FE Chemical exam practice: cram pack

Formula sheets, the key method steps for every topic and 24 practice problems, with full solutions at the back.

New problemsBack to the course

In the print window, choose “Save as PDF” to keep a copy on your device.

1Formulas and methods

Mass balance

Steady state
in = out
Total balance
ṁ1 + ṁ2 = ṁ3
Component balance
ṁ1x1 + ṁ2x2 = ṁ3x3
Evaporator
F·xF = P·xP, W = F − P

Energy balance

Sensible heat
Q = ṁ·cp·ΔT
Latent heat
Q = ṁ·hfg
Mixing
ΣṁcpTin = ΣṁcpTout
Water
cp ≈ 4.18 kJ/(kg·K)

Ideal gas law

Ideal gas law
pV = nRT
Gas constant
R = 8.314 J/(mol·K)
Combined gas law
p1V1/T1 = p2V2/T2
Moles
n = m/M
Temperature
T[K] = T[°C] + 273.15

Stoichiometry

Moles
n = m/M
Concentration
c = n/V
Mole ratio
use the coefficients of the balanced equation
Limiting reactant
the one that runs out first
Percent yield
actual / theoretical × 100%

Method

  1. Write and balance the chemical equation.
  2. Convert the given mass to moles: n = m/M.
  3. Use the coefficients as the mole ratio to find the moles of the substance you want.
  4. Convert back to mass with m = n·M. With two reactants, find the limiting reactant first.

Chemical equilibrium

Equilibrium constant
Kc = [C]c[D]d/([A]a[B]b)
ICE table
Initial, Change (×coefficient), Equilibrium
Quadratic
x = (−b + √(b² − 4ac))/(2a)

Method

  1. Write Kc with products over reactants, each raised to the power of its coefficient.
  2. Set up an ICE table: Initial, Change (in steps of x times the coefficients), Equilibrium.
  3. Put the equilibrium expressions into Kc and solve for x.
  4. Check whether x is small enough for an approximation; otherwise solve the quadratic.

Calorimetry & enthalpy

Heat
q = m·c·ΔT
Water
c = 4.18 J/(g·°C)
Calorimeter
heat lost = heat gained
Enthalpy of reaction
ΔH° = ΣΔH°f(products) − ΣΔH°f(reactants)

Reaction kinetics

First order
ln(CA/CA0) = −kt
Half-life (first order)
t½ = ln 2/k
Second order
1/CA = 1/CA0 + kt
Arrhenius
k = A·e−Ea/(RT)
Two temperatures
ln(k2/k1) = (Ea/R)(1/T1 − 1/T2)

Reactor sizing (CSTR & PFR)

Space time
τ = V/Q
CSTR, first order
τ = X/(k·(1 − X)), CA = CA0/(1 + kτ)
PFR, first order
τ = ln(1/(1 − X))/k, CA = CA0·e−kτ
Conversion from volume
CSTR: X = kτ/(1 + kτ), PFR: X = 1 − e−kτ
N equal CSTRs in series
X = 1 − 1/(1 + kτi)N

Heat exchangers (LMTD)

Heat duty
Q = U·A·ΔTlm
Log mean temperature difference
ΔTlm = (ΔT1 − ΔT2)/ln(ΔT1/ΔT2)
Stream balance
Q = ṁcp(Tin − Tout)

Heat conduction

Fourier’s law
Q̇ = kAΔT/L
Conduction resistance
R = L/(kA)
Convection resistance
R = 1/(hA)
Resistances in series
Q̇ = ΔTtotal/ΣR
U-value
U = 1/(ΣR·A)

Pipe friction & head loss

Reynolds number
Re = V·D/ν = ρ·V·D/μ
Flow regime
laminar below Re ≈ 2000, turbulent above Re ≈ 4000
Mean velocity
V = Q/A, A = π·D²/4
Darcy–Weisbach
hf = f·(L/D)·V²/(2g)
Minor losses
hm = ΣK·V²/(2g)
Typical K values
entrance 0.5, exit 1.0, 90° bend ≈ 0.3
Pressure drop
Δp = ρ·g·hf
Two open reservoirs
Δz = (f·L/D + ΣK)·V²/(2g)
Free outlet
H = (1 + f·L/D + ΣK)·V²/(2g)

