Mass balance
- Steady state
- in = out
- Total balance
- ṁ1 + ṁ2 = ṁ3
- Component balance
- ṁ1x1 + ṁ2x2 = ṁ3x3
- Evaporator
- F·xF = P·xP, W = F − P
Formula sheets, the key method steps for every topic and 24 practice problems, with full solutions at the back.
How much of stream 2 must be added each hour to stream 1 so that the blended product contains 25% sugar? Find ṁ2.
An evaporator concentrates a sugar solution by boiling off pure water. Find the water evaporated W in kg/h.
Hot light oil cools water in a counter-flow heat exchanger with no heat loss. Find the water outlet temperature tout.
Hot light oil heats water in an exchanger that loses 10% of the heat released by the hot stream to the surroundings. Find the water flow rate ṁc needed.
A tank of 30 L contains 50 g of Ar at 95 °C. Treat it as an ideal gas and find the pressure P.
A fixed amount of N₂ goes from 300 kPa, 5 L, 10 °C to 350 kPa and 90 °C. Find the new volume V2.
12 g of H2 and 64 g of O2 react according to 2H2 + O2 → 2H2O. What mass m of H2O can form?
In the reaction Fe2O3 + 3CO → 2Fe + 3CO2, 24 g of Fe2O3 reacts completely (the other reactants are in excess) and 12.59 g of Fe is collected. Find the percent yield Y.
0.5 mol/L of H₂ and 0.5 mol/L of I₂ are put in a container and react: H₂ + I₂ ⇌ 2HI, with Kc = 25. Find the equilibrium concentration [H2].
PCl₅ decomposes: PCl₅ ⇌ PCl₃ + Cl₂, with Kc = 0.2 at the reaction temperature. A container starts with 0.1 mol/L of PCl₅ only. Find the equilibrium concentration [PCl5].
A 200 g block of lead (c = 0.129 J/(g·°C)) at 130 °C is dropped into 100 g of water (c = 4.18 J/(g·°C)) at 19 °C in an insulated cup. Find the final temperature Tf.
Use the standard enthalpies of formation to find the heat q released when 10 g of C6H12O6 (M = 180.16 g/mol) burns completely: C6H12O6 + 6O₂ → 6CO₂ + 6H₂O(l). Give q as a positive number.
In a first-order reaction the concentration of A falls from 0.5 mol/L to 0.25 mol/L in 60 min. Find the rate constant k.
The rate constant of a reaction is 0.05 min⁻¹ at 30 °C and 3.64 min⁻¹ at 60 °C. Find the activation energy Ea.
A first-order liquid-phase reaction A → B with k = 0.15 min⁻¹ is carried out in a plug-flow reactor (PFR) fed at 40 L/min. The density is constant and the reactor is at steady state. Find the reactor volume V in litres for 85% conversion of A.
A first-order liquid-phase reaction (k = 0.12 min⁻¹) runs in two equal CSTRs in series, each of 200 L. The feed rate is 40 L/min, the density is constant and the reactors are at steady state. Find the overall conversion X in percent.
In a condenser, steam condenses at a constant 100 °C on the outside of the tubes. Cooling water (3 kg/s, cp = 4.18 kJ/(kg·K)) flows through the tubes and heats from 20 to 75 °C. The overall heat transfer coefficient is 3500 W/(m²·K). Find the heat transfer area A needed.
In a counter-flow heat exchanger both streams have the same heat capacity rate, ṁ·cp = 1.5 kW/K. The hot stream enters at 165 °C and the cold stream at 30 °C. The exchanger has A = 2 m² and U = 800 W/(m²·K). Find the hot outlet temperature Th,out.
A wall is made of 150 mm of glass and 100 mm of concrete, with an area of 20 m². The outer faces are at 18 °C and -8 °C. Find the temperature Ti at the interface between the two layers.
A wall of 200 mm expanded polystyrene and 150 mm brick separates a room at 20 °C from outside air at 5 °C. The convection coefficients are 6 W/(m²·K) inside and 30 W/(m²·K) outside, and the wall area is 12 m². Find the temperature Ts of the inside surface of the wall.
Water (ρ = 1000 kg/m³) flows at 1.2 m/s through a horizontal pipe, 800 m long, with an inside diameter of 150 mm. Use the Darcy friction factor f = 0.018 and g = 9.81 m/s². Find the pressure drop Δp over the pipe in kPa.
A pipe 100 m long with an inside diameter of 250 mm (Darcy friction factor f = 0.022) runs from an open reservoir and discharges as a free jet into the air. The minor losses are a square-edged entrance (K = 0.5), 4 bends (K = 0.3 each) and a valve (K = 2). Use g = 9.81 m/s². How far H must the reservoir surface be above the pipe outlet for a flow rate of 150 L/s?
