Mass balance
- Steady state
- in = out
- Total balance
- ṁ1 + ṁ2 = ṁ3
- Component balance
- ṁ1x1 + ṁ2x2 = ṁ3x3
- Evaporator
- F·xF = P·xP, W = F − P
Formula sheets, the key method steps for every topic and 24 practice problems, with full solutions at the back.
How much of stream 2 must be added each hour to stream 1 so that the blended product contains 30% NaOH? Find ṁ2.
An evaporator concentrates a sugar solution by boiling off pure water. Find the product flow P in kg/h.
Hot glycol mix cools water in a counter-flow heat exchanger with no heat loss. Find the water outlet temperature tout.
Hot light oil heats water in an exchanger that loses 5% of the heat released by the hot stream to the surroundings. Find the water flow rate ṁc needed.
A tank of 5 L contains 100 g of He at 45 °C. Treat it as an ideal gas and find the pressure P.
Find the density ρ of O₂ at 250 kPa and 80 °C, treating it as an ideal gas.
8 g of Na and 80 g of Cl2 react according to 2Na + Cl2 → 2NaCl. What mass m of NaCl can form?
In the reaction CH4 + 2O2 → CO2 + 2H2O, 30 g of CH4 reacts completely (the other reactants are in excess) and 50.55 g of H2O is collected. Find the percent yield Y.
0.8 mol/L of H₂ and 0.8 mol/L of I₂ are put in a container and react: H₂ + I₂ ⇌ 2HI, with Kc = 9. Find the equilibrium concentration [H2].
PCl₅ decomposes: PCl₅ ⇌ PCl₃ + Cl₂, with Kc = 0.02 at the reaction temperature. A container starts with 0.25 mol/L of PCl₅ only. Find the equilibrium concentration [Cl2].
A 200 g block of copper (c = 0.385 J/(g·°C)) at 80 °C is dropped into 100 g of water (c = 4.18 J/(g·°C)) at 21 °C in an insulated cup. Find the final temperature Tf.
Use the standard enthalpies of formation to find ΔH° for the reaction 2C2H6 + 7O₂ → 4CO₂ + 6H₂O(l).
A reaction with rate law −rA = k·CA² has k = 0.1 L/(mol·min) and starts at 0.5 mol/L. Find the concentration CA after 5 min.
Two experiments measure the initial rate of A → products. With CA0 = 0.4 mol/L the rate is 0.012 mol/(L·s); with CA0 = 0.8 mol/L it is 0.017 mol/(L·s). Find the reaction order n with respect to A.
A liquid-phase first-order reaction A → B (k = 0.08 min⁻¹) runs in a 100 L plug-flow reactor (PFR). The feed enters at 10 L/min with CA0 = 2.5 mol/L. The density is constant and the reactor is at steady state. Find the outlet concentration CA.
A first-order liquid-phase reaction (k = 0.25 min⁻¹) runs in two equal CSTRs in series, each of 250 L. The feed rate is 10 L/min, the density is constant and the reactors are at steady state. Find the overall conversion X in percent.
A counter-flow heat exchanger transfers 310 kW. The hot fluid cools from 110 to 85 °C and the cold fluid heats from 10 to 20 °C. The overall heat transfer coefficient is 200 W/(m²·K). Find the heat transfer area A needed.
In a counter-flow double-pipe heat exchanger, hot oil (0.2 kg/s, cp = 2.1 kJ/(kg·K)) flows in the inner tube and cools from 105 to 65 °C. Water (0.3 kg/s, cp = 4.18 kJ/(kg·K)) in the annulus enters at 10 °C. The inner tube has a diameter of 50 mm, and U = 200 W/(m²·K) is based on this diameter. Find the tube length L needed.
A wall is made of 200 mm of wood and 50 mm of brick, with an area of 6 m². The outer faces are at 21 °C and -1 °C. Find the heat flow Q̇ through the wall.
A wall of 100 mm concrete and 150 mm mineral wool separates a room at 20 °C from outside air at -1 °C. The convection coefficients are 6 W/(m²·K) inside and 30 W/(m²·K) outside, and the wall area is 10 m². Find the temperature Ts of the inside surface of the wall.
Water flows at 25 L/s through a pipe 800 m long with an inside diameter of 250 mm. Use the Darcy friction factor f = 0.028 and g = 9.81 m/s². Find the friction head loss hf.
