Three branches are connected between node A and ground, as shown. Use nodal analysis to find the current I2 in branch 2, flowing up into node A in the direction of the arrow.
The diamond is a voltage-controlled current source that pushes a current of 0.1·VA (in A, with VA in V) up into node B. Use nodal analysis to find the node voltage VA (measured from ground).
The inductor carries no current before the switch closes at t = 0. Find the voltage vL across the inductor at t = 5 ms.
Vs = 24 VR = 15 ΩL = 68 mHt = 5 ms
vL = V
8.RC & RL transientsHard
Just before the switch closes at t = 0, the capacitor holds 3 V with the polarity shown. How long does it take for vC to reach 7.2 V? Find t.
Vs = 9 VR = 2.2 kΩC = 220 µFvC(0) = 3 V
t = ms
9.AC impedance & phasorsMedium
A series RLC circuit with C = 1 µF must resonate at 5000 Hz. Find the inductance L needed.
f0 = 5000 HzC = 1 µF
L = mH
10.AC impedance & phasorsHard
A series RLC circuit is driven by a 24 V (rms) source whose frequency is set to the resonant frequency of the circuit. Find the rms voltage VL across the inductor.
V = 24 V (rms)R = 20 ΩL = 100 mHC = 2.2 µF
VL = V
11.AC power & power factorMedium
A load with impedance Z = 12 + j9 Ω is connected to a 120 V (rms) single-phase supply. Find the reactive power Q it absorbs.
V = 120 VZ = 12 + j9 Ω
Q = var
12.AC power & power factorHard
A single-phase load takes 35 kW at a power factor of 0.75 lagging from a 400 V, 50 Hz supply. A capacitor connected in parallel raises the power factor to 0.98. Find the reactive power QC the capacitor must supply.
P = 35 kWpf1 = 0.75pf2 = 0.98V = 400 Vf = 50 Hz
QC = kvar
13.Three-phase powerMedium
A three-phase induction motor delivers 11 kW of mechanical output power at full load. At this load its efficiency is 90% and its power factor is 0.9 lagging. The supply has a line-to-line voltage of 690 V. Find the line current IL.
Pout = 11 kWη = 90%cos φ = 0.9VL = 690 V
IL = A
14.Three-phase powerHard
A balanced three-phase load takes 80 kW at a power factor of 0.72 lagging from a 480 V (line-to-line), 60 Hz supply. A three-phase capacitor bank in parallel with the load must raise the overall power factor to 0.95 lagging. The real power stays the same. Find the total reactive power QC the capacitor bank must supply, in kvar.
P = 80 kWpf1 = 0.72pf2 = 0.95VL = 480 Vf = 60 Hz
QC = kvar
15.TransformersMedium
A 16 Ω resistor is connected across the secondary winding of an ideal transformer with a turns ratio N₁:N₂ = 6:1. Find the resistance R1′ seen looking into the primary winding.
N1:N2 = 6:1RL = 16 Ω
R1′ = Ω
16.TransformersHard
A single-phase 500 kVA transformer has a core loss of 1500 W and a copper loss of 2250 W at rated load. It supplies 75% of its rated kVA at a power factor of 0.8 lagging. Find the total losses Ploss in watts at this load.
Series and parallel resistors: in series the same current flows through each resistor and R = R₁ + R₂ + …. In parallel each resistor has the same voltage and 1/R = 1/R₁ + 1/R₂ + …. A ladder network is reduced one pair at a time until a single equivalent resistance remains.
Combine resistors from the far end
Start at the end farthest from the source and work back towards it. Resistors carrying the same current are in series; resistors across the same two nodes are in parallel.
R3 + R4 = 12 + 20 = 32 Ω
R2 ∥ 32 = 2·32/(2+32) = 1.882 Ω
Req = R1 + 1.882 = 4 + 1.882 = 5.882 Ω
Current from the source
The source sees only Req, so Ohm’s law gives the current it delivers. That current flows through R₁.
IR1 = V1/Req = 18/5.882 = 3.06 A
Answer
IR1 = 3.06 A
2.Series & parallel resistors
Answer: IR1 = 0.7736 A
Series and parallel resistors: in series the same current flows through each resistor and R = R₁ + R₂ + …. In parallel each resistor has the same voltage and 1/R = 1/R₁ + 1/R₂ + …. A ladder network is reduced one pair at a time until a single equivalent resistance remains.
