Find the Thévenin voltage Vth seen from terminals a–b.
V1 = 15 VR1 = 15 ΩR2 = 12 ΩR3 = 6 Ω
Vth = V
6.Thévenin & NortonHard
Find the Thévenin voltage Vth seen from terminals a–b.
V1 = 18 VIs = 5 AR1 = 30 ΩR2 = 4 ΩR3 = 6 Ω
Vth = V
7.RC & RL transientsMedium
The inductor carries no current before the switch closes at t = 0. Find the energy W stored in the inductor at t = 5 ms, in mJ.
Vs = 24 VR = 20 ΩL = 47 mHt = 5 ms
W = mJ
8.RC & RL transientsHard
Just before the switch closes at t = 0, the capacitor holds 2 V with the polarity shown. How long does it take for vC to reach 8.6 V? Find t.
Vs = 24 VR = 10 kΩC = 47 µFvC(0) = 2 V
t = ms
9.AC impedance & phasorsMedium
A series RLC circuit with L = 20 mH must resonate at 5000 Hz. Find the capacitance C needed.
f0 = 5000 HzL = 20 mH
C = µF
10.AC impedance & phasorsHard
A resistor R1 is connected in series with a parallel combination of R2 and a capacitor C, across a 50 V (rms), 500 Hz supply. Find the rms current I.
V = 50 V (rms)f = 500 HzR1 = 30 ΩR2 = 20 ΩC = 10 µF
I = A
11.AC power & power factorMedium
Two loads are connected in parallel to a 400 V single-phase supply: a 19 kW load at a power factor of 0.7 lagging and a 27 kW load at a power factor of 0.7 leading. Find the total current I drawn from the supply.
V = 400 VP1 = 19 kW, pf1 = 0.7 laggingP2 = 27 kW, pf2 = 0.7 leading
I = A
12.AC power & power factorHard
A single-phase load takes 19 kW at a power factor of 0.8 lagging from a 400 V, 50 Hz supply. A 100 µF capacitor is connected in parallel with the load. Find the new power factor cos φ seen by the supply.
P = 19 kWpf1 = 0.8V = 400 Vf = 50 HzC = 100 µF
cos φ =
13.Three-phase powerMedium
A three-phase induction motor delivers 110 kW of mechanical output power at full load. At this load its efficiency is 94% and its power factor is 0.84 lagging. The supply has a line-to-line voltage of 415 V. Find the line current IL.
Pout = 110 kWη = 94%cos φ = 0.84VL = 415 V
IL = A
14.Three-phase powerHard
A balanced three-phase load takes 100 kW at a power factor of 0.7 lagging from a 400 V (line-to-line), 50 Hz supply. A three-phase capacitor bank in parallel with the load must raise the overall power factor to 0.95 lagging. The real power stays the same. Find the total reactive power QC the capacitor bank must supply, in kvar.
P = 100 kWpf1 = 0.7pf2 = 0.95VL = 400 Vf = 50 Hz
QC = kvar
15.TransformersMedium
A single-phase 150 kVA, 480/240 V transformer operates at its rated load. Treat it as ideal. Find the current IHV in the high-voltage winding.
S = 150 kVAV1 = 480 VV2 = 240 V
IHV = A
16.TransformersHard
A single-phase 25 kVA transformer has a core loss of 125 W and a copper loss of 250 W at rated load. At what load Sη,max, in kVA, is its efficiency highest?
S = 25 kVAPcore = 125 WPcu,fl = 250 W
Sη,max = kVA
3Solutions
1.Series & parallel resistors
Answer: IR1 = 1.731 A
Series and parallel resistors: in series the same current flows through each resistor and R = R₁ + R₂ + …. In parallel each resistor has the same voltage and 1/R = 1/R₁ + 1/R₂ + …. A ladder network is reduced one pair at a time until a single equivalent resistance remains.
Combine resistors from the far end
Start at the end farthest from the source and work back towards it. Resistors carrying the same current are in series; resistors across the same two nodes are in parallel.
R3 + R4 = 20 + 4 = 24 Ω
R2 ∥ 24 = 3·24/(3+24) = 2.667 Ω
Req = R1 + 2.667 = 6 + 2.667 = 8.667 Ω
Current from the source
The source sees only Req, so Ohm’s law gives the current it delivers. That current flows through R₁.
