The diamond is a voltage-controlled current source that pushes a current of 0.1·VA (in A, with VA in V) up into node B. Use nodal analysis to find the current IR4 through R4 in the direction of the arrow.
Find the Thévenin resistance Rth seen from terminals a–b.
V1 = 6 VR1 = 3 ΩR2 = 6 ΩR3 = 4 Ω
Rth = Ω
6.Thévenin & NortonHard
Find the Norton current IN: the current that flows from a to b if the terminals are shorted.
V1 = 24 VIs = 3 AR1 = 4 ΩR2 = 10 ΩR3 = 15 Ω
IN = A
7.RC & RL transientsMedium
The inductor carries no current before the switch closes at t = 0. Find the voltage vL across the inductor at t = 10 ms.
Vs = 6 VR = 33 ΩL = 150 mHt = 10 ms
vL = V
8.RC & RL transientsHard
Just before the switch closes at t = 0, the capacitor holds 3 V with the polarity shown. Find the capacitor voltage vC at t = 20 ms.
Vs = 9 VR = 1 kΩC = 33 µFvC(0) = 3 Vt = 20 ms
vC = V
9.AC impedance & phasorsMedium
A series RLC circuit is connected to a 50 V (rms), 50 Hz supply. Find the power factor cos φ of the circuit.
V = 50 V (rms)f = 50 HzR = 40 ΩL = 250 mHC = 10 µF
cos φ =
10.AC impedance & phasorsHard
A series RLC circuit has R = 50 Ω, L = 100 mH and C = 0.022 µF. Find its quality factor Q at resonance.
R = 50 ΩL = 100 mHC = 0.022 µF
Q =
11.AC power & power factorMedium
A single-phase motor takes 29 kW at a power factor of 0.7 lagging from a 240 V supply. Find the reactive power Q it draws.
P = 29 kWpf = 0.7V = 240 V
Q = kvar
12.AC power & power factorHard
A single-phase load takes 10 kW at a power factor of 0.65 lagging from a 240 V, 60 Hz supply. A capacitor connected in parallel raises the power factor to 0.95. Find the capacitance C needed.
P = 10 kWpf1 = 0.65pf2 = 0.95V = 240 Vf = 60 Hz
C = µF
13.Three-phase powerMedium
A three-phase induction motor delivers 55 kW of mechanical output power at full load. At this load its efficiency is 92% and its power factor is 0.9 lagging. The supply has a line-to-line voltage of 480 V. Find the line current IL.
Pout = 55 kWη = 92%cos φ = 0.9VL = 480 V
IL = A
14.Three-phase powerHard
A balanced three-phase load takes 200 kW at a power factor of 0.75 lagging from a 480 V (line-to-line), 50 Hz supply. A three-phase capacitor bank in parallel with the load must raise the overall power factor to 0.98 lagging. The real power stays the same. The capacitors are connected in Δ. Find the capacitance Cph of each capacitor in µF.
P = 200 kWpf1 = 0.75pf2 = 0.98VL = 480 Vf = 50 Hz
Cph = µF
15.TransformersMedium
A 10 Ω resistor is connected across the secondary winding of an ideal transformer with a turns ratio N₁:N₂ = 6:1. Find the resistance R1′ seen looking into the primary winding.
N1:N2 = 6:1RL = 10 Ω
R1′ = Ω
16.TransformersHard
A single-phase 100 kVA transformer has a core loss of 300 W and a copper loss of 450 W at rated load. At what load Sη,max, in kVA, is its efficiency highest?
S = 100 kVAPcore = 300 WPcu,fl = 450 W
Sη,max = kVA
3Solutions
1.Series & parallel resistors
Answer: IR2 = 1.929 A
Series and parallel resistors: in series the same current flows through each resistor and R = R₁ + R₂ + …. In parallel each resistor has the same voltage and 1/R = 1/R₁ + 1/R₂ + …. A ladder network is reduced one pair at a time until a single equivalent resistance remains.
Combine resistors from the far end
Start at the end farthest from the source and work back towards it. Resistors carrying the same current are in series; resistors across the same two nodes are in parallel.
R3 + R4 = 6 + 3 = 9 Ω
R2 ∥ 9 = 6·9/(6+9) = 3.6 Ω
Req = R1 + 3.6 = 2 + 3.6 = 5.6 Ω
Current from the source
The source sees only Req, so Ohm’s law gives the current it delivers. That current flows through R₁.
IR1 = V1/Req = 18/5.6 = 3.214 A
Current through R₂
Subtract the drop across R₁ to get the voltage at node A, which is the voltage across R₂.