Pumps & pump power

Hydraulic power
Ph = ρ·g·Q·H = Q·Δp
Shaft power
Pshaft = Ph/ηpump
Electrical power
Pel = Pshaft/ηmotor
Pump head
H = Δz + Δp/(ρ·g) + hL
System losses
hL = (f·L/D + ΣK)·V²/(2g)

2Practice problems

1.Mass balanceMedium
MixerStream 1250 kg/h · 50% sugarStream 2ṁ₂ = ? · 5% sugarProduct25% sugar

How much of stream 2 must be added each hour to stream 1 so that the blended product contains 25% sugar? Find ṁ2.

ṁ1 = 250 kg/hx1 = 50 %x2 = 5 %x3 = 25 %
ṁ2 = kg/h
2.Mass balanceHard
EvaporatorFeed F2200 kg/h · 17% saltProduct P50% saltVapour W (pure water)W = ? kg/h

An evaporator concentrates a salt solution by boiling off pure water. Find the water evaporated W in kg/h.

F = 2200 kg/hxF = 17 %xP = 50 %
W = kg/h
3.Energy balanceMedium
hot sidecold sidelight oil · 170 °C80 °Cwater · 20 °Ct = ? °C

Hot light oil cools water in a counter-flow heat exchanger with no heat loss. Find the water outlet temperature tout.

ṁh = 2 kg/scp,h = 2.1 kJ/(kg·K)Th: 170 → 80 °Cṁc = 3 kg/scp,c = 4.18 kJ/(kg·K)tin = 20 °C
tout = °C
4.Energy balanceHard
hot sidecold sideglycol mix · 170 °C90 °Cwater · 10 °C25 °C · ṁ = ?15% lost

Hot glycol mix heats water in an exchanger that loses 15% of the heat released by the hot stream to the surroundings. Find the water flow rate ṁc needed.

ṁh = 2 kg/scp,h = 3.6 kJ/(kg·K)Th: 170 → 90 °Ct: 10 → 25 °Ccp,c = 4.18 kJ/(kg·K)loss = 15 %
ṁc = kg/s
5.Ideal gas lawMedium
250 g of ArP = 750 kPaT = 20 °CV = ?

What volume V does 250 g of Ar occupy at 750 kPa and 20 °C? Treat it as an ideal gas.

m = 250 gM = 39.95 g/molP = 750 kPaT = 20 °CR = 8.314 J/(mol·K)
V = L
6.Ideal gas lawHard
Ar, M = 39.95 g/molP = 200 kPaT = 150 °Cρ = ?

Find the density ρ of Ar at 200 kPa and 150 °C, treating it as an ideal gas.

M = 39.95 g/molP = 200 kPaT = 150 °CR = 8.314 J/(mol·K)
ρ = kg/m³
7.StoichiometryMedium
m(X)n(X)n(H2​O)m(H2​O)÷ M(X)× 2/ν× M(H2​O)

4 g of H2 and 32 g of O2 react according to 2H2 + O2 → 2H2O. What mass m of H2O can form?

M(H2) = 2.016M(O2) = 32M(H2O) = 18.02 g/mol
m = g
8.StoichiometryHard
m(Al)n(Al)n(AlCl3​)m(AlCl3​)÷ M(Al)× 2/2× M(AlCl3​)

In the reaction 2Al + 3Cl2 → 2AlCl3, 10 g of Al reacts completely (the other reactants are in excess) and 38.55 g of AlCl3 is collected. Find the percent yield Y.

M(Al) = 26.98 g/molM(AlCl3) = 133.33 g/molactual: 38.55 g
Y = %
9.Chemical equilibriumMedium
H2​I2​HII0.40.40C−x−x+2xE0.4 − x0.4 − x2x

0.4 mol/L of H₂ and 0.4 mol/L of I₂ are put in a container and react: H₂ + I₂ ⇌ 2HI, with Kc = 9. Find the equilibrium concentration [HI].

[H₂]₀ = [I₂]₀ = 0.4 mol/LKc = 9
[HI] = mol/L
10.Chemical equilibriumHard
PCl5​PCl3​Cl2​I0.400C−x+x+xE0.4 − xxx

PCl₅ decomposes: PCl₅ ⇌ PCl₃ + Cl₂, with Kc = 0.02 at the reaction temperature. A container starts with 0.4 mol/L of PCl₅ only. Find the equilibrium concentration [Cl2].

