The diamond is a voltage-controlled current source that pushes a current of 0.05·VA (in A, with VA in V) up into node B. Use nodal analysis to find the current IR4 through R4 in the direction of the arrow.
Find the Norton current IN: the current that flows from a to b if the terminals are shorted.
V1 = 10 VR1 = 12 ΩR2 = 2 ΩR3 = 8 Ω
IN = A
6.Thévenin & NortonHard
Find the Norton current IN: the current that flows from a to b if the terminals are shorted.
V1 = 12 VIs = 0.5 AR1 = 4 ΩR2 = 4 ΩR3 = 20 Ω
IN = A
7.RC & RL transientsMedium
The source Vₛ charges the capacitor through R₁, and R₂ is connected in parallel with C. The capacitor is uncharged when the switch closes at t = 0. Find the capacitor voltage vC at t = 80 ms.
Vs = 12 VR1 = 3.3 kΩR2 = 1 kΩC = 100 µFt = 80 ms
vC = V
8.RC & RL transientsHard
The switch across R2 has been open for a long time, so the inductor current is steady. At t = 0 the switch closes and shorts out R2. How long after t = 0 does the inductor current reach 0.417 A? Find t.
Vs = 9 VR1 = 10 ΩR2 = 33 ΩL = 150 mH
t = ms
9.AC impedance & phasorsMedium
A series RLC circuit is connected to a 120 V (rms), 1000 Hz supply. Find the rms current I.
V = 120 V (rms)f = 1000 HzR = 80 ΩL = 200 mHC = 100 µF
I = A
10.AC impedance & phasorsHard
A series RLC circuit has R = 10 Ω, L = 1 mH and C = 1 µF. Find its bandwidth B (the width of the band between the half-power frequencies), in Hz.
R = 10 ΩL = 1 mHC = 1 µF
B = Hz
11.AC power & power factorMedium
A single-phase motor takes 31 kW at a power factor of 0.8 lagging from a 400 V supply. Find the line current I.
P = 31 kWpf = 0.8V = 400 V
I = A
12.AC power & power factorHard
A single-phase load takes 25 kW at a power factor of 0.6 lagging from a 230 V, 50 Hz supply. A capacitor connected in parallel raises the power factor to 0.95. Find the reactive power QC the capacitor must supply.
P = 25 kWpf1 = 0.6pf2 = 0.95V = 230 Vf = 50 Hz
QC = kvar
13.Three-phase powerMedium
A three-phase induction motor delivers 11 kW of mechanical output power at full load. At this load its efficiency is 93% and its power factor is 0.8 lagging. The supply has a line-to-line voltage of 400 V. Find the line current IL.
Pout = 11 kWη = 93%cos φ = 0.8VL = 400 V
IL = A
14.Three-phase powerHard
A balanced three-phase load takes 250 kW at a power factor of 0.65 lagging from a 400 V (line-to-line), 60 Hz supply. A three-phase capacitor bank in parallel with the load must raise the overall power factor to 0.92 lagging. The real power stays the same. Find the total reactive power QC the capacitor bank must supply, in kvar.
P = 250 kWpf1 = 0.65pf2 = 0.92VL = 400 Vf = 60 Hz
QC = kvar
15.TransformersMedium
A single-phase 25 kVA, 2400/240 V transformer operates at its rated load. Treat it as ideal. Find the current ILV in the low-voltage winding.
S = 25 kVAV1 = 2400 VV2 = 240 V
ILV = A
16.TransformersHard
A single-phase 250 kVA transformer has a core loss of 2000 W and a copper loss of 5000 W at rated load. It supplies 50% of its rated kVA at a power factor of 0.8 lagging. Find the total losses Ploss in watts at this load.
Series and parallel resistors: in series the same current flows through each resistor and R = R₁ + R₂ + …. In parallel each resistor has the same voltage and 1/R = 1/R₁ + 1/R₂ + …. A ladder network is reduced one pair at a time until a single equivalent resistance remains.
Combine resistors from the far end
Start at the end farthest from the source and work back towards it. Resistors carrying the same current are in series; resistors across the same two nodes are in parallel.
R3 + R4 = 15 + 12 = 27 Ω
R2 ∥ 27 = 5·27/(5+27) = 4.219 Ω
Req = R1 + 4.219 = 20 + 4.219 = 24.22 Ω
Current from the source
The source sees only Req, so Ohm’s law gives the current it delivers. That current flows through R₁.
IR1 = V1/Req = 18/24.22 = 0.7432 A
Current through R₂
Subtract the drop across R₁ to get the voltage at node A, which is the voltage across R₂.