VA = V1 − IR1·R1 = 18 − 3.214·2 = 11.57 V
IR2 = VA/R2 = 11.57/6 = 1.929 A
Answer
IR2 = 1.929 A
2.Series & parallel resistors
Answer: IR2 = 0.1711 A
Series and parallel resistors: in series the same current flows through each resistor and R = R₁ + R₂ + …. In parallel each resistor has the same voltage and 1/R = 1/R₁ + 1/R₂ + …. A ladder network is reduced one pair at a time until a single equivalent resistance remains.
Combine resistors from the far end
Start at the end farthest from the source and work back towards it. Resistors carrying the same current are in series; resistors across the same two nodes are in parallel.
R5 + R6 = 3 + 20 = 23 Ω
R4 ∥ 23 = 2.654 Ω
R3 + 2.654 = 22.65 Ω
R2 ∥ 22.65 = 10.62 Ω
Req = R1 + 10.62 = 8 + 10.62 = 18.62 Ω
Current from the source
The source sees only Req, so Ohm’s law gives the current it delivers. That current flows through R₁.
IR1 = V1/Req = 6/18.62 = 0.3222 A
Current through R₂
Subtract the drop across R₁ to get the voltage at node A, which is the voltage across R₂.
VA = V1 − IR1·R1 = 6 − 0.3222·8 = 3.422 V
IR2 = VA/R2 = 3.422/20 = 0.1711 A
Answer
IR2 = 0.1711 A
3.Nodal analysis
Answer: VA = 10.43 V
Nodal analysis: choose a reference node, label the unknown node voltages, write Kirchhoff’s current law at each unknown node using Ohm’s law (I = ΔV/R), and solve the resulting equations.
Set up the nodes
Ground is the bottom wire. Known node voltages come straight from the sources (V1 = 15 V). Unknowns: VA, VB.
KCL at node A
Currents leaving A through the resistors equal the current pushed into A by sources.
VA/R2 + (VA − V1)/R1 + (VA − VB)/R3 = 0
VA/4 + (VA − 15)/3 + (VA − VB)/3 = 0
0.9167·VA − 0.3333·VB = 5
KCL at node B
Currents leaving B through the resistors equal the current pushed into B by sources.
VB/R4 + (VB − VA)/R3 = Is
VB/15 + (VB − VA)/3 = 2
−0.3333·VA + 0.4·VB = 2
Solve
Δ = (0.9167)(0.4) − (−0.3333)(−0.3333) = 0.2556
VA = Δ1/Δ = 2.667/0.2556 = 10.43 V
VB = Δ2/Δ = 3.5/0.2556 = 13.7 V
Answer
VA = 10.43 V
4.Nodal analysis
Answer: IR4 = 0.4305 A
Nodal analysis: choose a reference node, label the unknown node voltages, write Kirchhoff’s current law at each unknown node using Ohm’s law (I = ΔV/R), and solve the resulting equations.
KCL at node A
Currents leaving A through the resistors equal the current pushed into A by sources.
(VA − V1)/R1 + VA/R2 + (VA − VB)/R3 = 0
0.35·VA − 0.03333·VB = 1.2
KCL at node B
The dependent source pushes g·VA into node B. Treat it like an independent source, then move the VA term to the left-hand side.
(VB − VA)/R3 + VB/R4 = 0.1·VA
−0.1333·VA + 0.3667·VB = 0
Solve
Δ = (0.35)(0.3667) − (−0.03333)(−0.1333) = 0.1239
VA = Δ1/Δ = 0.44/0.1239 = 3.552 V
VB = Δ2/Δ = 0.16/0.1239 = 1.291 V
Current through R₄
IR4 = VB/R4 = 1.291/3 = 0.4305 A
Answer
IR4 = 0.4305 A
5.Thévenin & Norton
Answer: Rth = 6 Ω
Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.
Find Rth with every source switched off
Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.
R1 ∥ R2 = 3·6/(3+6) = 2 Ω
Rth = (R1 ∥ R2) + R3 = 2 + 4 = 6 Ω
6.Thévenin & Norton
Answer: IN = 3.96 A
Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.
Find Rth with every source switched off
Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.
R1 ∥ R2 = 4·10/(4+10) = 2.857 Ω
Rth = (R1 ∥ R2) + R3 = 2.857 + 15 = 17.86 Ω
Find Vth, the open-circuit voltage
With a–b open, the only path for Iₛ is through R₃ into node A. Find V_A by superposition of V₁ and Iₛ, then add the drop across R₃.
VA = V1·R2/(R1+R2) + Is·(R1∥R2) = 17.14 + 3·2.857 = 25.71 V
Vth = VB = VA + Is·R3 = 25.71 + 3·15 = 70.71 V
Norton equivalent
A Norton source is the same circuit seen as a current source in parallel with R_th. Its current is the short-circuit current at a–b.
