Three branches are connected between node A and ground, as shown. Use nodal analysis to find the current I1 in branch 1, flowing up into node A in the direction of the arrow.
The diamond is a voltage-controlled current source that pushes a current of 0.1·VA (in A, with VA in V) up into node B. Use nodal analysis to find the node voltage VA (measured from ground).
Find the Thévenin voltage Vth seen from terminals a–b.
V1 = 24 VR1 = 5 ΩR2 = 4 ΩR3 = 4 Ω
Vth = V
6.Thévenin & NortonHard
Find the Norton current IN: the current that flows from a to b if the terminals are shorted.
V1 = 6 VIs = 0.5 AR1 = 12 ΩR2 = 5 ΩR3 = 30 Ω
IN = A
7.RC & RL transientsMedium
The inductor carries no current before the switch closes at t = 0. Find the current i at t = 1 ms.
Vs = 10 VR = 50 ΩL = 47 mHt = 1 ms
i = A
8.RC & RL transientsHard
The switch has been closed for a long time, so the circuit is in steady state. At t = 0 the switch opens. Find the capacitor voltage vC at t = 200 ms.
Vs = 12 VR1 = 6.8 kΩR2 = 4.7 kΩC = 33 µFt = 200 ms
vC = V
9.AC impedance & phasorsMedium
A series RLC circuit is connected to a 10 V (rms), 200 Hz supply. Find the phase angle φ of the impedance, in degrees (positive when the current lags the voltage).
V = 10 V (rms)f = 200 HzR = 100 ΩL = 250 mHC = 100 µF
φ = °
10.AC impedance & phasorsHard
A series RLC circuit has R = 10 Ω, L = 2 mH and C = 0.047 µF. Find its quality factor Q at resonance.
R = 10 ΩL = 2 mHC = 0.047 µF
Q =
11.AC power & power factorMedium
A single-phase motor takes 22 kW at a power factor of 0.6 lagging from a 230 V supply. Find the reactive power Q it draws.
P = 22 kWpf = 0.6V = 230 V
Q = kvar
12.AC power & power factorHard
A 10 V (rms), 60 Hz source has an internal impedance Zs = 25 + j15 Ω. The load impedance ZL can be chosen freely. Find the maximum real power Pmax that can be delivered to the load.
Vs = 10 V (rms)f = 60 HzZs = 25 + j15 Ω
Pmax = W
13.Three-phase powerMedium
A balanced three-phase load draws a line current of 40 A from a supply with a line-to-line voltage of 415 V. The power factor is 0.75 lagging. Find the total real power P drawn by the load in kW.
VL = 415 VIL = 40 Acos φ = 0.75
P = kW
14.Three-phase powerHard
A balanced three-phase load takes 75 kW at a power factor of 0.78 lagging from a 480 V (line-to-line), 50 Hz supply. A three-phase capacitor bank in parallel with the load must raise the overall power factor to 0.9 lagging. The real power stays the same. Find the total reactive power QC the capacitor bank must supply, in kvar.
P = 75 kWpf1 = 0.78pf2 = 0.9VL = 480 Vf = 50 Hz
QC = kvar
15.TransformersMedium
An ideal transformer with a turns ratio N₁:N₂ = 20:1 has 4800 V applied to its primary winding. A 12 Ω resistor is connected across the secondary winding. Find the primary current I1.
N1:N2 = 20:1V1 = 4800 VRL = 12 Ω
I1 = A
16.TransformersHard
A single-phase 250 kVA transformer has a core loss of 1250 W and a copper loss of 3125 W at rated load. It supplies 75% of its rated kVA at a power factor of 0.85 lagging. Find the total losses Ploss in watts at this load.
Series and parallel resistors: in series the same current flows through each resistor and R = R₁ + R₂ + …. In parallel each resistor has the same voltage and 1/R = 1/R₁ + 1/R₂ + …. A ladder network is reduced one pair at a time until a single equivalent resistance remains.
Combine resistors from the far end
Start at the end farthest from the source and work back towards it. Resistors carrying the same current are in series; resistors across the same two nodes are in parallel.
R3 + R4 = 3 + 15 = 18 Ω
R2 ∥ 18 = 8·18/(8+18) = 5.538 Ω
Req = R1 + 5.538 = 4 + 5.538 = 9.538 Ω
Current from the source
The source sees only Req, so Ohm’s law gives the current it delivers. That current flows through R₁.
