The inductor carries no current before the switch closes at t = 0. Find the voltage vL across the inductor at t = 20 ms.
Vs = 24 VR = 10 ΩL = 68 mHt = 20 ms
vL = V
8.RC & RL transientsHard
The switch has been closed for a long time, so the circuit is in steady state. At t = 0 the switch opens. Find the current i2 through R2 at t = 80 ms.
Vs = 15 VR1 = 4.7 kΩR2 = 3.3 kΩC = 22 µFt = 80 ms
i2 = mA
9.AC impedance & phasorsMedium
A resistor and a capacitor are connected in parallel across a 120 V (rms), 100 Hz supply. Find the phase angle φ of the impedance, in degrees (positive when the current lags the voltage).
V = 120 V (rms)f = 100 HzR = 80 ΩC = 22 µF
φ = °
10.AC impedance & phasorsHard
A series RLC circuit has R = 1 Ω, L = 2 mH and C = 0.1 µF. Find its bandwidth B (the width of the band between the half-power frequencies), in Hz.
R = 1 ΩL = 2 mHC = 0.1 µF
B = Hz
11.AC power & power factorMedium
A single-phase motor takes 25 kW at a power factor of 0.65 lagging from a 240 V supply. Find the reactive power Q it draws.
P = 25 kWpf = 0.65V = 240 V
Q = kvar
12.AC power & power factorHard
A single-phase load takes 20 kW at a power factor of 0.7 lagging from a 230 V, 60 Hz supply. A capacitor connected in parallel raises the power factor to 0.95. Find the reactive power QC the capacitor must supply.
P = 20 kWpf1 = 0.7pf2 = 0.95V = 230 Vf = 60 Hz
QC = kvar
13.Three-phase powerMedium
A three-phase induction motor delivers 22 kW of mechanical output power at full load. At this load its efficiency is 88% and its power factor is 0.85 lagging. The supply has a line-to-line voltage of 415 V. Find the line current IL.
Pout = 22 kWη = 88%cos φ = 0.85VL = 415 V
IL = A
14.Three-phase powerHard
A balanced three-phase load takes 250 kW at a power factor of 0.8 lagging from a 690 V (line-to-line), 60 Hz supply. A three-phase capacitor bank in parallel with the load must raise the overall power factor to 0.98 lagging. The real power stays the same. The capacitors are connected in Y. Find the capacitance Cph of each capacitor in µF.
P = 250 kWpf1 = 0.8pf2 = 0.98VL = 690 Vf = 60 Hz
Cph = µF
15.TransformersMedium
An ideal transformer with a turns ratio N₁:N₂ = 20:1 has 4800 V applied to its primary winding. A 4 Ω resistor is connected across the secondary winding. Find the primary current I1.
N1:N2 = 20:1V1 = 4800 VRL = 4 Ω
I1 = A
16.TransformersHard
A single-phase 100 kVA transformer has a core loss of 500 W and a copper loss of 1500 W at rated load. It supplies 75% of its rated kVA at a power factor of 0.85 lagging. Find the total losses Ploss in watts at this load.
Series and parallel resistors: in series the same current flows through each resistor and R = R₁ + R₂ + …. In parallel each resistor has the same voltage and 1/R = 1/R₁ + 1/R₂ + …. A ladder network is reduced one pair at a time until a single equivalent resistance remains.
Combine resistors from the far end
Start at the end farthest from the source and work back towards it. Resistors carrying the same current are in series; resistors across the same two nodes are in parallel.
R3 + R4 = 4 + 3 = 7 Ω
R2 ∥ 7 = 3·7/(3+7) = 2.1 Ω
Req = R1 + 2.1 = 12 + 2.1 = 14.1 Ω
Answer
Req = 14.1 Ω
2.Series & parallel resistors
Answer: IR1 = 0.3265 A
Series and parallel resistors: in series the same current flows through each resistor and R = R₁ + R₂ + …. In parallel each resistor has the same voltage and 1/R = 1/R₁ + 1/R₂ + …. A ladder network is reduced one pair at a time until a single equivalent resistance remains.
Combine resistors from the far end
Start at the end farthest from the source and work back towards it. Resistors carrying the same current are in series; resistors across the same two nodes are in parallel.
R5 + R6 = 2 + 4 = 6 Ω
R4 ∥ 6 = 2.727 Ω
R3 + 2.727 = 17.73 Ω
R2 ∥ 17.73 = 2.566 Ω
Req = R1 + 2.566 = 25 + 2.566 = 27.57 Ω
Current from the source
The source sees only Req, so Ohm’s law gives the current it delivers. That current flows through R₁.