A pump with an efficiency of 80% delivers 150 L/s of water (ρ = 1000 kg/m³) against a head of 64 m. Use g = 9.81 m/s². Find the shaft power Pshaft needed, in kW.
A pump moves 80 L/s of water (ρ = 1000 kg/m³) from an open lower reservoir to an upper tank whose water surface is 25 m higher. The pipe is 300 m long with an inside diameter of 200 mm and a Darcy friction factor f = 0.015; the minor-loss coefficients add up to ΣK = 6 (entrance and exit included). Use g = 9.81 m/s². The pump efficiency is 78%. Find the shaft power Pshaft in kW.
Answer: ṁ2 = 480 kg/h
Steady-state mass balance: in = out for the total and for each component. Blending problems combine both.
Answer: W = 1260 kg/h
Tie component: a component that passes through unchanged in one stream (here the solute) links the flows directly. Then the total balance gives the rest.
Answer: tout = 85.36 °C
Exchanger energy balance: with no losses, ṁhcp,h(Th,in − Th,out) = ṁccp,c(tout − tin).
Answer: ṁc = 0.9043 kg/s
Energy balance with losses: heat released = heat absorbed + heat lost.
Answer: P = 127.7 kPa
Ideal gas law: PV = nRT, with n = m/M.
Answer: V2 = 5.497 L
Combined gas law: for a fixed amount of ideal gas, P1V1/T1 = P2V2/T2.
Answer: m = 72.08 g
Stoichiometry: a balanced equation counts particles, not grams. Convert mass to moles with n = m/M, use the coefficients of the equation as the mole ratio, then convert back with m = n·M. With two reactants, the limiting reactant is the one that runs out first and fixes how much product forms.
Answer: Y = 75 %
Stoichiometry: a balanced equation counts particles, not grams. Convert mass to moles with n = m/M, use the coefficients of the equation as the mole ratio, then convert back with m = n·M. With two reactants, the limiting reactant is the one that runs out first and fixes how much product forms.
Answer: [H2] = 0.1429 mol/L
Chemical equilibrium: for aA + bB ⇌ cC + dD, the equilibrium constant is Kc = [C]c[D]d/([A]a[B]b), using concentrations at equilibrium. An ICE table (Initial, Change, Equilibrium) links the starting amounts to the equilibrium amounts through one unknown x, scaled by the coefficients.
Answer: [PCl5] = 0.02679 mol/L
Chemical equilibrium: for aA + bB ⇌ cC + dD, the equilibrium constant is Kc = [C]c[D]d/([A]a[B]b), using concentrations at equilibrium. An ICE table (Initial, Change, Equilibrium) links the starting amounts to the equilibrium amounts through one unknown x, scaled by the coefficients.
Answer: Tf = 25.45 °C
Heat and enthalpy: heating a substance takes q = m·c·ΔT. In a calorimeter the heat lost by the hot object equals the heat gained by the cold one. The enthalpy change of a reaction follows from enthalpies of formation: ΔH° = ΣΔH°f(products) − ΣΔH°f(reactants), each multiplied by its coefficient.
Answer: q = 155.5 kJ
Heat and enthalpy: heating a substance takes q = m·c·ΔT. In a calorimeter the heat lost by the hot object equals the heat gained by the cold one. The enthalpy change of a reaction follows from enthalpies of formation: ΔH° = ΣΔH°f(products) − ΣΔH°f(reactants), each multiplied by its coefficient.
Answer: k = 0.01155 min⁻¹
Integrated rate laws: zero order: C = C₀ − kt (straight line, t½ = C₀/(2k)); first order: ln(C₀/C) = kt (t½ = ln 2/k); second order: 1/C − 1/C₀ = kt (t½ = 1/(kC₀)). Conversion X means C = C₀(1 − X).
Answer: Ea = 120 kJ/mol
Reaction rates: for a first-order reaction −dC/dt = kC, so C = C₀·e−kt and the half-life ln 2/k does not depend on concentration. For a second-order reaction 1/C = 1/C₀ + kt. The rate constant rises with temperature following Arrhenius: k = A·e−Ea/(RT).
Answer: V = 505.9 L
Ideal reactors, first-order reaction (−rA = k·CA) at steady state, with space time τ = V/Q. A CSTR is perfectly mixed, so the whole volume reacts at the low outlet concentration: τ = X/(k·(1 − X)) and CA = CA0/(1 + k·τ). In a PFR each slice of fluid reacts like a small batch reactor: τ = ln(1/(1 − X))/k and CA = CA0·e−k·τ. For the same conversion a CSTR always needs more volume than a PFR.
