The diamond is a voltage-controlled current source that pushes a current of 0.1·VA (in A, with VA in V) up into node B. Use nodal analysis to find the current IR4 through R4 in the direction of the arrow.
The inductor carries no current before the switch closes at t = 0. Find the voltage vL across the inductor at t = 1 ms.
Vs = 6 VR = 33 ΩL = 33 mHt = 1 ms
vL = V
8.RC & RL transientsHard
The switch has been closed for a long time, so the circuit is in steady state. At t = 0 the switch opens. Find the current i2 through R2 at t = 60 ms.
Vs = 20 VR1 = 1 kΩR2 = 2.2 kΩC = 22 µFt = 60 ms
i2 = mA
9.AC impedance & phasorsMedium
A series RLC circuit is connected to a 12 V (rms), 500 Hz supply. Find the power factor cos φ of the circuit.
V = 12 V (rms)f = 500 HzR = 60 ΩL = 150 mHC = 22 µF
cos φ =
10.AC impedance & phasorsHard
A series RLC circuit is driven by a 24 V (rms) source whose frequency is set to the resonant frequency of the circuit. Find the rms voltage VL across the inductor.
V = 24 V (rms)R = 15 ΩL = 200 mHC = 10 µF
VL = V
11.AC power & power factorMedium
A single-phase motor takes 25 kW at a power factor of 0.7 lagging from a 240 V supply. Find the line current I.
P = 25 kWpf = 0.7V = 240 V
I = A
12.AC power & power factorHard
A 200 kVA single-phase transformer supplies a load of 125 kW at a power factor of 0.8 lagging. How much extra real power ΔP can be added as a resistive (unity power factor) load before the transformer reaches its kVA rating?
Smax = 200 kVAP1 = 125 kWpf1 = 0.8
ΔP = kW
13.Three-phase powerMedium
A three-phase induction motor delivers 15 kW of mechanical output power at full load. At this load its efficiency is 95% and its power factor is 0.88 lagging. The supply has a line-to-line voltage of 480 V. Find the line current IL.
Pout = 15 kWη = 95%cos φ = 0.88VL = 480 V
IL = A
14.Three-phase powerHard
A balanced three-phase load takes 100 kW at a power factor of 0.75 lagging from a 480 V (line-to-line), 50 Hz supply. A three-phase capacitor bank in parallel with the load must raise the overall power factor to 0.98 lagging. The real power stays the same. The capacitors are connected in Δ. Find the capacitance Cph of each capacitor in µF.
P = 100 kWpf1 = 0.75pf2 = 0.98VL = 480 Vf = 50 Hz
Cph = µF
15.TransformersMedium
An ideal transformer with a turns ratio N₁:N₂ = 5:1 has 600 V applied to its primary winding. A 30 Ω resistor is connected across the secondary winding. Find the primary current I1.
N1:N2 = 5:1V1 = 600 VRL = 30 Ω
I1 = A
16.TransformersHard
A single-phase 100 kVA transformer has a core loss of 800 W and a copper loss of 1600 W at rated load. At what load Sη,max, in kVA, is its efficiency highest?
S = 100 kVAPcore = 800 WPcu,fl = 1600 W
Sη,max = kVA
3Solutions
1.Series & parallel resistors
Answer: IR2 = 2.057 A
Series and parallel resistors: in series the same current flows through each resistor and R = R₁ + R₂ + …. In parallel each resistor has the same voltage and 1/R = 1/R₁ + 1/R₂ + …. A ladder network is reduced one pair at a time until a single equivalent resistance remains.
Combine resistors from the far end
Start at the end farthest from the source and work back towards it. Resistors carrying the same current are in series; resistors across the same two nodes are in parallel.
R3 + R4 = 6 + 10 = 16 Ω
R2 ∥ 16 = 2·16/(2+16) = 1.778 Ω
Req = R1 + 1.778 = 6 + 1.778 = 7.778 Ω
Current from the source
The source sees only Req, so Ohm’s law gives the current it delivers. That current flows through R₁.
IR1 = V1/Req = 18/7.778 = 2.314 A
Current through R₂
Subtract the drop across R₁ to get the voltage at node A, which is the voltage across R₂.
VA = V1 − IR1·R1 = 18 − 2.314·6 = 4.114 V
IR2 = VA/R2 = 4.114/2 = 2.057 A
Answer
IR2 = 2.057 A
2.Series & parallel resistors
Answer: IR1 = 0.4564 A
Series and parallel resistors: in series the same current flows through each resistor and R = R₁ + R₂ + …. In parallel each resistor has the same voltage and 1/R = 1/R₁ + 1/R₂ + …. A ladder network is reduced one pair at a time until a single equivalent resistance remains.
