The voltage source Vₛ between A and B has its + terminal at B, so it makes VB − VA = Vₛ. Use nodal analysis with a supernode to find the node voltage VA (measured from ground).
The inductor carries a steady current of 3 A. At t = 0 the switch closes the loop through R and the source is removed, so the inductor current decays through R. Find the voltage vR across R at t = 1 ms.
i(0) = 3 AR = 15 ΩL = 10 mHt = 1 ms
vR = V
8.RC & RL transientsHard
A timer starts charging an uncharged capacitor through a resistor from a 15 V supply at t = 0. It must trigger when the capacitor voltage reaches 9.48 V, exactly 1000 ms after the start. With C = 22 µF, find the resistance R needed.
Vs = 15 VVth = 9.48 VT = 1000 msC = 22 µF
R = kΩ
9.AC impedance & phasorsMedium
A series RLC circuit is connected to a 230 V (rms), 50 Hz supply. Find the rms current I.
V = 230 V (rms)f = 50 HzR = 60 ΩL = 150 mHC = 47 µF
I = A
10.AC impedance & phasorsHard
A series RLC circuit is driven by a 1 V (rms) source whose frequency is set to the resonant frequency of the circuit. Find the rms voltage VL across the inductor.
V = 1 V (rms)R = 20 ΩL = 20 mHC = 10 µF
VL = V
11.AC power & power factorMedium
A single-phase motor takes 40 kW at a power factor of 0.8 lagging from a 230 V supply. Find the reactive power Q it draws.
P = 40 kWpf = 0.8V = 230 V
Q = kvar
12.AC power & power factorHard
A single-phase load takes 40 kW at a power factor of 0.8 lagging from a 240 V, 50 Hz supply. A capacitor connected in parallel raises the power factor to 0.95. Find the reactive power QC the capacitor must supply.
P = 40 kWpf1 = 0.8pf2 = 0.95V = 240 Vf = 50 Hz
QC = kvar
13.Three-phase powerMedium
A three-phase induction motor delivers 22 kW of mechanical output power at full load. At this load its efficiency is 95% and its power factor is 0.84 lagging. The supply has a line-to-line voltage of 400 V. Find the line current IL.
Pout = 22 kWη = 95%cos φ = 0.84VL = 400 V
IL = A
14.Three-phase powerHard
A balanced three-phase load takes 150 kW at a power factor of 0.72 lagging from a 400 V (line-to-line), 50 Hz supply. A three-phase capacitor bank in parallel with the load must raise the overall power factor to 0.92 lagging. The real power stays the same. The capacitors are connected in Δ. Find the capacitance Cph of each capacitor in µF.
P = 150 kWpf1 = 0.72pf2 = 0.92VL = 400 Vf = 50 Hz
Cph = µF
15.TransformersMedium
A single-phase 250 kVA, 6600/230 V transformer operates at its rated load. Treat it as ideal. Find the current ILV in the low-voltage winding.
S = 250 kVAV1 = 6600 VV2 = 230 V
ILV = A
16.TransformersHard
A single-phase 500 kVA transformer has a core loss of 4000 W. At rated load and a power factor of 0.85 lagging its efficiency is 97.5%. Find the full-load copper loss Pcu,fl in watts.
S = 500 kVAPcore = 4000 Wpf = 0.85η = 97.5%
Pcu,fl = W
3Solutions
1.Series & parallel resistors
Answer: IR2 = 1.154 A
Series and parallel resistors: in series the same current flows through each resistor and R = R₁ + R₂ + …. In parallel each resistor has the same voltage and 1/R = 1/R₁ + 1/R₂ + …. A ladder network is reduced one pair at a time until a single equivalent resistance remains.
Combine resistors from the far end
Start at the end farthest from the source and work back towards it. Resistors carrying the same current are in series; resistors across the same two nodes are in parallel.
R3 + R4 = 6 + 4 = 10 Ω
R2 ∥ 10 = 6·10/(6+10) = 3.75 Ω
Req = R1 + 3.75 = 6 + 3.75 = 9.75 Ω
Current from the source
The source sees only Req, so Ohm’s law gives the current it delivers. That current flows through R₁.