A pipe 200 m long with an inside diameter of 200 mm (Darcy friction factor f = 0.02) runs from an open reservoir and discharges as a free jet into the air. The minor losses are a square-edged entrance (K = 0.5), 4 bends (K = 0.3 each) and a valve (K = 5). Use g = 9.81 m/s². How far H must the reservoir surface be above the pipe outlet for a flow rate of 75 L/s?
In a test, a pump delivers 100 L/s of water (ρ = 1000 kg/m³) against a head of 52 m while its shaft takes 62.2 kW. Use g = 9.81 m/s². Find the pump efficiency η in percent.
A pump moves 80 L/s of water (ρ = 1000 kg/m³) from an open lower reservoir to an upper tank whose water surface is 8 m higher. The pipe is 400 m long with an inside diameter of 200 mm and a Darcy friction factor f = 0.018; the minor-loss coefficients add up to ΣK = 5 (entrance and exit included). Use g = 9.81 m/s². Find the head H the pump must add.
Answer: ṁ2 = 66.67 kg/h
Steady-state mass balance: in = out for the total and for each component. Blending problems combine both.
Answer: P = 640 kg/h
Tie component: a component that passes through unchanged in one stream (here the solute) links the flows directly. Then the total balance gives the rest.
Answer: tout = 38.71 °C
Exchanger energy balance: with no losses, ṁhcp,h(Th,in − Th,out) = ṁccp,c(tout − tin).
Answer: ṁc = 1.193 kg/s
Energy balance with losses: heat released = heat absorbed + heat lost.
Answer: P = 13216 kPa
Ideal gas law: PV = nRT, with n = m/M.
Answer: ρ = 2.725 kg/m³
Ideal gas density: ρ = PM/(RT).
Answer: m = 20.34 g
Stoichiometry: a balanced equation counts particles, not grams. Convert mass to moles with n = m/M, use the coefficients of the equation as the mole ratio, then convert back with m = n·M. With two reactants, the limiting reactant is the one that runs out first and fixes how much product forms.
Answer: Y = 74.99 %
Stoichiometry: a balanced equation counts particles, not grams. Convert mass to moles with n = m/M, use the coefficients of the equation as the mole ratio, then convert back with m = n·M. With two reactants, the limiting reactant is the one that runs out first and fixes how much product forms.
Answer: [H2] = 0.32 mol/L
Chemical equilibrium: for aA + bB ⇌ cC + dD, the equilibrium constant is Kc = [C]c[D]d/([A]a[B]b), using concentrations at equilibrium. An ICE table (Initial, Change, Equilibrium) links the starting amounts to the equilibrium amounts through one unknown x, scaled by the coefficients.
Answer: [Cl2] = 0.06141 mol/L
Chemical equilibrium: for aA + bB ⇌ cC + dD, the equilibrium constant is Kc = [C]c[D]d/([A]a[B]b), using concentrations at equilibrium. An ICE table (Initial, Change, Equilibrium) links the starting amounts to the equilibrium amounts through one unknown x, scaled by the coefficients.
Answer: Tf = 30.18 °C
Heat and enthalpy: heating a substance takes q = m·c·ΔT. In a calorimeter the heat lost by the hot object equals the heat gained by the cold one. The enthalpy change of a reaction follows from enthalpies of formation: ΔH° = ΣΔH°f(products) − ΣΔH°f(reactants), each multiplied by its coefficient.
Answer: ΔH° = −3119 kJ
Heat and enthalpy: heating a substance takes q = m·c·ΔT. In a calorimeter the heat lost by the hot object equals the heat gained by the cold one. The enthalpy change of a reaction follows from enthalpies of formation: ΔH° = ΣΔH°f(products) − ΣΔH°f(reactants), each multiplied by its coefficient.
Negative: the reaction gives off heat (exothermic).
Answer: CA = 0.4 mol/L
Reaction rates: for a first-order reaction −dC/dt = kC, so C = C₀·e−kt and the half-life ln 2/k does not depend on concentration. For a second-order reaction 1/C = 1/C₀ + kt. The rate constant rises with temperature following Arrhenius: k = A·e−Ea/(RT).
Answer: n = 0.5025
Method of initial rates: for r = k·Cⁿ, comparing two runs that differ only in the starting concentration removes k: r₂/r₁ = (C₂/C₁)ⁿ. Doubling C doubles the rate for first order and quadruples it for second order.
Answer: CA = 1.123 mol/L
Ideal reactors, first-order reaction (−rA = k·CA) at steady state, with space time τ = V/Q. A CSTR is perfectly mixed, so the whole volume reacts at the low outlet concentration: τ = X/(k·(1 − X)) and CA = CA0/(1 + k·τ). In a PFR each slice of fluid reacts like a small batch reactor: τ = ln(1/(1 − X))/k and CA = CA0·e−k·τ. For the same conversion a CSTR always needs more volume than a PFR.
