The voltage source Vₛ between A and B has its + terminal at B, so it makes VB − VA = Vₛ. Use nodal analysis with a supernode to find the node voltage VB (measured from ground).
Find the Norton current IN: the current that flows from a to b if the terminals are shorted.
V1 = 12 VR1 = 10 ΩR2 = 4 ΩR3 = 6 Ω
IN = A
6.Thévenin & NortonHard
Find the Thévenin voltage Vth seen from terminals a–b.
V1 = 18 VIs = 4 AR1 = 3 ΩR2 = 5 ΩR3 = 25 Ω
Vth = V
7.RC & RL transientsMedium
The source Vₛ charges the capacitor through R₁, and R₂ is connected in parallel with C. The capacitor is uncharged when the switch closes at t = 0. Find the capacitor voltage vC at t = 80 ms.
Vs = 9 VR1 = 2.2 kΩR2 = 4.7 kΩC = 100 µFt = 80 ms
vC = V
8.RC & RL transientsHard
The switch across R2 has been closed for a long time, so the inductor current is steady. At t = 0 the switch opens. How long after t = 0 does the inductor current reach 0.725 A? Find t.
Vs = 10 VR1 = 10 ΩR2 = 22 ΩL = 33 mH
t = ms
9.AC impedance & phasorsMedium
A resistor and an inductor are connected in parallel across a 12 V (rms), 50 Hz supply. Find the phase angle φ of the impedance, in degrees (positive when the current lags the voltage).
V = 12 V (rms)f = 50 HzR = 50 ΩL = 150 mH
φ = °
10.AC impedance & phasorsHard
A series RLC circuit has R = 100 Ω, L = 10 mH and C = 0.022 µF. Find its quality factor Q at resonance.
R = 100 ΩL = 10 mHC = 0.022 µF
Q =
11.AC power & power factorMedium
A single-phase motor takes 10 kW at a power factor of 0.65 lagging from a 240 V supply. Find the reactive power Q it draws.
P = 10 kWpf = 0.65V = 240 V
Q = kvar
12.AC power & power factorHard
A single-phase load takes 25 kW at a power factor of 0.75 lagging from a 240 V, 60 Hz supply. A capacitor connected in parallel raises the power factor to 0.92. Find the capacitance C needed.
P = 25 kWpf1 = 0.75pf2 = 0.92V = 240 Vf = 60 Hz
C = µF
13.Three-phase powerMedium
A balanced three-phase load draws a line current of 20 A from a supply with a line-to-line voltage of 480 V. The power factor is 0.92 lagging. Find the total real power P drawn by the load in kW.
VL = 480 VIL = 20 Acos φ = 0.92
P = kW
14.Three-phase powerHard
A balanced three-phase load takes 100 kW at a power factor of 0.75 lagging from a 400 V (line-to-line), 50 Hz supply. A three-phase capacitor bank in parallel with the load must raise the overall power factor to 0.92 lagging. The real power stays the same. The capacitors are connected in Δ. Find the capacitance Cph of each capacitor in µF.
P = 100 kWpf1 = 0.75pf2 = 0.92VL = 400 Vf = 50 Hz
Cph = µF
15.TransformersMedium
A 16 Ω resistor is connected across the secondary winding of an ideal transformer with a turns ratio N₁:N₂ = 12:1. Find the resistance R1′ seen looking into the primary winding.
N1:N2 = 12:1RL = 16 Ω
R1′ = Ω
16.TransformersHard
A single-phase 200 kVA transformer has a core loss of 1600 W and a copper loss of 4000 W at rated load. At what load Sη,max, in kVA, is its efficiency highest?
S = 200 kVAPcore = 1600 WPcu,fl = 4000 W
Sη,max = kVA
3Solutions
1.Series & parallel resistors
Answer: Req = 6.4 Ω
Series and parallel resistors: in series the same current flows through each resistor and R = R₁ + R₂ + …. In parallel each resistor has the same voltage and 1/R = 1/R₁ + 1/R₂ + …. A ladder network is reduced one pair at a time until a single equivalent resistance remains.
Combine resistors from the far end
Start at the end farthest from the source and work back towards it. Resistors carrying the same current are in series; resistors across the same two nodes are in parallel.