IR1 = V1/Req = 9/9.538 = 0.9435 A
Answer
IR1 = 0.9435 A
2.Series & parallel resistors
Answer: Req = 35.11 Ω
Series and parallel resistors: in series the same current flows through each resistor and R = R₁ + R₂ + …. In parallel each resistor has the same voltage and 1/R = 1/R₁ + 1/R₂ + …. A ladder network is reduced one pair at a time until a single equivalent resistance remains.
Combine resistors from the far end
Start at the end farthest from the source and work back towards it. Resistors carrying the same current are in series; resistors across the same two nodes are in parallel.
R5 + R6 = 5 + 8 = 13 Ω
R4 ∥ 13 = 6.964 Ω
R3 + 6.964 = 16.96 Ω
R2 ∥ 16.96 = 10.11 Ω
Req = R1 + 10.11 = 25 + 10.11 = 35.11 Ω
Answer
Req = 35.11 Ω
3.Nodal analysis
Answer: I1 = 3.375 A
Nodal analysis: choose a reference node, label the unknown node voltages, write Kirchhoff’s current law at each unknown node using Ohm’s law (I = ΔV/R), and solve the resulting equations.
KCL at node A
Take the bottom wire as ground. Each branch carries (VA − Vk)/Rk away from A, where Vk is the voltage of its source (zero for a plain resistor). The currents leaving A add up to zero.
(VA − 24)/8 + (VA − (−18))/3 + (VA − 10)/8 = 0
Solve for VA
VA = (24/8 + (−18)/3 + 10/8) / (1/8 + 1/3 + 1/8) = −1.75/0.5833 = −3 V
Branch current
The arrow points up through the branch, into node A.
I1 = (24 − VA)/R1 = (24 − (−3))/8 = 3.375 A
Answer
I1 = 3.375 A
A negative result means the real current flows against the arrow.
4.Nodal analysis
Answer: VA = 13.89 V
Nodal analysis: choose a reference node, label the unknown node voltages, write Kirchhoff’s current law at each unknown node using Ohm’s law (I = ΔV/R), and solve the resulting equations.
KCL at node A
Currents leaving A through the resistors equal the current pushed into A by sources.
(VA − V1)/R1 + VA/R2 + (VA − VB)/R3 = 0
0.225·VA − 0.05·VB = 1.875
KCL at node B
The dependent source pushes g·VA into node B. Treat it like an independent source, then move the VA term to the left-hand side.
(VB − VA)/R3 + VB/R4 = 0.1·VA
−0.15·VA + 0.08333·VB = 0
Solve
Δ = (0.225)(0.08333) − (−0.05)(−0.15) = 0.01125
VA = Δ1/Δ = 0.1563/0.01125 = 13.89 V
VB = Δ2/Δ = 0.2813/0.01125 = 25 V
Answer
VA = 13.89 V
5.Thévenin & Norton
Answer: Vth = 10.67 V
Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.
Find Rth with every source switched off
Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.
R1 ∥ R2 = 5·4/(5+4) = 2.222 Ω
Rth = (R1 ∥ R2) + R3 = 2.222 + 4 = 6.222 Ω
Find Vth, the open-circuit voltage
With a–b open, no current flows through R₃, so there is no drop across it and V_b = V_A. R₁ and R₂ form a voltage divider.
Vth = V1·R2/(R1+R2) = 24·4/(5+4) = 10.67 V
6.Thévenin & Norton
Answer: IN = 0.5526 A
Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.
Find Rth with every source switched off
Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.
R1 ∥ R2 = 12·5/(12+5) = 3.529 Ω
Rth = (R1 ∥ R2) + R3 = 3.529 + 30 = 33.53 Ω
Find Vth, the open-circuit voltage
With a–b open, the only path for Iₛ is through R₃ into node A. Find V_A by superposition of V₁ and Iₛ, then add the drop across R₃.
VA = V1·R2/(R1+R2) + Is·(R1∥R2) = 1.765 + 0.5·3.529 = 3.529 V
Vth = VB = VA + Is·R3 = 3.529 + 0.5·30 = 18.53 V
Norton equivalent
A Norton source is the same circuit seen as a current source in parallel with R_th. Its current is the short-circuit current at a–b.