[PCl₅]₀ = 0.4 mol/LKc = 0.02
[Cl2] = mol/L
11.Calorimetry & enthalpyMedium
Tf​ = ?Zincm = 250 gT = 80 °Cc = 0.388 J/(g·°C)Waterm = 150 gT = 23 °Cc = 4.18 J/(g·°C)

A 250 g block of zinc (c = 0.388 J/(g·°C)) at 80 °C is dropped into 150 g of water (c = 4.18 J/(g·°C)) at 23 °C in an insulated cup. Find the final temperature Tf.

mmetal = 250 gcmetal = 0.388 J/(g·°C)Tmetal = 80 °Cmwater = 150 gTwater = 23 °Ccwater = 4.18 J/(g·°C)
Tf = °C
12.Calorimetry & enthalpyHard
H2C2​H6​ + 7O₂reactants4CO₂ + 6H₂O(l)productsΔH° = ?

Use the standard enthalpies of formation to find ΔH° for the reaction 2C2H6 + 7O₂ → 4CO₂ + 6H₂O(l).

ΔH°f(C2H6) = −84.7 kJ/molΔH°f(CO₂) = −393.5 kJ/molΔH°f(H₂O, l) = −285.8 kJ/molΔH°f(O₂) = 0
ΔH° = kJ
13.Reaction kineticsMedium
t (min)X (%)t = ?90%

A zero-order reaction has k = 0.005 mol/(L·min) and starts at 1.2 mol/L. How long does it take to reach 90% conversion? Find t.

k = 0.005 mol/(L·min)CA0 = 1.2 mol/LX = 90 %
t = min
14.Reaction kineticsHard
Tk30 °C0.0540 °C0.178

The rate constant of a reaction is 0.05 min⁻¹ at 30 °C and 0.178 min⁻¹ at 40 °C. Find the activation energy Ea.

k1 = 0.05 min⁻¹T1 = 30 °Ck2 = 0.178 min⁻¹T2 = 40 °CR = 8.314 J/(mol·K)
Ea = kJ/mol
15.Reactor sizing (CSTR & PFR)Medium
Q = 40 L/minCA0​ = 1.5 mol/LCA​ = ?V = 200 L, k = 0.5 min⁻¹

A liquid-phase first-order reaction A → B (k = 0.5 min⁻¹) runs in a 200 L plug-flow reactor (PFR). The feed enters at 40 L/min with CA0 = 1.5 mol/L. The density is constant and the reactor is at steady state. Find the outlet concentration CA.

V = 200 LQ = 40 L/mink = 0.5 min⁻¹CA0 = 1.5 mol/L
CA = mol/L
16.Reactor sizing (CSTR & PFR)Hard
V = 200 LQ = 40 L/minX = ?

A first-order liquid-phase reaction (k = 0.25 min⁻¹) runs in a 200 L CSTR fed at 40 L/min. The density is constant and the reactor is at steady state. Find the conversion X in percent.

V = 200 LQ = 40 L/mink = 0.25 min⁻¹
X = %
17.Heat exchangers (LMTD)Medium
lengthT150 °C40 °C110 °C25 °CΔT₁ΔT₂counter-flow

A counter-flow heat exchanger transfers 250 kW. The hot fluid cools from 150 to 40 °C and the cold fluid heats from 25 to 110 °C. The overall heat transfer coefficient is 200 W/(m²·K). Find the heat transfer area A needed.

Q̇ = 250 kWU = 200 W/(m²·K)Th: 150 → 40 °CTc: 25 → 110 °C
A = m²
18.Heat exchangers (LMTD)Hard
lengthT120 °C75 °C?20 °CΔT₁ΔT₂counter-flow

In a counter-flow double-pipe heat exchanger, hot oil (0.5 kg/s, cp = 2.5 kJ/(kg·K)) flows in the inner tube and cools from 120 to 75 °C. Water (0.2 kg/s, cp = 4.18 kJ/(kg·K)) in the annulus enters at 20 °C. The inner tube has a diameter of 25 mm, and U = 150 W/(m²·K) is based on this diameter. Find the tube length L needed.

