Find the Thévenin voltage Vth seen from terminals a–b.
V1 = 6 VR1 = 6 ΩR2 = 15 ΩR3 = 12 Ω
Vth = V
6.Thévenin & NortonHard
Find the Thévenin voltage Vth seen from terminals a–b.
V1 = 6 VIs = 6 AR1 = 8 ΩR2 = 8 ΩR3 = 4 Ω
Vth = V
7.RC & RL transientsMedium
The source Vₛ charges the capacitor through R₁, and R₂ is connected in parallel with C. The capacitor is uncharged when the switch closes at t = 0. Find the capacitor voltage vC at t = 150 ms.
Vs = 30 VR1 = 6.8 kΩR2 = 6.8 kΩC = 33 µFt = 150 ms
vC = V
8.RC & RL transientsHard
Just before the switch closes at t = 0, the capacitor holds 12 V with the polarity shown. Find the capacitor voltage vC at t = 250 ms.
Vs = 24 VR = 2.2 kΩC = 100 µFvC(0) = 12 Vt = 250 ms
vC = V
9.AC impedance & phasorsMedium
A series RLC circuit is connected to a 120 V (rms), 50 Hz supply. Find the phase angle φ of the impedance, in degrees (positive when the current lags the voltage).
V = 120 V (rms)f = 50 HzR = 50 ΩL = 20 mHC = 47 µF
φ = °
10.AC impedance & phasorsHard
A series RLC circuit is connected to a 24 V (rms), 50 Hz supply. Find the resonant frequency f0 of the circuit.
V = 24 V (rms)f = 50 HzR = 60 ΩL = 250 mHC = 47 µF
f0 = Hz
11.AC power & power factorMedium
A single-phase motor takes 24 kW at a power factor of 0.85 lagging from a 400 V supply. Find the reactive power Q it draws.
P = 24 kWpf = 0.85V = 400 V
Q = kvar
12.AC power & power factorHard
A 150 kVA single-phase transformer supplies a load of 82 kW at a power factor of 0.7 lagging. How much extra real power ΔP can be added as a resistive (unity power factor) load before the transformer reaches its kVA rating?
Smax = 150 kVAP1 = 82 kWpf1 = 0.7
ΔP = kW
13.Three-phase powerMedium
A balanced three-phase load draws a line current of 60 A from a supply with a line-to-line voltage of 400 V. The power factor is 0.85 lagging. Find the total real power P drawn by the load in kW.
VL = 400 VIL = 60 Acos φ = 0.85
P = kW
14.Three-phase powerHard
A balanced three-phase load takes 60 kW at a power factor of 0.65 lagging from a 480 V (line-to-line), 60 Hz supply. A three-phase capacitor bank in parallel with the load must raise the overall power factor to 0.98 lagging. The real power stays the same. Find the total reactive power QC the capacitor bank must supply, in kvar.
P = 60 kWpf1 = 0.65pf2 = 0.98VL = 480 Vf = 60 Hz
QC = kvar
15.TransformersMedium
A single-phase 150 kVA, 480/240 V transformer operates at its rated load. Treat it as ideal. Find the current IHV in the high-voltage winding.
S = 150 kVAV1 = 480 VV2 = 240 V
IHV = A
16.TransformersHard
A single-phase 250 kVA transformer has a core loss of 2000 W. At rated load and a power factor of 0.8 lagging its efficiency is 98.2%. Find the full-load copper loss Pcu,fl in watts.
S = 250 kVAPcore = 2000 Wpf = 0.8η = 98.2%
Pcu,fl = W
3Solutions
1.Series & parallel resistors
Answer: IR1 = 0.8914 A
Series and parallel resistors: in series the same current flows through each resistor and R = R₁ + R₂ + …. In parallel each resistor has the same voltage and 1/R = 1/R₁ + 1/R₂ + …. A ladder network is reduced one pair at a time until a single equivalent resistance remains.
Combine resistors from the far end
Start at the end farthest from the source and work back towards it. Resistors carrying the same current are in series; resistors across the same two nodes are in parallel.
R3 + R4 = 8 + 3 = 11 Ω
R2 ∥ 11 = 20·11/(20+11) = 7.097 Ω
Req = R1 + 7.097 = 3 + 7.097 = 10.1 Ω
Current from the source
The source sees only Req, so Ohm’s law gives the current it delivers. That current flows through R₁.