IR1 = V1/Req = 15/8.667 = 1.731 A
Answer
IR1 = 1.731 A
2.Series & parallel resistors
Answer: Req = 32.94 Ω
Series and parallel resistors: in series the same current flows through each resistor and R = R₁ + R₂ + …. In parallel each resistor has the same voltage and 1/R = 1/R₁ + 1/R₂ + …. A ladder network is reduced one pair at a time until a single equivalent resistance remains.
Combine resistors from the far end
Start at the end farthest from the source and work back towards it. Resistors carrying the same current are in series; resistors across the same two nodes are in parallel.
R5 + R6 = 8 + 6 = 14 Ω
R4 ∥ 14 = 3.111 Ω
R3 + 3.111 = 7.111 Ω
R2 ∥ 7.111 = 2.936 Ω
Req = R1 + 2.936 = 30 + 2.936 = 32.94 Ω
Answer
Req = 32.94 Ω
3.Nodal analysis
Answer: VA = 16.36 V
Nodal analysis: choose a reference node, label the unknown node voltages, write Kirchhoff’s current law at each unknown node using Ohm’s law (I = ΔV/R), and solve the resulting equations.
Set up the nodes
Ground is the bottom wire. Known node voltages come straight from the sources (V1 = 9 V). Unknowns: VA, VB.
KCL at node A
Currents leaving A through the resistors equal the current pushed into A by sources.
VA/R2 + (VA − V1)/R1 + (VA − VB)/R3 = 0
VA/12 + (VA − 9)/12 + (VA − VB)/4 = 0
0.4167·VA − 0.25·VB = 0.75
KCL at node B
Currents leaving B through the resistors equal the current pushed into B by sources.
VB/R4 + (VB − VA)/R3 = Is
VB/12 + (VB − VA)/4 = 4
−0.25·VA + 0.3333·VB = 4
Solve
Δ = (0.4167)(0.3333) − (−0.25)(−0.25) = 0.07639
VA = Δ1/Δ = 1.25/0.07639 = 16.36 V
VB = Δ2/Δ = 1.854/0.07639 = 24.27 V
Answer
VA = 16.36 V
4.Nodal analysis
Answer: VA = 12.79 V
Nodal analysis: choose a reference node, label the unknown node voltages, write Kirchhoff’s current law at each unknown node using Ohm’s law (I = ΔV/R), and solve the resulting equations.
Set up the nodes
Ground is the bottom wire. Known node voltages come straight from the sources (V1 = 24 V, V2 = −10 V). Unknowns: VA, VB.
KCL at node A
Currents leaving A through the resistors equal the current pushed into A by sources.
VA/R3 + (VA − V1)/R1 + (VA − VB)/R2 = 0
VA/6 + (VA − 24)/4 + (VA − VB)/30 = 0
0.45·VA − 0.03333·VB = 6
KCL at node B
Currents leaving B through the resistors equal the current pushed into B by sources.
Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.
Find Rth with every source switched off
Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.
R1 ∥ R2 = 15·12/(15+12) = 6.667 Ω
Rth = (R1 ∥ R2) + R3 = 6.667 + 6 = 12.67 Ω
Find Vth, the open-circuit voltage
With a–b open, no current flows through R₃, so there is no drop across it and V_b = V_A. R₁ and R₂ form a voltage divider.
Vth = V1·R2/(R1+R2) = 15·12/(15+12) = 6.667 V
6.Thévenin & Norton
Answer: Vth = 49.76 V
Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.
Find Rth with every source switched off
Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.
R1 ∥ R2 = 30·4/(30+4) = 3.529 Ω
Rth = (R1 ∥ R2) + R3 = 3.529 + 6 = 9.529 Ω
Find Vth, the open-circuit voltage
With a–b open, the only path for Iₛ is through R₃ into node A. Find V_A by superposition of V₁ and Iₛ, then add the drop across R₃.
VA = V1·R2/(R1+R2) + Is·(R1∥R2) = 2.118 + 5·3.529 = 19.76 V
Vth = VB = VA + Is·R3 = 19.76 + 5·6 = 49.76 V
7.RC & RL transients
Answer: W = 26.26 mJ
First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.
Time constant and final current
Long after the switch closes the inductor behaves like a short circuit, so the final current is set by R alone.
