The diamond is a voltage-controlled current source that pushes a current of 0.2·VA (in A, with VA in V) up into node B. Use nodal analysis to find the current IR4 through R4 in the direction of the arrow.
Find the Thévenin resistance Rth seen from terminals a–b.
V1 = 10 VR1 = 10 ΩR2 = 15 ΩR3 = 5 Ω
Rth = Ω
6.Thévenin & NortonHard
Find the Norton current IN: the current that flows from a to b if the terminals are shorted.
V1 = 15 VIs = 3 AR1 = 6 ΩR2 = 12 ΩR3 = 20 Ω
IN = A
7.RC & RL transientsMedium
The inductor carries a steady current of 0.5 A. At t = 0 the switch closes the loop through R and the source is removed, so the inductor current decays through R. How long does it take for the current to fall to 0.125 A? Find t.
i(0) = 0.5 AR = 100 ΩL = 100 mH
t = ms
8.RC & RL transientsHard
The switch has been closed for a long time, so the circuit is in steady state. At t = 0 the switch opens. Find the current i2 through R2 at t = 200 ms.
Vs = 6 VR1 = 2.2 kΩR2 = 3.3 kΩC = 22 µFt = 200 ms
i2 = mA
9.AC impedance & phasorsMedium
A series RLC circuit with C = 0.22 µF must resonate at 500 Hz. Find the inductance L needed.
f0 = 500 HzC = 0.22 µF
L = mH
10.AC impedance & phasorsHard
A series RLC circuit is driven by a 1 V (rms) source whose frequency is set to the resonant frequency of the circuit. Find the rms voltage VL across the inductor.
V = 1 V (rms)R = 10 ΩL = 5 mHC = 1 µF
VL = V
11.AC power & power factorMedium
A single-phase motor takes 23 kW at a power factor of 0.75 lagging from a 240 V supply. Find the line current I.
P = 23 kWpf = 0.75V = 240 V
I = A
12.AC power & power factorHard
A 50 V (rms), 60 Hz source has an internal impedance Zs = 4 + j5 Ω. The load impedance ZL can be chosen freely. The load for maximum power is built from a resistor in series with a capacitor. Find the capacitance C.
Vs = 50 V (rms)f = 60 HzZs = 4 + j5 Ω
C = µF
13.Three-phase powerMedium
A balanced three-phase load draws a line current of 20 A from a supply with a line-to-line voltage of 400 V. The power factor is 0.7 lagging. Find the total real power P drawn by the load in kW.
VL = 400 VIL = 20 Acos φ = 0.7
P = kW
14.Three-phase powerHard
A balanced three-phase load takes 100 kW at a power factor of 0.8 lagging from a 480 V (line-to-line), 60 Hz supply. A three-phase capacitor bank in parallel with the load must raise the overall power factor to 0.92 lagging. The real power stays the same. Find the total reactive power QC the capacitor bank must supply, in kvar.
P = 100 kWpf1 = 0.8pf2 = 0.92VL = 480 Vf = 60 Hz
QC = kvar
15.TransformersMedium
A single-phase 50 kVA, 4800/240 V transformer operates at its rated load. Treat it as ideal. Find the current ILV in the low-voltage winding.
S = 50 kVAV1 = 4800 VV2 = 240 V
ILV = A
16.TransformersHard
A single-phase 250 kVA transformer has a core loss of 1250 W and a copper loss of 3750 W at rated load. It supplies 25% of its rated kVA at a power factor of 0.95 lagging. Find the total losses Ploss in watts at this load.
Series and parallel resistors: in series the same current flows through each resistor and R = R₁ + R₂ + …. In parallel each resistor has the same voltage and 1/R = 1/R₁ + 1/R₂ + …. A ladder network is reduced one pair at a time until a single equivalent resistance remains.
Combine resistors from the far end
Start at the end farthest from the source and work back towards it. Resistors carrying the same current are in series; resistors across the same two nodes are in parallel.
R3 + R4 = 8 + 20 = 28 Ω
R2 ∥ 28 = 20·28/(20+28) = 11.67 Ω
Req = R1 + 11.67 = 4 + 11.67 = 15.67 Ω
Answer
Req = 15.67 Ω
2.Series & parallel resistors
Answer: IR2 = 0.122 A
Series and parallel resistors: in series the same current flows through each resistor and R = R₁ + R₂ + …. In parallel each resistor has the same voltage and 1/R = 1/R₁ + 1/R₂ + …. A ladder network is reduced one pair at a time until a single equivalent resistance remains.