VA = V1 − IR1·R1 = 18 − 0.7432·20 = 3.135 V
IR2 = VA/R2 = 3.135/5 = 0.6271 A
Answer
IR2 = 0.6271 A
2.Series & parallel resistors
Answer: Req = 13.63 Ω
Series and parallel resistors: in series the same current flows through each resistor and R = R₁ + R₂ + …. In parallel each resistor has the same voltage and 1/R = 1/R₁ + 1/R₂ + …. A ladder network is reduced one pair at a time until a single equivalent resistance remains.
Combine resistors from the far end
Start at the end farthest from the source and work back towards it. Resistors carrying the same current are in series; resistors across the same two nodes are in parallel.
R5 + R6 = 10 + 2 = 12 Ω
R4 ∥ 12 = 4.8 Ω
R3 + 4.8 = 8.8 Ω
R2 ∥ 8.8 = 1.63 Ω
Req = R1 + 1.63 = 12 + 1.63 = 13.63 Ω
Answer
Req = 13.63 Ω
3.Nodal analysis
Answer: IR3 = −0.24 A
Nodal analysis: choose a reference node, label the unknown node voltages, write Kirchhoff’s current law at each unknown node using Ohm’s law (I = ΔV/R), and solve the resulting equations.
Set up the nodes
Ground is the bottom wire. Known node voltages come straight from the sources (V1 = 18 V). Unknowns: VA, VB.
KCL at node A
Currents leaving A through the resistors equal the current pushed into A by sources.
VA/R2 + (VA − V1)/R1 + (VA − VB)/R3 = 0
VA/10 + (VA − 18)/10 + (VA − VB)/10 = 0
0.3·VA − 0.1·VB = 1.8
KCL at node B
Currents leaving B through the resistors equal the current pushed into B by sources.
VB/R4 + (VB − VA)/R3 = Is
VB/10 + (VB − VA)/10 = 1.5
−0.1·VA + 0.2·VB = 1.5
Solve
Δ = (0.3)(0.2) − (−0.1)(−0.1) = 0.05
VA = Δ1/Δ = 0.51/0.05 = 10.2 V
VB = Δ2/Δ = 0.63/0.05 = 12.6 V
Answer
IR3 = (VA − VB)/R3 = (10.2 − 12.6)/10 = −0.24 A
4.Nodal analysis
Answer: IR4 = 2.043 A
Nodal analysis: choose a reference node, label the unknown node voltages, write Kirchhoff’s current law at each unknown node using Ohm’s law (I = ΔV/R), and solve the resulting equations.
KCL at node A
Currents leaving A through the resistors equal the current pushed into A by sources.
(VA − V1)/R1 + VA/R2 + (VA − VB)/R3 = 0
1.167·VA − 0.3333·VB = 9
KCL at node B
The dependent source pushes g·VA into node B. Treat it like an independent source, then move the VA term to the left-hand side.
(VB − VA)/R3 + VB/R4 = 0.05·VA
−0.3833·VA + 0.8333·VB = 0
Solve
Δ = (1.167)(0.8333) − (−0.3333)(−0.3833) = 0.8444
VA = Δ1/Δ = 7.5/0.8444 = 8.882 V
VB = Δ2/Δ = 3.45/0.8444 = 4.086 V
Current through R₄
IR4 = VB/R4 = 4.086/2 = 2.043 A
Answer
IR4 = 2.043 A
5.Thévenin & Norton
Answer: IN = 0.1471 A
Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.
Find Rth with every source switched off
Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.
R1 ∥ R2 = 12·2/(12+2) = 1.714 Ω
Rth = (R1 ∥ R2) + R3 = 1.714 + 8 = 9.714 Ω
Find Vth, the open-circuit voltage
With a–b open, no current flows through R₃, so there is no drop across it and V_b = V_A. R₁ and R₂ form a voltage divider.
Vth = V1·R2/(R1+R2) = 10·2/(12+2) = 1.429 V
Norton equivalent
A Norton source is the same circuit seen as a current source in parallel with R_th. Its current is the short-circuit current at a–b.
IN = Vth/Rth = 1.429/9.714 = 0.1471 A
6.Thévenin & Norton
Answer: IN = 0.7727 A
Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.
Find Rth with every source switched off
Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.
R1 ∥ R2 = 4·4/(4+4) = 2 Ω
Rth = (R1 ∥ R2) + R3 = 2 + 20 = 22 Ω
Find Vth, the open-circuit voltage
With a–b open, the only path for Iₛ is through R₃ into node A. Find V_A by superposition of V₁ and Iₛ, then add the drop across R₃.
VA = V1·R2/(R1+R2) + Is·(R1∥R2) = 6 + 0.5·2 = 7 V
Vth = VB = VA + Is·R3 = 7 + 0.5·20 = 17 V
Norton equivalent
A Norton source is the same circuit seen as a current source in parallel with R_th. Its current is the short-circuit current at a–b.