Combine resistors from the far end
Start at the end farthest from the source and work back towards it. Resistors carrying the same current are in series; resistors across the same two nodes are in parallel.
R5 + R6 = 2 + 5 = 7 Ω
R4 ∥ 7 = 4.421 Ω
R3 + 4.421 = 9.421 Ω
R2 ∥ 9.421 = 3.266 Ω
Req = R1 + 3.266 = 20 + 3.266 = 23.27 Ω
Current from the source
The source sees only Req, so Ohm’s law gives the current it delivers. That current flows through R₁.
IR1 = V1/Req = 18/23.27 = 0.7736 A
Answer
IR1 = 0.7736 A
3.Nodal analysis
Answer: I2 = 0.3273 A
Nodal analysis: choose a reference node, label the unknown node voltages, write Kirchhoff’s current law at each unknown node using Ohm’s law (I = ΔV/R), and solve the resulting equations.
KCL at node A
Take the bottom wire as ground. Each branch carries (VA − Vk)/Rk away from A, where Vk is the voltage of its source (zero for a plain resistor). The currents leaving A add up to zero.
(VA − 6)/10 + (VA − 12)/5 + (VA − 12)/15 = 0
Solve for VA
VA = (6/10 + 12/5 + 12/15) / (1/10 + 1/5 + 1/15) = 3.8/0.3667 = 10.36 V
Branch current
The arrow points up through the branch, into node A.
I2 = (12 − VA)/R2 = (12 − 10.36)/5 = 0.3273 A
Answer
I2 = 0.3273 A
A negative result means the real current flows against the arrow.
4.Nodal analysis
Answer: VA = 4.375 V
Nodal analysis: choose a reference node, label the unknown node voltages, write Kirchhoff’s current law at each unknown node using Ohm’s law (I = ΔV/R), and solve the resulting equations.
KCL at node A
Currents leaving A through the resistors equal the current pushed into A by sources.
(VA − V1)/R1 + VA/R2 + (VA − VB)/R3 = 0
0.5417·VA − 0.125·VB = 1.667
KCL at node B
The dependent source pushes g·VA into node B. Treat it like an independent source, then move the VA term to the left-hand side.
(VB − VA)/R3 + VB/R4 = 0.1·VA
−0.225·VA + 0.175·VB = 0
Solve
Δ = (0.5417)(0.175) − (−0.125)(−0.225) = 0.06667
VA = Δ1/Δ = 0.2917/0.06667 = 4.375 V
VB = Δ2/Δ = 0.375/0.06667 = 5.625 V
Answer
VA = 4.375 V
5.Thévenin & Norton
Answer: Vth = 4.5 V
Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.
Find Rth with every source switched off
Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.
R1 ∥ R2 = 8·8/(8+8) = 4 Ω
Rth = (R1 ∥ R2) + R3 = 4 + 8 = 12 Ω
Find Vth, the open-circuit voltage
With a–b open, no current flows through R₃, so there is no drop across it and V_b = V_A. R₁ and R₂ form a voltage divider.
Vth = V1·R2/(R1+R2) = 9·8/(8+8) = 4.5 V
6.Thévenin & Norton
Answer: PL = 1.683 W
Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.
Find Rth with every source switched off
Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.
R1 ∥ R2 = 6·6/(6+6) = 3 Ω
Rth = (R1 ∥ R2) + R3 = 3 + 30 = 33 Ω
Find Vth, the open-circuit voltage
With a–b open, the only path for Iₛ is through R₃ into node A. Find V_A by superposition of V₁ and Iₛ, then add the drop across R₃.
VA = V1·R2/(R1+R2) + Is·(R1∥R2) = 9 + (−1)·3 = 6 V
Vth = VB = VA + Is·R3 = 6 + (−1)·30 = −24 V
Connect the load to the Thévenin equivalent
The Thévenin source and R_th in series behave exactly like the original circuit at a–b, so the load sees a simple series loop.
IL = Vth/(Rth + RL) = −24/(33 + 4) = −0.6486 A
PL = IL²·RL = −0.6486²·4 = 1.683 W
7.RC & RL transients
Answer: vL = 7.965 V
First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.
Time constant and final current
Long after the switch closes the inductor behaves like a short circuit, so the final current is set by R alone.