IR1 = V1/Req = 18/9.75 = 1.846 A
Current through R₂
Subtract the drop across R₁ to get the voltage at node A, which is the voltage across R₂.
VA = V1 − IR1·R1 = 18 − 1.846·6 = 6.923 V
IR2 = VA/R2 = 6.923/6 = 1.154 A
Answer
IR2 = 1.154 A
2.Series & parallel resistors
Answer: Req = 8.448 Ω
Series and parallel resistors: in series the same current flows through each resistor and R = R₁ + R₂ + …. In parallel each resistor has the same voltage and 1/R = 1/R₁ + 1/R₂ + …. A ladder network is reduced one pair at a time until a single equivalent resistance remains.
Combine resistors from the far end
Start at the end farthest from the source and work back towards it. Resistors carrying the same current are in series; resistors across the same two nodes are in parallel.
R5 + R6 = 8 + 25 = 33 Ω
R4 ∥ 33 = 10.31 Ω
R3 + 10.31 = 40.31 Ω
R2 ∥ 40.31 = 4.448 Ω
Req = R1 + 4.448 = 4 + 4.448 = 8.448 Ω
Answer
Req = 8.448 Ω
3.Nodal analysis
Answer: VA = 12.61 V
Nodal analysis: choose a reference node, label the unknown node voltages, write Kirchhoff’s current law at each unknown node using Ohm’s law (I = ΔV/R), and solve the resulting equations.
Set up the nodes
Ground is the bottom wire. Known node voltages come straight from the sources (V1 = 24 V). Unknowns: VA, VB.
KCL at node A
Currents leaving A through the resistors equal the current pushed into A by sources.
VA/R2 + (VA − V1)/R1 + (VA − VB)/R3 = 0
VA/3 + (VA − 24)/5 + (VA − VB)/15 = 0
0.6·VA − 0.06667·VB = 4.8
KCL at node B
Currents leaving B through the resistors equal the current pushed into B by sources.
Nodal analysis: choose a reference node, label the unknown node voltages, write Kirchhoff’s current law at each unknown node using Ohm’s law (I = ΔV/R), and solve the resulting equations.
Form a supernode
The voltage source between A and B carries an unknown current, so KCL cannot be written at A or B separately. Enclose A, B and the source in one supernode: the current entering it equals the current leaving it.
VB = VA + 6
(VA − V1)/R1 + VA/R2 + VB/R3 = Is
Solve
(VA − 9)/25 + VA/5 + (VA + 6)/6 = 0.5
VA·(1/25 + 1/5 + 1/6) = 0.5 + 9/25 − 6/6 = −0.14
VA = −0.14/0.4067 = −0.3443 V
VB = 5.656 V
Answer
VA = −0.3443 V
5.Thévenin & Norton
Answer: Vth = 8.182 V
Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.
Find Rth with every source switched off
Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.
R1 ∥ R2 = 8·3/(8+3) = 2.182 Ω
Rth = (R1 ∥ R2) + R3 = 2.182 + 12 = 14.18 Ω
Find Vth, the open-circuit voltage
With a–b open, no current flows through R₃, so there is no drop across it and V_b = V_A. R₁ and R₂ form a voltage divider.
Vth = V1·R2/(R1+R2) = 30·3/(8+3) = 8.182 V
6.Thévenin & Norton
Answer: IL = 1.3 A
Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.
Find Rth with every source switched off
Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.
R1 ∥ R2 = 30·6/(30+6) = 5 Ω
Rth = (R1 ∥ R2) + R3 = 5 + 30 = 35 Ω
Find Vth, the open-circuit voltage
With a–b open, the only path for Iₛ is through R₃ into node A. Find V_A by superposition of V₁ and Iₛ, then add the drop across R₃.
VA = V1·R2/(R1+R2) + Is·(R1∥R2) = 6 + 1.5·5 = 13.5 V
Vth = VB = VA + Is·R3 = 13.5 + 1.5·30 = 58.5 V
Connect the load to the Thévenin equivalent
The Thévenin source and R_th in series behave exactly like the original circuit at a–b, so the load sees a simple series loop.
IL = Vth/(Rth + RL) = 58.5/(35 + 10) = 1.3 A
7.RC & RL transients
Answer: vR = 10.04 V
First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.
