1Formulas and methods

Series & parallel resistors

Resistors in series
Req = R1 + R2 + …
Resistors in parallel
1/Req = 1/R1 + 1/R2 + …
Two in parallel
Req = R1R2 / (R1 + R2)
Ohm's law
V = I·R
Power
P = V·I = I²R = V²/R

Method

  1. Start at the end of the network furthest from the terminals.
  2. Combine resistors in series by adding them, and resistors in parallel with 1/R = 1/R₁ + 1/R₂ + …
  3. Redraw the circuit after each step.
  4. Repeat until one resistor is left between the terminals.

Nodal analysis

Kirchhoff’s current law
ΣIin = ΣIout
Branch current
I = (Va − Vb)/R
Reference node
Vground = 0

Method

  1. Choose a reference node (ground) and label the other node voltages.
  2. Write Kirchhoff’s current law at every unknown node: currents leaving through each branch equal the currents entering.
  3. Express every branch current as (Va − Vb)/R.
  4. Solve the system of equations, then find any current you need.

Thévenin & Norton

Thévenin voltage
Vth = Vopen circuit
Thévenin resistance
Rth: all sources off, seen from a–b
Norton current
IN = Vth/Rth
Load current
IL = Vth/(Rth + RL)
Maximum power transfer
RL = Rth, Pmax = Vth²/(4Rth)

Method

  1. Remove the load and mark the two terminals a and b.
  2. Find the open-circuit voltage between a and b: this is Vth.
  3. Switch off all independent sources and find the resistance seen from a–b: this is Rth.
  4. Put the load back on the equivalent circuit: Vth in series with Rth.
  5. For the Norton equivalent, convert: IN = Vth/Rth, with RN = Rth in parallel.

RC & RL transients

Time constant
τ = RC | τ = L/R
Response
x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ
Capacitor at DC
open circuit; vC cannot jump
Inductor at DC
short circuit; iL cannot jump
Settled
t ≈ 5τ

Method

  1. Find the initial value just after switching: a capacitor voltage and an inductor current cannot jump.
  2. Find the final value long after switching: a capacitor acts as an open circuit, an inductor as a short circuit.
  3. Find the time constant: τ = RC or τ = L/R, using the resistance seen by the capacitor or inductor.
  4. Use x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ.

AC impedance & phasors

Impedances
ZR = R, ZL = jωL, ZC = 1/(jωC)
Angular frequency
ω = 2πf
Magnitude and angle
|Z| = √(R² + X²), φ = atan(X/R)
Phasor Ohm’s law
V = I·Z

Method

  1. Convert the frequency: ω = 2πf.
  2. Find each reactance: XL = ωL and XC = 1/(ωC).
  3. Add impedances like resistors, with Z = R + jX.
  4. Find the magnitude |Z| = √(R² + X²) and the angle φ = atan(X/R), then use Ohm’s law with phasors.

AC power & power factor

Real power
P = V·I·cos φ
Reactive power
Q = V·I·sin φ
Apparent power
S = V·I = √(P² + Q²)
Power factor
pf = cos φ = P/S
Correction capacitor
QC = P(tan φ1 − tan φ2), C = QC/(ωV²)

Three-phase power

Y connection
VL = √3·Vph, IL = Iph
Δ connection
VL = Vph, IL = √3·Iph
Total real power
P = √3·VL·IL·cos φ = 3·Iph²·R
Apparent and reactive power
S = √3·VL·IL, Q = P·tan φ
Correction capacitors
QC = P(tan φ1 − tan φ2), C = QC/(3ωV²)
Voltage across each capacitor
Δ: VL Y: VL/√3
Motor input
Pin = Pout/η

Transformers

Turns ratio
a = N1/N2 = V1/V2
Current ratio
I1/I2 = N2/N1 = 1/a
Rated current
I = S/V
Referred impedance
Z1′ = a²·ZL
Copper loss at part load
Pcu = x²·Pcu,fl
Efficiency
η = x·S·pf/(x·S·pf + Pcore + x²·Pcu,fl)
Maximum efficiency
x = √(Pcore/Pcu,fl)

2Practice problems

1.Series & parallel resistorsMedium
R1​ = 12 ΩR3​ = 6 Ω+−V1​10 VR2​4 ΩAR4​5 ΩB

Find the equivalent resistance Req seen by the source V1.