τ = L/R = 68 mH / 15 Ω = 4.533 ms
i(∞) = Vs/R = 24/15 = 1.6 A
Inductor voltage
At t = 0 the whole supply voltage appears across the inductor; it then decays to zero.
vL(t) = Vs·e−t/τ = 24·e−5/4.533 = 7.965 V
Answer
vL = 7.965 V
8.RC & RL transients
Answer: t = 582.7 ms
First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.
Initial value, final value, time constant
The capacitor voltage cannot jump, so it starts at its stored value and heads for the source voltage.
t = τ·ln((3 − 9)/(7.2 − 9)) = 484·ln(3.333) = 582.7 ms
Answer
t = 582.7 ms
9.AC impedance & phasors
Answer: L = 1.013 mH
AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.
Resonance condition
At resonance the inductive and capacitive reactances cancel: ωL = 1/(ωC).
ω₀ = 2π·5000 = 31416 rad/s
L = 1/(ω₀²·C) = 1/(31416²·1·10⁻⁶) = 1.013 mH
Answer
L = 1.013 mH
10.AC impedance & phasors
Answer: VL = 255.8 V
AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.
Resonance
At resonance the reactances cancel, so the impedance is just R.
ω₀ = 1/√(LC) = 1/√(0.1·2.2·10⁻⁶) = 2132 rad/s
I = V/R = 24/20 = 1.2 A
Voltage across the inductor
XL = ω₀L = 2132·0.1 = 213.2 Ω
VL = I·XL = 1.2·213.2 = 255.8 V
Answer
VL = 255.8 V
This is Q = 10.66 times the supply voltage.
11.AC power & power factor
Answer: Q = 576 var
AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.
Current
|Z| = √(12² + 9²) = 15 Ω
I = V/|Z| = 120/15 = 8 A
Reactive power
Q = I²·X = 8²·9 = 576 var
Answer
Q = 576 var
12.AC power & power factor
Answer: QC = 23.76 kvar
AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.
Reactive power before and after
The real power P does not change; only the reactive power drawn from the supply does.
Q1 = P·tan φ1 = 35·tan(41.41°) = 30.87 kvar
Q2 = P·tan φ2 = 35·tan(11.48°) = 7.107 kvar
QC = Q1 − Q2 = 23.76 kvar
Answer
QC = 23.76 kvar
13.Three-phase power
Answer: IL = 11.36 A
Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ.
Electrical input power
Pin = Pout/η = 11/0.9 = 12.22 kW
Line current
IL = Pin/(√3·VL·cos φ) = 12222/(√3·690·0.9) = 11.36 A
Answer
IL = 11.36 A
14.Three-phase power
Answer: QC = 50.81 kvar
Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ. Power factor correction: capacitors supply reactive power locally, QC = P·(tan φ1 − tan φ2). Each of the three capacitors supplies QC/3 = V²·ω·C, where V is the voltage across that capacitor: VL in a Δ bank, VL/√3 in a Y bank.
Reactive power before and after
The real power is unchanged, so each power factor fixes the reactive power: Q = P·tan φ.
Q1 = 80·tan(acos 0.72) = 80·0.9639 = 77.11 kvar
Q2 = 80·tan(acos 0.95) = 80·0.3287 = 26.29 kvar
Reactive power from the capacitors
QC = Q1 − Q2 = 50.81 kvar
Answer
QC = 50.81 kvar
15.Transformers
Answer: R1′ = 576 Ω
Ideal transformer: the voltages are in the ratio of the turns and the currents in the inverse ratio: V₁/V₂ = N₁/N₂ = a and I₁/I₂ = N₂/N₁ = 1/a, so the power in equals the power out, V₁·I₁ = V₂·I₂. A load impedance Z on the secondary looks like a²·Z from the primary.
Referred resistance
The voltage goes up by a and the current down by a, so the ratio V/I goes up by a².
R1′ = a²·RL = 6²·16 = 576 Ω
Answer
R1′ = 576 Ω
16.Transformers
Answer: Ploss = 2766 W
Transformer losses: the core loss (hysteresis and eddy currents) depends on the voltage and is the same at any load. The copper loss in the windings goes with the current squared, so at a fraction x of rated load it is x²·Pcu,fl. Efficiency η = Pout/(Pout + Pcore + Pcu), with Pout = x·S·pf. The efficiency is highest at the load where the copper loss equals the core loss.