IR1 = V1/Req = 9/10.1 = 0.8914 A
Answer
IR1 = 0.8914 A
2.Series & parallel resistors
Answer: IR2 = 0.7975 A
Series and parallel resistors: in series the same current flows through each resistor and R = R₁ + R₂ + …. In parallel each resistor has the same voltage and 1/R = 1/R₁ + 1/R₂ + …. A ladder network is reduced one pair at a time until a single equivalent resistance remains.
Combine resistors from the far end
Start at the end farthest from the source and work back towards it. Resistors carrying the same current are in series; resistors across the same two nodes are in parallel.
R5 + R6 = 2 + 8 = 10 Ω
R4 ∥ 10 = 4.444 Ω
R3 + 4.444 = 29.44 Ω
R2 ∥ 29.44 = 9.938 Ω
Req = R1 + 9.938 = 10 + 9.938 = 19.94 Ω
Current from the source
The source sees only Req, so Ohm’s law gives the current it delivers. That current flows through R₁.
IR1 = V1/Req = 24/19.94 = 1.204 A
Current through R₂
Subtract the drop across R₁ to get the voltage at node A, which is the voltage across R₂.
VA = V1 − IR1·R1 = 24 − 1.204·10 = 11.96 V
IR2 = VA/R2 = 11.96/15 = 0.7975 A
Answer
IR2 = 0.7975 A
3.Nodal analysis
Answer: VB = 8.657 V
Nodal analysis: choose a reference node, label the unknown node voltages, write Kirchhoff’s current law at each unknown node using Ohm’s law (I = ΔV/R), and solve the resulting equations.
Set up the nodes
Ground is the bottom wire. Known node voltages come straight from the sources (V1 = 12 V). Unknowns: VA, VB.
KCL at node A
Currents leaving A through the resistors equal the current pushed into A by sources.
VA/R2 + (VA − V1)/R1 + (VA − VB)/R3 = 0
VA/15 + (VA − 12)/2 + (VA − VB)/10 = 0
0.6667·VA − 0.1·VB = 6
KCL at node B
Currents leaving B through the resistors equal the current pushed into B by sources.
VB/R4 + (VB − VA)/R3 = Is
VB/4 + (VB − VA)/10 = 2
−0.1·VA + 0.35·VB = 2
Solve
Δ = (0.6667)(0.35) − (−0.1)(−0.1) = 0.2233
VA = Δ1/Δ = 2.3/0.2233 = 10.3 V
VB = Δ2/Δ = 1.933/0.2233 = 8.657 V
Answer
VB = 8.657 V
4.Nodal analysis
Answer: VA = 6.082 V
Nodal analysis: choose a reference node, label the unknown node voltages, write Kirchhoff’s current law at each unknown node using Ohm’s law (I = ΔV/R), and solve the resulting equations.
Set up the nodes
Ground is the bottom wire. Known node voltages come straight from the sources (V1 = 6 V, V2 = 12 V). Unknowns: VA, VB.
KCL at node A
Currents leaving A through the resistors equal the current pushed into A by sources.
VA/R3 + (VA − V1)/R1 + (VA − VB)/R2 = 0
VA/15 + (VA − 6)/15 + (VA − VB)/12 = 0
0.2167·VA − 0.08333·VB = 0.4
KCL at node B
Currents leaving B through the resistors equal the current pushed into B by sources.
VB/R5 + (VB − VA)/R2 + (VB − V2)/R4 = Is
VB/6 + (VB − VA)/12 + (VB − 12)/4 = 2
−0.08333·VA + 0.5·VB = 5
Solve
Δ = (0.2167)(0.5) − (−0.08333)(−0.08333) = 0.1014
VA = Δ1/Δ = 0.6167/0.1014 = 6.082 V
VB = Δ2/Δ = 1.117/0.1014 = 11.01 V
Answer
VA = 6.082 V
5.Thévenin & Norton
Answer: Vth = 4.286 V
Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.
Find Rth with every source switched off
Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.
R1 ∥ R2 = 6·15/(6+15) = 4.286 Ω
Rth = (R1 ∥ R2) + R3 = 4.286 + 12 = 16.29 Ω
Find Vth, the open-circuit voltage
With a–b open, no current flows through R₃, so there is no drop across it and V_b = V_A. R₁ and R₂ form a voltage divider.
Vth = V1·R2/(R1+R2) = 6·15/(6+15) = 4.286 V
6.Thévenin & Norton
Answer: Vth = 51 V
Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.
Find Rth with every source switched off
Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.
R1 ∥ R2 = 8·8/(8+8) = 4 Ω
Rth = (R1 ∥ R2) + R3 = 4 + 4 = 8 Ω
Find Vth, the open-circuit voltage
With a–b open, the only path for Iₛ is through R₃ into node A. Find V_A by superposition of V₁ and Iₛ, then add the drop across R₃.
