Series & parallel resistors

Resistors in series
Req = R1 + R2 + …
Resistors in parallel
1/Req = 1/R1 + 1/R2 + …
Two in parallel
Req = R1R2 / (R1 + R2)
Ohm's law
V = I·R
Power
P = V·I = I²R = V²/R

Method

  1. Start at the end of the network furthest from the terminals.
  2. Combine resistors in series by adding them, and resistors in parallel with 1/R = 1/R₁ + 1/R₂ + …
  3. Redraw the circuit after each step.
  4. Repeat until one resistor is left between the terminals.

Nodal analysis

Kirchhoff’s current law
ΣIin = ΣIout
Branch current
I = (Va − Vb)/R
Reference node
Vground = 0

Method

  1. Choose a reference node (ground) and label the other node voltages.
  2. Write Kirchhoff’s current law at every unknown node: currents leaving through each branch equal the currents entering.
  3. Express every branch current as (Va − Vb)/R.
  4. Solve the system of equations, then find any current you need.

Thévenin & Norton

Thévenin voltage
Vth = Vopen circuit
Thévenin resistance
Rth: all sources off, seen from a–b
Norton current
IN = Vth/Rth
Load current
IL = Vth/(Rth + RL)
Maximum power transfer
RL = Rth, Pmax = Vth²/(4Rth)

Method

  1. Remove the load and mark the two terminals a and b.
  2. Find the open-circuit voltage between a and b: this is Vth.
  3. Switch off all independent sources and find the resistance seen from a–b: this is Rth.
  4. Put the load back on the equivalent circuit: Vth in series with Rth.
  5. For the Norton equivalent, convert: IN = Vth/Rth, with RN = Rth in parallel.

RC & RL transients

Time constant
τ = RC | τ = L/R
Response
x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ
Capacitor at DC
open circuit; vC cannot jump
Inductor at DC
short circuit; iL cannot jump
Settled
t ≈ 5τ

Method

  1. Find the initial value just after switching: a capacitor voltage and an inductor current cannot jump.
  2. Find the final value long after switching: a capacitor acts as an open circuit, an inductor as a short circuit.
  3. Find the time constant: τ = RC or τ = L/R, using the resistance seen by the capacitor or inductor.
  4. Use x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ.

AC impedance & phasors

Impedances
ZR = R, ZL = jωL, ZC = 1/(jωC)
Angular frequency
ω = 2πf
Magnitude and angle
|Z| = √(R² + X²), φ = atan(X/R)
Phasor Ohm’s law
V = I·Z

Method

  1. Convert the frequency: ω = 2πf.
  2. Find each reactance: XL = ωL and XC = 1/(ωC).
  3. Add impedances like resistors, with Z = R + jX.
  4. Find the magnitude |Z| = √(R² + X²) and the angle φ = atan(X/R), then use Ohm’s law with phasors.

AC power & power factor

Real power
P = V·I·cos φ
Reactive power
Q = V·I·sin φ
Apparent power
S = V·I = √(P² + Q²)
Power factor
pf = cos φ = P/S
Correction capacitor
QC = P(tan φ1 − tan φ2), C = QC/(ωV²)

Three-phase power

Y connection
VL = √3·Vph, IL = Iph
Δ connection
VL = Vph, IL = √3·Iph
Total real power
P = √3·VL·IL·cos φ = 3·Iph²·R
Apparent and reactive power
S = √3·VL·IL, Q = P·tan φ
Correction capacitors
QC = P(tan φ1 − tan φ2), C = QC/(3ωV²)
Voltage across each capacitor
Δ: VL Y: VL/√3
Motor input
Pin = Pout/η

Transformers

Turns ratio
a = N1/N2 = V1/V2
Current ratio
I1/I2 = N2/N1 = 1/a
Rated current
I = S/V
Referred impedance
Z1′ = a²·ZL
Copper loss at part load
Pcu = x²·Pcu,fl
Efficiency
η = x·S·pf/(x·S·pf + Pcore + x²·Pcu,fl)
Maximum efficiency
x = √(Pcore/Pcu,fl)

2Practice problems

1.Series & parallel resistorsMedium
R1​ = 20 ΩR3​ = 10 Ω+−V1​15 VR2​12 ΩAR4​12 ΩB

Find the equivalent resistance Req seen by the source V1.

V1 = 15 VR1 = 20 ΩR2 = 12 ΩR3 = 10 ΩR4 = 12 Ω
Req = Ω
2.Series & parallel resistorsHard
R1​ = 6 ΩIR1​R3​ = 25 ΩR5​ = 15 Ω+−V1​36 VR2​25 ΩAR4​6 ΩBR6​15 Ω

Find the current IR1 delivered by the source, which flows through R1.

