A load RL = 20 Ω is connected across a–b. Replace the rest of the circuit with its Thévenin equivalent and find the load current IL.
V1 = 10 VR1 = 6 ΩR2 = 4 ΩR3 = 20 ΩRL = 20 Ω
IL = A
6.Thévenin & NortonHard
Find the Thévenin voltage Vth seen from terminals a–b.
V1 = 24 VIs = 0.5 AR1 = 10 ΩR2 = 5 ΩR3 = 5 Ω
Vth = V
7.RC & RL transientsMedium
The inductor carries no current before the switch closes at t = 0. How long after the switch closes does the current reach 80% of its final value? Find t.
Vs = 20 VR = 20 ΩL = 22 mH
t = ms
8.RC & RL transientsHard
Just before the switch closes at t = 0, the capacitor holds 2 V with the polarity shown. Find the capacitor voltage vC at t = 80 ms.
Vs = 5 VR = 3.3 kΩC = 47 µFvC(0) = 2 Vt = 80 ms
vC = V
9.AC impedance & phasorsMedium
A series RLC circuit is connected to a 10 V (rms), 1000 Hz supply. Find the rms current I.
V = 10 V (rms)f = 1000 HzR = 100 ΩL = 150 mHC = 22 µF
I = A
10.AC impedance & phasorsHard
A series RLC circuit is connected to a 10 V (rms), 60 Hz supply. Find the resonant frequency f0 of the circuit.
V = 10 V (rms)f = 60 HzR = 100 ΩL = 20 mHC = 2.2 µF
f0 = Hz
11.AC power & power factorMedium
A single-phase motor takes 33 kW at a power factor of 0.8 lagging from a 400 V supply. Find the line current I.
P = 33 kWpf = 0.8V = 400 V
I = A
12.AC power & power factorHard
A single-phase load takes 30 kW at a power factor of 0.7 lagging from a 230 V, 60 Hz supply. A capacitor connected in parallel raises the power factor to 0.92. Find the reactive power QC the capacitor must supply.
P = 30 kWpf1 = 0.7pf2 = 0.92V = 230 Vf = 60 Hz
QC = kvar
13.Three-phase powerMedium
A balanced three-phase load draws a line current of 80 A from a supply with a line-to-line voltage of 415 V. The power factor is 0.85 lagging. Find the total real power P drawn by the load in kW.
VL = 415 VIL = 80 Acos φ = 0.85
P = kW
14.Three-phase powerHard
A balanced three-phase load takes 300 kW at a power factor of 0.7 lagging from a 400 V (line-to-line), 50 Hz supply. A three-phase capacitor bank in parallel with the load must raise the overall power factor to 0.95 lagging. The real power stays the same. Find the total reactive power QC the capacitor bank must supply, in kvar.
P = 300 kWpf1 = 0.7pf2 = 0.95VL = 400 Vf = 50 Hz
QC = kvar
15.TransformersMedium
A single-phase 75 kVA, 7200/240 V transformer operates at its rated load. Treat it as ideal. Find the current IHV in the high-voltage winding.
S = 75 kVAV1 = 7200 VV2 = 240 V
IHV = A
16.TransformersHard
A single-phase 75 kVA transformer has a core loss of 300 W and a copper loss of 1200 W at rated load. At what load Sη,max, in kVA, is its efficiency highest?
S = 75 kVAPcore = 300 WPcu,fl = 1200 W
Sη,max = kVA
3Solutions
1.Series & parallel resistors
Answer: Req = 10.24 Ω
Series and parallel resistors: in series the same current flows through each resistor and R = R₁ + R₂ + …. In parallel each resistor has the same voltage and 1/R = 1/R₁ + 1/R₂ + …. A ladder network is reduced one pair at a time until a single equivalent resistance remains.
Combine resistors from the far end
Start at the end farthest from the source and work back towards it. Resistors carrying the same current are in series; resistors across the same two nodes are in parallel.
R3 + R4 = 6 + 8 = 14 Ω
R2 ∥ 14 = 15·14/(15+14) = 7.241 Ω
Req = R1 + 7.241 = 3 + 7.241 = 10.24 Ω
Answer
Req = 10.24 Ω
2.Series & parallel resistors
Answer: IR2 = 0.5781 A
Series and parallel resistors: in series the same current flows through each resistor and R = R₁ + R₂ + …. In parallel each resistor has the same voltage and 1/R = 1/R₁ + 1/R₂ + …. A ladder network is reduced one pair at a time until a single equivalent resistance remains.
