Find the Thévenin resistance Rth seen from terminals a–b.
V1 = 24 VR1 = 8 ΩR2 = 12 ΩR3 = 4 Ω
Rth = Ω
6.Thévenin & NortonHard
Find the Thévenin voltage Vth seen from terminals a–b.
V1 = 9 VIs = 1 AR1 = 3 ΩR2 = 25 ΩR3 = 6 Ω
Vth = V
7.RC & RL transientsMedium
The inductor carries no current before the switch closes at t = 0. How long after the switch closes does the current reach 95% of its final value? Find t.
Vs = 9 VR = 68 ΩL = 47 mH
t = ms
8.RC & RL transientsHard
The switch across R2 has been open for a long time, so the inductor current is steady. At t = 0 the switch closes and shorts out R2. Find the inductor current i at t = 5 ms.
Vs = 20 VR1 = 5 ΩR2 = 22 ΩL = 33 mHt = 5 ms
i = A
9.AC impedance & phasorsMedium
A series RLC circuit with C = 1 µF must resonate at 200 Hz. Find the inductance L needed.
f0 = 200 HzC = 1 µF
L = mH
10.AC impedance & phasorsHard
A series RLC circuit is driven by a 24 V (rms) source whose frequency is set to the resonant frequency of the circuit. Find the rms voltage VL across the inductor.
V = 24 V (rms)R = 50 ΩL = 10 mHC = 0.47 µF
VL = V
11.AC power & power factorMedium
A single-phase motor takes 6 kW at a power factor of 0.9 lagging from a 240 V supply. Find the line current I.
P = 6 kWpf = 0.9V = 240 V
I = A
12.AC power & power factorHard
A single-phase load takes 25 kW at a power factor of 0.8 lagging from a 230 V, 50 Hz supply. A 470 µF capacitor is connected in parallel with the load. Find the new line current I.
P = 25 kWpf1 = 0.8V = 230 Vf = 50 HzC = 470 µF
I = A
13.Three-phase powerMedium
A three-phase induction motor delivers 11 kW of mechanical output power at full load. At this load its efficiency is 94% and its power factor is 0.84 lagging. The supply has a line-to-line voltage of 690 V. Find the line current IL.
Pout = 11 kWη = 94%cos φ = 0.84VL = 690 V
IL = A
14.Three-phase powerHard
A balanced three-phase load takes 250 kW at a power factor of 0.8 lagging from a 400 V (line-to-line), 60 Hz supply. A three-phase capacitor bank in parallel with the load must raise the overall power factor to 0.92 lagging. The real power stays the same. The capacitors are connected in Δ. Find the capacitance Cph of each capacitor in µF.
P = 250 kWpf1 = 0.8pf2 = 0.92VL = 400 Vf = 60 Hz
Cph = µF
15.TransformersMedium
A single-phase 150 kVA, 2400/240 V transformer operates at its rated load. Treat it as ideal. Find the current ILV in the low-voltage winding.
S = 150 kVAV1 = 2400 VV2 = 240 V
ILV = A
16.TransformersHard
A single-phase 25 kVA transformer has a core loss of 150 W and a copper loss of 600 W at rated load. At what load Sη,max, in kVA, is its efficiency highest?
S = 25 kVAPcore = 150 WPcu,fl = 600 W
Sη,max = kVA
3Solutions
1.Series & parallel resistors
Answer: Req = 25.09 Ω
Series and parallel resistors: in series the same current flows through each resistor and R = R₁ + R₂ + …. In parallel each resistor has the same voltage and 1/R = 1/R₁ + 1/R₂ + …. A ladder network is reduced one pair at a time until a single equivalent resistance remains.
Combine resistors from the far end
Start at the end farthest from the source and work back towards it. Resistors carrying the same current are in series; resistors across the same two nodes are in parallel.
R3 + R4 = 6 + 8 = 14 Ω
R2 ∥ 14 = 8·14/(8+14) = 5.091 Ω
Req = R1 + 5.091 = 20 + 5.091 = 25.09 Ω
Answer
Req = 25.09 Ω
2.Series & parallel resistors
Answer: Req = 13.29 Ω
Series and parallel resistors: in series the same current flows through each resistor and R = R₁ + R₂ + …. In parallel each resistor has the same voltage and 1/R = 1/R₁ + 1/R₂ + …. A ladder network is reduced one pair at a time until a single equivalent resistance remains.
