A load RL = 8 Ω is connected across a–b. Replace the rest of the circuit with its Thévenin equivalent and find the load current IL.
V1 = 12 VR1 = 12 ΩR2 = 15 ΩR3 = 8 ΩRL = 8 Ω
IL = A
6.Thévenin & NortonHard
Find the Thévenin voltage Vth seen from terminals a–b.
V1 = 9 VIs = 5 AR1 = 12 ΩR2 = 5 ΩR3 = 4 Ω
Vth = V
7.RC & RL transientsMedium
The inductor carries no current before the switch closes at t = 0. Find the energy W(∞) stored in the inductor once the circuit has settled, in mJ.
Vs = 12 VR = 50 ΩL = 33 mH
W(∞) = mJ
8.RC & RL transientsHard
Just before the switch closes at t = 0, the capacitor holds 18 V with the polarity shown. How long does it take for vC to reach 16.2 V? Find t.
Vs = 12 VR = 1 kΩC = 220 µFvC(0) = 18 V
t = ms
9.AC impedance & phasorsMedium
A series RLC circuit is connected to a 230 V (rms), 60 Hz supply. Find the power factor cos φ of the circuit.
V = 230 V (rms)f = 60 HzR = 30 ΩL = 150 mHC = 10 µF
cos φ =
10.AC impedance & phasorsHard
A series RLC circuit has R = 5 Ω, L = 100 mH and C = 0.47 µF. Find its bandwidth B (the width of the band between the half-power frequencies), in Hz.
R = 5 ΩL = 100 mHC = 0.47 µF
B = Hz
11.AC power & power factorMedium
A single-phase motor takes 6 kW at a power factor of 0.85 lagging from a 230 V supply. Find the line current I.
P = 6 kWpf = 0.85V = 230 V
I = A
12.AC power & power factorHard
A single-phase load takes 35 kW at a power factor of 0.7 lagging from a 240 V, 60 Hz supply. A capacitor connected in parallel raises the power factor to 0.95. Find the new line current Inew.
P = 35 kWpf1 = 0.7pf2 = 0.95V = 240 Vf = 60 Hz
Inew = A
13.Three-phase powerMedium
A three-phase induction motor delivers 75 kW of mechanical output power at full load. At this load its efficiency is 88% and its power factor is 0.8 lagging. The supply has a line-to-line voltage of 415 V. Find the line current IL.
Pout = 75 kWη = 88%cos φ = 0.8VL = 415 V
IL = A
14.Three-phase powerHard
A balanced three-phase load takes 200 kW at a power factor of 0.7 lagging from a 480 V (line-to-line), 60 Hz supply. A three-phase capacitor bank in parallel with the load must raise the overall power factor to 0.92 lagging. The real power stays the same. The capacitors are connected in Δ. Find the capacitance Cph of each capacitor in µF.
P = 200 kWpf1 = 0.7pf2 = 0.92VL = 480 Vf = 60 Hz
Cph = µF
15.TransformersMedium
An ideal transformer with a turns ratio N₁:N₂ = 5:1 has 600 V applied to its primary winding. A 30 Ω resistor is connected across the secondary winding. Find the primary current I1.
N1:N2 = 5:1V1 = 600 VRL = 30 Ω
I1 = A
16.TransformersHard
A single-phase 75 kVA transformer has a core loss of 600 W and a copper loss of 1800 W at rated load. At what load Sη,max, in kVA, is its efficiency highest?
S = 75 kVAPcore = 600 WPcu,fl = 1800 W
Sη,max = kVA
3Solutions
1.Series & parallel resistors
Answer: IR1 = 1.125 A
Series and parallel resistors: in series the same current flows through each resistor and R = R₁ + R₂ + …. In parallel each resistor has the same voltage and 1/R = 1/R₁ + 1/R₂ + …. A ladder network is reduced one pair at a time until a single equivalent resistance remains.
Combine resistors from the far end
Start at the end farthest from the source and work back towards it. Resistors carrying the same current are in series; resistors across the same two nodes are in parallel.
R3 + R4 = 10 + 2 = 12 Ω
R2 ∥ 12 = 15·12/(15+12) = 6.667 Ω
Req = R1 + 6.667 = 20 + 6.667 = 26.67 Ω
Current from the source
The source sees only Req, so Ohm’s law gives the current it delivers. That current flows through R₁.
