In the print window, choose “Save as PDF” to keep a copy on your device.
1Formulas and methods
Stability: Routh–Hurwitz & root locus
Stability
all roots of the characteristic polynomial in the left half-plane
Routh array, s¹ entry of a cubic
b1 = (a2a1 − a3a0)/a2
Right half-plane roots
number of sign changes in the first column
Cubic s³ + a₂s² + a₁s + a₀
stable when all a > 0 and a₂·a₁ > a₀
K/(s(s + a)(s + b))
Kmax = ab(a + b), ω = √(ab)
Characteristic equation
1 + K·G(s) = 0
Asymptotes
σa = (Σp − Σz)/(n − m), θ = (2q + 1)·180°/(n − m)
Break-away and break-in points
dK/ds = 0
Magnitude condition
K = 1/|G(s)|
Angle of departure
θd = 180° − Σ∠(from other poles) + Σ∠(from zeros)
Method
Write the closed-loop characteristic polynomial: the denominator of 1 + K·G(s) = 0, multiplied out.
Put the coefficients alternately into the first two rows of the Routh array and build the remaining rows.
Count the sign changes in the first column: each one is a pole in the right half-plane. With K in the array, demand that every first-column entry stays positive.
For a root locus, mark the poles and zeros, the real-axis segments, the asymptotes from the centroid and the break points where dK/ds = 0. Use K = 1/|G(s)| for the gain at a point.
Steady-state error & PID control
System type
number of poles of G(s) at s = 0
Error constants
Kp = lim G(s), Kv = lim s·G(s), Ka = lim s²·G(s) (s → 0)
Step A
ess = A/(1 + Kp)
Ramp A·t
ess = A/Kv
Parabola A·t²/2
ess = A/Ka
PID controller
C(s) = Kp + Ki/s + Kd·s
Second-order target
s² + 2ζωns + ωn²
Overshoot and timing
%OS = 100·e−ζπ/√(1−ζ²), tp = π/ωd, ts ≈ 4/(ζωn)
Method
Count the poles of the open loop C(s)·G(s) at s = 0: that is the system type.
Work out the error constant that matches the input: Kp for a step, Kv for a ramp, Ka for a parabola.
Apply ess = A/(1 + Kp), A/Kv or A/Ka, or solve it for the gain you need.
For a damping or speed specification, write the closed-loop characteristic polynomial and match it with s² + 2ζω_n·s + ω_n².
2Practice problems
1.Step responseMedium
A system has the transfer function G(s) = 28/(s² + 5s + 56) and receives a unit step input. Find the natural frequency ωn in rad/s.
G(s) = 28/(s² + 5s + 56)
ωn = rad/s
2.Step responseHard
A mass m = 10 kg hangs on a spring k = 1000 N/m with a viscous damper c = 30 N·s/m (m·x″ + c·x′ + k·x = F). At rest in equilibrium, a constant force F = 5 N is suddenly applied. Find the time tp at which the displacement is largest.
m = 10 kgk = 1000 N/mc = 30 N·s/mF = 5 N
tp = s
3.Bode plots & marginsMedium
Find the exact magnitude |G(jω)| of G(s) = 3240/((s + 10)(s + 18)) at ω = 5 rad/s, in dB.
G(s) = 3240/((s + 10)(s + 18))ω = 5 rad/s
|G(jω)| = dB
4.Bode plots & marginsHard
A unity-feedback loop has the open-loop transfer function L(s) = 4/(s(s + 1)(s + 2)). Find the phase crossover frequency ω180, where ∠L(jω) = −180°.
L(s) = 4/(s(s + 1)(s + 2))
ω180 = rad/s
5.Stability: Routh–Hurwitz & root locusMedium
The loop in the diagram uses positive feedback, with L(s) = 20/(s(s + 5)(s + 8)). How many closed-loop poles N lie in the right half-plane?
L(s) = 20/(s(s + 5)(s + 8))
N =
6.Stability: Routh–Hurwitz & root locusHard
The root locus of L(s) = K/((s + 1)(s + 3)(s + 5)) is sketched. Find the frequency ω at which the locus crosses the imaginary axis.
L(s) = K/((s + 1)(s + 3)(s + 5))
ω = rad/s
7.Steady-state error & PID controlMedium
A unity-feedback loop with G(s) = K/(s(s + 2)) must follow the ramp r(t) = 1t with a steady-state error of 0.2. Find the gain K.
G(s) = K/(s(s + 2))r(t) = 1tess = 0.2
K =
8.Steady-state error & PID controlHard
A proportional controller K = 2 drives the plant G(s) = 5/(s(s + 5)) in a unity-feedback loop. Find the peak time tp of the step response.
