The voltage source Vₛ between A and B has its + terminal at B, so it makes VB − VA = Vₛ. Use nodal analysis with a supernode to find the node voltage VB (measured from ground).
Is = 1 AVs = 4 VR1 = 8 ΩR2 = 5 Ω
VB = V
4.Nodal analysisHard
Use nodal analysis to find the current IR1 through R1 in the direction of the arrow.
A load RL = 12 Ω is connected across a–b. Replace the rest of the circuit with its Thévenin equivalent and find the load current IL.
V1 = 18 VR1 = 3 ΩR2 = 15 ΩR3 = 4 ΩRL = 12 Ω
IL = A
6.Thévenin & NortonHard
Find the Norton current IN: the current that flows from a to b if the terminals are shorted.
V1 = 10 VIs = 1.5 AR1 = 2 ΩR2 = 8 ΩR3 = 20 Ω
IN = A
7.RC & RL transientsMedium
The inductor carries no current before the switch closes at t = 0. Find the voltage vL across the inductor at t = 2 ms.
Vs = 12 VR = 22 ΩL = 33 mHt = 2 ms
vL = V
8.RC & RL transientsHard
The switch across R2 has been open for a long time, so the inductor current is steady. At t = 0 the switch closes and shorts out R2. How long after t = 0 does the inductor current reach 0.32 A? Find t.
Vs = 6 VR1 = 15 ΩR2 = 15 ΩL = 47 mH
t = ms
9.AC impedance & phasorsMedium
A series RLC circuit is connected to a 120 V (rms), 1000 Hz supply. Find the rms current I.
V = 120 V (rms)f = 1000 HzR = 100 ΩL = 50 mHC = 22 µF
I = A
10.AC impedance & phasorsHard
A series RLC circuit is driven by a 1 V (rms) source whose frequency is set to the resonant frequency of the circuit. Find the rms voltage VL across the inductor.
V = 1 V (rms)R = 15 ΩL = 100 mHC = 1 µF
VL = V
11.AC power & power factorMedium
A load with impedance Z = 4 + j3 Ω is connected to a 120 V (rms) single-phase supply. Find the apparent power S.
V = 120 VZ = 4 + j3 Ω
S = VA
12.AC power & power factorHard
A single-phase load takes 5 kW at a power factor of 0.7 lagging from a 400 V, 50 Hz supply. A 22 µF capacitor is connected in parallel with the load. Find the new power factor cos φ seen by the supply.
P = 5 kWpf1 = 0.7V = 400 Vf = 50 HzC = 22 µF
cos φ =
13.Three-phase powerMedium
A balanced three-phase load draws a line current of 120 A from a supply with a line-to-line voltage of 415 V. The power factor is 0.75 lagging. Find the total real power P drawn by the load in kW.
VL = 415 VIL = 120 Acos φ = 0.75
P = kW
14.Three-phase powerHard
A balanced three-phase load takes 200 kW at a power factor of 0.75 lagging from a 400 V (line-to-line), 60 Hz supply. A three-phase capacitor bank in parallel with the load must raise the overall power factor to 0.95 lagging. The real power stays the same. The capacitors are connected in Δ. Find the capacitance Cph of each capacitor in µF.
P = 200 kWpf1 = 0.75pf2 = 0.95VL = 400 Vf = 60 Hz
Cph = µF
15.TransformersMedium
An ideal transformer with a turns ratio N₁:N₂ = 20:1 has 4600 V applied to its primary winding. A 12 Ω resistor is connected across the secondary winding. Find the primary current I1.
N1:N2 = 20:1V1 = 4600 VRL = 12 Ω
I1 = A
16.TransformersHard
A single-phase 250 kVA transformer has a core loss of 1500 W and a copper loss of 2250 W at rated load. At what load Sη,max, in kVA, is its efficiency highest?
S = 250 kVAPcore = 1500 WPcu,fl = 2250 W
Sη,max = kVA
3Solutions
1.Series & parallel resistors
Answer: Req = 27.76 Ω
Series and parallel resistors: in series the same current flows through each resistor and R = R₁ + R₂ + …. In parallel each resistor has the same voltage and 1/R = 1/R₁ + 1/R₂ + …. A ladder network is reduced one pair at a time until a single equivalent resistance remains.
Combine resistors from the far end
Start at the end farthest from the source and work back towards it. Resistors carrying the same current are in series; resistors across the same two nodes are in parallel.
R3 + R4 = 10 + 12 = 22 Ω
R2 ∥ 22 = 12·22/(12+22) = 7.765 Ω
Req = R1 + 7.765 = 20 + 7.765 = 27.76 Ω
Answer
Req = 27.76 Ω
2.Series & parallel resistors
Answer: IR1 = 1.833 A
Series and parallel resistors: in series the same current flows through each resistor and R = R₁ + R₂ + …. In parallel each resistor has the same voltage and 1/R = 1/R₁ + 1/R₂ + …. A ladder network is reduced one pair at a time until a single equivalent resistance remains.