V1 = 10 VR1 = 12 ΩR2 = 4 ΩR3 = 6 ΩR4 = 5 Ω
Req = Ω
2.Series & parallel resistorsHard
R1​ = 12 ΩR3​ = 20 ΩR5​ = 20 Ω+−V1​10 VR2​12 ΩAR4​3 ΩBR6​15 Ω

Find the equivalent resistance Req seen by the source V1.

V1 = 10 VR1 = 12 ΩR2 = 12 ΩR3 = 20 ΩR4 = 3 ΩR5 = 20 ΩR6 = 15 Ω
Req = Ω
3.Nodal analysisMedium
R1​ = 4 ΩR3​ = 6 Ω+−V1​30 VR2​2 ΩAR4​10 ΩBIs​4 A

Use nodal analysis to find the power PIs delivered by the current source Is.

V1 = 30 VIs = 4 AR1 = 4 ΩR2 = 2 ΩR3 = 6 ΩR4 = 10 Ω
PIs = W
4.Nodal analysisHard
R1​ = 12 ΩR3​ = 25 Ω+−V1​15 VR2​8 ΩAR4​6 ΩBIs​?

The current source is adjusted until the node voltage at A is VA = 11 V. Use nodal analysis to find the source current Is (direction as shown).

V1 = 15 VR1 = 12 ΩR2 = 8 ΩR3 = 25 ΩR4 = 6 ΩVA = 11 V
Is = A
5.Thévenin & NortonMedium
R1​ = 20 ΩR3​ = 20 Ω+−V1​15 VR2​2 ΩAab

Find the Thévenin voltage Vth seen from terminals a–b.

V1 = 15 VR1 = 20 ΩR2 = 2 ΩR3 = 20 Ω
Vth = V
6.Thévenin & NortonHard
R1​ = 10 ΩR3​ = 25 Ω+−V1​15 VR2​2 ΩAIs​3 ABRL​4 ΩIL​

A load RL = 4 Ω is connected across a–b. Replace the rest of the circuit with its Thévenin equivalent and find the load current IL.

V1 = 15 VIs = 3 AR1 = 10 ΩR2 = 2 ΩR3 = 25 ΩRL = 4 Ω
IL = A
7.RC & RL transientsMedium
R = 20 Ωt = 0L22 mHi(t)

The inductor carries a steady current of 0.5 A. At t = 0 the switch closes the loop through R and the source is removed, so the inductor current decays through R. How long does it take for the current to fall to 0.125 A? Find t.

i(0) = 0.5 AR = 20 ΩL = 22 mH
t = ms
8.RC & RL transientsHard
+−Vs​6 Vt = 0R = 3.3 kΩC33 µF+−vC​vC​(0) = 30 V

Just before the switch closes at t = 0, the capacitor holds 30 V with the polarity shown. Find the capacitor voltage vC at t = 250 ms.

Vs = 6 VR = 3.3 kΩC = 33 µFvC(0) = 30 Vt = 250 ms
vC = V
9.AC impedance & phasorsMedium
230 V200 HzR = 30 ΩL = 200 mHC = 22 µFI

A series RLC circuit is connected to a 230 V (rms), 200 Hz supply. Find the power factor cos φ of the circuit.

V = 230 V (rms)f = 200 HzR = 30 ΩL = 200 mHC = 22 µF
cos φ =
10.AC impedance & phasorsHard
10 V100 HzR = 100 ΩL = 150 mHC = 22 µF+−VC​

A series RLC circuit is connected to a 10 V (rms), 100 Hz supply. Find the rms voltage VC across the capacitor.

V = 10 V (rms)f = 100 HzR = 100 ΩL = 150 mHC = 22 µF
VC = V
11.AC power & power factorMedium
P = 19 kWQ = ?Sφ

A single-phase motor takes 19 kW at a power factor of 0.85 lagging from a 230 V supply. Find the reactive power Q it draws.

P = 19 kWpf = 0.85V = 230 V
Q = kvar
12.AC power & power factorHard
P = 5 kWQ1​S1​φ1​QC​

A single-phase load takes 5 kW at a power factor of 0.65 lagging from a 230 V, 60 Hz supply. A capacitor connected in parallel raises the power factor to 0.92. Find the capacitance C needed.