Combine resistors from the far end
Start at the end farthest from the source and work back towards it. Resistors carrying the same current are in series; resistors across the same two nodes are in parallel.
R5 + R6 = 20 + 20 = 40 Ω
R4 ∥ 40 = 3.636 Ω
R3 + 3.636 = 9.636 Ω
R2 ∥ 9.636 = 6.955 Ω
Req = R1 + 6.955 = 4 + 6.955 = 10.96 Ω
Current from the source
The source sees only Req, so Ohm’s law gives the current it delivers. That current flows through R₁.
IR1 = V1/Req = 5/10.96 = 0.4564 A
Answer
IR1 = 0.4564 A
3.Nodal analysis
Answer: PIs = 3.364 W
Nodal analysis: choose a reference node, label the unknown node voltages, write Kirchhoff’s current law at each unknown node using Ohm’s law (I = ΔV/R), and solve the resulting equations.
KCL at node A
Currents leaving A through the resistors equal the current pushed into A by sources.
VA/R2 + (VA − V1)/R1 + (VA − VB)/R3 = 0
VA/12 + (VA − 9)/8 + (VA − VB)/12 = 0
0.2917·VA − 0.08333·VB = 1.125
KCL at node B
Currents leaving B through the resistors equal the current pushed into B by sources.
The source pushes Iₛ up into node B, from ground (0 V) to VB. A source whose current leaves its + end delivers P = V·I.
PIs = VB·Is = 3.364·1 = 3.364 W
Answer
PIs = 3.364 W
4.Nodal analysis
Answer: IR4 = 1.391 A
Nodal analysis: choose a reference node, label the unknown node voltages, write Kirchhoff’s current law at each unknown node using Ohm’s law (I = ΔV/R), and solve the resulting equations.
KCL at node A
Currents leaving A through the resistors equal the current pushed into A by sources.
(VA − V1)/R1 + VA/R2 + (VA − VB)/R3 = 0
0.1233·VA − 0.03333·VB = 1.2
KCL at node B
The dependent source pushes g·VA into node B. Treat it like an independent source, then move the VA term to the left-hand side.
Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.
Find Rth with every source switched off
Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.
R1 ∥ R2 = 8·10/(8+10) = 4.444 Ω
Rth = (R1 ∥ R2) + R3 = 4.444 + 5 = 9.444 Ω
Find Vth, the open-circuit voltage
With a–b open, no current flows through R₃, so there is no drop across it and V_b = V_A. R₁ and R₂ form a voltage divider.
Vth = V1·R2/(R1+R2) = 12·10/(8+10) = 6.667 V
Connect the load to the Thévenin equivalent
The Thévenin source and R_th in series behave exactly like the original circuit at a–b, so the load sees a simple series loop.
IL = Vth/(Rth + RL) = 6.667/(9.444 + 15) = 0.2727 A
6.Thévenin & Norton
Answer: IL = 1.331 A
Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.
Find Rth with every source switched off
Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.
R1 ∥ R2 = 15·6/(15+6) = 4.286 Ω
Rth = (R1 ∥ R2) + R3 = 4.286 + 8 = 12.29 Ω
Find Vth, the open-circuit voltage
With a–b open, the only path for Iₛ is through R₃ into node A. Find V_A by superposition of V₁ and Iₛ, then add the drop across R₃.
VA = V1·R2/(R1+R2) + Is·(R1∥R2) = 8.571 + 1.5·4.286 = 15 V
Vth = VB = VA + Is·R3 = 15 + 1.5·8 = 27 V
Connect the load to the Thévenin equivalent
The Thévenin source and R_th in series behave exactly like the original circuit at a–b, so the load sees a simple series loop.
IL = Vth/(Rth + RL) = 27/(12.29 + 8) = 1.331 A
7.RC & RL transients
Answer: vL = 2.207 V
First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.
Time constant and final current
Long after the switch closes the inductor behaves like a short circuit, so the final current is set by R alone.
τ = L/R = 33 mH / 33 Ω = 1 ms
i(∞) = Vs/R = 6/33 = 0.1818 A
Inductor voltage
At t = 0 the whole supply voltage appears across the inductor; it then decays to zero.
vL(t) = Vs·e−t/τ = 6·e−1/1 = 2.207 V
Answer
vL = 2.207 V
8.RC & RL transients
Answer: i2 = 1.809 mA
First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.