Combine resistors from the far end
Start at the end farthest from the source and work back towards it. Resistors carrying the same current are in series; resistors across the same two nodes are in parallel.
R5 + R6 = 15 + 15 = 30 Ω
R4 ∥ 30 = 5 Ω
R3 + 5 = 30 Ω
R2 ∥ 30 = 13.64 Ω
Req = R1 + 13.64 = 6 + 13.64 = 19.64 Ω
Current from the source
The source sees only Req, so Ohm’s law gives the current it delivers. That current flows through R₁.
IR1 = V1/Req = 36/19.64 = 1.833 A
Answer
IR1 = 1.833 A
3.Nodal analysis
Answer: VB = 4.615 V
Nodal analysis: choose a reference node, label the unknown node voltages, write Kirchhoff’s current law at each unknown node using Ohm’s law (I = ΔV/R), and solve the resulting equations.
Form a supernode
The voltage source between A and B carries an unknown current, so KCL cannot be written at A or B separately. Enclose A, B and the source in one supernode: the current entering it equals the current leaving it.
VB = VA + Vs = VA + 4
VA/R1 + VB/R2 = Is
Solve
VA/8 + (VA + 4)/5 = 1
VA = (1 − 4/5)/(1/8 + 1/5) = 0.6154 V
VB = 0.6154 + 4 = 4.615 V
Answer
VB = 4.615 V
4.Nodal analysis
Answer: IR1 = 1.167 A
Nodal analysis: choose a reference node, label the unknown node voltages, write Kirchhoff’s current law at each unknown node using Ohm’s law (I = ΔV/R), and solve the resulting equations.
Set up the nodes
Ground is the bottom wire. Known node voltages come straight from the sources (V1 = 24 V, V2 = −30 V). Unknowns: VA, VB.
KCL at node A
Currents leaving A through the resistors equal the current pushed into A by sources.
VA/R3 + (VA − V1)/R1 + (VA − VB)/R2 = 0
VA/12 + (VA − 24)/10 + (VA − VB)/10 = 0
0.2833·VA − 0.1·VB = 2.4
KCL at node B
Currents leaving B through the resistors equal the current pushed into B by sources.
VB/R5 + (VB − VA)/R2 + (VB − V2)/R4 = Is
VB/10 + (VB − VA)/10 + (VB − (−30))/20 = 3
−0.1·VA + 0.25·VB = 1.5
Solve
Δ = (0.2833)(0.25) − (−0.1)(−0.1) = 0.06083
VA = Δ1/Δ = 0.75/0.06083 = 12.33 V
VB = Δ2/Δ = 0.665/0.06083 = 10.93 V
Answer
IR1 = (V1 − VA)/R1 = (24 − 12.33)/10 = 1.167 A
5.Thévenin & Norton
Answer: IL = 0.8108 A
Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.
Find Rth with every source switched off
Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.
R1 ∥ R2 = 3·15/(3+15) = 2.5 Ω
Rth = (R1 ∥ R2) + R3 = 2.5 + 4 = 6.5 Ω
Find Vth, the open-circuit voltage
With a–b open, no current flows through R₃, so there is no drop across it and V_b = V_A. R₁ and R₂ form a voltage divider.
Vth = V1·R2/(R1+R2) = 18·15/(3+15) = 15 V
Connect the load to the Thévenin equivalent
The Thévenin source and R_th in series behave exactly like the original circuit at a–b, so the load sees a simple series loop.
IL = Vth/(Rth + RL) = 15/(6.5 + 12) = 0.8108 A
6.Thévenin & Norton
Answer: IN = 1.87 A
Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.
Find Rth with every source switched off
Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.
R1 ∥ R2 = 2·8/(2+8) = 1.6 Ω
Rth = (R1 ∥ R2) + R3 = 1.6 + 20 = 21.6 Ω
Find Vth, the open-circuit voltage
With a–b open, the only path for Iₛ is through R₃ into node A. Find V_A by superposition of V₁ and Iₛ, then add the drop across R₃.
VA = V1·R2/(R1+R2) + Is·(R1∥R2) = 8 + 1.5·1.6 = 10.4 V
Vth = VB = VA + Is·R3 = 10.4 + 1.5·20 = 40.4 V
Norton equivalent
A Norton source is the same circuit seen as a current source in parallel with R_th. Its current is the short-circuit current at a–b.
IN = Vth/Rth = 40.4/21.6 = 1.87 A
7.RC & RL transients
Answer: vL = 3.163 V
First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.
Time constant and final current
Long after the switch closes the inductor behaves like a short circuit, so the final current is set by R alone.
τ = L/R = 33 mH / 22 Ω = 1.5 ms
i(∞) = Vs/R = 12/22 = 0.5455 A
Inductor voltage
At t = 0 the whole supply voltage appears across the inductor; it then decays to zero.
vL(t) = Vs·e−t/τ = 12·e−2/1.5 = 3.163 V
Answer
vL = 3.163 V
8.RC & RL transients
Answer: t = 2.871 ms
First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.