VA = V1·R2/(R1+R2) + Is·(R1∥R2) = 3 + 6·4 = 27 V
Vth = VB = VA + Is·R3 = 27 + 6·4 = 51 V
7.RC & RL transients
Answer: vC = 11.06 V
First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.
Thévenin equivalent seen by the capacitor
Short the source to find Rth; open the capacitor to find the voltage it will settle at.
Rth = R1 ∥ R2 = 6.8·6.8/(6.8 + 6.8) = 3.4 kΩ
vC(∞) = 30·6.8/(6.8 + 6.8) = 15 V
Time constant
τ = Rth·C = 3.4·33 = 112.2 ms
Charging curve
vC(t) = 15·(1 − e−150/112.2) = 11.06 V
Answer
vC = 11.06 V
8.RC & RL transients
Answer: vC = 20.15 V
First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.
Initial value, final value, time constant
The capacitor voltage cannot jump, so it starts at its stored value and heads for the source voltage.
vC(0) = 12 V, vC(∞) = Vs = 24 V
τ = R·C = 2.2 kΩ · 100 µF = 220 ms
vC(t) = 24 + (12 − 24)·e−t/τ
Voltage at the given time
vC(250) = 24 + (−12)·e−250/220 = 20.15 V
Answer
vC = 20.15 V
9.AC impedance & phasors
Answer: φ = −50.86 °
AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.
Reactances
ω = 2πf = 2π·50 = 314.2 rad/s
XL = ωL = 314.2·0.02 = 6.283 Ω
XC = 1/(ωC) = 1/(314.2·47·10⁻⁶) = 67.73 Ω
Impedance
In series the impedances add as complex numbers: Z = R + j(XL − XC).
AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.
Resonance
At resonance the inductive and capacitive reactances cancel: ωL = 1/(ωC). The supply frequency does not matter.
AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.
Angle
φ = arccos(0.85) = 31.79°, tan φ = 0.6197
Reactive power
Q = P·tan φ = 24·0.6197 = 14.87 kvar
Answer
Q = 14.87 kvar
12.AC power & power factor
Answer: ΔP = 42.51 kW
AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.
Reactive power of the existing load
Q1 = 82·tan(arccos 0.7) = 83.66 kvar
Largest total real power
At full rating S = Smax, and Q is unchanged by the resistive load.
P = √(Smax² − Q1²) = √(150² − 83.66²) = 124.5 kW
Extra real power
ΔP = 124.5 − 82 = 42.51 kW
Answer
ΔP = 42.51 kW
13.Three-phase power
Answer: P = 35.33 kW
Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ.
Apparent power
S = √3·VL·IL = √3·400·60 = 41.57 kVA
Real power
P = S·cos φ = 41.57·0.85 = 35.33 kW
Answer
P = 35.33 kW
14.Three-phase power
Answer: QC = 57.96 kvar
Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ. Power factor correction: capacitors supply reactive power locally, QC = P·(tan φ1 − tan φ2). Each of the three capacitors supplies QC/3 = V²·ω·C, where V is the voltage across that capacitor: VL in a Δ bank, VL/√3 in a Y bank.
Reactive power before and after
The real power is unchanged, so each power factor fixes the reactive power: Q = P·tan φ.
Q1 = 60·tan(acos 0.65) = 60·1.169 = 70.15 kvar
Q2 = 60·tan(acos 0.98) = 60·0.2031 = 12.18 kvar
Reactive power from the capacitors
QC = Q1 − Q2 = 57.96 kvar
Answer
QC = 57.96 kvar
15.Transformers
Answer: IHV = 312.5 A
Ideal transformer: the voltages are in the ratio of the turns and the currents in the inverse ratio: V₁/V₂ = N₁/N₂ = a and I₁/I₂ = N₂/N₁ = 1/a, so the power in equals the power out, V₁·I₁ = V₂·I₂. A load impedance Z on the secondary looks like a²·Z from the primary.
Rated current
Both windings carry the same apparent power.
IHV = S/V = 150000/480 = 312.5 A
Answer
IHV = 312.5 A
16.Transformers
Answer: Pcu,fl = 1666 W
Transformer losses: the core loss (hysteresis and eddy currents) depends on the voltage and is the same at any load. The copper loss in the windings goes with the current squared, so at a fraction x of rated load it is x²·Pcu,fl. Efficiency η = Pout/(Pout + Pcore + Pcu), with Pout = x·S·pf. The efficiency is highest at the load where the copper loss equals the core loss.