Combine resistors from the far end
Start at the end farthest from the source and work back towards it. Resistors carrying the same current are in series; resistors across the same two nodes are in parallel.
R5 + R6 = 15 + 25 = 40 Ω
R4 ∥ 40 = 17.14 Ω
R3 + 17.14 = 20.14 Ω
R2 ∥ 20.14 = 7.52 Ω
Req = R1 + 7.52 = 25 + 7.52 = 32.52 Ω
Current from the source
The source sees only Req, so Ohm’s law gives the current it delivers. That current flows through R₁.
IR1 = V1/Req = 30/32.52 = 0.9225 A
Current through R₂
Subtract the drop across R₁ to get the voltage at node A, which is the voltage across R₂.
VA = V1 − IR1·R1 = 30 − 0.9225·25 = 6.937 V
IR2 = VA/R2 = 6.937/12 = 0.5781 A
Answer
IR2 = 0.5781 A
3.Nodal analysis
Answer: IR3 = 0.1333 A
Nodal analysis: choose a reference node, label the unknown node voltages, write Kirchhoff’s current law at each unknown node using Ohm’s law (I = ΔV/R), and solve the resulting equations.
Set up the nodes
Ground is the bottom wire. Known node voltages come straight from the sources (V1 = 9 V). Unknowns: VA, VB.
KCL at node A
Currents leaving A through the resistors equal the current pushed into A by sources.
VA/R2 + (VA − V1)/R1 + (VA − VB)/R3 = 0
VA/20 + (VA − 9)/5 + (VA − VB)/2 = 0
0.75·VA − 0.5·VB = 1.8
KCL at node B
Currents leaving B through the resistors equal the current pushed into B by sources.
VB/R4 + (VB − VA)/R3 = Is
VB/3 + (VB − VA)/2 = 2
−0.5·VA + 0.8333·VB = 2
Solve
Δ = (0.75)(0.8333) − (−0.5)(−0.5) = 0.375
VA = Δ1/Δ = 2.5/0.375 = 6.667 V
VB = Δ2/Δ = 2.4/0.375 = 6.4 V
Answer
IR3 = (VA − VB)/R3 = (6.667 − 6.4)/2 = 0.1333 A
4.Nodal analysis
Answer: IR2 = 0.3273 A
Nodal analysis: choose a reference node, label the unknown node voltages, write Kirchhoff’s current law at each unknown node using Ohm’s law (I = ΔV/R), and solve the resulting equations.
Set up the nodes
Ground is the bottom wire. Known node voltages come straight from the sources (V1 = 12 V, V2 = −30 V). Unknowns: VA, VB.
KCL at node A
Currents leaving A through the resistors equal the current pushed into A by sources.
VA/R3 + (VA − V1)/R1 + (VA − VB)/R2 = 0
VA/4 + (VA − 12)/15 + (VA − VB)/25 = 0
0.3567·VA − 0.04·VB = 0.8
KCL at node B
Currents leaving B through the resistors equal the current pushed into B by sources.
Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.
Find Rth with every source switched off
Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.
R1 ∥ R2 = 6·4/(6+4) = 2.4 Ω
Rth = (R1 ∥ R2) + R3 = 2.4 + 20 = 22.4 Ω
Find Vth, the open-circuit voltage
With a–b open, no current flows through R₃, so there is no drop across it and V_b = V_A. R₁ and R₂ form a voltage divider.
Vth = V1·R2/(R1+R2) = 10·4/(6+4) = 4 V
Connect the load to the Thévenin equivalent
The Thévenin source and R_th in series behave exactly like the original circuit at a–b, so the load sees a simple series loop.
IL = Vth/(Rth + RL) = 4/(22.4 + 20) = 0.09434 A
6.Thévenin & Norton
Answer: Vth = 3.833 V
Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.
Find Rth with every source switched off
Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.
R1 ∥ R2 = 10·5/(10+5) = 3.333 Ω
Rth = (R1 ∥ R2) + R3 = 3.333 + 5 = 8.333 Ω
Find Vth, the open-circuit voltage
With a–b open, the only path for Iₛ is through R₃ into node A. Find V_A by superposition of V₁ and Iₛ, then add the drop across R₃.
VA = V1·R2/(R1+R2) + Is·(R1∥R2) = 8 + (−0.5)·3.333 = 6.333 V
Vth = VB = VA + Is·R3 = 6.333 + (−0.5)·5 = 3.833 V
7.RC & RL transients
Answer: t = 1.77 ms
First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.