IN = Vth/Rth = 18.53/33.53 = 0.5526 A
7.RC & RL transients
Answer: i = 0.131 A
First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.
Time constant and final current
Long after the switch closes the inductor behaves like a short circuit, so the final current is set by R alone.
First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.
Initial capacitor voltage
In steady state the capacitor is an open circuit, so R₁ and R₂ form a voltage divider. The capacitor voltage cannot jump when the switch opens.
vC(0) = 12·4.7/(6.8 + 4.7) = 4.904 V
Time constant after the switch opens
τ = R2·C = 4.7·33 = 155.1 ms
Discharge
vC(t) = 4.904·e−200/155.1 = 1.351 V
Answer
vC = 1.351 V
9.AC impedance & phasors
Answer: φ = 71.91 °
AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.
Reactances
ω = 2πf = 2π·200 = 1257 rad/s
XL = ωL = 1257·0.25 = 314.2 Ω
XC = 1/(ωC) = 1/(1257·100·10⁻⁶) = 7.958 Ω
Impedance
In series the impedances add as complex numbers: Z = R + j(XL − XC).
AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.
Resonant frequency
f0 = 1/(2π·√(0.002·0.047·10⁻⁶)) = 16416 Hz
Quality factor
Q compares the reactance at resonance with the resistance: Q = ω₀L/R.
AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.
Angle
φ = arccos(0.6) = 53.13°, tan φ = 1.333
Reactive power
Q = P·tan φ = 22·1.333 = 29.33 kvar
Answer
Q = 29.33 kvar
12.AC power & power factor
Answer: Pmax = 1 W
AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.
Conjugate match
The load reactance cancels the source reactance, and the load resistance equals the source resistance.
ZL = Zs* = 25 − j15 Ω
Maximum power
I = Vs/(2Rs) = 10/50 = 0.2 A
Pmax = I²·RL = Vs²/(4Rs) = 10²/(4·25) = 1 W
Answer
Pmax = 1 W
13.Three-phase power
Answer: P = 21.56 kW
Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ.
Apparent power
S = √3·VL·IL = √3·415·40 = 28.75 kVA
Real power
P = S·cos φ = 28.75·0.75 = 21.56 kW
Answer
P = 21.56 kW
14.Three-phase power
Answer: QC = 23.85 kvar
Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ. Power factor correction: capacitors supply reactive power locally, QC = P·(tan φ1 − tan φ2). Each of the three capacitors supplies QC/3 = V²·ω·C, where V is the voltage across that capacitor: VL in a Δ bank, VL/√3 in a Y bank.
Reactive power before and after
The real power is unchanged, so each power factor fixes the reactive power: Q = P·tan φ.
Q1 = 75·tan(acos 0.78) = 75·0.8023 = 60.17 kvar
Q2 = 75·tan(acos 0.9) = 75·0.4843 = 36.32 kvar
Reactive power from the capacitors
QC = Q1 − Q2 = 23.85 kvar
Answer
QC = 23.85 kvar
15.Transformers
Answer: I1 = 1 A
Ideal transformer: the voltages are in the ratio of the turns and the currents in the inverse ratio: V₁/V₂ = N₁/N₂ = a and I₁/I₂ = N₂/N₁ = 1/a, so the power in equals the power out, V₁·I₁ = V₂·I₂. A load impedance Z on the secondary looks like a²·Z from the primary.
Secondary voltage and current
V2 = 4800/20 = 240 V
I2 = 240/12 = 20 A
Primary current
An ideal transformer has no losses: V₁·I₁ = V₂·I₂.
I1 = I2/20 = 1 A
Answer
I1 = 1 A
Check: the load seen from the primary is a²·RL = 4800 Ω, and 4800/4800 gives the same current.
16.Transformers
Answer: Ploss = 3008 W
Transformer losses: the core loss (hysteresis and eddy currents) depends on the voltage and is the same at any load. The copper loss in the windings goes with the current squared, so at a fraction x of rated load it is x²·Pcu,fl. Efficiency η = Pout/(Pout + Pcore + Pcu), with Pout = x·S·pf. The efficiency is highest at the load where the copper loss equals the core loss.