G(s) = 5/(s(s + 5))K = 2
tp = s
9.Block diagramsMedium
A unity negative feedback loop has G(s) = 12(s + 3)/((s + 5)(s + 6)). A step of size 10 is applied at the reference. Find the steady-state error ess.
G(s) = 12(s + 3)/((s + 5)(s + 6))R = 10
ess =
10.Block diagramsHard
A proportional controller K = 9 drives the plant G(s) = 9/(s + 4) in a unity negative feedback loop. A disturbance D enters at the plant input (it is added to the controller output). With R = 0, a disturbance step of size 5 is applied. Find the steady-state output css.
K = 9G(s) = 9/(s + 4)D = 5R = 0
css =
3Solutions
1.Step response
Answer: ωn = 7.483 rad/s
Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).
Compare with the standard form
The denominator must match s² + 2ζωₙs + ωₙ².
ωₙ² = 56 → ωₙ = 7.483 rad/s
2ζωₙ = 5 → ζ = 5/(2·7.483) = 0.3341
Result
ωₙ = 7.483 rad/s
Answer
ωn = 7.483 rad/s
2.Step response
Answer: tp = 0.3178 s
Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).
Natural frequency and damping ratio
ωₙ = √(k/m) = √(1000/10) = 10 rad/s
ζ = c/(2√(km)) = 30/(2·√(1000·10)) = 0.15
Result
ωd = 9.887 rad/s
tp = π/ωd = 0.3178 s
Answer
tp = 0.3178 s
3.Bode plots & margins
Answer: |G(jω)| = 23.81 dB
Frequency response: substitute s = jω in the transfer function. The magnitude in decibels is 20·log₁₀|H(jω)| and the phase is the sum of the angles of the numerator factors minus those of the denominator factors. A first-order RC or RL filter has its corner (−3 dB) frequency at ωc = 1/(RC) or R/L, and fc = ωc/(2π); a low-pass filter gives |H| = 1/√(1 + (ω/ωc)²) and φ = −atan(ω/ωc). In the asymptotic (straight-line) Bode plot each pole bends the magnitude down by 20 dB/decade at its corner frequency, each zero bends it up by 20 dB/decade, and an integrator 1/s gives −20 dB/decade at all frequencies. Gain crossover ωc: |L(jω)| = 1 (0 dB); phase margin PM = 180° + ∠L(jωc). Phase crossover ω180: ∠L(jω) = −180°; gain margin GM = −20·log₁₀|L(jω180)| dB. The closed loop is stable when both margins are positive.
Frequency response: substitute s = jω in the transfer function. The magnitude in decibels is 20·log₁₀|H(jω)| and the phase is the sum of the angles of the numerator factors minus those of the denominator factors. A first-order RC or RL filter has its corner (−3 dB) frequency at ωc = 1/(RC) or R/L, and fc = ωc/(2π); a low-pass filter gives |H| = 1/√(1 + (ω/ωc)²) and φ = −atan(ω/ωc). In the asymptotic (straight-line) Bode plot each pole bends the magnitude down by 20 dB/decade at its corner frequency, each zero bends it up by 20 dB/decade, and an integrator 1/s gives −20 dB/decade at all frequencies. Gain crossover ωc: |L(jω)| = 1 (0 dB); phase margin PM = 180° + ∠L(jωc). Phase crossover ω180: ∠L(jω) = −180°; gain margin GM = −20·log₁₀|L(jω180)| dB. The closed loop is stable when both margins are positive.
Phase crossover
(ω/1)·(ω/2) = 1 → ω180 = √(1·2) = 1.414 rad/s
Answer
ω180 = 1.414 rad/s
5.Stability: Routh–Hurwitz & root locus
Answer: N = 1
Routh–Hurwitz criterion: a linear system is stable when every root of its characteristic polynomial lies in the left half of the s-plane. Write the coefficients alternately into the first two rows of the Routh array. Each entry of a new row comes from the two rows above it; for a cubic a₃s³ + a₂s² + a₁s + a₀ the s¹ entry is b₁ = (a₂·a₁ − a₃·a₀)/a₂. The number of sign changes in the first column equals the number of roots in the right half-plane. With a gain K in the coefficients, every first-column entry must stay positive: the gain that makes the s¹ entry zero is the stability limit, and the s² row then gives the frequency of the sustained oscillation.
Characteristic polynomial
s³ + 13s² + 40s − 20 = 0
Routh array
s³: 1, 40
s²: 13, −20
s¹: 41.54
s⁰: −20
Sign changes in the first column
1 → 13 → 41.54 → −20
N = 1
Answer
N = 1
Positive feedback makes the constant coefficient negative: one real pole always moves into the right half-plane.