ṁh = 0.5 kg/scp,h = 2.5 kJ/(kg·K)Th: 120 → 75 °Cṁc = 0.2 kg/sTc,in = 20 °CD = 25 mmU = 150 W/(m²·K)
L = m
19.Heat conductionMedium
Brick, k = 0.72200 mmMineral wool, k = 0.04150 mm17 °C1 °CTi​ = ?Q̇

A wall is made of 200 mm of brick and 150 mm of mineral wool, with an area of 12 m². The outer faces are at 17 °C and 1 °C. Find the temperature Ti at the interface between the two layers.

L1 = 200 mm, k1 = 0.72 W/(m·K)L2 = 150 mm, k2 = 0.04 W/(m·K)A = 12 m²T1 = 17 °CT3 = 1 °C
Ti = °C
20.Heat conductionHard
Concrete, k = 1.4200 mmGlass, k = 0.96100 mmroom 20 °Coutside 3 °CTs​ = ?Q̇

A wall of 200 mm concrete and 100 mm glass separates a room at 20 °C from outside air at 3 °C. The convection coefficients are 10 W/(m²·K) inside and 20 W/(m²·K) outside, and the wall area is 12 m². Find the temperature Ts of the inside surface of the wall.

L1 = 200 mm, k1 = 1.4 W/(m·K)L2 = 100 mm, k2 = 0.96 W/(m·K)A = 12 m²hi = 10 W/(m²·K)ho = 20 W/(m²·K)Troom = 20 °CTout = 3 °C
Ts = °C
21.Pipe friction & head lossMedium
V = 2.1 m/sD = 150 mmL = 100 mf = 0.018

Water (ρ = 1000 kg/m³) flows at 2.1 m/s through a horizontal pipe, 100 m long, with an inside diameter of 150 mm. Use the Darcy friction factor f = 0.018 and g = 9.81 m/s². Find the pressure drop Δp over the pipe in kPa.

V = 2.1 m/sL = 100 mD = 150 mmf = 0.018ρ = 1000 kg/m³
Δp = kPa
22.Pipe friction & head lossHard
K = 10free outletH = ?L = 100 m, D = 300 mm, f = 0.0183× bend (K = 0.3)

A pipe 100 m long with an inside diameter of 300 mm (Darcy friction factor f = 0.018) runs from an open reservoir and discharges as a free jet into the air. The minor losses are a square-edged entrance (K = 0.5), 3 bends (K = 0.3 each) and a valve (K = 10). Use g = 9.81 m/s². How far H must the reservoir surface be above the pipe outlet for a flow rate of 200 L/s?

Q = 200 L/sL = 100 mD = 300 mmf = 0.018Kentrance = 0.5Kbend = 0.3 (×3)Kvalve = 10
H = m
23.Pumps & pump powerMedium
PQ = 40 L/sH = 14 m

In a test, a pump delivers 40 L/s of water (ρ = 1000 kg/m³) against a head of 14 m while its shaft takes 7.3 kW. Use g = 9.81 m/s². Find the pump efficiency η in percent.

Q = 40 L/sH = 14 mPshaft = 7.3 kWg = 9.81 m/s²
η = %
24.Pumps & pump powerHard
PQ = 15 L/sΔz = 8 mL = 100 m, D = 100 mm, f = 0.015, ΣK = 5

A pump moves 15 L/s of water (ρ = 1000 kg/m³) from an open lower reservoir to an upper tank whose water surface is 8 m higher. The pipe is 100 m long with an inside diameter of 100 mm and a Darcy friction factor f = 0.015; the minor-loss coefficients add up to ΣK = 5 (entrance and exit included). Use g = 9.81 m/s². Find the head H the pump must add.

Q = 15 L/sΔz = 8 mL = 100 mD = 100 mmf = 0.015ΣK = 5
H = m

3Solutions

1.Mass balance

Answer: ṁ2 = 312.5 kg/h

Steady-state mass balance: in = out for the total and for each component. Blending problems combine both.