Initial value, final value, time constant
Before t = 0 both resistors are in the loop; afterwards the closed switch bypasses R₂.
i(0) = 6/(15 + 15) = 0.2 A
i(∞) = 6/15 = 0.4 A
τ = L/R = 47/15 = 3.133 ms
i(t) = 0.4 + (0.2 − 0.4)·e−t/τ
Solve for the time
e−t/τ = (0.32 − 0.4)/(0.2 − 0.4) = 0.4
t = 3.133·ln(2.5) = 2.871 ms
Answer
t = 2.871 ms
9.AC impedance & phasors
Answer: I = 0.3717 A
AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.
Reactances
ω = 2πf = 2π·1000 = 6283 rad/s
XL = ωL = 6283·0.05 = 314.2 Ω
XC = 1/(ωC) = 1/(6283·22·10⁻⁶) = 7.234 Ω
Impedance
In series the impedances add as complex numbers: Z = R + j(XL − XC).
The same current flows through every element of a series circuit.
I = V/|Z| = 120/322.8 = 0.3717 A
Answer
I = 0.3717 A
10.AC impedance & phasors
Answer: VL = 21.08 V
AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.
Resonance
At resonance the reactances cancel, so the impedance is just R.
ω₀ = 1/√(LC) = 1/√(0.1·1·10⁻⁶) = 3162 rad/s
I = V/R = 1/15 = 0.06667 A
Voltage across the inductor
XL = ω₀L = 3162·0.1 = 316.2 Ω
VL = I·XL = 0.06667·316.2 = 21.08 V
Answer
VL = 21.08 V
This is Q = 21.08 times the supply voltage.
11.AC power & power factor
Answer: S = 2880 VA
AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.
Current
|Z| = √(4² + 3²) = 5 Ω
I = V/|Z| = 120/5 = 24 A
Apparent power
S = V·I = 120·24 = 2880 VA
Answer
S = 2880 VA
12.AC power & power factor
Answer: cos φ = 0.7812
AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.
Reactive power before and after
The real power P does not change; only the reactive power drawn from the supply does.
Q1 = 5·tan(arccos 0.7) = 5.101 kvar
QC = V²·2πf·C = 400²·2π·50·22·10⁻⁶ = 1106 var = 1.106 kvar
Q2 = 5.101 − 1.106 = 3.995 kvar
New apparent power
S2 = √(5² + 3.995²) = 6.4 kVA
New power factor
cos φ = P/S2 = 5/6.4 = 0.7812
Answer
cos φ = 0.7812
13.Three-phase power
Answer: P = 64.69 kW
Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ.
Apparent power
S = √3·VL·IL = √3·415·120 = 86.26 kVA
Real power
P = S·cos φ = 86.26·0.75 = 64.69 kW
Answer
P = 64.69 kW
14.Three-phase power
Answer: Cph = 611.5 µF
Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ. Power factor correction: capacitors supply reactive power locally, QC = P·(tan φ1 − tan φ2). Each of the three capacitors supplies QC/3 = V²·ω·C, where V is the voltage across that capacitor: VL in a Δ bank, VL/√3 in a Y bank.
Reactive power before and after
The real power is unchanged, so each power factor fixes the reactive power: Q = P·tan φ.
Q1 = 200·tan(acos 0.75) = 200·0.8819 = 176.4 kvar
Q2 = 200·tan(acos 0.95) = 200·0.3287 = 65.74 kvar
Reactive power from the capacitors
QC = Q1 − Q2 = 110.6 kvar
Capacitance per phase
In a Δ bank each capacitor is connected between two lines.
V = 400 V, ω = 2π·60 = 377 rad/s
Cph = (QC/3)/(ω·V²) = 36882/(377·400²) = 611.5 µF
Answer
Cph = 611.5 µF
15.Transformers
Answer: I1 = 0.9583 A
Ideal transformer: the voltages are in the ratio of the turns and the currents in the inverse ratio: V₁/V₂ = N₁/N₂ = a and I₁/I₂ = N₂/N₁ = 1/a, so the power in equals the power out, V₁·I₁ = V₂·I₂. A load impedance Z on the secondary looks like a²·Z from the primary.
Secondary voltage and current
V2 = 4600/20 = 230 V
I2 = 230/12 = 19.17 A
Primary current
An ideal transformer has no losses: V₁·I₁ = V₂·I₂.
I1 = I2/20 = 0.9583 A
Answer
I1 = 0.9583 A
Check: the load seen from the primary is a²·RL = 4800 Ω, and 4600/4800 gives the same current.
16.Transformers
Answer: Sη,max = 204.1 kVA
Transformer losses: the core loss (hysteresis and eddy currents) depends on the voltage and is the same at any load. The copper loss in the windings goes with the current squared, so at a fraction x of rated load it is x²·Pcu,fl. Efficiency η = Pout/(Pout + Pcore + Pcu), with Pout = x·S·pf. The efficiency is highest at the load where the copper loss equals the core loss.