra: blocks in series multiply (G₁·G₂), blocks in parallel add (G₁ + G₂), and a loop with forward path G and feedback path H reduces to T = G/(1 + G·H) for negative feedback and G/(1 − G·H) for positive feedback. Reduce inner loops first, then work outwards. The closed-loop poles are the roots of the characteristic equation 1 + G(s)H(s) = 0. For a stable loop, a step input of size A gives the steady-state output A·T(0); with unity feedback the steady-state error to a step is A/(1 + Kp) with Kp = G(0).