Mass balance
- Steady state
- in = out
- Total balance
- ṁ1 + ṁ2 = ṁ3
- Component balance
- ṁ1x1 + ṁ2x2 = ṁ3x3
- Evaporator
- F·xF = P·xP, W = F − P
Formula sheets, the key method steps for every topic and 24 practice problems, with full solutions at the back.
How much of stream 2 must be added each hour to stream 1 so that the blended product contains 25% NaOH? Find ṁ2.
An evaporator concentrates a salt solution by boiling off pure water. Find the water evaporated W in kg/h.
Hot light oil cools water in a counter-flow heat exchanger with no heat loss. Find the water outlet temperature tout.
Hot light oil heats water in an exchanger that loses 10% of the heat released by the hot stream to the surroundings. Find the water flow rate ṁc needed.
A tank of 30 L contains 330 g of CH₄ at 100 °C. Treat it as an ideal gas and find the pressure P.
A fixed amount of Ar goes from 200 kPa, 2 L, 35 °C to 500 kPa and 190 °C. Find the new volume V2.
8 g of Fe2O3 and 80 g of CO react according to Fe2O3 + 3CO → 2Fe + 3CO2. What mass m of Fe can form?
In the reaction 2H2 + O2 → 2H2O, 6 g of H2 reacts completely (the other reactants are in excess) and 41.83 g of H2O is collected. Find the percent yield Y.
0.2 mol/L of H₂ and 0.2 mol/L of I₂ are put in a container and react: H₂ + I₂ ⇌ 2HI, with Kc = 4. Find the equilibrium concentration [H2].
PCl₅ decomposes: PCl₅ ⇌ PCl₃ + Cl₂, with Kc = 0.05 at the reaction temperature. A container starts with 0.2 mol/L of PCl₅ only. Find the equilibrium concentration [Cl2].
A 200 g block of iron (c = 0.449 J/(g·°C)) at 80 °C is dropped into 200 g of water (c = 4.18 J/(g·°C)) at 21 °C in an insulated cup. Find the final temperature Tf.
Use the standard enthalpies of formation to find the heat q released when 50 g of C2H6 (M = 30.07 g/mol) burns completely: 2C2H6 + 7O₂ → 4CO₂ + 6H₂O(l). Give q as a positive number.
A reaction with rate law −rA = k·CA² has k = 0.4 L/(mol·min) and starts at 1.5 mol/L. Find the concentration CA after 30 min.
The rate constant of a reaction is 0.1 min⁻¹ at 35 °C and 21.7 min⁻¹ at 75 °C. Find the activation energy Ea.
A first-order liquid-phase reaction must reach 90% conversion. How many times larger must a CSTR be than a PFR for the same feed rate, rate constant and conversion? Find the ratio VCSTR/VPFR.
A first-order liquid-phase reaction (k = 0.25 min⁻¹) runs in a 500 L CSTR fed at 20 L/min. The density is constant and the reactor is at steady state. Find the conversion X in percent.
A parallel-flow heat exchanger transfers 400 kW. The hot fluid cools from 95 to 80 °C and the cold fluid heats from 20 to 55 °C. The overall heat transfer coefficient is 200 W/(m²·K). Find the heat transfer area A needed.
Hot oil (1 kg/s, cp = 2.5 kJ/(kg·K)) cools from 130 to 100 °C in a counter-flow exchanger. It heats 1.5 kg/s of water (cp = 4.18 kJ/(kg·K)) that enters at 15 °C. With U = 300 W/(m²·K), find the heat transfer area A needed.
A wall is made of 50 mm of wood and 100 mm of expanded polystyrene, with an area of 12 m². The outer faces are at 17 °C and 9 °C. Find the heat flow Q̇ through the wall.
A wall of 250 mm wood and 75 mm expanded polystyrene separates a room at 22 °C from outside air at -3 °C. The convection coefficients are 10 W/(m²·K) inside and 30 W/(m²·K) outside, and the wall area is 15 m². Find the heat loss Q̇ through the wall.
Water flows at a mean velocity of 2.9 m/s through a pipe 50 m long with an inside diameter of 100 mm. Use the Darcy friction factor f = 0.022 and g = 9.81 m/s². Find the friction head loss hf.
Two open reservoirs are joined by a pipe 200 m long with an inside diameter of 300 mm and a Darcy friction factor f = 0.022. The minor losses are a square-edged entrance (K = 0.5), 2 bends (K = 0.3 each), a valve (K = 10) and the exit into the lower reservoir (K = 1.0). Use g = 9.81 m/s². What difference in water level Δz between the reservoirs gives a flow rate of 150 L/s?