V1 = 36 VR1 = 6 ΩR2 = 25 ΩR3 = 25 ΩR4 = 6 ΩR5 = 15 ΩR6 = 15 Ω
IR1 = A
3.Nodal analysisMedium
−+Vs​ = 4 VIs​1 AAR1​8 ΩR2​5 ΩB

The voltage source Vₛ between A and B has its + terminal at B, so it makes VB − VA = Vₛ. Use nodal analysis with a supernode to find the node voltage VB (measured from ground).

Is = 1 AVs = 4 VR1 = 8 ΩR2 = 5 Ω
VB = V
4.Nodal analysisHard
R1​ = 10 ΩIR1​R2​ = 10 ΩR4​ = 20 Ω+−V1​24 VR3​12 ΩAR5​10 ΩBIs​3 A−+V2​30 V

Use nodal analysis to find the current IR1 through R1 in the direction of the arrow.

V1 = 24 VIs = 3 AV2 = 30 VR1 = 10 ΩR2 = 10 ΩR3 = 12 ΩR4 = 20 ΩR5 = 10 Ω
IR1 = A
5.Thévenin & NortonMedium
R1​ = 3 ΩR3​ = 4 Ω+−V1​18 VR2​15 ΩARL​12 ΩIL​B

A load RL = 12 Ω is connected across a–b. Replace the rest of the circuit with its Thévenin equivalent and find the load current IL.

V1 = 18 VR1 = 3 ΩR2 = 15 ΩR3 = 4 ΩRL = 12 Ω
IL = A
6.Thévenin & NortonHard
R1​ = 2 ΩR3​ = 20 Ω+−V1​10 VR2​8 ΩAIs​1.5 ABab

Find the Norton current IN: the current that flows from a to b if the terminals are shorted.

V1 = 10 VIs = 1.5 AR1 = 2 ΩR2 = 8 ΩR3 = 20 Ω
IN = A
7.RC & RL transientsMedium
+−Vs​12 Vt = 0R = 22 ΩL33 mHi(t)

The inductor carries no current before the switch closes at t = 0. Find the voltage vL across the inductor at t = 2 ms.

Vs = 12 VR = 22 ΩL = 33 mHt = 2 ms
vL = V
8.RC & RL transientsHard
+−Vs​6 VR1​ = 15 ΩR2​ = 15 Ωcloses at t = 0L47 mHi(t)

The switch across R2 has been open for a long time, so the inductor current is steady. At t = 0 the switch closes and shorts out R2. How long after t = 0 does the inductor current reach 0.32 A? Find t.

Vs = 6 VR1 = 15 ΩR2 = 15 ΩL = 47 mH
t = ms
9.AC impedance & phasorsMedium
120 V1000 HzR = 100 ΩL = 50 mHC = 22 µFI

A series RLC circuit is connected to a 120 V (rms), 1000 Hz supply. Find the rms current I.

V = 120 V (rms)f = 1000 HzR = 100 ΩL = 50 mHC = 22 µF
I = A
10.AC impedance & phasorsHard
1 Vf0​R = 15 ΩL = 100 mHC = 1 µF

A series RLC circuit is driven by a 1 V (rms) source whose frequency is set to the resonant frequency of the circuit. Find the rms voltage VL across the inductor.

V = 1 V (rms)R = 15 ΩL = 100 mHC = 1 µF
VL = V
11.AC power & power factorMedium
120 VZ4 + j3 ΩI

A load with impedance Z = 4 + j3 Ω is connected to a 120 V (rms) single-phase supply. Find the apparent power S.

V = 120 VZ = 4 + j3 Ω
S = VA
12.AC power & power factorHard
400 V50 Hzload5 kW, 0.7C22 µFI

A single-phase load takes 5 kW at a power factor of 0.7 lagging from a 400 V, 50 Hz supply. A 22 µF capacitor is connected in parallel with the load. Find the new power factor cos φ seen by the supply.

P = 5 kWpf1 = 0.7V = 400 Vf = 50 HzC = 22 µF
cos φ =
13.Three-phase powerMedium
ABCVL​ = 415 VIL​ = 120 Acos φ = 0.75lagging

A balanced three-phase load draws a line current of 120 A from a supply with a line-to-line voltage of 415 V. The power factor is 0.75 lagging. Find the total real power P drawn by the load in kW.

