The diamond is a voltage-controlled current source that pushes a current of 0.25·VA (in A, with VA in V) up into node B. Use nodal analysis to find the node voltage VB (measured from ground).
Find the Thévenin resistance Rth seen from terminals a–b.
V1 = 18 VR1 = 8 ΩR2 = 8 ΩR3 = 6 Ω
Rth = Ω
6.Thévenin & NortonHard
Find the Norton current IN: the current that flows from a to b if the terminals are shorted.
V1 = 6 VIs = 5 AR1 = 25 ΩR2 = 12 ΩR3 = 5 Ω
IN = A
7.RC & RL transientsMedium
The inductor carries no current before the switch closes at t = 0. Find the current i at t = 1 ms.
Vs = 24 VR = 100 ΩL = 22 mHt = 1 ms
i = A
8.RC & RL transientsHard
Just before the switch closes at t = 0, the capacitor holds 24 V with the polarity shown. How long does it take for vC to reach 10.7 V? Find t.
Vs = 5 VR = 6.8 kΩC = 22 µFvC(0) = 24 V
t = ms
9.AC impedance & phasorsMedium
A series RLC circuit is connected to a 120 V (rms), 50 Hz supply. Find the rms current I.
V = 120 V (rms)f = 50 HzR = 15 ΩL = 250 mHC = 47 µF
I = A
10.AC impedance & phasorsHard
A series RLC circuit is connected to a 120 V (rms), 200 Hz supply. Find the rms voltage VC across the capacitor.
V = 120 V (rms)f = 200 HzR = 60 ΩL = 250 mHC = 100 µF
VC = V
11.AC power & power factorMedium
An inductive load takes 6 A and 612 W from a 120 V (rms) single-phase supply. Model it as a resistance R in series with a reactance X. Find R.
V = 120 VI = 6 AP = 612 W
R = Ω
12.AC power & power factorHard
A single-phase load takes 9 kW at a power factor of 0.6 lagging from a 240 V, 60 Hz supply. A 330 µF capacitor is connected in parallel with the load. Find the new line current I.
P = 9 kWpf1 = 0.6V = 240 Vf = 60 HzC = 330 µF
I = A
13.Three-phase powerMedium
A balanced Δ-connected load with an impedance of 18 + j24 Ω per phase is connected to a balanced three-phase supply with a line-to-line voltage of 415 V. Find the total real power P absorbed by the load in kW.
VL = 415 VZ = 18 + j24 Ω per phase
P = kW
14.Three-phase powerHard
A balanced three-phase load takes 50 kW at a power factor of 0.65 lagging from a 400 V (line-to-line), 60 Hz supply. A three-phase capacitor bank in parallel with the load must raise the overall power factor to 0.9 lagging. The real power stays the same. Find the total reactive power QC the capacitor bank must supply, in kvar.
P = 50 kWpf1 = 0.65pf2 = 0.9VL = 400 Vf = 60 Hz
QC = kvar
15.TransformersMedium
A single-phase 15 kVA, 6600/230 V transformer operates at its rated load. Treat it as ideal. Find the current ILV in the low-voltage winding.
S = 15 kVAV1 = 6600 VV2 = 230 V
ILV = A
16.TransformersHard
A single-phase 25 kVA transformer has a core loss of 200 W. At rated load and a power factor of 0.9 lagging its efficiency is 98.2%. Find the full-load copper loss Pcu,fl in watts.
S = 25 kVAPcore = 200 Wpf = 0.9η = 98.2%
Pcu,fl = W
3Solutions
1.Series & parallel resistors
Answer: IR1 = 4.468 A
Series and parallel resistors: in series the same current flows through each resistor and R = R₁ + R₂ + …. In parallel each resistor has the same voltage and 1/R = 1/R₁ + 1/R₂ + …. A ladder network is reduced one pair at a time until a single equivalent resistance remains.
Combine resistors from the far end
Start at the end farthest from the source and work back towards it. Resistors carrying the same current are in series; resistors across the same two nodes are in parallel.
R3 + R4 = 12 + 10 = 22 Ω
R2 ∥ 22 = 6·22/(6+22) = 4.714 Ω
Req = R1 + 4.714 = 2 + 4.714 = 6.714 Ω
Current from the source
The source sees only Req, so Ohm’s law gives the current it delivers. That current flows through R₁.