P = 5 kWpf1 = 0.65pf2 = 0.92V = 230 Vf = 60 Hz
C = µF
13.Three-phase powerMedium
ABCVL​ = 415 VIL​ = ?M18.5 kW, η = 88%cos φ = 0.8

A three-phase induction motor delivers 18.5 kW of mechanical output power at full load. At this load its efficiency is 88% and its power factor is 0.8 lagging. The supply has a line-to-line voltage of 415 V. Find the line current IL.

Pout = 18.5 kWη = 88%cos φ = 0.8VL = 415 V
IL = A
14.Three-phase powerHard
P = 150 kWφ1​S1​Q2​QC​

A balanced three-phase load takes 150 kW at a power factor of 0.65 lagging from a 415 V (line-to-line), 50 Hz supply. A three-phase capacitor bank in parallel with the load must raise the overall power factor to 0.9 lagging. The real power stays the same. The capacitors are connected in Δ. Find the capacitance Cph of each capacitor in µF.

P = 150 kWpf1 = 0.65pf2 = 0.9VL = 415 Vf = 50 Hz
Cph = µF
15.TransformersMedium
4800 V240 VIHV​ = ?ILV​500 kVA

A single-phase 500 kVA, 4800/240 V transformer operates at its rated load. Treat it as ideal. Find the current IHV in the high-voltage winding.

S = 500 kVAV1 = 4800 VV2 = 240 V
IHV = A
16.TransformersHard
pf 0.9550 kVA, 50% load

A single-phase 50 kVA transformer has a core loss of 400 W and a copper loss of 1600 W at rated load. It supplies 50% of its rated kVA at a power factor of 0.95 lagging. Find the total losses Ploss in watts at this load.

S = 50 kVAPcore = 400 WPcu,fl = 1600 Wx = 0.5pf = 0.95
Ploss = W

3Solutions

1.Series & parallel resistors

Answer: Req = 14.93 Ω

Series and parallel resistors: in series the same current flows through each resistor and R = R₁ + R₂ + …. In parallel each resistor has the same voltage and 1/R = 1/R₁ + 1/R₂ + …. A ladder network is reduced one pair at a time until a single equivalent resistance remains.

R1​ = 12 ΩR3​ = 6 Ω+−V1​10 VR2​4 ΩAR4​5 ΩB

Combine resistors from the far end

Start at the end farthest from the source and work back towards it. Resistors carrying the same current are in series; resistors across the same two nodes are in parallel.

R3 + R4 = 6 + 5 = 11 Ω
R2 ∥ 11 = 4·11/(4+11) = 2.933 Ω
Req = R1 + 2.933 = 12 + 2.933 = 14.93 Ω

Answer

Req = 14.93 Ω
2.Series & parallel resistors

Answer: Req = 19.86 Ω

Series and parallel resistors: in series the same current flows through each resistor and R = R₁ + R₂ + …. In parallel each resistor has the same voltage and 1/R = 1/R₁ + 1/R₂ + …. A ladder network is reduced one pair at a time until a single equivalent resistance remains.

R1​ = 12 ΩR3​ = 20 ΩR5​ = 20 Ω+−V1​10 VR2​12 ΩAR4​3 ΩBR6​15 Ω

Combine resistors from the far end

Start at the end farthest from the source and work back towards it. Resistors carrying the same current are in series; resistors across the same two nodes are in parallel.

R5 + R6 = 20 + 15 = 35 Ω
R4 ∥ 35 = 2.763 Ω
R3 + 2.763 = 22.76 Ω
R2 ∥ 22.76 = 7.858 Ω
Req = R1 + 7.858 = 12 + 7.858 = 19.86 Ω

Answer

Req = 19.86 Ω
3.Nodal analysis

Answer: PIs = 90.77 W

Nodal analysis: choose a reference node, label the unknown node voltages, write Kirchhoff’s current law at each unknown node using Ohm’s law (I = ΔV/R), and solve the resulting equations.

KCL at node A

Currents leaving A through the resistors equal the current pushed into A by sources.

VA/R2 + (VA − V1)/R1 + (VA − VB)/R3 = 0
VA/2 + (VA − 30)/4 + (VA − VB)/6 = 0
0.9167·VA − 0.1667·VB = 7.5

KCL at node B

Currents leaving B through the resistors equal the current pushed into B by sources.