Combine resistors from the far end
Start at the end farthest from the source and work back towards it. Resistors carrying the same current are in series; resistors across the same two nodes are in parallel.
R5 + R6 = 25 + 5 = 30 Ω
R4 ∥ 30 = 8.571 Ω
R3 + 8.571 = 18.57 Ω
R2 ∥ 18.57 = 7.29 Ω
Req = R1 + 7.29 = 6 + 7.29 = 13.29 Ω
Answer
Req = 13.29 Ω
3.Nodal analysis
Answer: PIs = 117.5 W
Nodal analysis: choose a reference node, label the unknown node voltages, write Kirchhoff’s current law at each unknown node using Ohm’s law (I = ΔV/R), and solve the resulting equations.
KCL at node A
Currents leaving A through the resistors equal the current pushed into A by sources.
VA/R2 + (VA − V1)/R1 + (VA − VB)/R3 = 0
VA/10 + (VA − 30)/4 + (VA − VB)/4 = 0
0.6·VA − 0.25·VB = 7.5
KCL at node B
Currents leaving B through the resistors equal the current pushed into B by sources.
VB/R4 + (VB − VA)/R3 = Is
VB/5 + (VB − VA)/4 = 5
−0.25·VA + 0.45·VB = 5
Solve
Δ = (0.6)(0.45) − (−0.25)(−0.25) = 0.2075
VA = Δ1/Δ = 4.625/0.2075 = 22.29 V
VB = Δ2/Δ = 4.875/0.2075 = 23.49 V
Power delivered by the current source
The source pushes Iₛ up into node B, from ground (0 V) to VB. A source whose current leaves its + end delivers P = V·I.
PIs = VB·Is = 23.49·5 = 117.5 W
Answer
PIs = 117.5 W
4.Nodal analysis
Answer: Is = 3.773 A
Nodal analysis: choose a reference node, label the unknown node voltages, write Kirchhoff’s current law at each unknown node using Ohm’s law (I = ΔV/R), and solve the resulting equations.
KCL at node A
VA is known, so this equation gives VB.
(VA − V1)/R1 + VA/R2 + (VA − VB)/R3 = 0
(11 − 30)/12 + 11/3 = (VB − 11)/15
2.083 = (VB − 11)/15 → VB = 42.25 V
KCL at node B
Currents leaving B through the resistors equal the current pushed into B by sources.
Is = (VB − VA)/R3 + VB/R4 = (42.25 − 11)/15 + 42.25/25 = 3.773 A
Answer
Is = 3.773 A
5.Thévenin & Norton
Answer: Rth = 8.8 Ω
Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.
Find Rth with every source switched off
Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.
R1 ∥ R2 = 8·12/(8+12) = 4.8 Ω
Rth = (R1 ∥ R2) + R3 = 4.8 + 4 = 8.8 Ω
6.Thévenin & Norton
Answer: Vth = 16.71 V
Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.
Find Rth with every source switched off
Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.
R1 ∥ R2 = 3·25/(3+25) = 2.679 Ω
Rth = (R1 ∥ R2) + R3 = 2.679 + 6 = 8.679 Ω
Find Vth, the open-circuit voltage
With a–b open, the only path for Iₛ is through R₃ into node A. Find V_A by superposition of V₁ and Iₛ, then add the drop across R₃.
VA = V1·R2/(R1+R2) + Is·(R1∥R2) = 8.036 + 1·2.679 = 10.71 V
Vth = VB = VA + Is·R3 = 10.71 + 1·6 = 16.71 V
7.RC & RL transients
Answer: t = 2.071 ms
First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.
Time constant and final current
Long after the switch closes the inductor behaves like a short circuit, so the final current is set by R alone.
τ = L/R = 47 mH / 68 Ω = 0.6912 ms
i(∞) = Vs/R = 9/68 = 0.1324 A
Solve for the time
0.95 = 1 − e−t/τ → t = −τ·ln(1 − 0.95)
t = −0.6912·ln(0.05) = 2.071 ms
Answer
t = 2.071 ms
8.RC & RL transients
Answer: i = 2.472 A
First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.
