Find the Thévenin resistance Rth seen from terminals a–b.
V1 = 30 VR1 = 6 ΩR2 = 8 ΩR3 = 10 Ω
Rth = Ω
6.Thévenin & NortonHard
Find the Thévenin voltage Vth seen from terminals a–b.
V1 = 5 VIs = 0.5 AR1 = 30 ΩR2 = 25 ΩR3 = 12 Ω
Vth = V
7.RC & RL transientsMedium
The source Vₛ charges the capacitor through R₁, and R₂ is connected in parallel with C. The capacitor is uncharged when the switch closes at t = 0. Find the capacitor voltage vC at t = 200 ms.
Vs = 6 VR1 = 6.8 kΩR2 = 10 kΩC = 47 µFt = 200 ms
vC = V
8.RC & RL transientsHard
The switch across R2 has been closed for a long time, so the inductor current is steady. At t = 0 the switch opens. Find the inductor current i at t = 1 ms.
Vs = 12 VR1 = 15 ΩR2 = 22 ΩL = 22 mHt = 1 ms
i = A
9.AC impedance & phasorsMedium
A series RLC circuit is connected to a 50 V (rms), 50 Hz supply. Find the rms current I.
V = 50 V (rms)f = 50 HzR = 80 ΩL = 250 mHC = 100 µF
I = A
10.AC impedance & phasorsHard
A series RLC circuit is driven by a 2 V (rms) source whose frequency is set to the resonant frequency of the circuit. Find the rms voltage VL across the inductor.
V = 2 V (rms)R = 15 ΩL = 5 mHC = 0.22 µF
VL = V
11.AC power & power factorMedium
Two loads are connected in parallel to a 240 V single-phase supply: a 15 kW load at a power factor of 0.8 lagging and a 23 kW load at a power factor of 0.85 lagging. Find the total current I drawn from the supply.
A 24 V (rms), 50 Hz source has an internal impedance Zs = 50 + j15 Ω. The load impedance ZL can be chosen freely. Find the maximum real power Pmax that can be delivered to the load.
Vs = 24 V (rms)f = 50 HzZs = 50 + j15 Ω
Pmax = W
13.Three-phase powerMedium
A three-phase induction motor delivers 55 kW of mechanical output power at full load. At this load its efficiency is 95% and its power factor is 0.88 lagging. The supply has a line-to-line voltage of 400 V. Find the line current IL.
Pout = 55 kWη = 95%cos φ = 0.88VL = 400 V
IL = A
14.Three-phase powerHard
A balanced three-phase load takes 250 kW at a power factor of 0.7 lagging from a 480 V (line-to-line), 60 Hz supply. A three-phase capacitor bank in parallel with the load must raise the overall power factor to 0.95 lagging. The real power stays the same. The capacitors are connected in Δ. Find the capacitance Cph of each capacitor in µF.
P = 250 kWpf1 = 0.7pf2 = 0.95VL = 480 Vf = 60 Hz
Cph = µF
15.TransformersMedium
An amplifier with an output resistance of 72 Ω drives an 8 Ω loudspeaker through an ideal transformer. For maximum power transfer the loudspeaker must look like 72 Ω from the amplifier. Find the turns ratio a = N₁/N₂.
Rs = 72 ΩRL = 8 Ω
a =
16.TransformersHard
A single-phase 250 kVA transformer has a core loss of 1000 W and a copper loss of 4000 W at rated load. At what load Sη,max, in kVA, is its efficiency highest?
S = 250 kVAPcore = 1000 WPcu,fl = 4000 W
Sη,max = kVA
3Solutions
1.Series & parallel resistors
Answer: Req = 9.444 Ω
Series and parallel resistors: in series the same current flows through each resistor and R = R₁ + R₂ + …. In parallel each resistor has the same voltage and 1/R = 1/R₁ + 1/R₂ + …. A ladder network is reduced one pair at a time until a single equivalent resistance remains.
Combine resistors from the far end
Start at the end farthest from the source and work back towards it. Resistors carrying the same current are in series; resistors across the same two nodes are in parallel.
R3 + R4 = 3 + 5 = 8 Ω
R2 ∥ 8 = 10·8/(10+8) = 4.444 Ω
Req = R1 + 4.444 = 5 + 4.444 = 9.444 Ω
Answer
Req = 9.444 Ω
2.Series & parallel resistors
Answer: IR2 = 0.1014 A
Series and parallel resistors: in series the same current flows through each resistor and R = R₁ + R₂ + …. In parallel each resistor has the same voltage and 1/R = 1/R₁ + 1/R₂ + …. A ladder network is reduced one pair at a time until a single equivalent resistance remains.
Combine resistors from the far end
Start at the end farthest from the source and work back towards it. Resistors carrying the same current are in series; resistors across the same two nodes are in parallel.