6.Stability: Routh–Hurwitz & root locus
Answer: ω = 4.796 rad/s
Root locus: as the gain K goes from 0 to ∞, the closed-loop poles, the roots of 1 + K·G(s) = 0, move from the open-loop poles to the open-loop zeros or to infinity. A point on the real axis belongs to the locus when the number of real poles and zeros to its right is odd. The n − m branches that go to infinity follow asymptotes at the angles (2q + 1)·180°/(n − m), which start from the centroid σₐ = (Σ poles − Σ zeros)/(n − m). Branches leave or join the real axis where dK/ds = 0. The angle condition ∠G(s) = 180° fixes the shape, and the magnitude condition K = 1/|G(s)| gives the gain at any point of the locus.
Critical gain
s³ + 9s² + 23s + 15 + K = 0
s¹: (9·23 − 15 − K)/9 = 0 → K = 192
Crossing frequency
9s² + 15 + 192 = 9s² + 207 = 0 → s² = −23
ω = √23 = 4.796 rad/s
Answer
ω = 4.796 rad/s
7.Steady-state error & PID control
Answer: K = 10
Steady-state error: in a unity-feedback loop with open-loop transfer function G(s) the error is E(s) = R(s)/(1 + G(s)), and by the final value theorem ess = lims→0 s·E(s). The system type is the number of poles of G(s) at s = 0. The error constants are Kp = lim G(s), Kv = lim s·G(s) and Ka = lim s²·G(s), all for s → 0. A step of size A gives ess = A/(1 + Kp), a ramp A·t gives A/Kv and a parabola A·t²/2 gives A/Ka. A type-0 loop follows a step with a finite error, a type-1 loop follows it exactly and a ramp with a finite error.
Required velocity constant
Kv = A/ess = 1/0.2 = 5
Gain
K = 2·Kv = 10
Answer
K = 10
A large gain makes this loop very lightly damped: ζ = 0.3162. That conflict is why compensators are used.
8.Steady-state error & PID control
Answer: tp = 1.622 s
P, PI and PID control: the controller C(s) = Kp + Ki/s + Kd·s acts on the error. A proportional gain makes the loop faster and reduces the error of a type-0 plant, but never removes it. The integral term adds a pole at s = 0: the system type rises by one, and a step is followed without error. The derivative term adds damping. To choose gains, write the closed-loop characteristic polynomial and compare it with s² + 2ζωns + ωn². Then %OS = 100·e−ζπ/√(1−ζ²), tp = π/ωd with ωd = ωn√(1 − ζ²), and ts ≈ 4/(ζωn).
Characteristic polynomial
s(s + 5) + 2·5 = s² + 5s + 10
ωₙ and ζ
ωₙ = √10 = 3.162 rad/s
ζ = 5/(2·3.162) = 0.7906
Peak time
ωd = 3.162·√(1 − 0.7906²) = 1.936 rad/s
tp = π/1.936 = 1.622 s
Answer
tp = 1.622 s
9.Block diagrams
Answer: ess = 4.545
Block-diagram algebra: blocks in series multiply (G₁·G₂), blocks in parallel add (G₁ + G₂), and a loop with forward path G and feedback path H reduces to T = G/(1 + G·H) for negative feedback and G/(1 − G·H) for positive feedback. Reduce inner loops first, then work outwards. The closed-loop poles are the roots of the characteristic equation 1 + G(s)H(s) = 0. For a stable loop, a step input of size A gives the steady-state output A·T(0); with unity feedback the steady-state error to a step is A/(1 + Kp) with Kp = G(0).
Position error constant
Kₚ = G(0) = 12·3/(5·6) = 1.2
Steady-state error
ess = A/(1 + Kₚ) = 10/(1 + 1.2) = 4.545
Answer
ess = 4.545
10.Block diagrams
Answer: css = 0.5294
Block-diagram algebra: blocks in series multiply (G₁·G₂), blocks in parallel add (G₁ + G₂), and a loop with forward path G and feedback path H reduces to T = G/(1 + G·H) for negative feedback and G/(1 − G·H) for positive feedback. Reduce inner loops first, then work outwards. The closed-loop poles are the roots of the characteristic equation 1 + G(s)H(s) = 0. For a stable loop, a step input of size A gives the steady-state output A·T(0); with unity feedback the steady-state error to a step is A/(1 + Kp) with Kp = G(0).
Transfer functions
C/D = G/(1 + K·G) = 9/(s + 4 + 81)
Steady state
css = 5·9/85 = 0.5294
Answer
css = 0.5294
A larger K reduces the effect of the disturbance, but never to zero with a proportional controller.