VL = 415 VIL = 120 Acos φ = 0.75
P = kW
14.Three-phase powerHard
P = 200 kWφ1​S1​Q2​QC​

A balanced three-phase load takes 200 kW at a power factor of 0.75 lagging from a 400 V (line-to-line), 60 Hz supply. A three-phase capacitor bank in parallel with the load must raise the overall power factor to 0.95 lagging. The real power stays the same. The capacitors are connected in Δ. Find the capacitance Cph of each capacitor in µF.

P = 200 kWpf1 = 0.75pf2 = 0.95VL = 400 Vf = 60 Hz
Cph = µF
15.TransformersMedium
RL​ = 12 Ω2014600 VV2​I1​ = ?I2​

An ideal transformer with a turns ratio N₁:N₂ = 20:1 has 4600 V applied to its primary winding. A 12 Ω resistor is connected across the secondary winding. Find the primary current I1.

N1:N2 = 20:1V1 = 4600 VRL = 12 Ω
I1 = A
16.TransformersHard
250 kVA

A single-phase 250 kVA transformer has a core loss of 1500 W and a copper loss of 2250 W at rated load. At what load Sη,max, in kVA, is its efficiency highest?

S = 250 kVAPcore = 1500 WPcu,fl = 2250 W
Sη,max = kVA

3Solutions

1.Series & parallel resistors

Answer: Req = 27.76 Ω

Series and parallel resistors: in series the same current flows through each resistor and R = R₁ + R₂ + …. In parallel each resistor has the same voltage and 1/R = 1/R₁ + 1/R₂ + …. A ladder network is reduced one pair at a time until a single equivalent resistance remains.

R1​ = 20 ΩR3​ = 10 Ω+−V1​15 VR2​12 ΩAR4​12 ΩB

Combine resistors from the far end

Start at the end farthest from the source and work back towards it. Resistors carrying the same current are in series; resistors across the same two nodes are in parallel.

R3 + R4 = 10 + 12 = 22 Ω
R2 ∥ 22 = 12·22/(12+22) = 7.765 Ω
Req = R1 + 7.765 = 20 + 7.765 = 27.76 Ω

Answer

Req = 27.76 Ω
2.Series & parallel resistors

Answer: IR1 = 1.833 A

Series and parallel resistors: in series the same current flows through each resistor and R = R₁ + R₂ + …. In parallel each resistor has the same voltage and 1/R = 1/R₁ + 1/R₂ + …. A ladder network is reduced one pair at a time until a single equivalent resistance remains.

R1​ = 6 ΩR3​ = 25 ΩR5​ = 15 Ω+−V1​36 VR2​25 ΩAR4​6 ΩBR6​15 Ω

Combine resistors from the far end

Start at the end farthest from the source and work back towards it. Resistors carrying the same current are in series; resistors across the same two nodes are in parallel.

R5 + R6 = 15 + 15 = 30 Ω
R4 ∥ 30 = 5 Ω
R3 + 5 = 30 Ω
R2 ∥ 30 = 13.64 Ω
Req = R1 + 13.64 = 6 + 13.64 = 19.64 Ω

Current from the source

The source sees only Req, so Ohm’s law gives the current it delivers. That current flows through R₁.

IR1 = V1/Req = 36/19.64 = 1.833 A

Answer

IR1 = 1.833 A
3.Nodal analysis

Answer: VB = 4.615 V

Nodal analysis: choose a reference node, label the unknown node voltages, write Kirchhoff’s current law at each unknown node using Ohm’s law (I = ΔV/R), and solve the resulting equations.

Form a supernode

The voltage source between A and B carries an unknown current, so KCL cannot be written at A or B separately. Enclose A, B and the source in one supernode: the current entering it equals the current leaving it.

VB = VA + Vs = VA + 4
VA/R1 + VB/R2 = Is

Solve

VA/8 + (VA + 4)/5 = 1
VA = (1 − 4/5)/(1/8 + 1/5) = 0.6154 V
VB = 0.6154 + 4 = 4.615 V

Answer

VB = 4.615 V
4.Nodal analysis

Answer: IR1 = 1.167 A

Nodal analysis: choose a reference node, label the unknown node voltages, write Kirchhoff’s current law at each unknown node using Ohm’s law (I = ΔV/R), and solve the resulting equations.

R1​ = 10 ΩR2​ = 10 ΩR4​ = 20 Ω+−V1​24 VR3​12 ΩAR5​10 ΩBIs​3 A−+V2​30 V

Set up the nodes

Ground is the bottom wire. Known node voltages come straight from the sources (V1 = 24 V, V2 = −30 V). Unknowns: VA, VB.