Balances

Total: ṁ3 = ṁ1 + ṁ2
sugar: ṁ1x1 + ṁ2x2 = (ṁ1 + ṁ2)x3

Solve for ṁ2

ṁ2 = ṁ1(x1 − x3)/(x3 − x2) = 250·(50 − 25)/(25 − 5) = 312.5 kg/h

Answer

ṁ2 = 312.5 kg/h
2.Mass balance

Answer: W = 1452 kg/h

Tie component: a component that passes through unchanged in one stream (here the solute) links the flows directly. Then the total balance gives the rest.

Solute balance

F·xF = P·xP → P = 2200·17/50 = 748 kg/h

Total balance

W = F − P = 2200 − 748 = 1452 kg/h

Answer

W = 1452 kg/h
3.Energy balance

Answer: tout = 50.14 °C

Exchanger energy balance: with no losses, ṁhcp,h(Th,in − Th,out) = ṁccp,c(tout − tin).

Heat released by the hot stream

Q = 2·2.1·(170 − 80) = 378 kW

Heat picked up by the water

tout = tin + Q/(ṁccp,c) = 20 + 378/(3·4.18) = 50.14 °C

Answer

tout = 50.14 °C
4.Energy balance

Answer: ṁc = 7.809 kg/s

Energy balance with losses: heat released = heat absorbed + heat lost.

Heat released

Qh = 2·3.6·(170 − 90) = 576 kW

Heat that reaches the water

Qc = (1 − 0.15)·576 = 489.6 kW

Water flow rate

ṁc = Qc/(cp,c·Δt) = 489.6/(4.18·15) = 7.809 kg/s

Answer

ṁc = 7.809 kg/s
5.Ideal gas law

Answer: V = 20.34 L

Ideal gas law: PV = nRT, with n = m/M.

Moles

n = 250/39.95 = 6.258 mol
T = 20 + 273.15 = 293.1 K

Volume

V = nRT/P = 6.258·8.314·293.1/750 = 20.34 L

Answer

V = 20.34 L
6.Ideal gas law

Answer: ρ = 2.271 kg/m³

Ideal gas density: ρ = PM/(RT).

Rearrange the gas law

PV = (m/M)RT → ρ = m/V = PM/(RT)
T = 150 + 273.15 = 423.1 K

Density

ρ = 200·39.95/(8.314·423.1) = 2.271 kg/m³

Answer

ρ = 2.271 kg/m³
7.Stoichiometry

Answer: m = 35.75 g

Stoichiometry: a balanced equation counts particles, not grams. Convert mass to moles with n = m/M, use the coefficients of the equation as the mole ratio, then convert back with m = n·M. With two reactants, the limiting reactant is the one that runs out first and fixes how much product forms.

Moles of each reactant

n(H2) = 4/2.016 = 1.984 mol
n(O2) = 32/32 = 1 mol

Limiting reactant

1.984/2 = 0.9921, 1/1 = 1 → H2

Mass of product

n(H2O) = 0.9921·2 = 1.984 mol
m = 1.984·18.02 = 35.75 g

Answer

m = 35.75 g
8.Stoichiometry

Answer: Y = 78.01 %

Stoichiometry: a balanced equation counts particles, not grams. Convert mass to moles with n = m/M, use the coefficients of the equation as the mole ratio, then convert back with m = n·M. With two reactants, the limiting reactant is the one that runs out first and fixes how much product forms.

Theoretical yield

n(Al) = 10/26.98 = 0.3706 mol
m = 0.3706·2/2·133.33 = 49.42 g

Percent yield

Y = 38.55/49.42·100 = 78.01%

Answer

Y = 78.01%
9.Chemical equilibrium

Answer: [HI] = 0.48 mol/L

Chemical equilibrium: for aA + bB ⇌ cC + dD, the equilibrium constant is Kc = [C]c[D]d/([A]a[B]b), using concentrations at equilibrium. An ICE table (Initial, Change, Equilibrium) links the starting amounts to the equilibrium amounts through one unknown x, scaled by the coefficients.

Equilibrium expression

9 = (2x)²/(0.4 − x)²

Take the square root

3 = 2x/(0.4 − x) → x = 0.4·3/(2 + 3) = 0.24 mol/L

Equilibrium concentration

[HI] = 2x = 0.48 mol/L

Answer

[HI] = 0.48 mol/L
10.Chemical equilibrium

Answer: [Cl2] = 0.08 mol/L

Chemical equilibrium: for aA + bB ⇌ cC + dD, the equilibrium constant is Kc = [C]c[D]d/([A]a[B]b), using concentrations at equilibrium. An ICE table (Initial, Change, Equilibrium) links the starting amounts to the equilibrium amounts through one unknown x, scaled by the coefficients.