Time constant
τ = L/R = 10 mH / 15 Ω = 0.6667 ms
Decay of the current
i(t) = 3·e−1/0.6667 = 0.6694 A
vR = R·i = 15·0.6694 = 10.04 V
Answer
vR = 10.04 V
8.RC & RL transients
Answer: R = 45.47 kΩ
First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.
AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.
Reactances
ω = 2πf = 2π·50 = 314.2 rad/s
XL = ωL = 314.2·0.15 = 47.12 Ω
XC = 1/(ωC) = 1/(314.2·47·10⁻⁶) = 67.73 Ω
Impedance
In series the impedances add as complex numbers: Z = R + j(XL − XC).
The same current flows through every element of a series circuit.
I = V/|Z| = 230/63.44 = 3.626 A
Answer
I = 3.626 A
10.AC impedance & phasors
Answer: VL = 2.236 V
AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.
Resonance
At resonance the reactances cancel, so the impedance is just R.
ω₀ = 1/√(LC) = 1/√(0.02·10·10⁻⁶) = 2236 rad/s
I = V/R = 1/20 = 0.05 A
Voltage across the inductor
XL = ω₀L = 2236·0.02 = 44.72 Ω
VL = I·XL = 0.05·44.72 = 2.236 V
Answer
VL = 2.236 V
This is Q = 2.236 times the supply voltage.
11.AC power & power factor
Answer: Q = 30 kvar
AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.
Angle
φ = arccos(0.8) = 36.87°, tan φ = 0.75
Reactive power
Q = P·tan φ = 40·0.75 = 30 kvar
Answer
Q = 30 kvar
12.AC power & power factor
Answer: QC = 16.85 kvar
AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.
Reactive power before and after
The real power P does not change; only the reactive power drawn from the supply does.
Q1 = P·tan φ1 = 40·tan(36.87°) = 30 kvar
Q2 = P·tan φ2 = 40·tan(18.19°) = 13.15 kvar
QC = Q1 − Q2 = 16.85 kvar
Answer
QC = 16.85 kvar
13.Three-phase power
Answer: IL = 39.79 A
Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ.
Electrical input power
Pin = Pout/η = 22/0.95 = 23.16 kW
Line current
IL = Pin/(√3·VL·cos φ) = 23158/(√3·400·0.84) = 39.79 A
Answer
IL = 39.79 A
14.Three-phase power
Answer: Cph = 535 µF
Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ. Power factor correction: capacitors supply reactive power locally, QC = P·(tan φ1 − tan φ2). Each of the three capacitors supplies QC/3 = V²·ω·C, where V is the voltage across that capacitor: VL in a Δ bank, VL/√3 in a Y bank.
Reactive power before and after
The real power is unchanged, so each power factor fixes the reactive power: Q = P·tan φ.
Q1 = 150·tan(acos 0.72) = 150·0.9639 = 144.6 kvar
Q2 = 150·tan(acos 0.92) = 150·0.426 = 63.9 kvar
Reactive power from the capacitors
QC = Q1 − Q2 = 80.68 kvar
Capacitance per phase
In a Δ bank each capacitor is connected between two lines.
V = 400 V, ω = 2π·50 = 314.2 rad/s
Cph = (QC/3)/(ω·V²) = 26893/(314.2·400²) = 535 µF
Answer
Cph = 535 µF
15.Transformers
Answer: ILV = 1087 A
Ideal transformer: the voltages are in the ratio of the turns and the currents in the inverse ratio: V₁/V₂ = N₁/N₂ = a and I₁/I₂ = N₂/N₁ = 1/a, so the power in equals the power out, V₁·I₁ = V₂·I₂. A load impedance Z on the secondary looks like a²·Z from the primary.
Rated current
Both windings carry the same apparent power.
ILV = S/V = 250000/230 = 1087 A
Answer
ILV = 1087 A
16.Transformers
Answer: Pcu,fl = 6897 W
Transformer losses: the core loss (hysteresis and eddy currents) depends on the voltage and is the same at any load. The copper loss in the windings goes with the current squared, so at a fraction x of rated load it is x²·Pcu,fl. Efficiency η = Pout/(Pout + Pcore + Pcu), with Pout = x·S·pf. The efficiency is highest at the load where the copper loss equals the core loss.