Combine resistors from the far end
Start at the end farthest from the source and work back towards it. Resistors carrying the same current are in series; resistors across the same two nodes are in parallel.
R5 + R6 = 2 + 2 = 4 Ω
R4 ∥ 4 = 1.714 Ω
R3 + 1.714 = 6.714 Ω
R2 ∥ 6.714 = 3.65 Ω
Req = R1 + 3.65 = 30 + 3.65 = 33.65 Ω
Current from the source
The source sees only Req, so Ohm’s law gives the current it delivers. That current flows through R₁.
IR1 = V1/Req = 9/33.65 = 0.2675 A
Current through R₂
Subtract the drop across R₁ to get the voltage at node A, which is the voltage across R₂.
VA = V1 − IR1·R1 = 9 − 0.2675·30 = 0.9763 V
IR2 = VA/R2 = 0.9763/8 = 0.122 A
Answer
IR2 = 0.122 A
3.Nodal analysis
Answer: IR3 = −1.364 A
Nodal analysis: choose a reference node, label the unknown node voltages, write Kirchhoff’s current law at each unknown node using Ohm’s law (I = ΔV/R), and solve the resulting equations.
Set up the nodes
Ground is the bottom wire. Known node voltages come straight from the sources (V1 = 10 V). Unknowns: VA, VB.
KCL at node A
Currents leaving A through the resistors equal the current pushed into A by sources.
VA/R2 + (VA − V1)/R1 + (VA − VB)/R3 = 0
VA/3 + (VA − 10)/10 + (VA − VB)/2 = 0
0.9333·VA − 0.5·VB = 1
KCL at node B
Currents leaving B through the resistors equal the current pushed into B by sources.
VB/R4 + (VB − VA)/R3 = Is
VB/5 + (VB − VA)/2 = 3
−0.5·VA + 0.7·VB = 3
Solve
Δ = (0.9333)(0.7) − (−0.5)(−0.5) = 0.4033
VA = Δ1/Δ = 2.2/0.4033 = 5.455 V
VB = Δ2/Δ = 3.3/0.4033 = 8.182 V
Answer
IR3 = (VA − VB)/R3 = (5.455 − 8.182)/2 = −1.364 A
4.Nodal analysis
Answer: IR4 = 3.765 A
Nodal analysis: choose a reference node, label the unknown node voltages, write Kirchhoff’s current law at each unknown node using Ohm’s law (I = ΔV/R), and solve the resulting equations.
KCL at node A
Currents leaving A through the resistors equal the current pushed into A by sources.
(VA − V1)/R1 + VA/R2 + (VA − VB)/R3 = 0
0.4333·VA − 0.06667·VB = 8
KCL at node B
The dependent source pushes g·VA into node B. Treat it like an independent source, then move the VA term to the left-hand side.
Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.
Find Rth with every source switched off
Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.
R1 ∥ R2 = 10·15/(10+15) = 6 Ω
Rth = (R1 ∥ R2) + R3 = 6 + 5 = 11 Ω
6.Thévenin & Norton
Answer: IN = −2.583 A
Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.
Find Rth with every source switched off
Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.
R1 ∥ R2 = 6·12/(6+12) = 4 Ω
Rth = (R1 ∥ R2) + R3 = 4 + 20 = 24 Ω
Find Vth, the open-circuit voltage
With a–b open, the only path for Iₛ is through R₃ into node A. Find V_A by superposition of V₁ and Iₛ, then add the drop across R₃.
VA = V1·R2/(R1+R2) + Is·(R1∥R2) = 10 + (−3)·4 = −2 V
Vth = VB = VA + Is·R3 = −2 + (−3)·20 = −62 V
Norton equivalent
A Norton source is the same circuit seen as a current source in parallel with R_th. Its current is the short-circuit current at a–b.
IN = Vth/Rth = −62/24 = −2.583 A
7.RC & RL transients
Answer: t = 1.386 ms
First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.