VB/R4 + (VB − VA)/R3 = Is
VB/10 + (VB − VA)/6 = 4
−0.1667·VA + 0.2667·VB = 4

Solve

Δ = (0.9167)(0.2667) − (−0.1667)(−0.1667) = 0.2167
VA = Δ1/Δ = 2.667/0.2167 = 12.31 V
VB = Δ2/Δ = 4.917/0.2167 = 22.69 V

Power delivered by the current source

The source pushes Iₛ up into node B, from ground (0 V) to VB. A source whose current leaves its + end delivers P = V·I.

PIs = VB·Is = 22.69·4 = 90.77 W

Answer

PIs = 90.77 W
4.Nodal analysis

Answer: Is = 7.215 A

Nodal analysis: choose a reference node, label the unknown node voltages, write Kirchhoff’s current law at each unknown node using Ohm’s law (I = ΔV/R), and solve the resulting equations.

KCL at node A

VA is known, so this equation gives VB.

(VA − V1)/R1 + VA/R2 + (VA − VB)/R3 = 0
(11 − 15)/12 + 11/8 = (VB − 11)/25
1.042 = (VB − 11)/25 → VB = 37.04 V

KCL at node B

Currents leaving B through the resistors equal the current pushed into B by sources.

Is = (VB − VA)/R3 + VB/R4 = (37.04 − 11)/25 + 37.04/6 = 7.215 A

Answer

Is = 7.215 A
5.Thévenin & Norton

Answer: Vth = 1.364 V

Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.

R1​ = 20 ΩR3​ = 20 ΩSHORTR2​2 ΩAabRth​

Find Rth with every source switched off

Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.

R1 ∥ R2 = 20·2/(20+2) = 1.818 Ω
Rth = (R1 ∥ R2) + R3 = 1.818 + 20 = 21.82 Ω
R1​ = 20 ΩR3​ = 20 Ω+−V1​15 VR2​2 ΩAab+−Vth​

Find Vth, the open-circuit voltage

With a–b open, no current flows through R₃, so there is no drop across it and V_b = V_A. R₁ and R₂ form a voltage divider.

Vth = V1·R2/(R1+R2) = 15·2/(20+2) = 1.364 V
6.Thévenin & Norton

Answer: IL = 2.69 A

Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.

R1​ = 10 ΩR3​ = 25 ΩSHORTR2​2 ΩAOPENBabRth​

Find Rth with every source switched off

Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.

R1 ∥ R2 = 10·2/(10+2) = 1.667 Ω
Rth = (R1 ∥ R2) + R3 = 1.667 + 25 = 26.67 Ω
R1​ = 10 ΩR3​ = 25 Ω+−V1​15 VR2​2 ΩAIs​3 ABab+−Vth​

Find Vth, the open-circuit voltage

With a–b open, the only path for Iₛ is through R₃ into node A. Find V_A by superposition of V₁ and Iₛ, then add the drop across R₃.

VA = V1·R2/(R1+R2) + Is·(R1∥R2) = 2.5 + 3·1.667 = 7.5 V
Vth = VB = VA + Is·R3 = 7.5 + 3·25 = 82.5 V
Rth​ = 26.67 Ω+−Vth​82.5 VRL​4 ΩIL​

Connect the load to the Thévenin equivalent

The Thévenin source and R_th in series behave exactly like the original circuit at a–b, so the load sees a simple series loop.

IL = Vth/(Rth + RL) = 82.5/(26.67 + 4) = 2.69 A
7.RC & RL transients

Answer: t = 1.525 ms

First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.

Time constant

τ = L/R = 22 mH / 20 Ω = 1.1 ms

Solve for the time

0.125 = 0.5·e−t/τ → t = τ·ln(0.5/0.125)
t = 1.1·ln(4) = 1.525 ms

Answer

t = 1.525 ms
8.RC & RL transients

Answer: vC = 8.417 V

First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.

Initial value, final value, time constant

The capacitor voltage cannot jump, so it starts at its stored value and heads for the source voltage.

vC(0) = 30 V, vC(∞) = Vs = 6 V
τ = R·C = 3.3 kΩ · 33 µF = 108.9 ms
vC(t) = 6 + (30 − 6)·e−t/τ

Voltage at the given time

vC(250) = 6 + (24)·e−250/108.9 = 8.417 V

Answer

vC = 8.417 V
9.AC impedance & phasors

Answer: cos φ = 0.1381

AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.

Reactances

XL = 251.3 Ω, XC = 36.17 Ω

Impedance

|Z| = √(30² + (215.2)²) = 217.2 Ω

Power factor

cos φ = R/|Z| = 30/217.2 = 0.1381
The circuit is inductive, so the power factor is lagging.