KCL at node A

Currents leaving A through the resistors equal the current pushed into A by sources.

VA/R3 + (VA − V1)/R1 + (VA − VB)/R2 = 0
VA/12 + (VA − 24)/10 + (VA − VB)/10 = 0
0.2833·VA − 0.1·VB = 2.4

KCL at node B

Currents leaving B through the resistors equal the current pushed into B by sources.

VB/R5 + (VB − VA)/R2 + (VB − V2)/R4 = Is
VB/10 + (VB − VA)/10 + (VB − (−30))/20 = 3
−0.1·VA + 0.25·VB = 1.5

Solve

Δ = (0.2833)(0.25) − (−0.1)(−0.1) = 0.06083
VA = Δ1/Δ = 0.75/0.06083 = 12.33 V
VB = Δ2/Δ = 0.665/0.06083 = 10.93 V

Answer

IR1 = (V1 − VA)/R1 = (24 − 12.33)/10 = 1.167 A
5.Thévenin & Norton

Answer: IL = 0.8108 A

Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.

R1​ = 3 ΩR3​ = 4 ΩSHORTR2​15 ΩAabRth​

Find Rth with every source switched off

Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.

R1 ∥ R2 = 3·15/(3+15) = 2.5 Ω
Rth = (R1 ∥ R2) + R3 = 2.5 + 4 = 6.5 Ω
R1​ = 3 ΩR3​ = 4 Ω+−V1​18 VR2​15 ΩAab+−Vth​

Find Vth, the open-circuit voltage

With a–b open, no current flows through R₃, so there is no drop across it and V_b = V_A. R₁ and R₂ form a voltage divider.

Vth = V1·R2/(R1+R2) = 18·15/(3+15) = 15 V
Rth​ = 6.5 Ω+−Vth​15 VRL​12 ΩIL​

Connect the load to the Thévenin equivalent

The Thévenin source and R_th in series behave exactly like the original circuit at a–b, so the load sees a simple series loop.

IL = Vth/(Rth + RL) = 15/(6.5 + 12) = 0.8108 A
6.Thévenin & Norton

Answer: IN = 1.87 A

Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.

R1​ = 2 ΩR3​ = 20 ΩSHORTR2​8 ΩAOPENBabRth​

Find Rth with every source switched off

Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.

R1 ∥ R2 = 2·8/(2+8) = 1.6 Ω
Rth = (R1 ∥ R2) + R3 = 1.6 + 20 = 21.6 Ω
R1​ = 2 ΩR3​ = 20 Ω+−V1​10 VR2​8 ΩAIs​1.5 ABab+−Vth​

Find Vth, the open-circuit voltage

With a–b open, the only path for Iₛ is through R₃ into node A. Find V_A by superposition of V₁ and Iₛ, then add the drop across R₃.

VA = V1·R2/(R1+R2) + Is·(R1∥R2) = 8 + 1.5·1.6 = 10.4 V
Vth = VB = VA + Is·R3 = 10.4 + 1.5·20 = 40.4 V
IN​1.87 ARth​21.6 Ωab

Norton equivalent

A Norton source is the same circuit seen as a current source in parallel with R_th. Its current is the short-circuit current at a–b.

IN = Vth/Rth = 40.4/21.6 = 1.87 A
7.RC & RL transients

Answer: vL = 3.163 V

First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.

Time constant and final current

Long after the switch closes the inductor behaves like a short circuit, so the final current is set by R alone.

τ = L/R = 33 mH / 22 Ω = 1.5 ms
i(∞) = Vs/R = 12/22 = 0.5455 A

Inductor voltage

At t = 0 the whole supply voltage appears across the inductor; it then decays to zero.

vL(t) = Vs·e−t/τ = 12·e−2/1.5 = 3.163 V

Answer

vL = 3.163 V
8.RC & RL transients

Answer: t = 2.871 ms

First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.

Initial value, final value, time constant

Before t = 0 both resistors are in the loop; afterwards the closed switch bypasses R₂.

i(0) = 6/(15 + 15) = 0.2 A
i(∞) = 6/15 = 0.4 A
τ = L/R = 47/15 = 3.133 ms
i(t) = 0.4 + (0.2 − 0.4)·e−t/τ

Solve for the time

e−t/τ = (0.32 − 0.4)/(0.2 − 0.4) = 0.4
t = 3.133·ln(2.5) = 2.871 ms

Answer

t = 2.871 ms
9.AC impedance & phasors

Answer: I = 0.3717 A

AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.