Time constant and final current
Long after the switch closes the inductor behaves like a short circuit, so the final current is set by R alone.
τ = L/R = 22 mH / 20 Ω = 1.1 ms
i(∞) = Vs/R = 20/20 = 1 A
Solve for the time
0.8 = 1 − e−t/τ → t = −τ·ln(1 − 0.8)
t = −1.1·ln(0.2) = 1.77 ms
Answer
t = 1.77 ms
8.RC & RL transients
Answer: vC = 3.209 V
First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.
Initial value, final value, time constant
The capacitor voltage cannot jump, so it starts at its stored value and heads for the source voltage.
vC(0) = 2 V, vC(∞) = Vs = 5 V
τ = R·C = 3.3 kΩ · 47 µF = 155.1 ms
vC(t) = 5 + (2 − 5)·e−t/τ
Voltage at the given time
vC(80) = 5 + (−3)·e−80/155.1 = 3.209 V
Answer
vC = 3.209 V
9.AC impedance & phasors
Answer: I = 0.01063 A
AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.
Reactances
ω = 2πf = 2π·1000 = 6283 rad/s
XL = ωL = 6283·0.15 = 942.5 Ω
XC = 1/(ωC) = 1/(6283·22·10⁻⁶) = 7.234 Ω
Impedance
In series the impedances add as complex numbers: Z = R + j(XL − XC).
The same current flows through every element of a series circuit.
I = V/|Z| = 10/940.6 = 0.01063 A
Answer
I = 0.01063 A
10.AC impedance & phasors
Answer: f0 = 758.7 Hz
AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.
Resonance
At resonance the inductive and capacitive reactances cancel: ωL = 1/(ωC). The supply frequency does not matter.
AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.
Line current
Only the real part of the power does work, so divide by the power factor.
I = P/(V·cos φ) = 33000/(400·0.8) = 103.1 A
Answer
I = 103.1 A
12.AC power & power factor
Answer: QC = 17.83 kvar
AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.
Reactive power before and after
The real power P does not change; only the reactive power drawn from the supply does.
Q1 = P·tan φ1 = 30·tan(45.57°) = 30.61 kvar
Q2 = P·tan φ2 = 30·tan(23.07°) = 12.78 kvar
QC = Q1 − Q2 = 17.83 kvar
Answer
QC = 17.83 kvar
13.Three-phase power
Answer: P = 48.88 kW
Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ.
Apparent power
S = √3·VL·IL = √3·415·80 = 57.5 kVA
Real power
P = S·cos φ = 57.5·0.85 = 48.88 kW
Answer
P = 48.88 kW
14.Three-phase power
Answer: QC = 207.5 kvar
Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ. Power factor correction: capacitors supply reactive power locally, QC = P·(tan φ1 − tan φ2). Each of the three capacitors supplies QC/3 = V²·ω·C, where V is the voltage across that capacitor: VL in a Δ bank, VL/√3 in a Y bank.
Reactive power before and after
The real power is unchanged, so each power factor fixes the reactive power: Q = P·tan φ.
Q1 = 300·tan(acos 0.7) = 300·1.02 = 306.1 kvar
Q2 = 300·tan(acos 0.95) = 300·0.3287 = 98.61 kvar
Reactive power from the capacitors
QC = Q1 − Q2 = 207.5 kvar
Answer
QC = 207.5 kvar
15.Transformers
Answer: IHV = 10.42 A
Ideal transformer: the voltages are in the ratio of the turns and the currents in the inverse ratio: V₁/V₂ = N₁/N₂ = a and I₁/I₂ = N₂/N₁ = 1/a, so the power in equals the power out, V₁·I₁ = V₂·I₂. A load impedance Z on the secondary looks like a²·Z from the primary.
Rated current
Both windings carry the same apparent power.
IHV = S/V = 75000/7200 = 10.42 A
Answer
IHV = 10.42 A
16.Transformers
Answer: Sη,max = 37.5 kVA
Transformer losses: the core loss (hysteresis and eddy currents) depends on the voltage and is the same at any load. The copper loss in the windings goes with the current squared, so at a fraction x of rated load it is x²·Pcu,fl. Efficiency η = Pout/(Pout + Pcore + Pcu), with Pout = x·S·pf. The efficiency is highest at the load where the copper loss equals the core loss.