IR1 = V1/Req = 9/27.57 = 0.3265 A
Answer
IR1 = 0.3265 A
3.Nodal analysis
Answer: PIs = 17.16 W
Nodal analysis: choose a reference node, label the unknown node voltages, write Kirchhoff’s current law at each unknown node using Ohm’s law (I = ΔV/R), and solve the resulting equations.
KCL at node A
Currents leaving A through the resistors equal the current pushed into A by sources.
VA/R2 + (VA − V1)/R1 + (VA − VB)/R3 = 0
VA/10 + (VA − 10)/20 + (VA − VB)/10 = 0
0.25·VA − 0.1·VB = 0.5
KCL at node B
Currents leaving B through the resistors equal the current pushed into B by sources.
VB/R4 + (VB − VA)/R3 = Is
VB/3 + (VB − VA)/10 = 2.5
−0.1·VA + 0.4333·VB = 2.5
Solve
Δ = (0.25)(0.4333) − (−0.1)(−0.1) = 0.09833
VA = Δ1/Δ = 0.4667/0.09833 = 4.746 V
VB = Δ2/Δ = 0.675/0.09833 = 6.864 V
Power delivered by the current source
The source pushes Iₛ up into node B, from ground (0 V) to VB. A source whose current leaves its + end delivers P = V·I.
PIs = VB·Is = 6.864·2.5 = 17.16 W
Answer
PIs = 17.16 W
4.Nodal analysis
Answer: Is = 1.25 A
Nodal analysis: choose a reference node, label the unknown node voltages, write Kirchhoff’s current law at each unknown node using Ohm’s law (I = ΔV/R), and solve the resulting equations.
KCL at node A
VA is known, so this equation gives VB.
(VA − V1)/R1 + VA/R2 + (VA − VB)/R3 = 0
(4.5 − 10)/10 + 4.5/6 = (VB − 4.5)/30
0.2 = (VB − 4.5)/30 → VB = 10.5 V
KCL at node B
Currents leaving B through the resistors equal the current pushed into B by sources.
Is = (VB − VA)/R3 + VB/R4 = (10.5 − 4.5)/30 + 10.5/10 = 1.25 A
Answer
Is = 1.25 A
5.Thévenin & Norton
Answer: IN = 0.9643 A
Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.
Find Rth with every source switched off
Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.
R1 ∥ R2 = 10·3/(10+3) = 2.308 Ω
Rth = (R1 ∥ R2) + R3 = 2.308 + 2 = 4.308 Ω
Find Vth, the open-circuit voltage
With a–b open, no current flows through R₃, so there is no drop across it and V_b = V_A. R₁ and R₂ form a voltage divider.
Vth = V1·R2/(R1+R2) = 18·3/(10+3) = 4.154 V
Norton equivalent
A Norton source is the same circuit seen as a current source in parallel with R_th. Its current is the short-circuit current at a–b.
IN = Vth/Rth = 4.154/4.308 = 0.9643 A
6.Thévenin & Norton
Answer: IL = −1 A
Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.
Find Rth with every source switched off
Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.
R1 ∥ R2 = 12·6/(12+6) = 4 Ω
Rth = (R1 ∥ R2) + R3 = 4 + 6 = 10 Ω
Find Vth, the open-circuit voltage
With a–b open, the only path for Iₛ is through R₃ into node A. Find V_A by superposition of V₁ and Iₛ, then add the drop across R₃.
VA = V1·R2/(R1+R2) + Is·(R1∥R2) = 3 + (−2.5)·4 = −7 V
Vth = VB = VA + Is·R3 = −7 + (−2.5)·6 = −22 V
Connect the load to the Thévenin equivalent
The Thévenin source and R_th in series behave exactly like the original circuit at a–b, so the load sees a simple series loop.
IL = Vth/(Rth + RL) = −22/(10 + 12) = −1 A
7.RC & RL transients
Answer: vL = 1.267 V
First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.
Time constant and final current
Long after the switch closes the inductor behaves like a short circuit, so the final current is set by R alone.
τ = L/R = 68 mH / 10 Ω = 6.8 ms
i(∞) = Vs/R = 24/10 = 2.4 A
Inductor voltage
At t = 0 the whole supply voltage appears across the inductor; it then decays to zero.
vL(t) = Vs·e−t/τ = 24·e−20/6.8 = 1.267 V
Answer
vL = 1.267 V
8.RC & RL transients
Answer: i2 = 0.6229 mA
First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.