Reactances

ω = 2πf = 2π·1000 = 6283 rad/s
XL = ωL = 6283·0.05 = 314.2 Ω
XC = 1/(ωC) = 1/(6283·22·10⁻⁶) = 7.234 Ω

Impedance

In series the impedances add as complex numbers: Z = R + j(XL − XC).

|Z| = √(R² + (XL − XC)²) = √(100² + (306.9)²) = 322.8 Ω

Current

The same current flows through every element of a series circuit.

I = V/|Z| = 120/322.8 = 0.3717 A

Answer

I = 0.3717 A
10.AC impedance & phasors

Answer: VL = 21.08 V

AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.

Resonance

At resonance the reactances cancel, so the impedance is just R.

ω₀ = 1/√(LC) = 1/√(0.1·1·10⁻⁶) = 3162 rad/s
I = V/R = 1/15 = 0.06667 A

Voltage across the inductor

XL = ω₀L = 3162·0.1 = 316.2 Ω
VL = I·XL = 0.06667·316.2 = 21.08 V

Answer

VL = 21.08 V

This is Q = 21.08 times the supply voltage.

11.AC power & power factor

Answer: S = 2880 VA

AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.

Current

|Z| = √(4² + 3²) = 5 Ω
I = V/|Z| = 120/5 = 24 A

Apparent power

S = V·I = 120·24 = 2880 VA

Answer

S = 2880 VA
12.AC power & power factor

Answer: cos φ = 0.7812

AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.

Reactive power before and after

The real power P does not change; only the reactive power drawn from the supply does.

Q1 = 5·tan(arccos 0.7) = 5.101 kvar
QC = V²·2πf·C = 400²·2π·50·22·10⁻⁶ = 1106 var = 1.106 kvar
Q2 = 5.101 − 1.106 = 3.995 kvar

New apparent power

S2 = √(5² + 3.995²) = 6.4 kVA

New power factor

cos φ = P/S2 = 5/6.4 = 0.7812

Answer

cos φ = 0.7812
13.Three-phase power

Answer: P = 64.69 kW

Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ.

Apparent power

S = √3·VL·IL = √3·415·120 = 86.26 kVA

Real power

P = S·cos φ = 86.26·0.75 = 64.69 kW

Answer

P = 64.69 kW
14.Three-phase power

Answer: Cph = 611.5 µF

Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ. Power factor correction: capacitors supply reactive power locally, QC = P·(tan φ1 − tan φ2). Each of the three capacitors supplies QC/3 = V²·ω·C, where V is the voltage across that capacitor: VL in a Δ bank, VL/√3 in a Y bank.

Reactive power before and after

The real power is unchanged, so each power factor fixes the reactive power: Q = P·tan φ.

Q1 = 200·tan(acos 0.75) = 200·0.8819 = 176.4 kvar
Q2 = 200·tan(acos 0.95) = 200·0.3287 = 65.74 kvar

Reactive power from the capacitors

QC = Q1 − Q2 = 110.6 kvar

Capacitance per phase

In a Δ bank each capacitor is connected between two lines.

V = 400 V, ω = 2π·60 = 377 rad/s
Cph = (QC/3)/(ω·V²) = 36882/(377·400²) = 611.5 µF

Answer

Cph = 611.5 µF
15.Transformers

Answer: I1 = 0.9583 A

Ideal transformer: the voltages are in the ratio of the turns and the currents in the inverse ratio: V₁/V₂ = N₁/N₂ = a and I₁/I₂ = N₂/N₁ = 1/a, so the power in equals the power out, V₁·I₁ = V₂·I₂. A load impedance Z on the secondary looks like a²·Z from the primary.

Secondary voltage and current

V2 = 4600/20 = 230 V
I2 = 230/12 = 19.17 A

Primary current

An ideal transformer has no losses: V₁·I₁ = V₂·I₂.

I1 = I2/20 = 0.9583 A

Answer

I1 = 0.9583 A

Check: the load seen from the primary is a²·RL = 4800 Ω, and 4600/4800 gives the same current.

16.Transformers

Answer: Sη,max = 204.1 kVA

Transformer losses: the core loss (hysteresis and eddy currents) depends on the voltage and is the same at any load. The copper loss in the windings goes with the current squared, so at a fraction x of rated load it is x²·Pcu,fl. Efficiency η = Pout/(Pout + Pcore + Pcu), with Pout = x·S·pf. The efficiency is highest at the load where the copper loss equals the core loss.

Copper loss equals core loss

x²·2250 = 1500 → x = √(1500/2250) = 0.8165

Load at maximum efficiency

Sη,max = x·S = 0.8165·250 = 204.1 kVA

Answer

Sη,max = 204.1 kVA