Initial value, final value, time constant
Before t = 0 both resistors are in the loop; afterwards the closed switch bypasses R₂.
i(0) = 20/(5 + 22) = 0.7407 A
i(∞) = 20/5 = 4 A
τ = L/R = 33/5 = 6.6 ms
i(t) = 4 + (0.7407 − 4)·e−t/τ
Current at the given time
i(5) = 4 + (−3.259)·e−5/6.6 = 2.472 A
Answer
i = 2.472 A
9.AC impedance & phasors
Answer: L = 633.3 mH
AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.
Resonance condition
At resonance the inductive and capacitive reactances cancel: ωL = 1/(ωC).
ω₀ = 2π·200 = 1257 rad/s
L = 1/(ω₀²·C) = 1/(1257²·1·10⁻⁶) = 633.3 mH
Answer
L = 633.3 mH
10.AC impedance & phasors
Answer: VL = 70.02 V
AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.
Resonance
At resonance the reactances cancel, so the impedance is just R.
ω₀ = 1/√(LC) = 1/√(0.01·0.47·10⁻⁶) = 14586 rad/s
I = V/R = 24/50 = 0.48 A
Voltage across the inductor
XL = ω₀L = 14586·0.01 = 145.9 Ω
VL = I·XL = 0.48·145.9 = 70.02 V
Answer
VL = 70.02 V
This is Q = 2.917 times the supply voltage.
11.AC power & power factor
Answer: I = 27.78 A
AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.
Line current
Only the real part of the power does work, so divide by the power factor.
I = P/(V·cos φ) = 6000/(240·0.9) = 27.78 A
Answer
I = 27.78 A
12.AC power & power factor
Answer: I = 118.6 A
AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.
Reactive power before and after
The real power P does not change; only the reactive power drawn from the supply does.
Q1 = 25·tan(arccos 0.8) = 18.75 kvar
QC = V²·2πf·C = 230²·2π·50·470·10⁻⁶ = 7811 var = 7.811 kvar
Q2 = 18.75 − 7.811 = 10.94 kvar
New apparent power
S2 = √(25² + 10.94²) = 27.29 kVA
New line current
I = S2/V = 27289/230 = 118.6 A
Answer
I = 118.6 A
13.Three-phase power
Answer: IL = 11.66 A
Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ.
Electrical input power
Pin = Pout/η = 11/0.94 = 11.7 kW
Line current
IL = Pin/(√3·VL·cos φ) = 11702/(√3·690·0.84) = 11.66 A
Answer
IL = 11.66 A
14.Three-phase power
Answer: Cph = 447.6 µF
Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ. Power factor correction: capacitors supply reactive power locally, QC = P·(tan φ1 − tan φ2). Each of the three capacitors supplies QC/3 = V²·ω·C, where V is the voltage across that capacitor: VL in a Δ bank, VL/√3 in a Y bank.
Reactive power before and after
The real power is unchanged, so each power factor fixes the reactive power: Q = P·tan φ.
Q1 = 250·tan(acos 0.8) = 250·0.75 = 187.5 kvar
Q2 = 250·tan(acos 0.92) = 250·0.426 = 106.5 kvar
Reactive power from the capacitors
QC = Q1 − Q2 = 81 kvar
Capacitance per phase
In a Δ bank each capacitor is connected between two lines.
V = 400 V, ω = 2π·60 = 377 rad/s
Cph = (QC/3)/(ω·V²) = 27000/(377·400²) = 447.6 µF
Answer
Cph = 447.6 µF
15.Transformers
Answer: ILV = 625 A
Ideal transformer: the voltages are in the ratio of the turns and the currents in the inverse ratio: V₁/V₂ = N₁/N₂ = a and I₁/I₂ = N₂/N₁ = 1/a, so the power in equals the power out, V₁·I₁ = V₂·I₂. A load impedance Z on the secondary looks like a²·Z from the primary.
Rated current
Both windings carry the same apparent power.
ILV = S/V = 150000/240 = 625 A
Answer
ILV = 625 A
16.Transformers
Answer: Sη,max = 12.5 kVA
Transformer losses: the core loss (hysteresis and eddy currents) depends on the voltage and is the same at any load. The copper loss in the windings goes with the current squared, so at a fraction x of rated load it is x²·Pcu,fl. Efficiency η = Pout/(Pout + Pcore + Pcu), with Pout = x·S·pf. The efficiency is highest at the load where the copper loss equals the core loss.