Conversion: X = 55.07%.
Answer: X = 98.1 %
Ideal reactors, first-order reaction (−rA = k·CA) at steady state, with space time τ = V/Q. A CSTR is perfectly mixed, so the whole volume reacts at the low outlet concentration: τ = X/(k·(1 − X)) and CA = CA0/(1 + k·τ). In a PFR each slice of fluid reacts like a small batch reactor: τ = ln(1/(1 − X))/k and CA = CA0·e−k·τ. For the same conversion a CSTR always needs more volume than a PFR.
Answer: A = 18.84 m²
LMTD method: the temperature difference between the streams changes along the exchanger, so the rate equation uses its logarithmic mean: Q̇ = U·A·ΔTlm, with ΔTlm = (ΔT₁ − ΔT₂)/ln(ΔT₁/ΔT₂), where ΔT₁ and ΔT₂ are the differences at the two ends. Counter-flow gives a larger ΔTlm than parallel flow for the same inlet and outlet temperatures.
In counter-flow the hot inlet faces the cold outlet, and the hot outlet faces the cold inlet.
Answer: L = 7.931 m
LMTD method: the temperature difference between the streams changes along the exchanger, so the rate equation uses its logarithmic mean: Q̇ = U·A·ΔTlm, with ΔTlm = (ΔT₁ − ΔT₂)/ln(ΔT₁/ΔT₂), where ΔT₁ and ΔT₂ are the differences at the two ends. Counter-flow gives a larger ΔTlm than parallel flow for the same inlet and outlet temperatures.
In counter-flow the hot inlet faces the cold outlet, and the hot outlet faces the cold inlet.
Answer: Q̇ = 105.9 W
Thermal resistance: steady heat flow through layers in series behaves like current through resistors in series: Q̇ = ΔT/ΣR, with R = L/(kA) for a conducting layer and R = 1/(hA) for a convecting surface. The temperature drop across each layer is proportional to its resistance.
Answer: Ts = 19.13 °C
Thermal resistance: steady heat flow through layers in series behaves like current through resistors in series: Q̇ = ΔT/ΣR, with R = L/(kA) for a conducting layer and R = 1/(hA) for a convecting surface. The temperature drop across each layer is proportional to its resistance.
Answer: hf = 1.185 m
Pipe flow: the Reynolds number Re = V·D/ν = ρ·V·D/μ tells laminar flow (Re below about 2000) from turbulent flow (above about 4000). Friction along a pipe costs the Darcy–Weisbach head loss hf = f·(L/D)·V²/(2g). Fittings, valves, the entrance and the exit add minor losses hm = ΣK·V²/(2g). Between two open reservoir surfaces the energy equation gives Δz = hf + hm, with the exit loss K = 1 included.
Answer: H = 8.046 m
Pipe flow: the Reynolds number Re = V·D/ν = ρ·V·D/μ tells laminar flow (Re below about 2000) from turbulent flow (above about 4000). Friction along a pipe costs the Darcy–Weisbach head loss hf = f·(L/D)·V²/(2g). Fittings, valves, the entrance and the exit add minor losses hm = ΣK·V²/(2g). Between two open reservoir surfaces the energy equation gives Δz = hf + hm, with the exit loss K = 1 included.
The outlet jet still carries its velocity head; it is not a loss but it has to be supplied.
Answer: η = 82.01 %
Pump power: the power given to the water is the hydraulic power Ph = ρ·g·Q·H = Q·Δp. The shaft must deliver more because the pump loses some: Pshaft = Ph/ηpump, and the motor draws Pel = Pshaft/ηmotor. The pump head H follows from the energy equation: static lift + pressure head + all friction and minor losses.
Answer: H = 21.55 m
Pump power: the power given to the water is the hydraulic power Ph = ρ·g·Q·H = Q·Δp. The shaft must deliver more because the pump loses some: Pshaft = Ph/ηpump, and the motor draws Pel = Pshaft/ηmotor. The pump head H follows from the energy equation: static lift + pressure head + all friction and minor losses.
Both surfaces are open and practically at rest, so pressure and velocity terms drop out.
This is independent practice material. ExamProblems is not affiliated with or endorsed by the organisation that runs this exam, and the exam name is used only to describe the content. The FE exam is run by NCEES, which is not affiliated with ExamProblems and does not endorse it.
ExamProblems · examproblems.com/courses/fe-exam-chemical