R5 + R6 = 12 + 30 = 42 Ω
R4 ∥ 42 = 4.468 Ω
R3 + 4.468 = 10.47 Ω
R2 ∥ 10.47 = 3.384 Ω
Req = R1 + 3.384 = 30 + 3.384 = 33.38 Ω
Current from the source
The source sees only Req, so Ohm’s law gives the current it delivers. That current flows through R₁.
IR1 = V1/Req = 5/33.38 = 0.1498 A
Current through R₂
Subtract the drop across R₁ to get the voltage at node A, which is the voltage across R₂.
VA = V1 − IR1·R1 = 5 − 0.1498·30 = 0.5068 V
IR2 = VA/R2 = 0.5068/5 = 0.1014 A
Answer
IR2 = 0.1014 A
3.Nodal analysis
Answer: IR1 = −2.016 A
Nodal analysis: choose a reference node, label the unknown node voltages, write Kirchhoff’s current law at each unknown node using Ohm’s law (I = ΔV/R), and solve the resulting equations.
Set up the nodes
Ground is the bottom wire. Known node voltages come straight from the sources (V1 = 6 V). Unknowns: VA, VB.
KCL at node A
Currents leaving A through the resistors equal the current pushed into A by sources.
VA/R2 + (VA − V1)/R1 + (VA − VB)/R3 = 0
VA/12 + (VA − 6)/5 + (VA − VB)/5 = 0
0.4833·VA − 0.2·VB = 1.2
KCL at node B
Currents leaving B through the resistors equal the current pushed into B by sources.
VB/R4 + (VB − VA)/R3 = Is
VB/20 + (VB − VA)/5 = 5
−0.2·VA + 0.25·VB = 5
Solve
Δ = (0.4833)(0.25) − (−0.2)(−0.2) = 0.08083
VA = Δ1/Δ = 1.3/0.08083 = 16.08 V
VB = Δ2/Δ = 2.657/0.08083 = 32.87 V
Answer
IR1 = (V1 − VA)/R1 = (6 − 16.08)/5 = −2.016 A
4.Nodal analysis
Answer: VB = 9 V
Nodal analysis: choose a reference node, label the unknown node voltages, write Kirchhoff’s current law at each unknown node using Ohm’s law (I = ΔV/R), and solve the resulting equations.
Set up the nodes
Ground is the bottom wire. Known node voltages come straight from the sources (V1 = 18 V, V2 = 9 V). Unknowns: VA, VB.
KCL at node A
Currents leaving A through the resistors equal the current pushed into A by sources.
VA/R3 + (VA − V1)/R1 + (VA − VB)/R2 = 0
VA/10 + (VA − 18)/30 + (VA − VB)/15 = 0
0.2·VA − 0.06667·VB = 0.6
KCL at node B
Currents leaving B through the resistors equal the current pushed into B by sources.
VB/R5 + (VB − VA)/R2 + (VB − V2)/R4 = Is
VB/30 + (VB − VA)/15 + (VB − 9)/20 = 0.5
−0.06667·VA + 0.15·VB = 0.95
Solve
Δ = (0.2)(0.15) − (−0.06667)(−0.06667) = 0.02556
VA = Δ1/Δ = 0.1533/0.02556 = 6 V
VB = Δ2/Δ = 0.23/0.02556 = 9 V
Answer
VB = 9 V
5.Thévenin & Norton
Answer: Rth = 13.43 Ω
Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.
Find Rth with every source switched off
Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.
R1 ∥ R2 = 6·8/(6+8) = 3.429 Ω
Rth = (R1 ∥ R2) + R3 = 3.429 + 10 = 13.43 Ω
6.Thévenin & Norton
Answer: Vth = −10.55 V
Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.
Find Rth with every source switched off
Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.
R1 ∥ R2 = 30·25/(30+25) = 13.64 Ω
Rth = (R1 ∥ R2) + R3 = 13.64 + 12 = 25.64 Ω
Find Vth, the open-circuit voltage
With a–b open, the only path for Iₛ is through R₃ into node A. Find V_A by superposition of V₁ and Iₛ, then add the drop across R₃.
VA = V1·R2/(R1+R2) + Is·(R1∥R2) = 2.273 + (−0.5)·13.64 = −4.545 V
Vth = VB = VA + Is·R3 = −4.545 + (−0.5)·12 = −10.55 V
7.RC & RL transients
Answer: vC = 2.323 V
First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.
Thévenin equivalent seen by the capacitor
Short the source to find Rth; open the capacitor to find the voltage it will settle at.
Rth = R1 ∥ R2 = 6.8·10/(6.8 + 10) = 4.048 kΩ
vC(∞) = 6·10/(6.8 + 10) = 3.571 V
Time constant
τ = Rth·C = 4.048·47 = 190.2 ms
Charging curve
vC(t) = 3.571·(1 − e−200/190.2) = 2.323 V
Answer
vC = 2.323 V
8.RC & RL transients
Answer: i = 0.4128 A
First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.