Initial capacitor voltage
In steady state the capacitor is an open circuit, so R₁ and R₂ form a voltage divider. The capacitor voltage cannot jump when the switch opens.
vC(0) = 20·2.2/(1 + 2.2) = 13.75 V
Time constant after the switch opens
τ = R2·C = 2.2·22 = 48.4 ms
Discharge
vC(t) = 13.75·e−60/48.4 = 3.98 V
i2 = vC/R2 = 3.98/2.2 = 1.809 mA
Answer
i2 = 1.809 mA
9.AC impedance & phasors
Answer: cos φ = 0.1302
AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.
Reactances
XL = 471.2 Ω, XC = 14.47 Ω
Impedance
|Z| = √(60² + (456.8)²) = 460.7 Ω
Power factor
cos φ = R/|Z| = 60/460.7 = 0.1302
The circuit is inductive, so the power factor is lagging.
Answer
cos φ = 0.1302
10.AC impedance & phasors
Answer: VL = 226.3 V
AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.
Resonance
At resonance the reactances cancel, so the impedance is just R.
ω₀ = 1/√(LC) = 1/√(0.2·10·10⁻⁶) = 707.1 rad/s
I = V/R = 24/15 = 1.6 A
Voltage across the inductor
XL = ω₀L = 707.1·0.2 = 141.4 Ω
VL = I·XL = 1.6·141.4 = 226.3 V
Answer
VL = 226.3 V
This is Q = 9.428 times the supply voltage.
11.AC power & power factor
Answer: I = 148.8 A
AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.
Line current
Only the real part of the power does work, so divide by the power factor.
I = P/(V·cos φ) = 25000/(240·0.7) = 148.8 A
Answer
I = 148.8 A
12.AC power & power factor
Answer: ΔP = 51.67 kW
AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.
Reactive power of the existing load
Q1 = 125·tan(arccos 0.8) = 93.75 kvar
Largest total real power
At full rating S = Smax, and Q is unchanged by the resistive load.
P = √(Smax² − Q1²) = √(200² − 93.75²) = 176.7 kW
Extra real power
ΔP = 176.7 − 125 = 51.67 kW
Answer
ΔP = 51.67 kW
13.Three-phase power
Answer: IL = 21.58 A
Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ.
Electrical input power
Pin = Pout/η = 15/0.95 = 15.79 kW
Line current
IL = Pin/(√3·VL·cos φ) = 15789/(√3·480·0.88) = 21.58 A
Answer
IL = 21.58 A
14.Three-phase power
Answer: Cph = 312.6 µF
Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ. Power factor correction: capacitors supply reactive power locally, QC = P·(tan φ1 − tan φ2). Each of the three capacitors supplies QC/3 = V²·ω·C, where V is the voltage across that capacitor: VL in a Δ bank, VL/√3 in a Y bank.
Reactive power before and after
The real power is unchanged, so each power factor fixes the reactive power: Q = P·tan φ.
Q1 = 100·tan(acos 0.75) = 100·0.8819 = 88.19 kvar
Q2 = 100·tan(acos 0.98) = 100·0.2031 = 20.31 kvar
Reactive power from the capacitors
QC = Q1 − Q2 = 67.89 kvar
Capacitance per phase
In a Δ bank each capacitor is connected between two lines.
Ideal transformer: the voltages are in the ratio of the turns and the currents in the inverse ratio: V₁/V₂ = N₁/N₂ = a and I₁/I₂ = N₂/N₁ = 1/a, so the power in equals the power out, V₁·I₁ = V₂·I₂. A load impedance Z on the secondary looks like a²·Z from the primary.
Secondary voltage and current
V2 = 600/5 = 120 V
I2 = 120/30 = 4 A
Primary current
An ideal transformer has no losses: V₁·I₁ = V₂·I₂.
I1 = I2/5 = 0.8 A
Answer
I1 = 0.8 A
Check: the load seen from the primary is a²·RL = 750 Ω, and 600/750 gives the same current.
16.Transformers
Answer: Sη,max = 70.71 kVA
Transformer losses: the core loss (hysteresis and eddy currents) depends on the voltage and is the same at any load. The copper loss in the windings goes with the current squared, so at a fraction x of rated load it is x²·Pcu,fl. Efficiency η = Pout/(Pout + Pcore + Pcu), with Pout = x·S·pf. The efficiency is highest at the load where the copper loss equals the core loss.