R3 + R4 = 2 + 10 = 12 Ω
R2 ∥ 12 = 3·12/(3+12) = 2.4 Ω
Req = R1 + 2.4 = 4 + 2.4 = 6.4 Ω
Answer
Req = 6.4 Ω
2.Series & parallel resistors
Answer: Req = 7.438 Ω
Series and parallel resistors: in series the same current flows through each resistor and R = R₁ + R₂ + …. In parallel each resistor has the same voltage and 1/R = 1/R₁ + 1/R₂ + …. A ladder network is reduced one pair at a time until a single equivalent resistance remains.
Combine resistors from the far end
Start at the end farthest from the source and work back towards it. Resistors carrying the same current are in series; resistors across the same two nodes are in parallel.
R5 + R6 = 5 + 25 = 30 Ω
R4 ∥ 30 = 5 Ω
R3 + 5 = 13 Ω
R2 ∥ 13 = 2.438 Ω
Req = R1 + 2.438 = 5 + 2.438 = 7.438 Ω
Answer
Req = 7.438 Ω
3.Nodal analysis
Answer: IR1 = 0.3333 A
Nodal analysis: choose a reference node, label the unknown node voltages, write Kirchhoff’s current law at each unknown node using Ohm’s law (I = ΔV/R), and solve the resulting equations.
Set up the nodes
Ground is the bottom wire. Known node voltages come straight from the sources (V1 = 12 V). Unknowns: VA, VB.
KCL at node A
Currents leaving A through the resistors equal the current pushed into A by sources.
VA/R2 + (VA − V1)/R1 + (VA − VB)/R3 = 0
VA/20 + (VA − 12)/20 + (VA − VB)/3 = 0
0.4333·VA − 0.3333·VB = 0.6
KCL at node B
Currents leaving B through the resistors equal the current pushed into B by sources.
VB/R4 + (VB − VA)/R3 = Is
VB/2 + (VB − VA)/3 = 2.5
−0.3333·VA + 0.8333·VB = 2.5
Solve
Δ = (0.4333)(0.8333) − (−0.3333)(−0.3333) = 0.25
VA = Δ1/Δ = 1.333/0.25 = 5.333 V
VB = Δ2/Δ = 1.283/0.25 = 5.133 V
Answer
IR1 = (V1 − VA)/R1 = (12 − 5.333)/20 = 0.3333 A
4.Nodal analysis
Answer: VB = 17.19 V
Nodal analysis: choose a reference node, label the unknown node voltages, write Kirchhoff’s current law at each unknown node using Ohm’s law (I = ΔV/R), and solve the resulting equations.
Form a supernode
The voltage source between A and B carries an unknown current, so KCL cannot be written at A or B separately. Enclose A, B and the source in one supernode: the current entering it equals the current leaving it.
Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.
Find Rth with every source switched off
Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.
R1 ∥ R2 = 10·4/(10+4) = 2.857 Ω
Rth = (R1 ∥ R2) + R3 = 2.857 + 6 = 8.857 Ω
Find Vth, the open-circuit voltage
With a–b open, no current flows through R₃, so there is no drop across it and V_b = V_A. R₁ and R₂ form a voltage divider.
Vth = V1·R2/(R1+R2) = 12·4/(10+4) = 3.429 V
Norton equivalent
A Norton source is the same circuit seen as a current source in parallel with R_th. Its current is the short-circuit current at a–b.
IN = Vth/Rth = 3.429/8.857 = 0.3871 A
6.Thévenin & Norton
Answer: Vth = −96.25 V
Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.
Find Rth with every source switched off
Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.
R1 ∥ R2 = 3·5/(3+5) = 1.875 Ω
Rth = (R1 ∥ R2) + R3 = 1.875 + 25 = 26.88 Ω
Find Vth, the open-circuit voltage
With a–b open, the only path for Iₛ is through R₃ into node A. Find V_A by superposition of V₁ and Iₛ, then add the drop across R₃.
VA = V1·R2/(R1+R2) + Is·(R1∥R2) = 11.25 + (−4)·1.875 = 3.75 V
Vth = VB = VA + Is·R3 = 3.75 + (−4)·25 = −96.25 V
7.RC & RL transients
Answer: vC = 2.536 V
First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.
Thévenin equivalent seen by the capacitor
Short the source to find Rth; open the capacitor to find the voltage it will settle at.
Rth = R1 ∥ R2 = 2.2·4.7/(2.2 + 4.7) = 1.499 kΩ
vC(∞) = 9·4.7/(2.2 + 4.7) = 6.13 V
Time constant
τ = Rth·C = 1.499·100 = 149.9 ms
Charging curve
vC(t) = 6.13·(1 − e−80/149.9) = 2.536 V
Answer
vC = 2.536 V
8.RC & RL transients
Answer: t = 0.5268 ms
First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.
