A load RL = 2 Ω is connected across a–b. Replace the rest of the circuit with its Thévenin equivalent and find the load current IL.
V1 = 9 VR1 = 2 ΩR2 = 20 ΩR3 = 3 ΩRL = 2 Ω
IL = A
6.Thévenin & NortonHard
A load RL = 5 Ω is connected across a–b. Replace the rest of the circuit with its Thévenin equivalent and find the load current IL.
V1 = 5 VIs = 3 AR1 = 3 ΩR2 = 2 ΩR3 = 4 ΩRL = 5 Ω
IL = A
7.RC & RL transientsMedium
The inductor carries no current before the switch closes at t = 0. How long after the switch closes does the current reach 75% of its final value? Find t.
Vs = 10 VR = 10 ΩL = 150 mH
t = ms
8.RC & RL transientsHard
Just before the switch closes at t = 0, the capacitor holds 15 V with the polarity shown. Find the capacitor voltage vC at t = 75 ms.
Vs = 12 VR = 1 kΩC = 68 µFvC(0) = 15 Vt = 75 ms
vC = V
9.AC impedance & phasorsMedium
A series RLC circuit is connected to a 50 V (rms), 100 Hz supply. Find the real power P taken from the supply.
V = 50 V (rms)f = 100 HzR = 60 ΩL = 250 mHC = 47 µF
P = W
10.AC impedance & phasorsHard
A series RLC circuit is connected to a 230 V (rms), 200 Hz supply. Find the resonant frequency f0 of the circuit.
V = 230 V (rms)f = 200 HzR = 80 ΩL = 250 mHC = 10 µF
f0 = Hz
11.AC power & power factorMedium
A load with impedance Z = 4 + j3 Ω is connected to a 240 V (rms) single-phase supply. Find the reactive power Q it absorbs.
V = 240 VZ = 4 + j3 Ω
Q = var
12.AC power & power factorHard
A 200 kVA single-phase transformer supplies a load of 96 kW at a power factor of 0.85 lagging. How much extra real power ΔP can be added as a resistive (unity power factor) load before the transformer reaches its kVA rating?
Smax = 200 kVAP1 = 96 kWpf1 = 0.85
ΔP = kW
13.Three-phase powerMedium
A balanced Δ-connected load with an impedance of 12 + j9 Ω per phase is connected to a balanced three-phase supply with a line-to-line voltage of 208 V. Find the total real power P absorbed by the load in kW.
VL = 208 VZ = 12 + j9 Ω per phase
P = kW
14.Three-phase powerHard
A balanced three-phase load takes 300 kW at a power factor of 0.72 lagging from a 415 V (line-to-line), 60 Hz supply. A three-phase capacitor bank in parallel with the load must raise the overall power factor to 0.95 lagging. The real power stays the same. The capacitors are connected in Δ. Find the capacitance Cph of each capacitor in µF.
P = 300 kWpf1 = 0.72pf2 = 0.95VL = 415 Vf = 60 Hz
Cph = µF
15.TransformersMedium
An ideal transformer with a turns ratio N₁:N₂ = 10:1 has 2300 V applied to its primary winding. A 30 Ω resistor is connected across the secondary winding. Find the primary current I1.
N1:N2 = 10:1V1 = 2300 VRL = 30 Ω
I1 = A
16.TransformersHard
A single-phase 50 kVA transformer has a core loss of 400 W and a copper loss of 800 W at rated load. It supplies 50% of its rated kVA at a power factor of 0.95 lagging. Find the total losses Ploss in watts at this load.
Series and parallel resistors: in series the same current flows through each resistor and R = R₁ + R₂ + …. In parallel each resistor has the same voltage and 1/R = 1/R₁ + 1/R₂ + …. A ladder network is reduced one pair at a time until a single equivalent resistance remains.
Combine resistors from the far end
Start at the end farthest from the source and work back towards it. Resistors carrying the same current are in series; resistors across the same two nodes are in parallel.
R3 + R4 = 3 + 15 = 18 Ω
R2 ∥ 18 = 12·18/(12+18) = 7.2 Ω
Req = R1 + 7.2 = 12 + 7.2 = 19.2 Ω
Current from the source
The source sees only Req, so Ohm’s law gives the current it delivers. That current flows through R₁.
IR1 = V1/Req = 6/19.2 = 0.3125 A
Answer
IR1 = 0.3125 A
2.Series & parallel resistors
Answer: IR2 = 2.879 A
Series and parallel resistors: in series the same current flows through each resistor and R = R₁ + R₂ + …. In parallel each resistor has the same voltage and 1/R = 1/R₁ + 1/R₂ + …. A ladder network is reduced one pair at a time until a single equivalent resistance remains.