Answer: X = 60.94 %
Ideal reactors, first-order reaction (−rA = k·CA) at steady state, with space time τ = V/Q. A CSTR is perfectly mixed, so the whole volume reacts at the low outlet concentration: τ = X/(k·(1 − X)) and CA = CA0/(1 + k·τ). In a PFR each slice of fluid reacts like a small batch reactor: τ = ln(1/(1 − X))/k and CA = CA0·e−k·τ. For the same conversion a CSTR always needs more volume than a PFR.
Answer: A = 4.167 m²
LMTD method: the temperature difference between the streams changes along the exchanger, so the rate equation uses its logarithmic mean: Q̇ = U·A·ΔTlm, with ΔTlm = (ΔT₁ − ΔT₂)/ln(ΔT₁/ΔT₂), where ΔT₁ and ΔT₂ are the differences at the two ends. Counter-flow gives a larger ΔTlm than parallel flow for the same inlet and outlet temperatures.
Answer: Th,out = 95.32 °C
LMTD method: the temperature difference between the streams changes along the exchanger, so the rate equation uses its logarithmic mean: Q̇ = U·A·ΔTlm, with ΔTlm = (ΔT₁ − ΔT₂)/ln(ΔT₁/ΔT₂), where ΔT₁ and ΔT₂ are the differences at the two ends. Counter-flow gives a larger ΔTlm than parallel flow for the same inlet and outlet temperatures.
The cold outlet sits opposite the hot inlet: Tc,out = Tc,in + (Th,in − Th,out), so ΔT₁ = Th,in − Tc,out = Th,out − Tc,in = ΔT₂.
Heat transferred: Q̇ = 104.5 kW; the cold stream leaves at 99.68 °C.
Answer: Ti = 0.1569 °C
Thermal resistance: steady heat flow through layers in series behaves like current through resistors in series: Q̇ = ΔT/ΣR, with R = L/(kA) for a conducting layer and R = 1/(hA) for a convecting surface. The temperature drop across each layer is proportional to its resistance.
The temperature drops across the first layer by Q̇·R₁.
Answer: Ts = 19.59 °C
Thermal resistance: steady heat flow through layers in series behaves like current through resistors in series: Q̇ = ΔT/ΣR, with R = L/(kA) for a conducting layer and R = 1/(hA) for a convecting surface. The temperature drop across each layer is proportional to its resistance.
Answer: Δp = 69.12 kPa
Pipe flow: the Reynolds number Re = V·D/ν = ρ·V·D/μ tells laminar flow (Re below about 2000) from turbulent flow (above about 4000). Friction along a pipe costs the Darcy–Weisbach head loss hf = f·(L/D)·V²/(2g). Fittings, valves, the entrance and the exit add minor losses hm = ΣK·V²/(2g). Between two open reservoir surfaces the energy equation gives Δz = hf + hm, with the exit loss K = 1 included.
The pipe is horizontal and the velocity does not change, so the energy equation reduces to Δp = ρ·g·hf.
Answer: H = 6.425 m
Pipe flow: the Reynolds number Re = V·D/ν = ρ·V·D/μ tells laminar flow (Re below about 2000) from turbulent flow (above about 4000). Friction along a pipe costs the Darcy–Weisbach head loss hf = f·(L/D)·V²/(2g). Fittings, valves, the entrance and the exit add minor losses hm = ΣK·V²/(2g). Between two open reservoir surfaces the energy equation gives Δz = hf + hm, with the exit loss K = 1 included.
The outlet jet still carries its velocity head; it is not a loss but it has to be supplied.
Answer: Pshaft = 117.7 kW
Pump power: the power given to the water is the hydraulic power Ph = ρ·g·Q·H = Q·Δp. The shaft must deliver more because the pump loses some: Pshaft = Ph/ηpump, and the motor draws Pel = Pshaft/ηmotor. The pump head H follows from the energy equation: static lift + pressure head + all friction and minor losses.
Answer: Pshaft = 34.63 kW
Pump power: the power given to the water is the hydraulic power Ph = ρ·g·Q·H = Q·Δp. The shaft must deliver more because the pump loses some: Pshaft = Ph/ηpump, and the motor draws Pel = Pshaft/ηmotor. The pump head H follows from the energy equation: static lift + pressure head + all friction and minor losses.
This is independent practice material. ExamProblems is not affiliated with or endorsed by the organisation that runs this exam, and the exam name is used only to describe the content. The FE exam is run by NCEES, which is not affiliated with ExamProblems and does not endorse it.
ExamProblems · examproblems.com/courses/fe-exam-chemical