Initial value, final value, time constant
Before t = 0 the closed switch bypasses R₂; afterwards R₁ and R₂ are both in the loop.
i(0) = 12/15 = 0.8 A
i(∞) = 12/(15 + 22) = 0.3243 A
τ = L/R = 22/37 = 0.5946 ms
i(t) = 0.3243 + (0.8 − 0.3243)·e−t/τ
Current at the given time
i(1) = 0.3243 + (0.4757)·e−1/0.5946 = 0.4128 A
Answer
i = 0.4128 A
9.AC impedance & phasors
Answer: I = 0.5397 A
AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.
Reactances
ω = 2πf = 2π·50 = 314.2 rad/s
XL = ωL = 314.2·0.25 = 78.54 Ω
XC = 1/(ωC) = 1/(314.2·100·10⁻⁶) = 31.83 Ω
Impedance
In series the impedances add as complex numbers: Z = R + j(XL − XC).
The same current flows through every element of a series circuit.
I = V/|Z| = 50/92.64 = 0.5397 A
Answer
I = 0.5397 A
10.AC impedance & phasors
Answer: VL = 20.1 V
AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.
Resonance
At resonance the reactances cancel, so the impedance is just R.
ω₀ = 1/√(LC) = 1/√(0.005·0.22·10⁻⁶) = 30151 rad/s
I = V/R = 2/15 = 0.1333 A
Voltage across the inductor
XL = ω₀L = 30151·0.005 = 150.8 Ω
VL = I·XL = 0.1333·150.8 = 20.1 V
Answer
VL = 20.1 V
This is Q = 10.05 times the supply voltage.
11.AC power & power factor
Answer: I = 190.7 A
AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.
Reactive power of each load
A lagging load takes reactive power (Q > 0); a leading load supplies it (Q < 0).
Q1 = 15·tan(arccos 0.8) = 11.25 kvar
Q2 = 23·tan(arccos 0.85) = 14.25 kvar
Totals
P = 15 + 23 = 38 kW
Q = 11.25 + 14.25 = 25.5 kvar
S = √(38² + 25.5²) = 45.77 kVA
Total current
I = S/V = 45765/240 = 190.7 A
Answer
I = 190.7 A
12.AC power & power factor
Answer: Pmax = 2.88 W
AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.
Conjugate match
The load reactance cancels the source reactance, and the load resistance equals the source resistance.
ZL = Zs* = 50 − j15 Ω
Maximum power
I = Vs/(2Rs) = 24/100 = 0.24 A
Pmax = I²·RL = Vs²/(4Rs) = 24²/(4·50) = 2.88 W
Answer
Pmax = 2.88 W
13.Three-phase power
Answer: IL = 94.96 A
Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ.
Electrical input power
Pin = Pout/η = 55/0.95 = 57.89 kW
Line current
IL = Pin/(√3·VL·cos φ) = 57895/(√3·400·0.88) = 94.96 A
Answer
IL = 94.96 A
14.Three-phase power
Answer: Cph = 663.5 µF
Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ. Power factor correction: capacitors supply reactive power locally, QC = P·(tan φ1 − tan φ2). Each of the three capacitors supplies QC/3 = V²·ω·C, where V is the voltage across that capacitor: VL in a Δ bank, VL/√3 in a Y bank.
Reactive power before and after
The real power is unchanged, so each power factor fixes the reactive power: Q = P·tan φ.
Q1 = 250·tan(acos 0.7) = 250·1.02 = 255.1 kvar
Q2 = 250·tan(acos 0.95) = 250·0.3287 = 82.17 kvar
Reactive power from the capacitors
QC = Q1 − Q2 = 172.9 kvar
Capacitance per phase
In a Δ bank each capacitor is connected between two lines.
V = 480 V, ω = 2π·60 = 377 rad/s
Cph = (QC/3)/(ω·V²) = 57627/(377·480²) = 663.5 µF
Answer
Cph = 663.5 µF
15.Transformers
Answer: a = 3
Ideal transformer: the voltages are in the ratio of the turns and the currents in the inverse ratio: V₁/V₂ = N₁/N₂ = a and I₁/I₂ = N₂/N₁ = 1/a, so the power in equals the power out, V₁·I₁ = V₂·I₂. A load impedance Z on the secondary looks like a²·Z from the primary.
Match the referred load
a²·8 = 72
a = √(72/8) = √9 = 3
Answer
a = 3
16.Transformers
Answer: Sη,max = 125 kVA
Transformer losses: the core loss (hysteresis and eddy currents) depends on the voltage and is the same at any load. The copper loss in the windings goes with the current squared, so at a fraction x of rated load it is x²·Pcu,fl. Efficiency η = Pout/(Pout + Pcore + Pcu), with Pout = x·S·pf. The efficiency is highest at the load where the copper loss equals the core loss.