Combine resistors from the far end
Start at the end farthest from the source and work back towards it. Resistors carrying the same current are in series; resistors across the same two nodes are in parallel.
R5 + R6 = 20 + 5 = 25 Ω
R4 ∥ 25 = 3.448 Ω
R3 + 3.448 = 28.45 Ω
R2 ∥ 28.45 = 2.714 Ω
Req = R1 + 2.714 = 2 + 2.714 = 4.714 Ω
Current from the source
The source sees only Req, so Ohm’s law gives the current it delivers. That current flows through R₁.
IR1 = V1/Req = 15/4.714 = 3.182 A
Current through R₂
Subtract the drop across R₁ to get the voltage at node A, which is the voltage across R₂.
VA = V1 − IR1·R1 = 15 − 3.182·2 = 8.636 V
IR2 = VA/R2 = 8.636/3 = 2.879 A
Answer
IR2 = 2.879 A
3.Nodal analysis
Answer: VA = 1.615 V
Nodal analysis: choose a reference node, label the unknown node voltages, write Kirchhoff’s current law at each unknown node using Ohm’s law (I = ΔV/R), and solve the resulting equations.
Set up the nodes
Ground is the bottom wire. Known node voltages come straight from the sources (V1 = 9 V). Unknowns: VA, VB.
KCL at node A
Currents leaving A through the resistors equal the current pushed into A by sources.
VA/R2 + (VA − V1)/R1 + (VA − VB)/R3 = 0
VA/15 + (VA − 9)/6 + (VA − VB)/3 = 0
0.5667·VA − 0.3333·VB = 1.5
KCL at node B
Currents leaving B through the resistors equal the current pushed into B by sources.
Nodal analysis: choose a reference node, label the unknown node voltages, write Kirchhoff’s current law at each unknown node using Ohm’s law (I = ΔV/R), and solve the resulting equations.
Set up the nodes
Ground is the bottom wire. Known node voltages come straight from the sources (V1 = 18 V, V2 = −6 V). Unknowns: VA, VB.
KCL at node A
Currents leaving A through the resistors equal the current pushed into A by sources.
VA/R3 + (VA − V1)/R1 + (VA − VB)/R2 = 0
VA/2 + (VA − 18)/3 + (VA − VB)/6 = 0
VA − 0.1667·VB = 6
KCL at node B
Currents leaving B through the resistors equal the current pushed into B by sources.
VB/R5 + (VB − VA)/R2 + (VB − V2)/R4 = Is
VB/25 + (VB − VA)/6 + (VB − (−6))/8 = (−2.5)
−0.1667·VA + 0.3317·VB = −3.25
Solve
Δ = (1)(0.3317) − (−0.1667)(−0.1667) = 0.3039
VA = Δ1/Δ = 1.448/0.3039 = 4.766 V
VB = Δ2/Δ = −2.25/0.3039 = −7.404 V
Answer
VB = −7.404 V
5.Thévenin & Norton
Answer: IL = 1.2 A
Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.
Find Rth with every source switched off
Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.
R1 ∥ R2 = 2·20/(2+20) = 1.818 Ω
Rth = (R1 ∥ R2) + R3 = 1.818 + 3 = 4.818 Ω
Find Vth, the open-circuit voltage
With a–b open, no current flows through R₃, so there is no drop across it and V_b = V_A. R₁ and R₂ form a voltage divider.
Vth = V1·R2/(R1+R2) = 9·20/(2+20) = 8.182 V
Connect the load to the Thévenin equivalent
The Thévenin source and R_th in series behave exactly like the original circuit at a–b, so the load sees a simple series loop.
IL = Vth/(Rth + RL) = 8.182/(4.818 + 2) = 1.2 A
6.Thévenin & Norton
Answer: IL = 1.725 A
Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.
Find Rth with every source switched off
Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.
R1 ∥ R2 = 3·2/(3+2) = 1.2 Ω
Rth = (R1 ∥ R2) + R3 = 1.2 + 4 = 5.2 Ω
Find Vth, the open-circuit voltage
With a–b open, the only path for Iₛ is through R₃ into node A. Find V_A by superposition of V₁ and Iₛ, then add the drop across R₃.
VA = V1·R2/(R1+R2) + Is·(R1∥R2) = 2 + 3·1.2 = 5.6 V
Vth = VB = VA + Is·R3 = 5.6 + 3·4 = 17.6 V
Connect the load to the Thévenin equivalent
The Thévenin source and R_th in series behave exactly like the original circuit at a–b, so the load sees a simple series loop.
IL = Vth/(Rth + RL) = 17.6/(5.2 + 5) = 1.725 A
7.RC & RL transients
Answer: t = 20.79 ms
First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.
Time constant and final current
Long after the switch closes the inductor behaves like a short circuit, so the final current is set by R alone.