Equilibrium expression

0.02 = x²/(0.4 − x) → x² + 0.02·x − 0.008 = 0

Solve the quadratic

x = (−0.02 + √(0.02² + 4·0.008))/2 = 0.08 mol/L

Equilibrium concentration

[Cl₂] = x = 0.08 mol/L

Answer

[Cl2] = 0.08 mol/L
11.Calorimetry & enthalpy

Answer: Tf = 30.64 °C

Heat and enthalpy: heating a substance takes q = m·c·ΔT. In a calorimeter the heat lost by the hot object equals the heat gained by the cold one. The enthalpy change of a reaction follows from enthalpies of formation: ΔH° = ΣΔH°f(products) − ΣΔH°f(reactants), each multiplied by its coefficient.

Heat balance

250·0.388·(80 − Tf) = 150·4.18·(Tf − 23)

Solve for the final temperature

Tf = (97·80 + 627·23)/(97 + 627) = 30.64 °C

Answer

Tf = 30.64 °C
12.Calorimetry & enthalpy

Answer: ΔH° = −3119 kJ

Heat and enthalpy: heating a substance takes q = m·c·ΔT. In a calorimeter the heat lost by the hot object equals the heat gained by the cold one. The enthalpy change of a reaction follows from enthalpies of formation: ΔH° = ΣΔH°f(products) − ΣΔH°f(reactants), each multiplied by its coefficient.

Enthalpy of reaction

ΔH° = [4·(−393.5) + 6·(−285.8)] − [2·(−84.7) + 7·0] = −3119 kJ

Answer

ΔH° = −3119 kJ

Negative: the reaction gives off heat (exothermic).

13.Reaction kinetics

Answer: t = 216 min

Integrated rate laws: zero order: C = C₀ − kt (straight line, t½ = C₀/(2k)); first order: ln(C₀/C) = kt (t½ = ln 2/k); second order: 1/C − 1/C₀ = kt (t½ = 1/(kC₀)). Conversion X means C = C₀(1 − X).

Amount converted

CA0·X = 1.2·0.9 = 1.08 mol/L

Time

t = CA0·X/k = 1.08/0.005 = 216 min

Answer

t = 216 min
14.Reaction kinetics

Answer: Ea = 100.2 kJ/mol

Reaction rates: for a first-order reaction −dC/dt = kC, so C = C₀·e−kt and the half-life ln 2/k does not depend on concentration. For a second-order reaction 1/C = 1/C₀ + kt. The rate constant rises with temperature following Arrhenius: k = A·e−Ea/(RT).

Absolute temperatures

T1 = 303.1 K, T2 = 313.1 K

Solve Arrhenius for Ea

Ea = −R·ln(k2/k1)/(1/T2 − 1/T1) = −8.314·1.27/(-1.053e-4) = 100217 J/mol
Ea = 100.2 kJ/mol

Answer

Ea = 100.2 kJ/mol
15.Reactor sizing (CSTR & PFR)

Answer: CA = 0.1231 mol/L

Ideal reactors, first-order reaction (−rA = k·CA) at steady state, with space time τ = V/Q. A CSTR is perfectly mixed, so the whole volume reacts at the low outlet concentration: τ = X/(k·(1 − X)) and CA = CA0/(1 + k·τ). In a PFR each slice of fluid reacts like a small batch reactor: τ = ln(1/(1 − X))/k and CA = CA0·e−k·τ. For the same conversion a CSTR always needs more volume than a PFR.

Space time

τ = V/Q = 200/40 = 5 min

Outlet concentration

CA = 1.5·e−0.5·5 = 0.1231 mol/L

Answer

CA = 0.1231 mol/L

Conversion: X = 91.79%.