IN = Vth/Rth = 70.71/17.86 = 3.96 A
7.RC & RL transients
Answer: vL = 0.6648 V
First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.
Time constant and final current
Long after the switch closes the inductor behaves like a short circuit, so the final current is set by R alone.
τ = L/R = 150 mH / 33 Ω = 4.545 ms
i(∞) = Vs/R = 6/33 = 0.1818 A
Inductor voltage
At t = 0 the whole supply voltage appears across the inductor; it then decays to zero.
vL(t) = Vs·e−t/τ = 6·e−10/4.545 = 0.6648 V
Answer
vL = 0.6648 V
8.RC & RL transients
Answer: vC = 5.727 V
First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.
Initial value, final value, time constant
The capacitor voltage cannot jump, so it starts at its stored value and heads for the source voltage.
vC(0) = 3 V, vC(∞) = Vs = 9 V
τ = R·C = 1 kΩ · 33 µF = 33 ms
vC(t) = 9 + (3 − 9)·e−t/τ
Voltage at the given time
vC(20) = 9 + (−6)·e−20/33 = 5.727 V
Answer
vC = 5.727 V
9.AC impedance & phasors
Answer: cos φ = 0.1646
AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.
Reactances
XL = 78.54 Ω, XC = 318.3 Ω
Impedance
|Z| = √(40² + (−239.8)²) = 243.1 Ω
Power factor
cos φ = R/|Z| = 40/243.1 = 0.1646
The circuit is capacitive, so the power factor is leading.
Answer
cos φ = 0.1646
10.AC impedance & phasors
Answer: Q = 42.64
AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.
Resonant frequency
f0 = 1/(2π·√(0.1·0.022·10⁻⁶)) = 3393 Hz
Quality factor
Q compares the reactance at resonance with the resistance: Q = ω₀L/R.
AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.
Angle
φ = arccos(0.7) = 45.57°, tan φ = 1.02
Reactive power
Q = P·tan φ = 29·1.02 = 29.59 kvar
Answer
Q = 29.59 kvar
12.AC power & power factor
Answer: C = 387 µF
AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.
Reactive power before and after
The real power P does not change; only the reactive power drawn from the supply does.
Q1 = P·tan φ1 = 10·tan(49.46°) = 11.69 kvar
Q2 = P·tan φ2 = 10·tan(18.19°) = 3.287 kvar
QC = Q1 − Q2 = 8.404 kvar
Capacitance
A capacitor across the supply delivers Q = V²·ωC.
C = QC/(2πf·V²) = 8404/(2π·60·240²) = 387 µF
Answer
C = 387 µF
13.Three-phase power
Answer: IL = 79.9 A
Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ.
Electrical input power
Pin = Pout/η = 55/0.92 = 59.78 kW
Line current
IL = Pin/(√3·VL·cos φ) = 59783/(√3·480·0.9) = 79.9 A
Answer
IL = 79.9 A
14.Three-phase power
Answer: Cph = 625.3 µF
Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ. Power factor correction: capacitors supply reactive power locally, QC = P·(tan φ1 − tan φ2). Each of the three capacitors supplies QC/3 = V²·ω·C, where V is the voltage across that capacitor: VL in a Δ bank, VL/√3 in a Y bank.
Reactive power before and after
The real power is unchanged, so each power factor fixes the reactive power: Q = P·tan φ.
Q1 = 200·tan(acos 0.75) = 200·0.8819 = 176.4 kvar
Q2 = 200·tan(acos 0.98) = 200·0.2031 = 40.61 kvar
Reactive power from the capacitors
QC = Q1 − Q2 = 135.8 kvar
Capacitance per phase
In a Δ bank each capacitor is connected between two lines.
Ideal transformer: the voltages are in the ratio of the turns and the currents in the inverse ratio: V₁/V₂ = N₁/N₂ = a and I₁/I₂ = N₂/N₁ = 1/a, so the power in equals the power out, V₁·I₁ = V₂·I₂. A load impedance Z on the secondary looks like a²·Z from the primary.
Referred resistance
The voltage goes up by a and the current down by a, so the ratio V/I goes up by a².
R1′ = a²·RL = 6²·10 = 360 Ω
Answer
R1′ = 360 Ω
16.Transformers
Answer: Sη,max = 81.65 kVA
Transformer losses: the core loss (hysteresis and eddy currents) depends on the voltage and is the same at any load. The copper loss in the windings goes with the current squared, so at a fraction x of rated load it is x²·Pcu,fl. Efficiency η = Pout/(Pout + Pcore + Pcu), with Pout = x·S·pf. The efficiency is highest at the load where the copper loss equals the core loss.