Initial capacitor voltage
In steady state the capacitor is an open circuit, so R₁ and R₂ form a voltage divider. The capacitor voltage cannot jump when the switch opens.
vC(0) = 15·3.3/(4.7 + 3.3) = 6.188 V
Time constant after the switch opens
τ = R2·C = 3.3·22 = 72.6 ms
Discharge
vC(t) = 6.188·e−80/72.6 = 2.056 V
i2 = vC/R2 = 2.056/3.3 = 0.6229 mA
Answer
i2 = 0.6229 mA
9.AC impedance & phasors
Answer: φ = −47.88 °
AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.
Reactance
XC = 1/(ωC) = 1/(2π·100·22·10⁻⁶) = 72.34 Ω
Branch currents
Both branches are connected straight across the supply, so each sees the full voltage V.
IR = V/R = 120/80 = 1.5 A
IX = V/XC = 120/72.34 = 1.659 A
Total current
The resistor current is in phase with V and the reactive current is 90° out of phase, so they add like the sides of a right triangle.
I = √(IR² + IX²) = √(1.5² + 1.659²) = 2.236 A
Phase angle
The capacitor current leads V, so the total current leads and the angle is negative.
φ = −arctan(IX/IR) = −arctan(1.659/1.5) = −47.88°
Answer
φ = −47.88°
10.AC impedance & phasors
Answer: B = 79.58 Hz
AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.
Resonant frequency
f0 = 1/(2π·√(0.002·0.1·10⁻⁶)) = 11254 Hz
Quality factor
Q compares the reactance at resonance with the resistance: Q = ω₀L/R.
AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.
Angle
φ = arccos(0.65) = 49.46°, tan φ = 1.169
Reactive power
Q = P·tan φ = 25·1.169 = 29.23 kvar
Answer
Q = 29.23 kvar
12.AC power & power factor
Answer: QC = 13.83 kvar
AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.
Reactive power before and after
The real power P does not change; only the reactive power drawn from the supply does.
Q1 = P·tan φ1 = 20·tan(45.57°) = 20.4 kvar
Q2 = P·tan φ2 = 20·tan(18.19°) = 6.574 kvar
QC = Q1 − Q2 = 13.83 kvar
Answer
QC = 13.83 kvar
13.Three-phase power
Answer: IL = 40.92 A
Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ.
Electrical input power
Pin = Pout/η = 22/0.88 = 25 kW
Line current
IL = Pin/(√3·VL·cos φ) = 25000/(√3·415·0.85) = 40.92 A
Answer
IL = 40.92 A
14.Three-phase power
Answer: Cph = 761.8 µF
Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ. Power factor correction: capacitors supply reactive power locally, QC = P·(tan φ1 − tan φ2). Each of the three capacitors supplies QC/3 = V²·ω·C, where V is the voltage across that capacitor: VL in a Δ bank, VL/√3 in a Y bank.
Reactive power before and after
The real power is unchanged, so each power factor fixes the reactive power: Q = P·tan φ.
Q1 = 250·tan(acos 0.8) = 250·0.75 = 187.5 kvar
Q2 = 250·tan(acos 0.98) = 250·0.2031 = 50.76 kvar
Reactive power from the capacitors
QC = Q1 − Q2 = 136.7 kvar
Capacitance per phase
In a Y bank each capacitor is connected between a line and the star point.
Ideal transformer: the voltages are in the ratio of the turns and the currents in the inverse ratio: V₁/V₂ = N₁/N₂ = a and I₁/I₂ = N₂/N₁ = 1/a, so the power in equals the power out, V₁·I₁ = V₂·I₂. A load impedance Z on the secondary looks like a²·Z from the primary.
Secondary voltage and current
V2 = 4800/20 = 240 V
I2 = 240/4 = 60 A
Primary current
An ideal transformer has no losses: V₁·I₁ = V₂·I₂.
I1 = I2/20 = 3 A
Answer
I1 = 3 A
Check: the load seen from the primary is a²·RL = 1600 Ω, and 4800/1600 gives the same current.
16.Transformers
Answer: Ploss = 1344 W
Transformer losses: the core loss (hysteresis and eddy currents) depends on the voltage and is the same at any load. The copper loss in the windings goes with the current squared, so at a fraction x of rated load it is x²·Pcu,fl. Efficiency η = Pout/(Pout + Pcore + Pcu), with Pout = x·S·pf. The efficiency is highest at the load where the copper loss equals the core loss.