A pump delivers 150 L/s of water (ρ = 1000 kg/m³) against a head of 62 m. The pump efficiency is 70% and the electric motor driving it has an efficiency of 94%. Use g = 9.81 m/s². Find the electrical power Pel the motor draws, in kW.
A pump moves 80 L/s of water (ρ = 1000 kg/m³) from an open lower reservoir to an upper tank whose water surface is 12 m higher. The pipe is 200 m long with an inside diameter of 200 mm and a Darcy friction factor f = 0.015; the minor-loss coefficients add up to ΣK = 5 (entrance and exit included). Use g = 9.81 m/s². The upper tank is closed and the air above its water is at a gauge pressure of 200 kPa. Find the head H the pump must add.
Answer: ṁ2 = 250 kg/h
Steady-state mass balance: in = out for the total and for each component. Blending problems combine both.
Answer: W = 2632 kg/h
Tie component: a component that passes through unchanged in one stream (here the solute) links the flows directly. Then the total balance gives the rest.
Answer: tout = 71.52 °C
Exchanger energy balance: with no losses, ṁhcp,h(Th,in − Th,out) = ṁccp,c(tout − tin).
Answer: ṁc = 1.252 kg/s
Energy balance with losses: heat released = heat absorbed + heat lost.
Answer: P = 2128 kPa
Ideal gas law: PV = nRT, with n = m/M.
Answer: V2 = 1.202 L
Combined gas law: for a fixed amount of ideal gas, P1V1/T1 = P2V2/T2.
Answer: m = 5.596 g
Stoichiometry: a balanced equation counts particles, not grams. Convert mass to moles with n = m/M, use the coefficients of the equation as the mole ratio, then convert back with m = n·M. With two reactants, the limiting reactant is the one that runs out first and fixes how much product forms.
Answer: Y = 78 %
Stoichiometry: a balanced equation counts particles, not grams. Convert mass to moles with n = m/M, use the coefficients of the equation as the mole ratio, then convert back with m = n·M. With two reactants, the limiting reactant is the one that runs out first and fixes how much product forms.
Answer: [H2] = 0.1 mol/L
Chemical equilibrium: for aA + bB ⇌ cC + dD, the equilibrium constant is Kc = [C]c[D]d/([A]a[B]b), using concentrations at equilibrium. An ICE table (Initial, Change, Equilibrium) links the starting amounts to the equilibrium amounts through one unknown x, scaled by the coefficients.
Answer: [Cl2] = 0.07808 mol/L
Chemical equilibrium: for aA + bB ⇌ cC + dD, the equilibrium constant is Kc = [C]c[D]d/([A]a[B]b), using concentrations at equilibrium. An ICE table (Initial, Change, Equilibrium) links the starting amounts to the equilibrium amounts through one unknown x, scaled by the coefficients.
Answer: Tf = 26.72 °C
Heat and enthalpy: heating a substance takes q = m·c·ΔT. In a calorimeter the heat lost by the hot object equals the heat gained by the cold one. The enthalpy change of a reaction follows from enthalpies of formation: ΔH° = ΣΔH°f(products) − ΣΔH°f(reactants), each multiplied by its coefficient.
Answer: q = 2593 kJ
Heat and enthalpy: heating a substance takes q = m·c·ΔT. In a calorimeter the heat lost by the hot object equals the heat gained by the cold one. The enthalpy change of a reaction follows from enthalpies of formation: ΔH° = ΣΔH°f(products) − ΣΔH°f(reactants), each multiplied by its coefficient.
Answer: CA = 0.07895 mol/L
Reaction rates: for a first-order reaction −dC/dt = kC, so C = C₀·e−kt and the half-life ln 2/k does not depend on concentration. For a second-order reaction 1/C = 1/C₀ + kt. The rate constant rises with temperature following Arrhenius: k = A·e−Ea/(RT).
Answer: Ea = 120 kJ/mol
Reaction rates: for a first-order reaction −dC/dt = kC, so C = C₀·e−kt and the half-life ln 2/k does not depend on concentration. For a second-order reaction 1/C = 1/C₀ + kt. The rate constant rises with temperature following Arrhenius: k = A·e−Ea/(RT).