τ = L/R = 150 mH / 10 Ω = 15 ms
i(∞) = Vs/R = 10/10 = 1 A
Solve for the time
0.75 = 1 − e−t/τ → t = −τ·ln(1 − 0.75)
t = −15·ln(0.25) = 20.79 ms
Answer
t = 20.79 ms
8.RC & RL transients
Answer: vC = 13 V
First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.
Initial value, final value, time constant
The capacitor voltage cannot jump, so it starts at its stored value and heads for the source voltage.
vC(0) = 15 V, vC(∞) = Vs = 12 V
τ = R·C = 1 kΩ · 68 µF = 68 ms
vC(t) = 12 + (15 − 12)·e−t/τ
Voltage at the given time
vC(75) = 12 + (3)·e−75/68 = 13 V
Answer
vC = 13 V
9.AC impedance & phasors
Answer: P = 7.986 W
AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.
Reactances
XL = 157.1 Ω, XC = 33.86 Ω
Impedance
|Z| = √(60² + (123.2)²) = 137 Ω
Real power
Inductors and capacitors only store and return energy; the resistor absorbs all of the real power.
I = 50/137 = 0.3648 A
P = I²·R = 0.3648²·60 = 7.986 W
Answer
P = 7.986 W
10.AC impedance & phasors
Answer: f0 = 100.7 Hz
AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.
Resonance
At resonance the inductive and capacitive reactances cancel: ωL = 1/(ωC). The supply frequency does not matter.
AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.
Current
|Z| = √(4² + 3²) = 5 Ω
I = V/|Z| = 240/5 = 48 A
Reactive power
Q = I²·X = 48²·3 = 6912 var
Answer
Q = 6912 var
12.AC power & power factor
Answer: ΔP = 94.95 kW
AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.
Reactive power of the existing load
Q1 = 96·tan(arccos 0.85) = 59.5 kvar
Largest total real power
At full rating S = Smax, and Q is unchanged by the resistive load.
P = √(Smax² − Q1²) = √(200² − 59.5²) = 190.9 kW
Extra real power
ΔP = 190.9 − 96 = 94.95 kW
Answer
ΔP = 94.95 kW
13.Three-phase power
Answer: P = 6.922 kW
Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ.
Phase voltage
Vph = VL = 208 V
Phase current
|Z| = √(12² + 9²) = 15 Ω
Iph = 208/15 = 13.87 A
Total real power
Only the resistive part of each impedance absorbs real power.
P = 3·Iph²·R = 3·13.87²·12 = 6.922 kW
Answer
P = 6.922 kW
Check: cos φ = R/|Z| = 0.8, and √3·VL·IL·cos φ gives the same power.
14.Three-phase power
Answer: Cph = 978.3 µF
Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ. Power factor correction: capacitors supply reactive power locally, QC = P·(tan φ1 − tan φ2). Each of the three capacitors supplies QC/3 = V²·ω·C, where V is the voltage across that capacitor: VL in a Δ bank, VL/√3 in a Y bank.
Reactive power before and after
The real power is unchanged, so each power factor fixes the reactive power: Q = P·tan φ.
Q1 = 300·tan(acos 0.72) = 300·0.9639 = 289.2 kvar
Q2 = 300·tan(acos 0.95) = 300·0.3287 = 98.61 kvar
Reactive power from the capacitors
QC = Q1 − Q2 = 190.6 kvar
Capacitance per phase
In a Δ bank each capacitor is connected between two lines.
V = 415 V, ω = 2π·60 = 377 rad/s
Cph = (QC/3)/(ω·V²) = 63517/(377·415²) = 978.3 µF
Answer
Cph = 978.3 µF
15.Transformers
Answer: I1 = 0.7667 A
Ideal transformer: the voltages are in the ratio of the turns and the currents in the inverse ratio: V₁/V₂ = N₁/N₂ = a and I₁/I₂ = N₂/N₁ = 1/a, so the power in equals the power out, V₁·I₁ = V₂·I₂. A load impedance Z on the secondary looks like a²·Z from the primary.
Secondary voltage and current
V2 = 2300/10 = 230 V
I2 = 230/30 = 7.667 A
Primary current
An ideal transformer has no losses: V₁·I₁ = V₂·I₂.
I1 = I2/10 = 0.7667 A
Answer
I1 = 0.7667 A
Check: the load seen from the primary is a²·RL = 3000 Ω, and 2300/3000 gives the same current.
16.Transformers
Answer: Ploss = 600 W
Transformer losses: the core loss (hysteresis and eddy currents) depends on the voltage and is the same at any load. The copper loss in the windings goes with the current squared, so at a fraction x of rated load it is x²·Pcu,fl. Efficiency η = Pout/(Pout + Pcore + Pcu), with Pout = x·S·pf. The efficiency is highest at the load where the copper loss equals the core loss.