16.Reactor sizing (CSTR & PFR)

Answer: X = 55.56 %

Ideal reactors, first-order reaction (−rA = k·CA) at steady state, with space time τ = V/Q. A CSTR is perfectly mixed, so the whole volume reacts at the low outlet concentration: τ = X/(k·(1 − X)) and CA = CA0/(1 + k·τ). In a PFR each slice of fluid reacts like a small batch reactor: τ = ln(1/(1 − X))/k and CA = CA0·e−k·τ. For the same conversion a CSTR always needs more volume than a PFR.

Space time

τ = V/Q = 200/40 = 5 min, kτ = 0.25·5 = 1.25

Conversion

X = kτ/(1 + kτ) = 1.25/(1 + 1.25) = 55.56%

Answer

X = 55.56%
17.Heat exchangers (LMTD)

Answer: A = 49.04 m²

LMTD method: the temperature difference between the streams changes along the exchanger, so the rate equation uses its logarithmic mean: Q̇ = U·A·ΔTlm, with ΔTlm = (ΔT₁ − ΔT₂)/ln(ΔT₁/ΔT₂), where ΔT₁ and ΔT₂ are the differences at the two ends. Counter-flow gives a larger ΔTlm than parallel flow for the same inlet and outlet temperatures.

End temperature differences

In counter-flow the hot inlet faces the cold outlet, and the hot outlet faces the cold inlet.

ΔT₁ = Th,in − Tc,out = 150 − 110 = 40 K
ΔT₂ = Th,out − Tc,in = 40 − 25 = 15 K

Log-mean temperature difference

ΔTlm = (ΔT₁ − ΔT₂)/ln(ΔT₁/ΔT₂) = (40 − 15)/ln(40/15) = 25.49 K

Area

A = Q̇/(U·ΔTlm) = 250000/(200·25.49) = 49.04 m²

Answer

A = 49.04 m²
18.Heat exchangers (LMTD)

Answer: L = 111.3 m

LMTD method: the temperature difference between the streams changes along the exchanger, so the rate equation uses its logarithmic mean: Q̇ = U·A·ΔTlm, with ΔTlm = (ΔT₁ − ΔT₂)/ln(ΔT₁/ΔT₂), where ΔT₁ and ΔT₂ are the differences at the two ends. Counter-flow gives a larger ΔTlm than parallel flow for the same inlet and outlet temperatures.

Heat duty and water outlet temperature

Q̇ = 0.5·2.5·(120 − 75) = 56.25 kW
Tc,out = 20 + 56.25/(0.2·4.18) = 87.28 °C

End temperature differences

In counter-flow the hot inlet faces the cold outlet, and the hot outlet faces the cold inlet.

ΔT₁ = Th,in − Tc,out = 120 − 87.28 = 32.72 K
ΔT₂ = Th,out − Tc,in = 75 − 20 = 55 K

Log-mean temperature difference

ΔTlm = (ΔT₁ − ΔT₂)/ln(ΔT₁/ΔT₂) = (32.72 − 55)/ln(32.72/55) = 42.9 K

Area and length

A = 56250/(150·42.9) = 8.742 m²
L = A/(πD) = 8.742/(π·0.025) = 111.3 m

Answer

L = 111.3 m
19.Heat conduction

Answer: Ti = 15.9 °C

Thermal resistance: steady heat flow through layers in series behaves like current through resistors in series: Q̇ = ΔT/ΣR, with R = L/(kA) for a conducting layer and R = 1/(hA) for a convecting surface. The temperature drop across each layer is proportional to its resistance.

Layer resistances

R1 = L1/(k1A) = (200/1000)/(0.72·12) = 0.02315 K/W
R2 = L2/(k2A) = (150/1000)/(0.04·12) = 0.3125 K/W

Heat flow

Q̇ = (T1 − T3)/(R1 + R2) = 16/0.3356 = 47.67 W

Interface temperature

The temperature drops across the first layer by Q̇·R₁.

Ti = T1 − Q̇·R1 = 17 − 47.67·0.02315 = 15.9 °C

Answer

Ti = 15.9 °C
20.Heat conduction

Answer: Ts = 15.72 °C

Thermal resistance: steady heat flow through layers in series behaves like current through resistors in series: Q̇ = ΔT/ΣR, with R = L/(kA) for a conducting layer and R = 1/(hA) for a convecting surface. The temperature drop across each layer is proportional to its resistance.