Answer: VCSTR/VPFR = 3.909
Ideal reactors, first-order reaction (−rA = k·CA) at steady state, with space time τ = V/Q. A CSTR is perfectly mixed, so the whole volume reacts at the low outlet concentration: τ = X/(k·(1 − X)) and CA = CA0/(1 + k·τ). In a PFR each slice of fluid reacts like a small batch reactor: τ = ln(1/(1 − X))/k and CA = CA0·e−k·τ. For the same conversion a CSTR always needs more volume than a PFR.
The gap grows quickly at high conversion.
Answer: X = 86.21 %
Ideal reactors, first-order reaction (−rA = k·CA) at steady state, with space time τ = V/Q. A CSTR is perfectly mixed, so the whole volume reacts at the low outlet concentration: τ = X/(k·(1 − X)) and CA = CA0/(1 + k·τ). In a PFR each slice of fluid reacts like a small batch reactor: τ = ln(1/(1 − X))/k and CA = CA0·e−k·τ. For the same conversion a CSTR always needs more volume than a PFR.
Answer: A = 43.94 m²
LMTD method: the temperature difference between the streams changes along the exchanger, so the rate equation uses its logarithmic mean: Q̇ = U·A·ΔTlm, with ΔTlm = (ΔT₁ − ΔT₂)/ln(ΔT₁/ΔT₂), where ΔT₁ and ΔT₂ are the differences at the two ends. Counter-flow gives a larger ΔTlm than parallel flow for the same inlet and outlet temperatures.
In parallel flow both inlets are at the same end, and both outlets at the other.
Answer: A = 2.667 m²
LMTD method: the temperature difference between the streams changes along the exchanger, so the rate equation uses its logarithmic mean: Q̇ = U·A·ΔTlm, with ΔTlm = (ΔT₁ − ΔT₂)/ln(ΔT₁/ΔT₂), where ΔT₁ and ΔT₂ are the differences at the two ends. Counter-flow gives a larger ΔTlm than parallel flow for the same inlet and outlet temperatures.
In counter-flow the hot inlet faces the cold outlet, and the hot outlet faces the cold inlet.
Answer: Q̇ = 30.46 W
Thermal resistance: steady heat flow through layers in series behaves like current through resistors in series: Q̇ = ΔT/ΣR, with R = L/(kA) for a conducting layer and R = 1/(hA) for a convecting surface. The temperature drop across each layer is proportional to its resistance.
Answer: Q̇ = 100.1 W
Thermal resistance: steady heat flow through layers in series behaves like current through resistors in series: Q̇ = ΔT/ΣR, with R = L/(kA) for a conducting layer and R = 1/(hA) for a convecting surface. The temperature drop across each layer is proportional to its resistance.
Answer: hf = 4.715 m
Pipe flow: the Reynolds number Re = V·D/ν = ρ·V·D/μ tells laminar flow (Re below about 2000) from turbulent flow (above about 4000). Friction along a pipe costs the Darcy–Weisbach head loss hf = f·(L/D)·V²/(2g). Fittings, valves, the entrance and the exit add minor losses hm = ΣK·V²/(2g). Between two open reservoir surfaces the energy equation gives Δz = hf + hm, with the exit loss K = 1 included.
Answer: Δz = 6.143 m
Pipe flow: the Reynolds number Re = V·D/ν = ρ·V·D/μ tells laminar flow (Re below about 2000) from turbulent flow (above about 4000). Friction along a pipe costs the Darcy–Weisbach head loss hf = f·(L/D)·V²/(2g). Fittings, valves, the entrance and the exit add minor losses hm = ΣK·V²/(2g). Between two open reservoir surfaces the energy equation gives Δz = hf + hm, with the exit loss K = 1 included.
Answer: Pel = 138.7 kW
Pump power: the power given to the water is the hydraulic power Ph = ρ·g·Q·H = Q·Δp. The shaft must deliver more because the pump loses some: Pshaft = Ph/ηpump, and the motor draws Pel = Pshaft/ηmotor. The pump head H follows from the energy equation: static lift + pressure head + all friction and minor losses.
Answer: H = 39 m
Pump power: the power given to the water is the hydraulic power Ph = ρ·g·Q·H = Q·Δp. The shaft must deliver more because the pump loses some: Pshaft = Ph/ηpump, and the motor draws Pel = Pshaft/ηmotor. The pump head H follows from the energy equation: static lift + pressure head + all friction and minor losses.
Both surfaces are practically at rest, so there is no velocity head term.
This is independent practice material. ExamProblems is not affiliated with or endorsed by the organisation that runs this exam, and the exam name is used only to describe the content. The FE exam is run by NCEES, which is not affiliated with ExamProblems and does not endorse it.
ExamProblems · examproblems.com/courses/fe-exam-chemical