IN = Vth/Rth = 17/22 = 0.7727 A
7.RC & RL transients
Answer: vC = 1.807 V
First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.
Thévenin equivalent seen by the capacitor
Short the source to find Rth; open the capacitor to find the voltage it will settle at.
Rth = R1 ∥ R2 = 3.3·1/(3.3 + 1) = 0.7674 kΩ
vC(∞) = 12·1/(3.3 + 1) = 2.791 V
Time constant
τ = Rth·C = 0.7674·100 = 76.74 ms
Charging curve
vC(t) = 2.791·(1 − e−80/76.74) = 1.807 V
Answer
vC = 1.807 V
8.RC & RL transients
Answer: t = 5.365 ms
First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.
Initial value, final value, time constant
Before t = 0 both resistors are in the loop; afterwards the closed switch bypasses R₂.
i(0) = 9/(10 + 33) = 0.2093 A
i(∞) = 9/10 = 0.9 A
τ = L/R = 150/10 = 15 ms
i(t) = 0.9 + (0.2093 − 0.9)·e−t/τ
Solve for the time
e−t/τ = (0.417 − 0.9)/(0.2093 − 0.9) = 0.6993
t = 15·ln(1.43) = 5.365 ms
Answer
t = 5.365 ms
9.AC impedance & phasors
Answer: I = 0.09542 A
AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.
Reactances
ω = 2πf = 2π·1000 = 6283 rad/s
XL = ωL = 6283·0.2 = 1257 Ω
XC = 1/(ωC) = 1/(6283·100·10⁻⁶) = 1.592 Ω
Impedance
In series the impedances add as complex numbers: Z = R + j(XL − XC).
The same current flows through every element of a series circuit.
I = V/|Z| = 120/1258 = 0.09542 A
Answer
I = 0.09542 A
10.AC impedance & phasors
Answer: B = 1592 Hz
AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.
Resonant frequency
f0 = 1/(2π·√(0.001·1·10⁻⁶)) = 5033 Hz
Quality factor
Q compares the reactance at resonance with the resistance: Q = ω₀L/R.
AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.
Line current
Only the real part of the power does work, so divide by the power factor.
I = P/(V·cos φ) = 31000/(400·0.8) = 96.88 A
Answer
I = 96.88 A
12.AC power & power factor
Answer: QC = 25.12 kvar
AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.
Reactive power before and after
The real power P does not change; only the reactive power drawn from the supply does.
Q1 = P·tan φ1 = 25·tan(53.13°) = 33.33 kvar
Q2 = P·tan φ2 = 25·tan(18.19°) = 8.217 kvar
QC = Q1 − Q2 = 25.12 kvar
Answer
QC = 25.12 kvar
13.Three-phase power
Answer: IL = 21.34 A
Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ.
Electrical input power
Pin = Pout/η = 11/0.93 = 11.83 kW
Line current
IL = Pin/(√3·VL·cos φ) = 11828/(√3·400·0.8) = 21.34 A
Answer
IL = 21.34 A
14.Three-phase power
Answer: QC = 185.8 kvar
Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ. Power factor correction: capacitors supply reactive power locally, QC = P·(tan φ1 − tan φ2). Each of the three capacitors supplies QC/3 = V²·ω·C, where V is the voltage across that capacitor: VL in a Δ bank, VL/√3 in a Y bank.
Reactive power before and after
The real power is unchanged, so each power factor fixes the reactive power: Q = P·tan φ.
Q1 = 250·tan(acos 0.65) = 250·1.169 = 292.3 kvar
Q2 = 250·tan(acos 0.92) = 250·0.426 = 106.5 kvar
Reactive power from the capacitors
QC = Q1 − Q2 = 185.8 kvar
Answer
QC = 185.8 kvar
15.Transformers
Answer: ILV = 104.2 A
Ideal transformer: the voltages are in the ratio of the turns and the currents in the inverse ratio: V₁/V₂ = N₁/N₂ = a and I₁/I₂ = N₂/N₁ = 1/a, so the power in equals the power out, V₁·I₁ = V₂·I₂. A load impedance Z on the secondary looks like a²·Z from the primary.
Rated current
Both windings carry the same apparent power.
ILV = S/V = 25000/240 = 104.2 A
Answer
ILV = 104.2 A
16.Transformers
Answer: Ploss = 3250 W
Transformer losses: the core loss (hysteresis and eddy currents) depends on the voltage and is the same at any load. The copper loss in the windings goes with the current squared, so at a fraction x of rated load it is x²·Pcu,fl. Efficiency η = Pout/(Pout + Pcore + Pcu), with Pout = x·S·pf. The efficiency is highest at the load where the copper loss equals the core loss.