The inductor carries no current before the switch closes at t = 0. Find the voltage vL across the inductor at t = 5 ms.
Vs = 10 VR = 22 ΩL = 100 mHt = 5 ms
vL = V
8.RC & RL transientsHard
Just before the switch closes at t = 0, the capacitor holds 6 V with the polarity shown. How long does it take for vC to reach 11.4 V? Find t.
Vs = 24 VR = 6.8 kΩC = 47 µFvC(0) = 6 V
t = ms
9.AC impedance & phasorsMedium
A series RLC circuit with C = 47 µF must resonate at 50 Hz. Find the inductance L needed.
f0 = 50 HzC = 47 µF
L = mH
10.AC impedance & phasorsHard
A series RLC circuit has R = 20 Ω, L = 20 mH and C = 2.2 µF. Find its quality factor Q at resonance.
R = 20 ΩL = 20 mHC = 2.2 µF
Q =
11.AC power & power factorMedium
A single-phase motor takes 15 kW at a power factor of 0.75 lagging from a 230 V supply. Find the line current I.
P = 15 kWpf = 0.75V = 230 V
I = A
12.AC power & power factorHard
A single-phase load takes 40 kW at a power factor of 0.65 lagging from a 240 V, 60 Hz supply. A capacitor connected in parallel raises the power factor to 0.98. Find the capacitance C needed.
P = 40 kWpf1 = 0.65pf2 = 0.98V = 240 Vf = 60 Hz
C = µF
13.Three-phase powerMedium
A balanced Y-connected load with an impedance of 7 + j24 Ω per phase is connected to a balanced three-phase supply with a line-to-line voltage of 480 V. Find the total real power P absorbed by the load in kW.
VL = 480 VZ = 7 + j24 Ω per phase
P = kW
14.Three-phase powerHard
A balanced three-phase load takes 150 kW at a power factor of 0.78 lagging from a 690 V (line-to-line), 50 Hz supply. A three-phase capacitor bank in parallel with the load must raise the overall power factor to 0.98 lagging. The real power stays the same. The capacitors are connected in Y. Find the capacitance Cph of each capacitor in µF.
P = 150 kWpf1 = 0.78pf2 = 0.98VL = 690 Vf = 50 Hz
Cph = µF
15.TransformersMedium
A single-phase 25 kVA, 4160/480 V transformer operates at its rated load. Treat it as ideal. Find the current IHV in the high-voltage winding.
S = 25 kVAV1 = 4160 VV2 = 480 V
IHV = A
16.TransformersHard
A single-phase 200 kVA transformer has a core loss of 800 W and a copper loss of 2400 W at rated load. It supplies 25% of its rated kVA at a power factor of 0.95 lagging. Find the total losses Ploss in watts at this load.
Series and parallel resistors: in series the same current flows through each resistor and R = R₁ + R₂ + …. In parallel each resistor has the same voltage and 1/R = 1/R₁ + 1/R₂ + …. A ladder network is reduced one pair at a time until a single equivalent resistance remains.
Combine resistors from the far end
Start at the end farthest from the source and work back towards it. Resistors carrying the same current are in series; resistors across the same two nodes are in parallel.
R3 + R4 = 6 + 3 = 9 Ω
R2 ∥ 9 = 2·9/(2+9) = 1.636 Ω
Req = R1 + 1.636 = 2 + 1.636 = 3.636 Ω
Current from the source
The source sees only Req, so Ohm’s law gives the current it delivers. That current flows through R₁.
IR1 = V1/Req = 6/3.636 = 1.65 A
Answer
IR1 = 1.65 A
2.Series & parallel resistors
Answer: Req = 9.174 Ω
Series and parallel resistors: in series the same current flows through each resistor and R = R₁ + R₂ + …. In parallel each resistor has the same voltage and 1/R = 1/R₁ + 1/R₂ + …. A ladder network is reduced one pair at a time until a single equivalent resistance remains.
Combine resistors from the far end
Start at the end farthest from the source and work back towards it. Resistors carrying the same current are in series; resistors across the same two nodes are in parallel.