τ = L/R = 47 mH / 20 Ω = 2.35 ms
i(∞) = Vs/R = 24/20 = 1.2 A
Current at the given time
i(t) = 1.2·(1 − e−5/2.35) = 1.057 A
Stored energy
W = ½·L·i² = ½·47·1.057² = 26.26 mJ
Answer
W = 26.26 mJ
8.RC & RL transients
Answer: t = 167.6 ms
First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.
Initial value, final value, time constant
The capacitor voltage cannot jump, so it starts at its stored value and heads for the source voltage.
t = τ·ln((2 − 24)/(8.6 − 24)) = 470·ln(1.429) = 167.6 ms
Answer
t = 167.6 ms
9.AC impedance & phasors
Answer: C = 0.05066 µF
AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.
Resonance condition
At resonance the inductive and capacitive reactances cancel: ωL = 1/(ωC).
ω₀ = 2π·5000 = 31416 rad/s
C = 1/(ω₀²·L) = 1/(31416²·0.02) = 0.05066 µF
Answer
C = 0.05066 µF
10.AC impedance & phasors
Answer: I = 1.105 A
AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.
Reactance
XC = 1/(2π·500·10·10⁻⁶) = 31.83 Ω
Parallel combination
Multiply top and bottom by the complex conjugate to split Zp into real and imaginary parts.
AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.
Reactive power of each load
A lagging load takes reactive power (Q > 0); a leading load supplies it (Q < 0).
Q1 = 19·tan(arccos 0.7) = 19.38 kvar
Q2 = −27·tan(arccos 0.7) = −27.55 kvar
Totals
P = 19 + 27 = 46 kW
Q = 19.38 + (−27.55) = −8.162 kvar
S = √(46² + (−8.162)²) = 46.72 kVA
Total current
I = S/V = 46718/400 = 116.8 A
Answer
I = 116.8 A
12.AC power & power factor
Answer: cos φ = 0.8996
AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.
Reactive power before and after
The real power P does not change; only the reactive power drawn from the supply does.
Q1 = 19·tan(arccos 0.8) = 14.25 kvar
QC = V²·2πf·C = 400²·2π·50·100·10⁻⁶ = 5027 var = 5.027 kvar
Q2 = 14.25 − 5.027 = 9.223 kvar
New apparent power
S2 = √(19² + 9.223²) = 21.12 kVA
New power factor
cos φ = P/S2 = 19/21.12 = 0.8996
Answer
cos φ = 0.8996
13.Three-phase power
Answer: IL = 193.8 A
Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ.
Electrical input power
Pin = Pout/η = 110/0.94 = 117 kW
Line current
IL = Pin/(√3·VL·cos φ) = 117021/(√3·415·0.84) = 193.8 A
Answer
IL = 193.8 A
14.Three-phase power
Answer: QC = 69.15 kvar
Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ. Power factor correction: capacitors supply reactive power locally, QC = P·(tan φ1 − tan φ2). Each of the three capacitors supplies QC/3 = V²·ω·C, where V is the voltage across that capacitor: VL in a Δ bank, VL/√3 in a Y bank.
Reactive power before and after
The real power is unchanged, so each power factor fixes the reactive power: Q = P·tan φ.
Q1 = 100·tan(acos 0.7) = 100·1.02 = 102 kvar
Q2 = 100·tan(acos 0.95) = 100·0.3287 = 32.87 kvar
Reactive power from the capacitors
QC = Q1 − Q2 = 69.15 kvar
Answer
QC = 69.15 kvar
15.Transformers
Answer: IHV = 312.5 A
Ideal transformer: the voltages are in the ratio of the turns and the currents in the inverse ratio: V₁/V₂ = N₁/N₂ = a and I₁/I₂ = N₂/N₁ = 1/a, so the power in equals the power out, V₁·I₁ = V₂·I₂. A load impedance Z on the secondary looks like a²·Z from the primary.
Rated current
Both windings carry the same apparent power.
IHV = S/V = 150000/480 = 312.5 A
Answer
IHV = 312.5 A
16.Transformers
Answer: Sη,max = 17.68 kVA
Transformer losses: the core loss (hysteresis and eddy currents) depends on the voltage and is the same at any load. The copper loss in the windings goes with the current squared, so at a fraction x of rated load it is x²·Pcu,fl. Efficiency η = Pout/(Pout + Pcore + Pcu), with Pout = x·S·pf. The efficiency is highest at the load where the copper loss equals the core loss.