IR1 = V1/Req = 30/26.67 = 1.125 A
Answer
IR1 = 1.125 A
2.Series & parallel resistors
Answer: IR1 = 3.301 A
Series and parallel resistors: in series the same current flows through each resistor and R = R₁ + R₂ + …. In parallel each resistor has the same voltage and 1/R = 1/R₁ + 1/R₂ + …. A ladder network is reduced one pair at a time until a single equivalent resistance remains.
Combine resistors from the far end
Start at the end farthest from the source and work back towards it. Resistors carrying the same current are in series; resistors across the same two nodes are in parallel.
R5 + R6 = 25 + 12 = 37 Ω
R4 ∥ 37 = 5.163 Ω
R3 + 5.163 = 9.163 Ω
R2 ∥ 9.163 = 4.271 Ω
Req = R1 + 4.271 = 3 + 4.271 = 7.271 Ω
Current from the source
The source sees only Req, so Ohm’s law gives the current it delivers. That current flows through R₁.
IR1 = V1/Req = 24/7.271 = 3.301 A
Answer
IR1 = 3.301 A
3.Nodal analysis
Answer: VA = 5.263 V
Nodal analysis: choose a reference node, label the unknown node voltages, write Kirchhoff’s current law at each unknown node using Ohm’s law (I = ΔV/R), and solve the resulting equations.
Set up the nodes
Ground is the bottom wire. Known node voltages come straight from the sources (V1 = 10 V). Unknowns: VA, VB.
KCL at node A
Currents leaving A through the resistors equal the current pushed into A by sources.
VA/R2 + (VA − V1)/R1 + (VA − VB)/R3 = 0
VA/20 + (VA − 10)/10 + (VA − VB)/2 = 0
0.65·VA − 0.5·VB = 1
KCL at node B
Currents leaving B through the resistors equal the current pushed into B by sources.
VB/R4 + (VB − VA)/R3 = Is
VB/4 + (VB − VA)/2 = 1
−0.5·VA + 0.75·VB = 1
Solve
Δ = (0.65)(0.75) − (−0.5)(−0.5) = 0.2375
VA = Δ1/Δ = 1.25/0.2375 = 5.263 V
VB = Δ2/Δ = 1.15/0.2375 = 4.842 V
Answer
VA = 5.263 V
4.Nodal analysis
Answer: IR1 = −0.203 A
Nodal analysis: choose a reference node, label the unknown node voltages, write Kirchhoff’s current law at each unknown node using Ohm’s law (I = ΔV/R), and solve the resulting equations.
Set up the nodes
Ground is the bottom wire. Known node voltages come straight from the sources (V1 = 6 V, V2 = 12 V). Unknowns: VA, VB.
KCL at node A
Currents leaving A through the resistors equal the current pushed into A by sources.
VA/R3 + (VA − V1)/R1 + (VA − VB)/R2 = 0
VA/25 + (VA − 6)/20 + (VA − VB)/6 = 0
0.2567·VA − 0.1667·VB = 0.3
KCL at node B
Currents leaving B through the resistors equal the current pushed into B by sources.
Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.
Find Rth with every source switched off
Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.
R1 ∥ R2 = 12·15/(12+15) = 6.667 Ω
Rth = (R1 ∥ R2) + R3 = 6.667 + 8 = 14.67 Ω
Find Vth, the open-circuit voltage
With a–b open, no current flows through R₃, so there is no drop across it and V_b = V_A. R₁ and R₂ form a voltage divider.
Vth = V1·R2/(R1+R2) = 12·15/(12+15) = 6.667 V
Connect the load to the Thévenin equivalent
The Thévenin source and R_th in series behave exactly like the original circuit at a–b, so the load sees a simple series loop.
IL = Vth/(Rth + RL) = 6.667/(14.67 + 8) = 0.2941 A
6.Thévenin & Norton
Answer: Vth = −35 V
Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.
Find Rth with every source switched off
Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.
R1 ∥ R2 = 12·5/(12+5) = 3.529 Ω
Rth = (R1 ∥ R2) + R3 = 3.529 + 4 = 7.529 Ω
Find Vth, the open-circuit voltage
With a–b open, the only path for Iₛ is through R₃ into node A. Find V_A by superposition of V₁ and Iₛ, then add the drop across R₃.
VA = V1·R2/(R1+R2) + Is·(R1∥R2) = 2.647 + (−5)·3.529 = −15 V
Vth = VB = VA + Is·R3 = −15 + (−5)·4 = −35 V
7.RC & RL transients
Answer: W(∞) = 0.9504 mJ
First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.
Time constant and final current
Long after the switch closes the inductor behaves like a short circuit, so the final current is set by R alone.