R5 + R6 = 30 + 30 = 60 Ω
R4 ∥ 60 = 7.059 Ω
R3 + 7.059 = 27.06 Ω
R2 ∥ 27.06 = 6.174 Ω
Req = R1 + 6.174 = 3 + 6.174 = 9.174 Ω
Answer
Req = 9.174 Ω
3.Nodal analysis
Answer: VB = 19.44 V
Nodal analysis: choose a reference node, label the unknown node voltages, write Kirchhoff’s current law at each unknown node using Ohm’s law (I = ΔV/R), and solve the resulting equations.
Set up the nodes
Ground is the bottom wire. Known node voltages come straight from the sources (V1 = 10 V). Unknowns: VA, VB.
KCL at node A
Currents leaving A through the resistors equal the current pushed into A by sources.
VA/R2 + (VA − V1)/R1 + (VA − VB)/R3 = 0
VA/15 + (VA − 10)/2 + (VA − VB)/5 = 0
0.7667·VA − 0.2·VB = 5
KCL at node B
Currents leaving B through the resistors equal the current pushed into B by sources.
VB/R4 + (VB − VA)/R3 = Is
VB/8 + (VB − VA)/5 = 4
−0.2·VA + 0.325·VB = 4
Solve
Δ = (0.7667)(0.325) − (−0.2)(−0.2) = 0.2092
VA = Δ1/Δ = 2.425/0.2092 = 11.59 V
VB = Δ2/Δ = 4.067/0.2092 = 19.44 V
Answer
VB = 19.44 V
4.Nodal analysis
Answer: IR4 = −0.251 A
Nodal analysis: choose a reference node, label the unknown node voltages, write Kirchhoff’s current law at each unknown node using Ohm’s law (I = ΔV/R), and solve the resulting equations.
Set up the nodes
Ground is the bottom wire. Known node voltages come straight from the sources (V1 = 36 V, V2 = 24 V). Unknowns: VA, VB.
KCL at node A
Currents leaving A through the resistors equal the current pushed into A by sources.
VA/R3 + (VA − V1)/R1 + (VA − VB)/R2 = 0
VA/4 + (VA − 36)/2 + (VA − VB)/8 = 0
0.875·VA − 0.125·VB = 18
KCL at node B
Currents leaving B through the resistors equal the current pushed into B by sources.
VB/R5 + (VB − VA)/R2 + (VB − V2)/R4 = Is
VB/15 + (VB − VA)/8 + (VB − 24)/8 = 1
−0.125·VA + 0.3167·VB = 4
Solve
Δ = (0.875)(0.3167) − (−0.125)(−0.125) = 0.2615
VA = Δ1/Δ = 6.2/0.2615 = 23.71 V
VB = Δ2/Δ = 5.75/0.2615 = 21.99 V
Answer
IR4 = (VB − V2)/R4 = (21.99 − 24)/8 = −0.251 A
5.Thévenin & Norton
Answer: Vth = 4.286 V
Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.
Find Rth with every source switched off
Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.
R1 ∥ R2 = 10·4/(10+4) = 2.857 Ω
Rth = (R1 ∥ R2) + R3 = 2.857 + 12 = 14.86 Ω
Find Vth, the open-circuit voltage
With a–b open, no current flows through R₃, so there is no drop across it and V_b = V_A. R₁ and R₂ form a voltage divider.
Vth = V1·R2/(R1+R2) = 15·4/(10+4) = 4.286 V
6.Thévenin & Norton
Answer: PL = 12.59 W
Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.
Find Rth with every source switched off
Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.
R1 ∥ R2 = 4·30/(4+30) = 3.529 Ω
Rth = (R1 ∥ R2) + R3 = 3.529 + 12 = 15.53 Ω
Find Vth, the open-circuit voltage
With a–b open, the only path for Iₛ is through R₃ into node A. Find V_A by superposition of V₁ and Iₛ, then add the drop across R₃.
VA = V1·R2/(R1+R2) + Is·(R1∥R2) = 13.24 + 1·3.529 = 16.76 V
Vth = VB = VA + Is·R3 = 16.76 + 1·12 = 28.76 V
Connect the load to the Thévenin equivalent
The Thévenin source and R_th in series behave exactly like the original circuit at a–b, so the load sees a simple series loop.
IL = Vth/(Rth + RL) = 28.76/(15.53 + 25) = 0.7097 A
PL = IL²·RL = 0.7097²·25 = 12.59 W
7.RC & RL transients
Answer: vL = 3.329 V
First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.
Time constant and final current
Long after the switch closes the inductor behaves like a short circuit, so the final current is set by R alone.