Resistances in series

Ri = 1/(hiA) = 1/(10·12) = 0.008333 K/W
R1 = L1/(k1A) = (200/1000)/(1.4·12) = 0.0119 K/W
R2 = L2/(k2A) = (100/1000)/(0.96·12) = 0.008681 K/W
Ro = 1/(hoA) = 1/(20·12) = 0.004167 K/W
ΣR = 0.03309 K/W

Heat loss

Q̇ = (20 − (3))/0.03309 = 513.8 W
Ts = Troom − Q̇·Ri = 20 − 513.8·0.008333 = 15.72 °C

Answer

Ts = 15.72 °C
21.Pipe friction & head loss

Answer: Δp = 26.46 kPa

Pipe flow: the Reynolds number Re = V·D/ν = ρ·V·D/μ tells laminar flow (Re below about 2000) from turbulent flow (above about 4000). Friction along a pipe costs the Darcy–Weisbach head loss hf = f·(L/D)·V²/(2g). Fittings, valves, the entrance and the exit add minor losses hm = ΣK·V²/(2g). Between two open reservoir surfaces the energy equation gives Δz = hf + hm, with the exit loss K = 1 included.

Head loss

hf = f·(L/D)·V²/(2g) = 0.018·(100/0.15)·2.1²/(2·9.81) = 2.697 m

Pressure drop

The pipe is horizontal and the velocity does not change, so the energy equation reduces to Δp = ρ·g·hf.

Δp = ρ·g·hf = 1000·9.81·2.697 = 26460 Pa = 26.46 kPa

Answer

Δp = 26.46 kPa
22.Pipe friction & head loss

Answer: H = 7.508 m

Pipe flow: the Reynolds number Re = V·D/ν = ρ·V·D/μ tells laminar flow (Re below about 2000) from turbulent flow (above about 4000). Friction along a pipe costs the Darcy–Weisbach head loss hf = f·(L/D)·V²/(2g). Fittings, valves, the entrance and the exit add minor losses hm = ΣK·V²/(2g). Between two open reservoir surfaces the energy equation gives Δz = hf + hm, with the exit loss K = 1 included.

Velocity

V = Q/A = 0.2/0.07069 = 2.829 m/s
V²/(2g) = 0.408 m

Loss coefficients

f·L/D = 0.018·100/0.3 = 6
ΣK = 0.5 + 3·0.3 + 10 = 11.4

Energy equation

The outlet jet still carries its velocity head; it is not a loss but it has to be supplied.

H = (1 + 6 + 11.4)·0.408 = 7.508 m

Answer

H = 7.508 m
23.Pumps & pump power

Answer: η = 75.25 %

Pump power: the power given to the water is the hydraulic power Ph = ρ·g·Q·H = Q·Δp. The shaft must deliver more because the pump loses some: Pshaft = Ph/ηpump, and the motor draws Pel = Pshaft/ηmotor. The pump head H follows from the energy equation: static lift + pressure head + all friction and minor losses.

Hydraulic power

Ph = ρ·g·Q·H = 1000·9.81·0.04·14 = 5.494 kW

Efficiency

η = Ph/Pshaft = 5.494/7.3 = 75.25%

Answer

η = 75.25%
24.Pumps & pump power

Answer: H = 11.72 m

Pump power: the power given to the water is the hydraulic power Ph = ρ·g·Q·H = Q·Δp. The shaft must deliver more because the pump loses some: Pshaft = Ph/ηpump, and the motor draws Pel = Pshaft/ηmotor. The pump head H follows from the energy equation: static lift + pressure head + all friction and minor losses.

Velocity

V = Q/A = 0.015/0.007854 = 1.91 m/s
V²/(2g) = 0.1859 m

Head losses

hL = (f·L/D + ΣK)·V²/(2g) = (15 + 5)·0.1859 = 3.718 m

Pump head

Both surfaces are open and practically at rest, so pressure and velocity terms drop out.

H = Δz + hL = 8 + 3.718 = 11.72 m

Answer

H = 11.72 m

This is independent practice material. ExamProblems is not affiliated with or endorsed by the organisation that runs this exam, and the exam name is used only to describe the content. The FE exam is run by NCEES, which is not affiliated with ExamProblems and does not endorse it.