τ = L/R = 33 mH / 50 Ω = 0.66 ms
i(∞) = Vs/R = 12/50 = 0.24 A
Stored energy
W(∞) = ½·L·i(∞)² = ½·33·0.24² = 0.9504 mJ
Answer
W(∞) = 0.9504 mJ
8.RC & RL transients
Answer: t = 78.47 ms
First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.
Initial value, final value, time constant
The capacitor voltage cannot jump, so it starts at its stored value and heads for the source voltage.
t = τ·ln((18 − 12)/(16.2 − 12)) = 220·ln(1.429) = 78.47 ms
Answer
t = 78.47 ms
9.AC impedance & phasors
Answer: cos φ = 0.1423
AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.
Reactances
XL = 56.55 Ω, XC = 265.3 Ω
Impedance
|Z| = √(30² + (−208.7)²) = 210.9 Ω
Power factor
cos φ = R/|Z| = 30/210.9 = 0.1423
The circuit is capacitive, so the power factor is leading.
Answer
cos φ = 0.1423
10.AC impedance & phasors
Answer: B = 7.958 Hz
AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.
Resonant frequency
f0 = 1/(2π·√(0.1·0.47·10⁻⁶)) = 734.1 Hz
Quality factor
Q compares the reactance at resonance with the resistance: Q = ω₀L/R.
AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.
Line current
Only the real part of the power does work, so divide by the power factor.
I = P/(V·cos φ) = 6000/(230·0.85) = 30.69 A
Answer
I = 30.69 A
12.AC power & power factor
Answer: Inew = 153.5 A
AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.
Reactive power before and after
The real power P does not change; only the reactive power drawn from the supply does.
Q1 = P·tan φ1 = 35·tan(45.57°) = 35.71 kvar
Q2 = P·tan φ2 = 35·tan(18.19°) = 11.5 kvar
QC = Q1 − Q2 = 24.2 kvar
New line current
Inew = P/(V·cos φ2) = 35000/(240·0.95) = 153.5 A
Answer
Inew = 153.5 A
13.Three-phase power
Answer: IL = 148.2 A
Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ.
Electrical input power
Pin = Pout/η = 75/0.88 = 85.23 kW
Line current
IL = Pin/(√3·VL·cos φ) = 85227/(√3·415·0.8) = 148.2 A
Answer
IL = 148.2 A
14.Three-phase power
Answer: Cph = 456.1 µF
Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ. Power factor correction: capacitors supply reactive power locally, QC = P·(tan φ1 − tan φ2). Each of the three capacitors supplies QC/3 = V²·ω·C, where V is the voltage across that capacitor: VL in a Δ bank, VL/√3 in a Y bank.
Reactive power before and after
The real power is unchanged, so each power factor fixes the reactive power: Q = P·tan φ.
Q1 = 200·tan(acos 0.7) = 200·1.02 = 204 kvar
Q2 = 200·tan(acos 0.92) = 200·0.426 = 85.2 kvar
Reactive power from the capacitors
QC = Q1 − Q2 = 118.8 kvar
Capacitance per phase
In a Δ bank each capacitor is connected between two lines.
V = 480 V, ω = 2π·60 = 377 rad/s
Cph = (QC/3)/(ω·V²) = 39614/(377·480²) = 456.1 µF
Answer
Cph = 456.1 µF
15.Transformers
Answer: I1 = 0.8 A
Ideal transformer: the voltages are in the ratio of the turns and the currents in the inverse ratio: V₁/V₂ = N₁/N₂ = a and I₁/I₂ = N₂/N₁ = 1/a, so the power in equals the power out, V₁·I₁ = V₂·I₂. A load impedance Z on the secondary looks like a²·Z from the primary.
Secondary voltage and current
V2 = 600/5 = 120 V
I2 = 120/30 = 4 A
Primary current
An ideal transformer has no losses: V₁·I₁ = V₂·I₂.
I1 = I2/5 = 0.8 A
Answer
I1 = 0.8 A
Check: the load seen from the primary is a²·RL = 750 Ω, and 600/750 gives the same current.
16.Transformers
Answer: Sη,max = 43.3 kVA
Transformer losses: the core loss (hysteresis and eddy currents) depends on the voltage and is the same at any load. The copper loss in the windings goes with the current squared, so at a fraction x of rated load it is x²·Pcu,fl. Efficiency η = Pout/(Pout + Pcore + Pcu), with Pout = x·S·pf. The efficiency is highest at the load where the copper loss equals the core loss.