τ = L/R = 100 mH / 22 Ω = 4.545 ms
i(∞) = Vs/R = 10/22 = 0.4545 A
Inductor voltage
At t = 0 the whole supply voltage appears across the inductor; it then decays to zero.
vL(t) = Vs·e−t/τ = 10·e−5/4.545 = 3.329 V
Answer
vL = 3.329 V
8.RC & RL transients
Answer: t = 114 ms
First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.
Initial value, final value, time constant
The capacitor voltage cannot jump, so it starts at its stored value and heads for the source voltage.
t = τ·ln((6 − 24)/(11.4 − 24)) = 319.6·ln(1.429) = 114 ms
Answer
t = 114 ms
9.AC impedance & phasors
Answer: L = 215.6 mH
AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.
Resonance condition
At resonance the inductive and capacitive reactances cancel: ωL = 1/(ωC).
ω₀ = 2π·50 = 314.2 rad/s
L = 1/(ω₀²·C) = 1/(314.2²·47·10⁻⁶) = 215.6 mH
Answer
L = 215.6 mH
10.AC impedance & phasors
Answer: Q = 4.767
AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.
Resonant frequency
f0 = 1/(2π·√(0.02·2.2·10⁻⁶)) = 758.7 Hz
Quality factor
Q compares the reactance at resonance with the resistance: Q = ω₀L/R.
AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.
Line current
Only the real part of the power does work, so divide by the power factor.
I = P/(V·cos φ) = 15000/(230·0.75) = 86.96 A
Answer
I = 86.96 A
12.AC power & power factor
Answer: C = 1780 µF
AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.
Reactive power before and after
The real power P does not change; only the reactive power drawn from the supply does.
Q1 = P·tan φ1 = 40·tan(49.46°) = 46.77 kvar
Q2 = P·tan φ2 = 40·tan(11.48°) = 8.122 kvar
QC = Q1 − Q2 = 38.64 kvar
Capacitance
A capacitor across the supply delivers Q = V²·ωC.
C = QC/(2πf·V²) = 38643/(2π·60·240²) = 1780 µF
Answer
C = 1780 µF
13.Three-phase power
Answer: P = 2.58 kW
Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ.
Phase voltage
Vph = 480/√3 = 277.1 V
Phase current
|Z| = √(7² + 24²) = 25 Ω
Iph = 277.1/25 = 11.09 A
Total real power
Only the resistive part of each impedance absorbs real power.
P = 3·Iph²·R = 3·11.09²·7 = 2.58 kW
Answer
P = 2.58 kW
Check: cos φ = R/|Z| = 0.28, and √3·VL·IL·cos φ gives the same power.
14.Three-phase power
Answer: Cph = 600.9 µF
Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ. Power factor correction: capacitors supply reactive power locally, QC = P·(tan φ1 − tan φ2). Each of the three capacitors supplies QC/3 = V²·ω·C, where V is the voltage across that capacitor: VL in a Δ bank, VL/√3 in a Y bank.
Reactive power before and after
The real power is unchanged, so each power factor fixes the reactive power: Q = P·tan φ.
Q1 = 150·tan(acos 0.78) = 150·0.8023 = 120.3 kvar
Q2 = 150·tan(acos 0.98) = 150·0.2031 = 30.46 kvar
Reactive power from the capacitors
QC = Q1 − Q2 = 89.88 kvar
Capacitance per phase
In a Y bank each capacitor is connected between a line and the star point.
Ideal transformer: the voltages are in the ratio of the turns and the currents in the inverse ratio: V₁/V₂ = N₁/N₂ = a and I₁/I₂ = N₂/N₁ = 1/a, so the power in equals the power out, V₁·I₁ = V₂·I₂. A load impedance Z on the secondary looks like a²·Z from the primary.
Rated current
Both windings carry the same apparent power.
IHV = S/V = 25000/4160 = 6.01 A
Answer
IHV = 6.01 A
16.Transformers
Answer: Ploss = 950 W
Transformer losses: the core loss (hysteresis and eddy currents) depends on the voltage and is the same at any load. The copper loss in the windings goes with the current squared, so at a fraction x of rated load it is x²·Pcu,fl. Efficiency η = Pout/(Pout + Pcore + Pcu), with Pout = x·S·pf. The efficiency is highest at the load where the copper loss equals the core loss.