IR1 = V1/Req = 30/6.714 = 4.468 A
Answer
IR1 = 4.468 A
2.Series & parallel resistors
Answer: IR1 = 1.845 A
Series and parallel resistors: in series the same current flows through each resistor and R = R₁ + R₂ + …. In parallel each resistor has the same voltage and 1/R = 1/R₁ + 1/R₂ + …. A ladder network is reduced one pair at a time until a single equivalent resistance remains.
Combine resistors from the far end
Start at the end farthest from the source and work back towards it. Resistors carrying the same current are in series; resistors across the same two nodes are in parallel.
R5 + R6 = 5 + 25 = 30 Ω
R4 ∥ 30 = 3.529 Ω
R3 + 3.529 = 7.529 Ω
R2 ∥ 7.529 = 3.005 Ω
Req = R1 + 3.005 = 10 + 3.005 = 13 Ω
Current from the source
The source sees only Req, so Ohm’s law gives the current it delivers. That current flows through R₁.
IR1 = V1/Req = 24/13 = 1.845 A
Answer
IR1 = 1.845 A
3.Nodal analysis
Answer: VB = 15.69 V
Nodal analysis: choose a reference node, label the unknown node voltages, write Kirchhoff’s current law at each unknown node using Ohm’s law (I = ΔV/R), and solve the resulting equations.
Set up the nodes
Ground is the bottom wire. Known node voltages come straight from the sources (V1 = 15 V). Unknowns: VA, VB.
KCL at node A
Currents leaving A through the resistors equal the current pushed into A by sources.
VA/R2 + (VA − V1)/R1 + (VA − VB)/R3 = 0
VA/8 + (VA − 15)/3 + (VA − VB)/20 = 0
0.5083·VA − 0.05·VB = 5
KCL at node B
Currents leaving B through the resistors equal the current pushed into B by sources.
VB/R4 + (VB − VA)/R3 = Is
VB/20 + (VB − VA)/20 = 1
−0.05·VA + 0.1·VB = 1
Solve
Δ = (0.5083)(0.1) − (−0.05)(−0.05) = 0.04833
VA = Δ1/Δ = 0.55/0.04833 = 11.38 V
VB = Δ2/Δ = 0.7583/0.04833 = 15.69 V
Answer
VB = 15.69 V
4.Nodal analysis
Answer: VB = 12.2 V
Nodal analysis: choose a reference node, label the unknown node voltages, write Kirchhoff’s current law at each unknown node using Ohm’s law (I = ΔV/R), and solve the resulting equations.
KCL at node A
Currents leaving A through the resistors equal the current pushed into A by sources.
(VA − V1)/R1 + VA/R2 + (VA − VB)/R3 = 0
0.4583·VA − 0.08333·VB = 1.5
KCL at node B
The dependent source pushes g·VA into node B. Treat it like an independent source, then move the VA term to the left-hand side.
Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.
Find Rth with every source switched off
Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.
R1 ∥ R2 = 8·8/(8+8) = 4 Ω
Rth = (R1 ∥ R2) + R3 = 4 + 6 = 10 Ω
6.Thévenin & Norton
Answer: IN = −4.852 A
Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.
Find Rth with every source switched off
Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.
R1 ∥ R2 = 25·12/(25+12) = 8.108 Ω
Rth = (R1 ∥ R2) + R3 = 8.108 + 5 = 13.11 Ω
Find Vth, the open-circuit voltage
With a–b open, the only path for Iₛ is through R₃ into node A. Find V_A by superposition of V₁ and Iₛ, then add the drop across R₃.
VA = V1·R2/(R1+R2) + Is·(R1∥R2) = 1.946 + (−5)·8.108 = −38.59 V
Vth = VB = VA + Is·R3 = −38.59 + (−5)·5 = −63.59 V
Norton equivalent
A Norton source is the same circuit seen as a current source in parallel with R_th. Its current is the short-circuit current at a–b.
IN = Vth/Rth = −63.59/13.11 = −4.852 A
7.RC & RL transients
Answer: i = 0.2375 A
First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.
Time constant and final current
Long after the switch closes the inductor behaves like a short circuit, so the final current is set by R alone.
First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.