Answer

cos φ = 0.1381
10.AC impedance & phasors

Answer: VC = 7.067 V

AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.

Reactances

ω = 2πf = 2π·100 = 628.3 rad/s
XL = ωL = 628.3·0.15 = 94.25 Ω
XC = 1/(ωC) = 1/(628.3·22·10⁻⁶) = 72.34 Ω

Impedance

In series the impedances add as complex numbers: Z = R + j(XL − XC).

|Z| = √(R² + (XL − XC)²) = √(100² + (21.9)²) = 102.4 Ω

Current

The same current flows through every element of a series circuit.

I = V/|Z| = 10/102.4 = 0.09768 A

Voltage across the capacitor

VC = I·XC = 0.09768·72.34 = 7.067 V

Answer

VC = 7.067 V
11.AC power & power factor

Answer: Q = 11.78 kvar

AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.

Angle

φ = arccos(0.85) = 31.79°, tan φ = 0.6197

Reactive power

Q = P·tan φ = 19·0.6197 = 11.78 kvar

Answer

Q = 11.78 kvar
12.AC power & power factor

Answer: C = 186.3 µF

AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.

Reactive power before and after

The real power P does not change; only the reactive power drawn from the supply does.

Q1 = P·tan φ1 = 5·tan(49.46°) = 5.846 kvar
Q2 = P·tan φ2 = 5·tan(23.07°) = 2.13 kvar
QC = Q1 − Q2 = 3.716 kvar

Capacitance

A capacitor across the supply delivers Q = V²·ωC.

C = QC/(2πf·V²) = 3716/(2π·60·230²) = 186.3 µF

Answer

C = 186.3 µF
13.Three-phase power

Answer: IL = 36.56 A

Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ.

Electrical input power

Pin = Pout/η = 18.5/0.88 = 21.02 kW

Line current

IL = Pin/(√3·VL·cos φ) = 21023/(√3·415·0.8) = 36.56 A

Answer

IL = 36.56 A
14.Three-phase power

Answer: Cph = 632.8 µF

Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ. Power factor correction: capacitors supply reactive power locally, QC = P·(tan φ1 − tan φ2). Each of the three capacitors supplies QC/3 = V²·ω·C, where V is the voltage across that capacitor: VL in a Δ bank, VL/√3 in a Y bank.

Reactive power before and after

The real power is unchanged, so each power factor fixes the reactive power: Q = P·tan φ.

Q1 = 150·tan(acos 0.65) = 150·1.169 = 175.4 kvar
Q2 = 150·tan(acos 0.9) = 150·0.4843 = 72.65 kvar

Reactive power from the capacitors

QC = Q1 − Q2 = 102.7 kvar

Capacitance per phase

In a Δ bank each capacitor is connected between two lines.

V = 415 V, ω = 2π·50 = 314.2 rad/s
Cph = (QC/3)/(ω·V²) = 34240/(314.2·415²) = 632.8 µF

Answer

Cph = 632.8 µF
15.Transformers

Answer: IHV = 104.2 A

Ideal transformer: the voltages are in the ratio of the turns and the currents in the inverse ratio: V₁/V₂ = N₁/N₂ = a and I₁/I₂ = N₂/N₁ = 1/a, so the power in equals the power out, V₁·I₁ = V₂·I₂. A load impedance Z on the secondary looks like a²·Z from the primary.

Rated current

Both windings carry the same apparent power.

IHV = S/V = 500000/4800 = 104.2 A

Answer

IHV = 104.2 A
16.Transformers

Answer: Ploss = 800 W

Transformer losses: the core loss (hysteresis and eddy currents) depends on the voltage and is the same at any load. The copper loss in the windings goes with the current squared, so at a fraction x of rated load it is x²·Pcu,fl. Efficiency η = Pout/(Pout + Pcore + Pcu), with Pout = x·S·pf. The efficiency is highest at the load where the copper loss equals the core loss.

Copper loss at this load

Pcu = x²·Pcu,fl = 0.25·1600 = 400 W

Total losses

The core loss is the same at any load.

Ploss = 400 + 400 = 800 W

Answer

Ploss = 800 W

The efficiency at this load is η = 96.74%.

ExamProblems · examproblems.com/courses/electrical-engineering-fundamentals