Initial value, final value, time constant
Before t = 0 the closed switch bypasses R₂; afterwards R₁ and R₂ are both in the loop.
i(0) = 10/10 = 1 A
i(∞) = 10/(10 + 22) = 0.3125 A
τ = L/R = 33/32 = 1.031 ms
i(t) = 0.3125 + (1 − 0.3125)·e−t/τ
Solve for the time
e−t/τ = (0.725 − 0.3125)/(1 − 0.3125) = 0.6
t = 1.031·ln(1.667) = 0.5268 ms
Answer
t = 0.5268 ms
9.AC impedance & phasors
Answer: φ = 46.7 °
AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.
Reactance
XL = ωL = 2π·50·0.15 = 47.12 Ω
Branch currents
Both branches are connected straight across the supply, so each sees the full voltage V.
IR = V/R = 12/50 = 0.24 A
IX = V/XL = 12/47.12 = 0.2546 A
Total current
The resistor current is in phase with V and the reactive current is 90° out of phase, so they add like the sides of a right triangle.
I = √(IR² + IX²) = √(0.24² + 0.2546²) = 0.3499 A
Phase angle
The inductor current lags V, so the total current lags and the angle is positive.
φ = arctan(IX/IR) = arctan(0.2546/0.24) = 46.7°
Answer
φ = 46.7°
10.AC impedance & phasors
Answer: Q = 6.742
AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.
Resonant frequency
f0 = 1/(2π·√(0.01·0.022·10⁻⁶)) = 10730 Hz
Quality factor
Q compares the reactance at resonance with the resistance: Q = ω₀L/R.
AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.
Angle
φ = arccos(0.65) = 49.46°, tan φ = 1.169
Reactive power
Q = P·tan φ = 10·1.169 = 11.69 kvar
Answer
Q = 11.69 kvar
12.AC power & power factor
Answer: C = 524.9 µF
AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.
Reactive power before and after
The real power P does not change; only the reactive power drawn from the supply does.
Q1 = P·tan φ1 = 25·tan(41.41°) = 22.05 kvar
Q2 = P·tan φ2 = 25·tan(23.07°) = 10.65 kvar
QC = Q1 − Q2 = 11.4 kvar
Capacitance
A capacitor across the supply delivers Q = V²·ωC.
C = QC/(2πf·V²) = 11398/(2π·60·240²) = 524.9 µF
Answer
C = 524.9 µF
13.Three-phase power
Answer: P = 15.3 kW
Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ.
Apparent power
S = √3·VL·IL = √3·480·20 = 16.63 kVA
Real power
P = S·cos φ = 16.63·0.92 = 15.3 kW
Answer
P = 15.3 kW
14.Three-phase power
Answer: Cph = 302.3 µF
Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ. Power factor correction: capacitors supply reactive power locally, QC = P·(tan φ1 − tan φ2). Each of the three capacitors supplies QC/3 = V²·ω·C, where V is the voltage across that capacitor: VL in a Δ bank, VL/√3 in a Y bank.
Reactive power before and after
The real power is unchanged, so each power factor fixes the reactive power: Q = P·tan φ.
Q1 = 100·tan(acos 0.75) = 100·0.8819 = 88.19 kvar
Q2 = 100·tan(acos 0.92) = 100·0.426 = 42.6 kvar
Reactive power from the capacitors
QC = Q1 − Q2 = 45.59 kvar
Capacitance per phase
In a Δ bank each capacitor is connected between two lines.
Ideal transformer: the voltages are in the ratio of the turns and the currents in the inverse ratio: V₁/V₂ = N₁/N₂ = a and I₁/I₂ = N₂/N₁ = 1/a, so the power in equals the power out, V₁·I₁ = V₂·I₂. A load impedance Z on the secondary looks like a²·Z from the primary.
Referred resistance
The voltage goes up by a and the current down by a, so the ratio V/I goes up by a².
R1′ = a²·RL = 12²·16 = 2304 Ω
Answer
R1′ = 2304 Ω
16.Transformers
Answer: Sη,max = 126.5 kVA
Transformer losses: the core loss (hysteresis and eddy currents) depends on the voltage and is the same at any load. The copper loss in the windings goes with the current squared, so at a fraction x of rated load it is x²·Pcu,fl. Efficiency η = Pout/(Pout + Pcore + Pcu), with Pout = x·S·pf. The efficiency is highest at the load where the copper loss equals the core loss.