Initial value, final value, time constant
The capacitor voltage cannot jump, so it starts at its stored value and heads for the source voltage.
t = τ·ln((24 − 5)/(10.7 − 5)) = 149.6·ln(3.333) = 180.1 ms
Answer
t = 180.1 ms
9.AC impedance & phasors
Answer: I = 6.489 A
AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.
Reactances
ω = 2πf = 2π·50 = 314.2 rad/s
XL = ωL = 314.2·0.25 = 78.54 Ω
XC = 1/(ωC) = 1/(314.2·47·10⁻⁶) = 67.73 Ω
Impedance
In series the impedances add as complex numbers: Z = R + j(XL − XC).
The same current flows through every element of a series circuit.
I = V/|Z| = 120/18.49 = 6.489 A
Answer
I = 6.489 A
10.AC impedance & phasors
Answer: VC = 3.06 V
AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.
Reactances
ω = 2πf = 2π·200 = 1257 rad/s
XL = ωL = 1257·0.25 = 314.2 Ω
XC = 1/(ωC) = 1/(1257·100·10⁻⁶) = 7.958 Ω
Impedance
In series the impedances add as complex numbers: Z = R + j(XL − XC).
The same current flows through every element of a series circuit.
I = V/|Z| = 120/312 = 0.3846 A
Voltage across the capacitor
VC = I·XC = 0.3846·7.958 = 3.06 V
Answer
VC = 3.06 V
11.AC power & power factor
Answer: R = 17 Ω
AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.
Resistance from the real power
R = P/I² = 612/6² = 17 Ω
Answer
R = 17 Ω
12.AC power & power factor
Answer: I = 42.57 A
AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.
Reactive power before and after
The real power P does not change; only the reactive power drawn from the supply does.
Q1 = 9·tan(arccos 0.6) = 12 kvar
QC = V²·2πf·C = 240²·2π·60·330·10⁻⁶ = 7166 var = 7.166 kvar
Q2 = 12 − 7.166 = 4.834 kvar
New apparent power
S2 = √(9² + 4.834²) = 10.22 kVA
New line current
I = S2/V = 10216/240 = 42.57 A
Answer
I = 42.57 A
13.Three-phase power
Answer: P = 10.33 kW
Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ.
Phase voltage
Vph = VL = 415 V
Phase current
|Z| = √(18² + 24²) = 30 Ω
Iph = 415/30 = 13.83 A
Total real power
Only the resistive part of each impedance absorbs real power.
P = 3·Iph²·R = 3·13.83²·18 = 10.33 kW
Answer
P = 10.33 kW
Check: cos φ = R/|Z| = 0.6, and √3·VL·IL·cos φ gives the same power.
14.Three-phase power
Answer: QC = 34.24 kvar
Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ. Power factor correction: capacitors supply reactive power locally, QC = P·(tan φ1 − tan φ2). Each of the three capacitors supplies QC/3 = V²·ω·C, where V is the voltage across that capacitor: VL in a Δ bank, VL/√3 in a Y bank.
Reactive power before and after
The real power is unchanged, so each power factor fixes the reactive power: Q = P·tan φ.
Q1 = 50·tan(acos 0.65) = 50·1.169 = 58.46 kvar
Q2 = 50·tan(acos 0.9) = 50·0.4843 = 24.22 kvar
Reactive power from the capacitors
QC = Q1 − Q2 = 34.24 kvar
Answer
QC = 34.24 kvar
15.Transformers
Answer: ILV = 65.22 A
Ideal transformer: the voltages are in the ratio of the turns and the currents in the inverse ratio: V₁/V₂ = N₁/N₂ = a and I₁/I₂ = N₂/N₁ = 1/a, so the power in equals the power out, V₁·I₁ = V₂·I₂. A load impedance Z on the secondary looks like a²·Z from the primary.
Rated current
Both windings carry the same apparent power.
ILV = S/V = 15000/230 = 65.22 A
Answer
ILV = 65.22 A
16.Transformers
Answer: Pcu,fl = 212.4 W
Transformer losses: the core loss (hysteresis and eddy currents) depends on the voltage and is the same at any load. The copper loss in the windings goes with the current squared, so at a fraction x of rated load it is x²·Pcu,fl. Efficiency η = Pout/(Pout + Pcore + Pcu), with Pout = x·S·pf. The efficiency is highest at the load where the copper loss equals the core loss.