Time constant
τ = L/R = 100 mH / 100 Ω = 1 ms
Solve for the time
0.125 = 0.5·e−t/τ → t = τ·ln(0.5/0.125)
t = 1·ln(4) = 1.386 ms
Answer
t = 1.386 ms
8.RC & RL transients
Answer: i2 = 0.0694 mA
First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.
Initial capacitor voltage
In steady state the capacitor is an open circuit, so R₁ and R₂ form a voltage divider. The capacitor voltage cannot jump when the switch opens.
vC(0) = 6·3.3/(2.2 + 3.3) = 3.6 V
Time constant after the switch opens
τ = R2·C = 3.3·22 = 72.6 ms
Discharge
vC(t) = 3.6·e−200/72.6 = 0.229 V
i2 = vC/R2 = 0.229/3.3 = 0.0694 mA
Answer
i2 = 0.0694 mA
9.AC impedance & phasors
Answer: L = 460.6 mH
AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.
Resonance condition
At resonance the inductive and capacitive reactances cancel: ωL = 1/(ωC).
ω₀ = 2π·500 = 3142 rad/s
L = 1/(ω₀²·C) = 1/(3142²·0.22·10⁻⁶) = 460.6 mH
Answer
L = 460.6 mH
10.AC impedance & phasors
Answer: VL = 7.071 V
AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.
Resonance
At resonance the reactances cancel, so the impedance is just R.
ω₀ = 1/√(LC) = 1/√(0.005·1·10⁻⁶) = 14142 rad/s
I = V/R = 1/10 = 0.1 A
Voltage across the inductor
XL = ω₀L = 14142·0.005 = 70.71 Ω
VL = I·XL = 0.1·70.71 = 7.071 V
Answer
VL = 7.071 V
This is Q = 7.071 times the supply voltage.
11.AC power & power factor
Answer: I = 127.8 A
AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.
Line current
Only the real part of the power does work, so divide by the power factor.
I = P/(V·cos φ) = 23000/(240·0.75) = 127.8 A
Answer
I = 127.8 A
12.AC power & power factor
Answer: C = 530.5 µF
AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.
Conjugate match
The load reactance cancels the source reactance, and the load resistance equals the source resistance.
ZL = Zs* = 4 − j5 Ω
Capacitance
XC = 5 Ω → C = 1/(2π·60·5) = 530.5 µF
Answer
C = 530.5 µF
13.Three-phase power
Answer: P = 9.699 kW
Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ.
Apparent power
S = √3·VL·IL = √3·400·20 = 13.86 kVA
Real power
P = S·cos φ = 13.86·0.7 = 9.699 kW
Answer
P = 9.699 kW
14.Three-phase power
Answer: QC = 32.4 kvar
Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ. Power factor correction: capacitors supply reactive power locally, QC = P·(tan φ1 − tan φ2). Each of the three capacitors supplies QC/3 = V²·ω·C, where V is the voltage across that capacitor: VL in a Δ bank, VL/√3 in a Y bank.
Reactive power before and after
The real power is unchanged, so each power factor fixes the reactive power: Q = P·tan φ.
Q1 = 100·tan(acos 0.8) = 100·0.75 = 75 kvar
Q2 = 100·tan(acos 0.92) = 100·0.426 = 42.6 kvar
Reactive power from the capacitors
QC = Q1 − Q2 = 32.4 kvar
Answer
QC = 32.4 kvar
15.Transformers
Answer: ILV = 208.3 A
Ideal transformer: the voltages are in the ratio of the turns and the currents in the inverse ratio: V₁/V₂ = N₁/N₂ = a and I₁/I₂ = N₂/N₁ = 1/a, so the power in equals the power out, V₁·I₁ = V₂·I₂. A load impedance Z on the secondary looks like a²·Z from the primary.
Rated current
Both windings carry the same apparent power.
ILV = S/V = 50000/240 = 208.3 A
Answer
ILV = 208.3 A
16.Transformers
Answer: Ploss = 1484 W
Transformer losses: the core loss (hysteresis and eddy currents) depends on the voltage and is the same at any load. The copper loss in the windings goes with the current squared, so at a fraction x of rated load it is x²·Pcu,fl. Efficiency η = Pout/(Pout + Pcore + Pcu), with Pout = x·S·pf. The efficiency is highest at the load where the copper loss equals the core loss.